Repair Maintenance Of External Electric Supply Such As Repair To Ht 11 Kv Vcb Transformers Apfc Panels Alongwith Allied Works In Navy And Coast Guard Units Under Ge Navy Lakshadweep, KAVARATTI ANDROTH-Lakshadweep

Military Engineer Services-MES has published Repair Maintenance Of External Electric Supply Such As Repair To Ht 11 Kv Vcb Transformers Apfc Panels Alongwith Allied Works In Navy And Coast Guard Units Under Ge Navy Lakshadweep. Submission Date for this Tender is 14-11-2020. Electrification Work Tenders in KAVARATTI ANDROTH Lakshadweep. Bidders can get complete Tender details and download the document.




Tender Notice

25836878
Repair Maintenance Of External Electric Supply Such As Repair To Ht 11 Kv Vcb Transformers Apfc Panels Alongwith Allied Works In Navy And Coast Guard Units Under Ge Navy Lakshadweep
Open Tender
Indian
Lakshadweep
KAVARATTI ANDROTH
14-11-2020

Tender Details

Repair Maintenance Of External Electric Supply Such As Repair To Ht 11 Kv Vcb Transformers Apfc Panels Alongwith Allied Works In Navy And Coast Guard Units Under Ge Navy Lakshadweep

Key Value

Document Fees
INR 500 /-
EMD
INR 69000.0 /-
Tender Value
INR 34.50 Lakhs /-

BOQ Items

Name of Work : REPAIR MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY SUCH AS REPAIR TO HT 11KV VCB, TRANSFORMERS,APFC PANELS ALONGWITH ALLIED WORKS IN NAVY AND COAST GUARD UNITS AT KAVARATTI AND ANDROTH UNDER GE (NAVY) LAKSHADWEEP.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Topping up and complete renewal of Transformer oil complete all as specified and as directed by Engineer in charge. Minimum breakdown strength of transformer oil shall not be less than 65 KV/Min for oil cooled Transformer. Make:- Power oil/Servo or any other BIS approved make as approved by GE. 350 Litre
2 2 Supply and Fix in replacement Transformer Tap changer made of Brass material for regulating LT voltage, suitable for existing Transformer of capacity 100 KVA complete all as specified and as directed by Engineer in charge. Make:- CG/Legrand/Schnieder as approved by Engineer in charge. Make:- L&T/Seimens/C&S/Legrand as approved by GE. 1 Each
3 3 Disconnecting and taking down the Transformer of 100 KVA capacity from the existing position and transporting to work shop and opening the outer cover, draning out the oil and lifting the core along with winding, finding the faulty/burnout primary and secondary winding and rewinding with fine enameled insulated copper winding of same size/gauge, turns keeping in hot air oven till the moisture evoporates, reassembling the transformer parts such as core, winding, outer cover, refilling back the Transformer oil complete and transporting back to its original position and reconnecting the LT/HT cable connections complete all as specified and as directed by Engineer in Charge. 1 Each Job
4 4 Disconnecting and taking down the Transformer of 250 KVA capacity from the existing position and transporting to work shop and opening the outer cover, draning out the oil and lifting the core along with winding, finding the faulty/burnout primary and secondary winding and rewinding with fine enameled insulated copper winding of same size/gauge, turns keeping in hot air oven till the moisture evoporates, reassembling the transformer parts such as core, winding, outer cover, refilling back the Transformer oil complete and transporting back to its original position and reconnecting the LT/HT cable connections complete all as specified and as directed by Engineer in Charge. 1 Each Job
5 5 Dismantling & taking down the existing unserviceable /corroded LT Planel board and Supplying, Installing, testing and commissioning of factory made Outdoor type/Floor mounted CPRI approved thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire (1100x2050x700 mm) with 250 amps rated busbar internal wiring connection with suitable size copper cables and copper bus bar 20 x 3mm and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer comprising of following:-\n(i) On Load change over switch TPN 415V 160A 36kA-01 (incoming)\n(ii) MCCB TPN 415V 100A 36kA-03 (outgoing)\n(iii) MCB TPN 415V 63 amps 10 KA - 04 Nos\n(iv) Digital voltmeter 0-500 V 01 No\n(v) Digital ammeter with Cts 250 amps- 01 No\n(vi) Tamper proof digital KWH enery meter with CTs - 01 No (vii) Indicator lamp LED type 240V AC (RYB) - 01 set \nNote :-\n(a) The rate quoted by the bidder is inclusive of taking down the existing steel panel from founadation, disconnecting cable and handing over old MCCBs retrived from the panel to MES including transportation cost and supplying, fixing and testing of New LT feeder pillar box\n(b) LT feeder pilar box shall be manufactured by M/s Hansel approved by CPRI and test certficate shall be produced by the contractor from the manufacturer. 2 Each Job
6 6 Dismantling & taking down the exisiting unserviceable /corroded LT Planel board Supply & Install, testing and commissioning factory made Outdoor type/Floor mounted made of CRCA sheet of thickness not less than 3mm CPRI approved feeder pillar box IP 54 protection suitable for 3 phase 4 wire with 400 Amps rated busbar internal wiring connection with suitable size and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer including PCC foundation to accommodate and comprising of following:-\n(i) MCCB TPN 415V 160A 36kA-01 (incoming)\n(ii) MCCB TPN 415V 63A 36kA-02 (outgoing)\n(iii) MCB TPN 415V 32 amps 10 KA - 1 No (outgoing)\n(iv) Digital voltmeter 0-500 V 01 No\n(v) Digital ammeter with Cts 250 amps- 01 No\n(vi) Indicator lamp LED type 240V AC (RYB) - 01 set\nNote :- (a) The rate quoted by the bidder is inclusive of taking down the existing steel panel from founadation, disconnecting cable and handing over old MCCBs retrived from the panel to MES including transportation cost and supplying, fixing and testing of New LT feeder pillar box\n(b) LT feeder pilar box shall be manufactured by M/s Hansel approived by CRPI and test certificate shall be produced by the contractor from the manufacturer. 1 Each Job
7 7 Disconnecting and taking down unserviceable power contactor and Supplying,fixing and testing of new Power Contactor MCX 11 ,with coil voltage 240 V AC 50 Hz complete all as specified and as directed by Engineer in Charge. Make:- L&T/Seimens/C&S/Legrand as approved by GE. 4 Each
8 8 Disconnecting and taking down unserviceable power contactor and Supplying, fixing and testing of new Power Contactor MCX 22 ,with coil voltage 240 V AC 50 Hz complete all as specified and as directed by Engineer in Charge. Make:- L&T/Seimens/C&S/Legrand as approved by GE. 3 Each
9 9 Disconnecting and taking down unserviceable power contactor and Supplying, fixing and testing of new Power Contactor MCX 33 ,with coil voltage 240 V AC 50 Hz complete all as specified and as directed by Engineer in Charge. Make:- L&T/Seimens/C&S/Legrand as approved by GE. 2 Each
10 10 Supply and Fix in replacement of three phase power contactor with coil voltage 240V , current 160A, 440 V, (2NO+2NC) type 3 Pole 50 Hz and testing complete all as specified and as directed by Engineer in Charge. Make : L & T Model MNX 110 or its equivalent in C&S /Seimens compatible with existing make and as approved by GE 4 Each
11 11 Supply and Fix in replacement of three phase power contactor with coil voltage 240V ,current 160A , 440 V type 3 Pole 50 Hz and testing complete all as specified and as directed by Engineer in Charge. Make : L & T Model MNX 70 or its equivalent in C&S /Seimens compatible with existing make and as approved by GE. 2 Each
12 12 Repairs and servicing of HT 11 KV VCB of current rating upto 630Amps capacity type by drawing out breaker assembly from panel and carry out the following work :- (i) Cleaning/ decarburizing of all fixed and moving contacts, levers, springs using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc, \n(ii) Adjust the trolley in and out mechanism , (iii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, automatic shuttering system, necessary brazing, turning, polishing of main and auxiliary contact, demoisturing of insulators, etc to be done (iv) Checking all end terminals, Tighting the nut bolt and washers, replace the unserviceable nut, bolt & washers, draw-in the breaker, put in position, engage the VCB with the supply system and testing for smooth functioning complete all as specified and as directed by Engineer in Charge. \nNote1 : Cost of unserviceable spare parts such as Charging motor,EFR,Aux relays, Vertical connection adapter , Fixed/Moving contacts ,Battery backup etc.. will be measured and paid under respective items\nNote2 : Primary/Secondary injection Test Kit and Insulation testing equipment shall be arranged by the contractor and rate deemed to be included the unit rate. \nMake: M/s Siemens India Ltd / Shneider/ABB as approved by GE 2 Each Job
13 13 Supply and Fix Earth relay suitable for M/s Siemens India Ltd HT 11 KV VCB including taking down old unserviceable one complete all as specified and as directed by Engineer in charge. Make- Seimens or Equivalent in schneider/ABB/L&T compatible with existing make and as approved by GE. 1 Each
14 14 Supply and Fix Auxilary relays suitable for M/s Siemens India Ltd HT11 KV VCB including taking down old unserviceable one complete all as specified and as directed by Engineer in charge. Make- Seimens or Equivalent in schneider/ABB/L&T compatible with existing make and as approved by GE. 1 Each
15 15 Supply and Fix Charging motor, operates on single Phase 230 V AC,50 Hz power supply for auto charging of HT breaker suitable for M/s Siemens India Ltd HT11 KV VCB including taking down old unserviceable one complete all as specified and as directed by Engineer in charge. Make- Seimens or Equivalent in schneider/ABB/L&T compatible with existing make and as approved by GE. 1 Each
16 16 Disconnecting and Removing of old serviceable Power pack unit and Supplying, installation & commissioning of Power Pack unit of Input 230 V AC, Output 24 V DC for H.T VCB Panel as required complete all as specified and as directed by Engineer in charge. Make :- MEGHAWIN/AREVA/SIEMENS/ABB as approved by GE. 1 Each Job
17 17 Supply and Fix in replacement Battery 12 Volts 150 AH complete all as specified and as directed by Engineer in charge. Make - exide/Amaron/Standard farukwa/AMCO as approved by GE. 2 Each
18 18 Supply and fix in replacement of MCCB of capacity 63 A ,4 P 415 V , 50 Hz ,10KA Conforming to IS/IEC 60947-2 & IEC 60947-2 with adjustable thermal setting: 0.8-1.0 x In along with necessary fixing arrangements complete all as specified and as directed by Engineer in charge. Make:- Siemens/Schneider/Havells/Legrand as approved by GE. 2 Each
19 19 Supply and fix in replacement of MCCB of capacity 100 A ,4 P 415 V , 50 Hz ,25KA Conforming to IS/IEC 60947-2 & IEC 60947-2 with adjustable thermal setting: 0.8-1.0 x In along with necessary fixing arrangements complete all as specified and as directed by Engineer in charge. Make:- Siemens/Schneider/Havells/Legrand as approved by GE. 4 Each
20 20 Supply and fix in replacement of MCCB of capacity 250A ,4 P 415 V , 50 Hz ,50KA Conforming to IS/IEC 60947-2 & IEC 60947-2 with adjustable thermal setting: 0.8-1.0 x In along with necessary fixing arrangements complete all as specified and as directed by Engineer in charge. Make:- Siemens/Schneider/Havells/Legrand as approved by GE. 8 Each
21 21 Supply and fix in replacement of MCCB of capacity 400 A ,4 P 415 V , 50 Hz ,50KA Conforming to IS/IEC 60947-2 & IEC 60947-2 with adjustable thermal setting: 0.8-1.0 x In along with necessary fixing arrangements complete all as specified and as directed by Engineer in charge. Make:- Siemens/Schneider/Havells/Legrand as approved by GE. 3 Each
22 22 Supply and fix in replacement 3 phase power factor capacitor of capacity 25 KVAr, 440 V, 50 Hz and testing complete all as specified and as directed by Engineer in charge. Make : L & T/ C & S /Seimens as approved by GE. 4 Each
23 23 Supply and fix in replacement 3 phase power factor capacitor of capacity 15 KVAr, 440 V, 50 Hz and testing complete all as specified and as directed by Engineer in charge. Make : L & T/ C & S /Seimens as approved by GE. 6 Each
24 24 Supply and fix in replacement 3 phase power factor capacitor of capacity 10 KVAr, 440 V, 50 Hz and testing complete all as specified and as directed by Engineer in charge. Make : L & T/ C & S /Seimens as approved by GE. 6 Each
25 25 Supply and fix in replacement 3 phase power factor capacitor of capacity 5 KVAr, 440 V, 50 Hz and testing complete all as specified and as directed by Engineer in charge. Make : L & T/ C & S /Seimens as approved by GE. 2 Each
26 26 Supply and Fix in replacement Powerfactor controller control circuit Board (PCB) for auto switching (on/off) of power capacitors along with internal pre wiring complete all as specified and as directed by Engineer in charge. Make : C&S/L&T/Seimens/ABB as approved by GE. 2 Each
27 27 Supply and Fix in replacement Digital type Voltmeter for measurement of three phase voltages having accuracy Class-1 with necessary PT connections in LT Panel board complete all as specified and as directed by Engineer in Charge. Make : Schnider/ABB/Legrand/C&S/Seimens as approved by GE. 2 Each
28 28 Supply and Fix in replacement Digital type Ammeter for measurement of three phase currents with necessary CT connections in LT Panel board complete all as specified and as directed by Engineer in Charge. Make : Schnider/ABB/Legrand/C&S/Seimens as approved by GE. 2 Each
29 29 Supply and Fix in replacement of Digital type multi function meter for monitoring / recording Single/three phase voltages ,currents, power ,powerfactor,KWh and frequency with necessary CT/PT connections in LT Panel board complete all as specified and as dierectd by enginer in charge. Make:- L&T Model:3p4w accuracy CLASS1 or its equivalent in C&S/Siemens/ABB/CG as approved by GE. 5 Each
30 30 Supply and Fix in replacement of ON LOAD CHANGEOVER SWITCH three phase 440V ,4 P of current rating 160 A with breaking capacity 36KA along with necessary fixing arrangements complete all as specified and as directed by Engineer in charge. Make : L&T Model:CO2-200 or its equivalent in C&S/Siemens/ABB/CG as approved by GE. 2 Each
31 31 Supply and Fix in replacement of ON LOAD CHANGEOVER SWITCH three phase 440V ,4 P of current rating 250 A with breaking capacity 36KA along with necessary fixing arrangements complete all as specified and as directed by Engineer in charge. Make : L&T Model:CO2-200 or its equivalent in C&S/Siemens/ABB/CG as approved by GE. 2 Each
32 32 Supply and fix cable jointing kit, heat shrinkable, for 1.1 kV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½ / 4 core XLPE armoured Aluminium conductor cable of size 16 to 50 sq mm complete all as specified and directed by Engineer in charge. Make:- Densen/Birla 3M as approved by Engineer in charge. 8 Each
33 33 Supply and fix cable jointing kit, heat shrinkable, for 1.1 kV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½ / 4 core XLPE armoured Aluminium conductor cable of size 70 to 90 sq mm complete all as specified and directed by Engineer in charge. Make:- Densen/Birla 3M as approved by Engineer in charge. 6 Each
34 34 Material and Labour for Indoor type jointing kit heat shrinakable for 11KV grade UG cable end termination with 3 core Aliminium conductor complete along with jointing material all as specified and as directed of size 185 Sqmm complete all as specified and as directed by Engineer in Charge. Make:- Raychems/Densons/MSeal/Birla 3M as approved by GE. 6 Each
35 35 Material and Labour for Outdoor type Straight through, jointing kit, heat shrinakable for 11KV grade UG cable with 3 core Aliminium conductor complete along with jointing material all as specified and as directed of of size 185 Sqmm complete all as specified and as directed by Engineer in Charge. Make:- Raychems/Densons/MSeal/Birla 3M as approved by GE. 4 Each
36 36 Supply and fix in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,3 core, 11000 volts, grade of the size 185 Sqmm complete all as specified and as direcetd by Engineer in Charge .Make : Havells / Polycab /Gloster as approved by GE. 70 RM
37 37 Supply and fix in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,3 core, 11000 volts, grade of the size 95 Sqmm complete all as specified and as direcetd by Engineer in Charge .Make : Havells / Polycab /Gloster as approved by GE. 30 RM
38 38 Supply and fix in replacement XLPE insulated, PVC sheath, armoured, heavy duty electric cable with aluminium conductor, 1100 vots grade, cross sectional area 16 sqmm 4 core complete all as specified and as directed by Engineer in charge. Make:- Havells/Polycab/Gloster as approved by GE. 200 RM
39 39 Supply and fix in replacement XLPE insulated, PVC sheath, armoured, heavy duty electric cable with aluminium conductor, 1100 vots grade, cross sectional area 25 sqmm 3.5/4 core complete all as specified and as directed by Engineer in charge. Make:- Havells/Polycab/Gloster as approved by GE. 350 RM
40 40 Supply and fix in replacement XLPE insulated, PVC sheath, armoured, heavy duty electric cable with aluminium conductor, 1100 vots grade, cross sectional area 50 sqmm 3.5/4 core complete all as specified and as directed by Engineer in charge. Make:- Havells/Polycab/Gloster as approved by GE. 150 RM
41 41 Supply and fix in replacement XLPE insulated, PVC sheath, armoured, heavy duty electric cable with aluminium conductor, 1100 vots grade, cross sectional area 70 sqmm 3.5/4 core complete all as specified and as directed by Engineer in charge. Make:- Havells/Polycab/Gloster as approved by GE. 190 RM
42 42 Supply and lay burnt bricks sub class 'B' for cable protection complete all as specified and as directed by engineer in charge. 5.5 1000Nos
43 43 Supply and laying unreinforced pre cast concrete cable cover class HVP type 1 with peak flat size 300 x 180 x 40 mm for cable protection complete all as specified and as direcetd by Engineer in Charge. 200 Each
44 44 M&L for sand cushioning with Sand in two layers, first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cables including consolidation of each layer complete all as specified and as directed by Engineer in charge. Note:-Thickness of sand cushioning shall be measured after punning. 44 Cum
45 45 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 depth and getting out in soft/loose soil for laying cables/pipes/erection of poles etc. complete all as specified and as directed by Engineer in charge. 207 Cum
46 46 Returning filling in, with excavated soils including, spreading, levelling, watering and well ramming in layers n.exc. 25 Cms. complete all as specified and as directed by Engineer in charge. 143 Cum
47 47 Removing excavated material/ surplus soil exceeding 250m and n.exc. 500m and depositing where directed at a level n.exc. 1.50m above the starting point complete all as specified and as directed by Engineer in charge. 64 Cum
48 48 Material and Labour for concrete cutting in ground floors/pavings/road n.exc 15 cm depth (below ground level) for laying pipes complete all as specified and as directed by Engineer in charge. 5 Cum
49 49 Material and Labour for cement concrete type B-2,1:2:4(40 mm graded aggregate) upto 100mm thickness for making good to area of concrete road/floor/pavings cut complete all as specified and as directed by Engineer in charge. 2 Sqm
50 50 Supplying and Laying GI pipe light grade of dia 80mm for cable protection complete including takingdown old unserviceable pipe complete all as specified and as directed by Engineer in charge. 15 RM
51 51 Supplying and Laying GI pipe light grade of dia 50mm for cable protection complete including takingdown old unserviceable pipe complete all as specified and as directed by Engineer in charge. 10 RM