Certain B/R And E/M Repairs And Periodical Services At Jcda Office , Hostel , Dad Guest House And Other Minor Units And Ross Island Under Age B/R-I At Ge Haddo , Port Blairrt Blair, GE Haddo Port Blair-Andaman And Nicobar Islands

Military Engineer Services-MES has published Certain B/R And E/M Repairs And Periodical Services At Jcda Office , Hostel , Dad Guest House And Other Minor Units And Ross Island Under Age B/R-I At Ge Haddo , Port Blairrt Blair. Submission Date for this Tender is 10-11-2020. Electromechanical Work Tenders in GE Haddo Port Blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

25843072
Certain B/R And E/M Repairs And Periodical Services At Jcda Office , Hostel , Dad Guest House And Other Minor Units And Ross Island Under Age B/R-I At Ge Haddo , Port Blairrt Blair
Open Tender
Indian
Andaman And Nicobar Islands
GE Haddo Port Blair
10-11-2020

Tender Details

Certain B / R And E / M Repairs And Periodical Services At Jcda Office , Hostel , Dad Guest House And Other Minor Units And Ross Island Under Age B / R-I At Ge Haddo , Port Blairrt Blair

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: CERTAIN B/R AND E/M REPAIRS AND PERIODICAL SERVICES AT JCDA OFFICE, HOSTEL, DAD GUEST HOUSE AND OTHER MINOR UNITS AND ROSS ISLAND UNDER AGE B/R-I AT GE HADDO, PORT BLAIR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified and as directed. 6 EACH
2 2 Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed. 15 EACH
3 3 S&F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. 0.6 CUM
4 4 S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube as per specification & drawing, fixed in opening in repairs complete all as specified and as directed. 16 RM
5 5 S&F factory made solid PVC moulded door shutter with particle board core, 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm plain colour PVC sheet on back face as per specification & drawing fixed to door frame complete all as specified and as directed. 9 SQM
6 6 M&L for mild steel hold fasts, bands, straps, supports or stays for rainwater, brackets/clamps for eaves and valley gutter and similar articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. 41 KG
7 7 M&L for aluminium anodised door/window/ventilator shutters fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed.\nNOTES:\n(i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. \n(ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc.\n(iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose. 100 KG
8 8 SUPPLY ONLY 4.0 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.\n 11 SQM
9 9 SUPPLY ONLY 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination, fixed with screws complete all as specified and as directed. 11 SQM
10 10 S&F 35mm thick second class hard wood plain framed, panelled shutter (two panel) with lock rail and panels of timber flat on both sides (feather edged) or 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated, fixed to door frame complete all as specified and as directed. 30 SQM
11 11 S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), fixed to chowkats complete all as specified and as directed. 30 SQM
12 12 Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. 16 CUM
13 13 M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed. 14 CUM
14 14 M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry not exceeding 10cm in width and setting in cement mortar (1:4) complete all as specified and directed. 20 SQM
15 15 M&L for plain cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in lintels upto 1.5m clear span, cills and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed. 0.72 CUM
16 16 M&L for cutting holes in brick walls for inserting hold fasts, exceeding half brick thick but not exceeding one brick thick, built in cement mortar and making good disturbed portions in CM(1:3) or PCC(1:3:6) type C1 complete all as specified and as directed. 45 EACH
17 17 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 140 SQM
18 18 M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. 15 SQM
19 19 M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. 40 SQM
20 20 M&L for vitrified coloured tiles 10 mm thick (square/ rectangular), area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. 50 SQM
21 21 M&L for glazed ceramic designed coloured tiles in vertical surfaces using size of tiles 350x250x7mm/ 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tile with and including 10mm thick backing coat in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. 35 SQM
22 22 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar 4.2 X SQM
23 23 M&L for glossy finished chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.\n 35 SQM
24 24 M&L for 18 to 20mm thick granite work (of any type and shade as approved) table rubbed and polished as in steps, jambs, pillars, window cills, cooking platforms, wash basin counters and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick cement mortar (1:4) bedding and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, rounding (chamfering) the edges complete all as specified and directed. 7 SQM
25 25 Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed. 300 SQM
26 26 M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.\n 140 SQM
27 27 M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.\nNOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule. 160 SQM
28 28 Supply only integral water proofing compound. 20.45 KG
29 29 M&L for preparation of old wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint of first quality complete all as specified and as directed. 150 SQM
30 30 M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of pink primer complete all as specified and as directed. 126 SQM
31 31 M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint of first quality complete all as specified and as directed. 150 SQM
32 32 M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed. 75 SQM
33 33 M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and as directed.\n 210 SQM
34 34 M&L for preparation of newly plastered surfaces of ceilings of any description and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and as directed.\n 100 SQM
35 35 M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and as directed.\n 1000 SQM
36 36 M&L for preparation of old plastered surfaces of ceilings by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and as directed.\n 150 SQM
37 37 M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer after filling the cracks with filler complete all as specified and as directed.\n\n 2800 SQM
38 38 M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.\n 225 SQM
39 39 S&F 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.\n 32 EACH
40 40 S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.\n 60 EACH
41 41 S&F 100mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.\n 12 EACH
42 42 S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.\n 40 EACH
43 43 S&F sliding door bolt, 300mm long, aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.\n 15 EACH
44 44 S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21 complete all as specified and as directed.\n 18 EACH
45 45 S&F 125mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21 complete all as specified and as directed.\n 90 EACH
46 46 S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150mm complete all as specified and as directed.\n 30 EACH
47 47 S&F door closer, aluminium (extruded section body), hydraulically regulated, designation No. 1, universal type, suitable for door shutters of 700 mm in width and of weight not more than 35 kg and fixed with screws in repairs complete all as specified and as directed.\n 4 EACH
48 48 S&F aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed. 6 SQM
49 49 M&L for 12mm thick designed rubco hut rubber wood for interior designing such as wall panelling, frame shutter for cupboard, shelves, cabinets, box structure and the like with finish to match all adjoining surfaces including sanding and applying mixture of filler and NCD thinner (Sheenlac make), pasting chalk putty, applying sealer (Sheenlac make) and wall nut colour stainer and finally applying waxpol (Silicon make), fixed in repairs complete all as specified and as directed.\n\n 13 SQM
50 50 S&F corner glass shelf with brackets, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. AQN-1173 or equivalent in PRAYAG/PARRYWARE\n 6 EACH
51 51 S&F tubular towel rail, brass, chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. AQN-7711 or equivalent in PRAYAG/PARRYWARE\n 6 EACH
52 52 S&F towel ring (round), brass, chromium plated with round flange, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. AQN-7721 or equivalent in PRAYAG/PARRYWARE 6 EACH
53 53 S&F 5.5mm thick looking mirror mounted on 6mm thick marine ply fixed to 50mm wide x 18mm thick rubber wood designed frame including sanding and applying mixture of filler and NCD thinner (Sheenlac make), pasting chalk putty, applying sealer (Sheenlac make) and wall nut colour stainer, spraying melamine polish (Berger/Sheenlac make) and finally applying waxpol (Silicon make) including taking down old damaged mirror complete all as specified and as directed., 3 SQM
54 54 S&F PVC cabinet of size 550mm x 520mm x 100 mm having 2 Nos sliding mirror of 4mm thick and size 240mm x 290mm with built-in rack of size 230mm x 150mm x 90mm and CP towel rail of 270mm long with PVC plugs etc., fixed in repairs complete all as specified and as directed.\nMAKE: SUPREME/PRAYAG 6 EACH
55 55 S&F bib tap, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. CON-107KN or equivalent in PRAYAG/PARRYWARE 6 EACH
56 56 S&F pillar tap, brass, 15mm dia, chromium plated, fancy type with capstan heads, screwed down, high pressure, long neck with aerator, screwed for iron pipe, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. ALI-85001 6 EACH
57 57 S&F concealed stop cock, 15mm dia, cast copper alloy, with wall flange including all fittings fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. CON-083KN\n 6 EACH
58 58 S&F two way bib cock, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for unions, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. CON-041KN or equivalent in PRAYAG/PARRYWARE\n 6 EACH
59 59 S&F soap dish holder, brass, chromium plated, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. AQN-7731 or equivalent in PRAYAG/PARRYWARE 6 EACH
60 60 S&F health faucet, brass, chromium plated with 8mm dia, 1.0 m long flexible tube with wall hook, screwed for iron pipe or for brass ferrule 15mm dia or bore, fixed in repairs complete all as specified and as directed.\nMAKE: ZIM Cat part No. 1624A or equivalent in PRAYAG/PARRYWARE 6 EACH
61 61 S&F wall mixer 3-in-1 system with provision of both hand shower and over head shower composite with 115mm long bend pipe connecting legs & wall flanges with and including hand shower with 8mm dia shower tube, 450mm long shower arm and over head shower, fixed in repairs complete all as specified and as directed.\nMAKE: \nJAQUAR Cat part No. CON-281KN or equivalent in PRAYAG/PARRYWARE\n 6 EACH
62 62 S&F WHB mixer, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, with long shank with central hole screwed down, screwed both ends for iron pipe or for unions, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. CON-167KNB or equivalent in PRAYAG/PARRYWARE\n 6 EACH
63 63 S&F over head shower, 15mm dia, cast copper alloy, chromiun plated, 105mm dia of shower with revolving joints (with body rotation) & 115mm long arm shower with rabit cleaning system including all fittings, screwed down for iron pipe or for unions, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. OHS-1709 or equivalent in PRAYAG/PARRYWARE 6 EACH
64 64 S&F toilet paper holder, brass, chromium plated, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. CAN-1153N or equivalent in PRAYAG/PARRYWARE 6 EACH
65 65 M&L for vitreous China, wash down water closet pan (pedestal pattern), white colour, standard size with necessary fitments including fixing bolts and connecting to existing flushing cistern and making good disturbed surfaces to match with suroundings, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. LYT WHT-0314 or equivalent in PRAYAG/PARRYWARE 5 EACH
66 66 M&L for vitreous China wash hand basin, white, flat back, size 550mm x 400mm including cutting for and pinning in ends of brackets or erecting stand, 32mm dia waste coupling brass chromium plated, PVC waste pipe of suitable length, chain and plug, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. CNS WHT-WB 02 or equivalent in PRAYAG/PARRYWARE\n 5 EACH
67 67 M&L for PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets and connecting to WC, fixed in repairs complete all as specified and as directed. 6 EACH
68 68 S&F 125mm dia CP grating doom with or without waste hole fixed over floor/Nahani trap in white cement in repairs complete all as specified and as directed. 6 EACH
69 69 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. 7 CUM
70 70 M&L for plain cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in roof padding/ sunken floors and similar work complete all as specified and as directed.\n 7 CUM
71 71 M&L for screed bed 12mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over RCC roof slabs, surfaces finished fair and even complete all as specified and as directed.\nNOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule. 70 SQM
72 72 M&L for preparing plastered surfaces and applying a coat of cold applied bituminous primer over cleaned roof/ sunken surface @ 0.30 Kg/sqm and applying one coat of hot blown bitumen 85/25 grade @ 1.2 Kg/Sqm over primer followed by 3 mm thick APP modified polymeric water proofing membrane weighing not less than 3.0 Kg/sqm reinforced with polyester non-woven fabric weighing not less than 150 grams/sqm laid as per the manufacturer instructions with side over lap of 75mm & end over lap of 100mm & tucked into the chases on roof, sunken slabs, edges and vertical surfaces and finally finishing the APP membrane surface with bituminous aluminium paint @ 0.30 Kg/sqm complete all as specified and directed.\nMAKE: STP Limited/ PIDILITE INDUSTRIES LIMITED (Dr. FIXIT TORCHSHIELD P3160)/ IWL INDIA LTD\n 70 SQM
73 73 Taking down of damaged, loosened cement concrete/cement mortar in walls and similar structural members up to depth of 20 mm, cleaning the dismantled portion with wire brush etc remove dust , dirt and other foregin particals etc., and washing with water with pressure and applying bonding agent on old concrete surfaces all as specified and as per manufacturers instructions, Over prepared surfaces provide 20mm thick high build polymer modified cement sand mortar (1:2½) mixed with 5 litres (minimum) NITOBOND SBR per 50 kilograms of cement of M/s FOSROC Chemical (India ) Pvt Ltd or equivalent in Dr. Fixit or Harjas Coatings & Polymers including necessary scaffolding up to 15 m and including match the existing shade of suface complete all as specified and directed 65 SQM
74 74 Dismantling structural steel work as in frame work of any description complete all as specified and as directed. 6 QTL
75 75 M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.\n 300 KG
76 76 M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979, Grade St-240 complete all as specified and as directed. 200 KG
77 77 Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed. 75 SQM
78 78 S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based trapezoidal profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. \nNOTES: \nThe self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.\n 60 SQM
79 79 S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scoffolding for a height upto 12.0 metres complete all as specified and as directed. \nNOTES: \nThe self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.\n 15 SQM
80 80 S&F aluminum flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. \nNOTES: \nThe self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. 30 KG
81 81 Dismantling ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. 100 SQM
82 82 M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009 including provision of G.I. hangers 6 mm dia wire suspenders fixed with adjustable connectors including cutting, drilling, jointing etc., 4mm thick E-boards (Classic) 605mm x 605mm size fixed or laid/ inserted to aluminium frame work with screws and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.\n 70 SQM
83 83 M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed. 30 SQM
84 84 M&L for aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30.0 micron fixed over frame made up of aluminium hollow section of 25x50mm, 2.0mm thick, duly fixed to wall/ceiling with expansion fastner having panels not exceeding 1200x1200mm with necessary silicon filling, in approved pattern as in columns, beams, walls etc., complete all as specified and as directed.\nNOTE: Necessary scaffolding upto 8.0 metres required for the work shall be deemed to include in the unit rate quoted.\n 20 SQM
85 85 S&F angular stop cock, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for unions, fixed in repairs complete all as specified and as directed.\nMAKE: JAQUAR Cat part No. CON-053KN\n 6 EACH
86 86 Dismantling PVC (SWR)/ cast iron pipes of 110mm dia in any position alongwith all fittings and fixtures by removing at joints complete all as specified and as directed. 100 RM
87 87 S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.\n 100 RM
88 88 S&F PVC (SWR) bends any radius, diameter of outlet 110mm complete all as specified and as directed.\n 10 EACH
89 89 S&F PVC (SWR) bends with oval access door, any radius, diameter of outlet 150 mm complete all as specified and as directed.\n 10 EACH
90 90 S&F PVC (SWR) branch piece, single (single Y) equal or unequal, diameter of outlet 110 mm complete all as specified and as directed.\n 6 EACH
91 91 S&F PVC (SWR) vent cowl of diameter 110 mm complete all as specified and as directed.\n 10 EACH
92 92 Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed. 138 POINT
93 93 Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. 330 RM
94 94 Taking down existing unserviceable main switches/ distribution boards of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. 3 EACH
95 95 Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed. 92 EACH
96 96 M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE LIGHT/FAN point controlled by one, one way 6 Amps switch. 30 POINT
97 97 M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE BELL point controlled by one, one way 6 Amps switch. 3 POINT
98 98 M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent board. 17 POINT
99 99 M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on same board. 11 POINT
100 100 M&L for Point wiring complete with 2.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps switch on independent board. 11 POINT
101 101 S&F switch piano, flush type, single pole, one way, 6 Amps, 240 volts complete all as specified and as directed.\n\n\n 58 EACH
102 102 S&F bell push, flush type, single pole, one way, 6 Amps, 240 volts complete all as specified and as directed.\n\n\n 3 EACH
103 103 S&F switch socket outlet, 5 pin, 6A, flush type, multipurpose, 240 volts complete all as specified and as directed.\n 100 EACH
104 104 S&F switch socket outlet, 2-in-1, 6 pin, 6A/16A, flush type, multipurpose, 240 volts complete all as specified and as directed.\n 100 EACH
105 105 S&F electronic fan regulator for ceiling fan, step type, 5 speed, AC, 120 watts, 230 volts complete all as specified and as directed. \n 15 EACH
106 106 S&F electric bell, ding dong type, AC, 230 volts complete all as specified and as directed. \n 3 EACH
107 107 M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.\n 30 EACH
108 108 M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch. 20 POINT
109 109 M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE BELL point controlled by one, one way 6 Amps modular switch. 6 POINT
110 110 M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on independent board. 20 POINT
111 111 M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on same board with other switches. 10 POINT
112 112 M&L for Point wiring complete with 2.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board. 10 POINT
113 113 S&F modular switch, one way, one module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed. \n\n\n 50 EACH
114 114 S&F modular socket, multipurpose, 2/3 pin combined, 2 module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed.\n 10 EACH
115 115 S&F modular socket, multipurpose, 2/3 pin, 6/16 Amps combined, 2 module, single pole, 240 Volts ACcomplete all as specified and as directed.\n 10 EACH
116 116 S&F modular switch, one way, one module, single pole, 16 Amps, 240 Volts AC complete all as specified and as directed. \n 10 EACH
117 117 S&F modular bell push, one way, one module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed. \n\n\n 6 EACH
118 118 S&F modular electronic fan regulator for ceiling fan, step type, 5 speed, AC, 2 module, 120 watts, 240 volts complete all as specified and as directed. \n 8 EACH
119 119 M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed.\nNOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. 105 RM
120 120 M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed.\nNOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. 225 RM
121 121 Taking down carefully ceiling fan of any sweep from ceiling hook at any height after disconnecting from electricity, dismantling blades, opening up for carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade and writing MES No. in synthetic enamel paint, fixing up blades and hanging back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed.\nNOTE: Spare parts like ball bearings, shafts, fan blades, copper winding shall be replaced only if found damaged and certified by Engineer-in-charge. If spares are replaced, they shall be measured and paid separately as SUPPLY ONLY. A book shall be maintained for record of servicing and replacement of spares with MES Nos. of fans. 13 JOB
122 122 Taking down carefully exhaust fan/ wall mounting fans of any sweep from its position at any height after disconnecting from electricity, dismantling blades, opening up for carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade and writing MES No. in synthetic enamel paint, fixing up blades and fixing back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed.\nNOTE: Spare parts like ball bearings, shafts, fan blades, copper winding shall be replaced only if found damaged and certified by Engineer-in-charge. If spares are replaced, they shall be measured and paid separately as SUPPLY ONLY. A book shall be maintained for record of servicing and replacement of spares with MES Nos. of fans. 13 JOB
123 123 Rewinding of ceiling fan (any sweep) stator by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in ceiling fan complete all as specified and as directed. 13 EACH
124 124 Rewinding of exhaust fan by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in exhaust fan complete all as specified and as directed. 9 EACH
125 125 Rewinding of wall mounted fan by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in exhaust fan complete all as specified and as directed. 8 EACH
126 126 SUPPLY ONLY sealed ball bearing suitable for ceiling fan with bearing No. 6201/6202 complete all as specified and as directed. 10 EACH
127 127 S&F capacitor 2.5mfd, 230 Volts for ceiling fans including taking out old unserviceable one complete all as specified and as directed.\nMAKE: CAPCO/UNIVERSAL/TIBCON/EPCOS 35 EACH
128 128 S&F Starter switch of capacity 25 Amps, working on 240 volts, AC supply, suitable for air conditioner complete all as specified and as directed. \nMAKE: Crabtree Cat part No. ACTO252504 or equivalent in ANCHOR/ L&T/ HAVELLS 8 EACH
129 129 S&F MCB DB, SPN, 8-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-54 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.\nMAKE: INDO ASIAN Cat part No. 811826 or equivalent in L&T/ LEGRAND/ HAVELLS 3 EACH
130 130 S&F MCCB, 4 pole, 125 Amps, 50Hz, 16KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed.\nMAKE: INDO ASIAN Cat part No. 830243 or equivalent in L&T/ LEGRAND/ HAVELLS 2 EACH
131 131 S&F MCB, SPN, "C" series, 230 volts, 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. \nMAKE: INDO ASIAN Cat part No. 811151 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS\n 3 EACH
132 132 S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. \nMAKE: INDO ASIAN Cat part No. 811122 to 811129 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS 18 EACH
133 133 S&F 18 Watts, 220 Volts recess mounting LED ceiling light fitting, 178mm dia size round/square shaped, made from die-cast aluminium and CRCA covering, powder coated in white colour suitable for armstrong/grid ceiling complete with separate electronic driver complete all as specified and directed.. \nMAKE: PHILIPS, Model: Astra Max Metal Panel or equivalent in HAVELLS/ CROMPTON GREAVES \nNOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting 15 EACH
134 134 S&F 15 Watts, 220 Volts recess mounting LED ceiling light fitting, 159mm size round/square shaped, made from die-cast aluminium and CRCA covering, powder coated in white colour suitable for armstrong/grid ceiling complete with separate electronic driver complete all as specified and directed.. \nMAKE: PHILIPS, Model: Astra Max Metal Panel or equivalent in HAVELLS/ CROMPTON GREAVES \nNOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting 23 EACH
135 135 S&F LED tube light fittings of 14 Watts capacity, 230 Volts, 50 Hz AC supply, batten type, extruded aluminium housing with diffuser including all accessories and fixing arrangements, fixed to wall/ceiling, surface mounted including 14 Watts LED tube light and testing complete all as specified and as directed.\nMAKE: CROMPTON GREAVES Cat part No. LCL 14 CDL or equivalent in HAVELLS/ C&S/PHILIPS 6 EACH
136 136 Taking down old unserviceable T-5 FTL fittings 28 watt and S&F decorative cute lines LED light fixture of 20 Watts capacity, T-5 FTL fittings, 6500K, 230 Volts, 50 Hz AC supply, warm white with extruded aluminium heat sink, environmental friendly energy efficient light fitting, surface mounted including 20 Watts LED lamp and testing complete all as specified and as directed.\nMAKE: CROMPTON GREAVES Cat part No. CCS-100-20-65-HL2-DP-NWH or equivalent in PHILIPS/HAVELLS/ WIPRO 48 EACH