Steel Industrials Kerala Limited has published Construction Of Truss Work At Main Block In Government Arts And Science College , Kozhikode-18 Construction Of Truss Work At Main Block InGovernment Arts And Science College , Kozhikode-18. Submission Date for this Tender is 02-11-2020. Building Work Tenders in Kozhikode Kerala. Bidders can get complete Tender details and download the document.
Name of Work:Construction of Truss Work at Main Block in Govt Arts and Science College,Kozhikode-18 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | 10.16.1\nSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including\ncutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding\nand bolted with special shaped washers etc. complete.Hot finished welded type tubes ,should ISI Specified brand(appolo/G-mac/Avt or any other approved brand) all works should be done as per the direction of Engineer in charge. | BI01010001010000000000000515BI0100001113 | 14096.9 | kg |
2 | 2 | 15.23.1\nDismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres\nlead.For thickness of tiles 10 mm to 25 mm | BI01010001010000000000000515BI0100001114 | 117.28 | sqm |
3 | 3 | 10.21\nProviding and fixing M.S. rivets of sizes in position. | BI01010001010000000000000515BI0100001115 | 226.8 | kg |
4 | 4 | 5.2.2\nReinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth\nand string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level\nexcluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :\n3 graded stone aggregate 20mm nominal size.all works should be done as per the direction of Engineer in charge. | BI01010001010000000000000515BI0100001116 | 10.42 | cum |
5 | 5 | 5.9.5\nCentering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,\ngirders bressumers and cantilevers | BI01010001010000000000000515BI0100001117 | 84.48 | sqm |
6 | 6 | 5.22A.6\nSteel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and\nbinding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001118 | 883.41 | kg |
7 | 7 | od179980/2020_2021\nboring holes 10mm dia at an interval of 2 m spacing and providing 8mm dia steel bars for min 15cm or\n10cm depth and bend as hook over plinth beam | BI01010001010000000000000515BI0100001119 | 95 | nos |
8 | 8 | od184946/2020_2021\n16mm dia anchor bolt for vertical steel columns each should be drilled minimum 15cm in depth to a\nmaximum depth | BI01010001010000000000000515BI0100001120 | 492 | nos |
9 | 9 | 12.50\nProviding and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as\napproved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams\nper sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and\npolyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to\navoid scratches during transportation and should be supplied in single length upto 12 metre or as desired\nby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm)\nwith EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of\npurlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001121 | 1135.2 | sqm |
10 | 10 | 12.51.2\nProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total\ncoated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc\ncoating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both\nside of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws\ncomplete:Flashings / Aprons (Upto 600 mm) | BI01010001010000000000000515BI0100001122 | 86 | m |
11 | 11 | 13.52.1\nFinishing with Epoxy paint (two or more coats) at all locations prepared and applied as per\nmanufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On\nsteel work | BI01010001010000000000000515BI0100001123 | 964.92 | sqm |
12 | 12 | od148355/2020_2021\nSupplying and fixing 150 mm dia PVC half gutter, fittings and wastage including cost and conveyance of\nall materials to site and all labour charges etc complete | BI01010001010000000000000515BI0100001124 | 174 | m |
13 | 13 | 12.14\nProviding flat iron brackets 50x3 mm size with necessary bolts, nuts and washers etc. for fixing asbestos\ncement / G.S. sheet gutters with purlins. | BI01010001010000000000000515BI0100001125 | 174 | m |
14 | 14 | 12.41.2\nProviding and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type\nA, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)\nSingle socketed pipes.110 mm diameter (Astral/supreme/Finolex or any other approved ISI certified brand) | BI01010001010000000000000515BI0100001126 | 950 | m |
15 | 15 | 12.42.1.2\nnullCoupler110 mm (Astral/supreme/Finolex or any other approved ISI certified brand) | BI01010001010000000000000515BI0100001127 | 60 | nos |
16 | 16 | 18.77\nCutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole\nafter insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone\naggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | BI01010001010000000000000515BI0100001128 | 180 | nos |
17 | 17 | 12.42.5.2\nProviding and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid\nPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :\n5382, leaving 10 mm gap for thermal expansionBend 87.5<sup>0</sup>110 mm bend (Astral/supreme/Finolex or any other approved ISI certified brand) | BI01010001010000000000000515BI0100001129 | 360 | nos |
18 | 18 | 12.42.6.2\nProviding and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid\nPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :\n5382, leaving 10 mm gap for thermal expansionShoe (Plain)110 mm Shoe (Astral/supreme/Finolex or any other approved ISI certified brand) | BI01010001010000000000000515BI0100001130 | 60 | nos |
19 | 19 | 12.38.1\nProviding and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I rain water pipes\nembedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse\nsand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the\nwalls etc:100 mm diameter.The clamps provided should be rustfree type. | BI01010001010000000000000515BI0100001131 | 950 | nos |
20 | 20 | 12.42.3.2\nSingle tee with door110x110x110 mm (Astral/supreme/Finolex or any other approved ISI certified brand) | BI01010001010000000000000515BI0100001132 | 30 | nos |