}

Reconstruction Of 11/Lt Kv Lines Fallen Due To Diffrent Reasons, Straightening Of Tilted Pole, Replacment Of Damaged X Arm, Pin Insulator, Disc Insulator, Clamp, Transformer Etc. & Re-Sagging Of Existing Loose Conductor, Tightening Of Stay N Fixing Of Ear, SE EDC Hathras-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Reconstruction Of 11/Lt Kv Lines Fallen Due To Diffrent Reasons, Straightening Of Tilted Pole, Replacment Of Damaged X Arm, Pin Insulator, Disc Insulator, Clamp, Transformer Etc. & Re-Sagging Of Existing Loose Conductor, Tightening Of Stay N Fixing Of Ear. Submission Date for this Tender is 31-10-2020. Clamps Tenders in SE EDC Hathras Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25802862
Reconstruction Of 11/Lt Kv Lines Fallen Due To Diffrent Reasons, Straightening Of Tilted Pole, Replacment Of Damaged X Arm, Pin Insulator, Disc Insulator, Clamp, Transformer Etc. & Re-Sagging Of Existing Loose Conductor, Tightening Of Stay N Fixing Of Ear
Open Tender
Indian
Uttar Pradesh
SE EDC Hathras
31-10-2020

Tender Details

Reconstruction Of 11 / Lt Kv Lines Fallen Due To Diffrent Reasons, Straightening Of Tilted Pole, Replacment Of Damaged X Arm, Pin Insulator, Disc Insulator, Clamp, Transformer Etc. & Re-Sagging Of Existing Loose Conductor, Tightening Of Stay N Fixing Of Earthing Road In M & R Scheem At 33 / 11 Kv Substations Under Eudd Hathras.

Key Value

Document Fees
INR 1180 /-
EMD
INR 2000.0 /-
Tender Value
INR 2 Lakhs /-

BOQ Items

Name of Work : The work of reconstruction of 11/LT KV lines fallen due to Diffrent reasons, Straightening of Tilted pole, Replacment of damaged X Arm, Pin Insulator, Disc Insulator, Clamp, Transformer etc. & Re-sagging of existing loose conductor, Tightening of Stay n Fixing of earthing road in M & R Scheem at 33/11 KV Substation's Under EUDD Hathras.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Carriage of following from 132 KV Hathras store center to 33/11 KV Substations through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50 Kms.) item1
2 1.01 8.5 Mtr. long PCC Poles. item2 15 No.
3 1.02 9/11 Mtr. S.T. Poles item3 35 No.
4 1.03 11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps and other required line material, if any. item4 20 Qtl.
5 2 Carriage of following from 132 KV Store center Hathras to 33/11 KV Substations through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) item5
6 2.01 16 KVA T/F item6 2 No.
7 2.02 25 KVA T/F, 63 KVA T/F, 100 KVA T/F item7 3 No.
8 3 Replacement of damaged poles 8.5 Mtr. long PCC pole by digging of pits in kharanja/mettalic roadand dismantling of all 11KV/LT accessories from the existing / damaged pole and erection of single new pole including fitting all accessories. item8 13 Job
9 4 Replacement of damaged poles 9/11 Mtr. Long ST pole by digging of pits in kharanja/mettalic road and dismantling of all 11KV/33 KV accessories from the existing / damaged pole and erection of single new pole including fitting of all accessories. item9 31 Job
10 5 Replacement of damaged Double pole on 8.5 meter long PCC Pole (first opening of all accessories & then removing damaged poles), re-erecting D/P including fixing of Disc Insulators with fitting and other LT/11 KV accessories as per RESPO manual and as per direction of supervising engineer, The double pole shall be grouted in ratio 1:4:8 (Cement, sand and brick ballast/ stone ballast) including cost of cement, sand, brick ballast/ stone ballast, stone pad as per actual requirement at site item10 1 Job
11 6 Replacement of damaged Double pole on 9/11 meter long ST Pole (first opening of all accessories & then removing damaged poles), re-erecting D/P including fixing of Disc Insulators with fitting and other 11 KV/ 33KV accessories as per RESPO manual and as per direction of supervising engineer. The double pole shall be grouted in ratio 1:4:8 (Cement, sand and brick ballast/ stone ballast) including cost of cement, sand, brick ballast/ stone ballast, stone pad as per actual requirement at site item11 2 Job
12 7 Straightening of tilted single PCC Poles in the existing lines as per direction of supervising engineer. item12 5 No.
13 8 Straightening of tilted single ST Poles in the existing lines as per direction of supervising engineer. item13 5 No.
14 9 Straightening of tilted Double Poles in the existing lines as per direction of supervising engineer. item14 1 No.
15 10 Replacement of following damaged accessoriess in 11 KV /LT line - item15
16 10.01 11 KV X-Arms, 11 KV Pin Insulators with Pin & Nut & Bolt , 'F' Clamp item16 35 Job
17 10.02 11 KV Disc Insulator With Fiting item17 35 No.
18 11 Erection and grouting of stays as per RESPO manual and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost. item18 15 No.
19 12 Fixing of earthing rod as per RESPO manual and as per direction of supervising engineer. item19 8 No.
20 13 Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer. item20
21 13.01 ACSR Weasal conductor item21 1650 Mtr.
22 13.02 ACSR Dog / Racoon Conductor item22 825 Mtr.
23 13.03 50/95/120 sqmm. Areal Bunch Conductor item23 495 Mtr.
24 14 Removal of Damaged/Burned LT dustribution boxes & fixing of New at already/Newly errected pole for giving supply to consumer by connecting consumer cables by using appropriated alumunium lugs tape N & B provided by conractor as per requirement. item24 8 No.
25 15 Re- sagging and stringing of existing following conductor in HT /LT line as per direction of supervising engineer. item25
26 15.01 ACSR Weasal conductor item26 1650 Mtr.
27 15.02 50/95/120 sqmm. Areal Bunch Conductor item27 495 Mtr.
28 15.03 ACSR Dog Conductor item28 825 Mtr.
29 16 Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer item29 25 No.
30 17 Installation of following T/F on newly constructed double pole in proper alignment direction & making HT/LT connection. item30
31 17.01 16 KVA T/F item31 2 No.
32 17.02 25 KVA T/F, 63 KVA T/F, 100 KVA T/F item32 3 No.
33 18 Re Guarding / Guarding of 11 KV line by laying, stringing, sagging and binding of 2 Nos. parallel GI wire 6 SWG after providing, fabrication and fixing of guarding angle and fabrication and fixing of X-guards (Tillis) of GI wire at distance of 3 Mtr. item33 5 Span
34 19 Digging of proper size of pit for following work of damaged steel support with the provision of temporary support :-\n Then reinforcement of steel support by welding of 04 Nos. 2 feet long M.S. angle iron of 50x50x6 mm. at equal distance around each pole & also welding of these angle iron with each other by providing M.S. flat of size 35x6 mm. in round. After this construction of round plinth of pole will be done with cement, sand and concrete in 1:3:6 ratio of size 450 mm. dia & 600 mm height (300 mm. under the ground + 300 mm. the ground). The plinth should be plastered with ½ inch thick cement and sand of ratio 1:4 & taper rounding the upper most part of the plinth.\n The rate will include all cost of material, labour and T&P etc. for completion of the above work which will be provided by the contractor at his own cost. item34 15 Nos
35 20 Construction of round plinth around the S.T. Poles / RS Joists / Rails will be done with cement, sand and concrete in 1:3:6 ratio of size 450 mm. dia & 600 mm height (300 mm. under the ground + 300 mm. the ground). The plinth should be plastered with ½ inch thick cement and sand of ratio 1:4 & taper rounding the upper most part of the plinth. The rate will include all cost of material, labour and T&P etc. for completion of the above work which will be provided by the contractor at his own cost. item35 15 Nos
36 21 Opening of service cable of consummers and re-fixing the same after re-saging of conductor. item36 165 No.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail