}

Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuthera Jaswala-I And Ii , Badehra Rajputan , Guglehar-I And Ii , Jadla-I And Mawa Sindhian Tehsil Ghanari Distt . Una ( Hp ) Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuther, Gagret-Himachal Pradesh

Irrigation And Public Health Department has published Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuthera Jaswala-I And Ii , Badehra Rajputan , Guglehar-I And Ii , Jadla-I And Mawa Sindhian Tehsil Ghanari Distt . Una ( Hp ) Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuther. Submission Date for this Tender is 04-11-2020. Rising Mains Tenders in Gagret Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25800005
Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuthera Jaswala-I And Ii , Badehra Rajputan , Guglehar-I And Ii , Jadla-I And Mawa Sindhian Tehsil Ghanari Distt . Una ( Hp ) Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuther
Open Tender
Indian
Himachal Pradesh
Gagret
04-11-2020

Tender Details

Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuthera Jaswala-I And Ii , Badehra Rajputan , Guglehar-I And Ii , Jadla-I And Mawa Sindhian Tehsil Ghanari Distt . Una ( Hp ) Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuthera Jaswala-I And Providing And Laying Of 200Mm Dia Gmserw Pipe For Rising Main And Supply And Errection Of Submersible Pumping Machinery For Tubewell Badehra Rajputan And Laying , Jointing And Testing Of 150Mm Dia Gms Pipe ( Medium Class ) And Supply And Errecttion Of S

Key Value

Document Fees
INR 800 /-
EMD
INR 87292.0 /-
Tender Value
INR 54.79 Lakhs /-

BOQ Items

Name of work :- Construction of 12 Nos T/Well in village Loharli -III, Kuthera Jaswala -I & II, Badehra Rajputan, Guglehar- I & II, Jadla- I and Mawa Sindhian tehsil Ghanari Distt. Una (HP) (SH:- Providing, Laying, Jointing and testing of 200 mm dia GMSERW pipe for R/Main & S/E of Submersible Pumping Machinery for T/Well Badehra Rajputan and Laying, Jointing and testing of 150 mm dia GMS pipe (Medium class) for & S/E of Submersible Pumping Machinery for T/Well Jadla- I)
Sl. No. Item Description Item Code / Make Quantity Units.
1 1 Excavation in foundation, trenches in earth work in all kinds of soil,such as pick work,jumper work.blasting work in hard rock and soft rock and in saturated soil etc. i/c all leads and lifts , stacking the excavated soil not more than 3 mtrs. clear form the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth, sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as per the direction of the Engineer-in-Charge. 1689.3 Cum.
2 2 Providing, laying, testing & commissioning at site in trenches bevelled ended BIS marked GMSERW pipe IS/ISO:3183-2007 Grade L210 or A confirming to relevent codes & specification its equivalent latest with up to date ammendments of following dia with steel grade MSERW pipe IS/ISO:3183-2007 Grade L210 or A, having wall thickness & per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.0 to 7.0 mtr. The pipe's ends shall be bevelled suitable for butt welding, The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments & shall be engraved with L210 or A, including all kinds of short pieces, bends etc. made from parent tube including flushing,cleaning and hydraulic testing complete in all respect to the entire satisfaction and direction of the Engineer-in-charge.The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments and jointed with M.S. flanges and butt welding (The cost of earth work in trenches, butt welded joints, MS flanges, welding of M.S. flanges, cost of nuts, bolts and washers of required size and cost of minimum 3 mm thick compressed asbestos fibre/ synthetic rubber gaskets to be measured and paid for separately) with in all leads and lifts and as per entire satisfaction of Engineer - in - charge
3 2.1 (i) 200 mm dia GMSERW pipe Grade L-210 or A , 4.80 mm wall thikness 1280 Rmt
4 3 Laying , jointing & testing in trenches of galvanised mald steel tube of following dia and grade confirming to IS 1239-2004 ( with latest amendments upto date) as per classification of pipes as specified below. The laying of piupe shall confirm to BIS 5822(with latest amendments upto date ) all kind of special such as bends of all degree to made from parents tube, short pieces,tail pieces all made from parent tube within all leads and lifts. (Earth work in trenches to be measured and paid seperately)
5 3.1 GMS pipe 150 mm dia (medium class) 1310 Rmtr.
6 4 Providing & welding of MS flanges confirming to table as specified below as per IS- 6392-1971 (latest with upto ammendment ) welding of MS flanges with plain ended GMS/ GMSERW pipe on both end ( The cost of GMS pipe to be measured & paid for seperately)according to relevent BIS standard The welding of flanges with pipes as per IS: 816-1965 with electrode as per IS: 814-1967 including required Nos. and size of M.S nuts and bolts as per IS: 1369-1967 and compressed asbestos fibre jointing geskets sheet not less than 3 mm thick as per IS; 2712-1965. The welding of flanges to be done on both faces in three layers(two inner & one outer) to make the joints leak proof and to the entire satisfaction of the Engineer - in -charge.
7 4.1 MS flange 200 mm dia Table -17 5 Pair
8 4.2 MS flange 200 mm dia Table -5 6 Pair
9 4.3 MS flange 150 mm dia Table -17 11 Pair
10 5 Providing circumferencial butt welded joints by electrical arc welding to following dia & class pipes,welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS- 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes in all leads and lifts to the entire satisfaction of Engineer- in- charge..
11 5.1 GMSERW pipe 200 mm dia 202 Joint
12 5.2 GMS pipe (Medium class) 150 mm dia 207 Joint
13 5.3 Submersible Puping Machinery for T/Well Badehra Rajputtan
14 6 Supply and errection of submersible pumping set of reputed make such as KSB/Calama/BS/Oswal / worthigton/ LUBI/ GROUNDFOS/HINDUSTAN/SEERAX/SABAR/Johnston/Amrut conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments,suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better liffe for shaft conforming to BIS specifications The pump shall be directly coupled to suber-sible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation 1 Each
15 6.01 Discharge, (Q) 23.02 LPS
16 6.02 Total Head ( H ) 141.95 Mts.
17 6.03 SWL in Tubewell 28.04 mtr. bgl.
18 6.04 R.L. point of discharge 505.10 mtr
19 6.05 R.L. of Pump House = 376.95 mtr
20 6.06 Seasonal fluctuation + draught condition + bowl assembly.9 mtrs.
21 6.07 Drawdown in Tubewell 6.40 mtrs.
22 6.08 R.L of lowest point of pumpset installation=145.51 mtrs
23 6.09 Static suction lift 43.44 mtrs.
24 6.1 Rising main Column pipe
25 6.11 Length 1280.00 mtrs Length 53.15 mtr
26 6.12 Dia 200 mm (4.80 mm thick) Dia 125 mm (M)
27 6.13 Class GMERW pipe Class GMS
28 6.14 iv) Pumping hours 8hours
29 6.15 v) Alititude of installations above M.S.L 422.00mtr
30 6.16 vi) Characteristic of water
31 6.17 a) Temperature 22 Deg Cel.
32 6.18 b)Turbidity __________________JTU
33 6.19 c) Allkanity _________________mg/1Ca Co3
34 6.2 d) Size of solids _______________ mm
35 6.21 e) others
36 6.22 vii) Depth of T/well 125.00 mtr
37 6.23 viii) Dia of T/well assembly 300/200 mm
38 6.24 ix) Length of assembly pipe 125.00 mtr
39 6.25 x) Dia of housing pipe 300/200 mm
40 6.26 xi) Length of housing pipe 300 mtr
41 6.27 OPERATING CONDITIONS
42 6.28 i) Type of current A.C Three phases.
43 6.29 ii) Frequency 50 Cycles/ Sec.
44 6.3 iii) Rated Voltage 415+/-15% Volts
45 6.31 iv) System of earthing Double Loop earthing as per BIS 3843-1987 latest
46 6.32 v) Speed of Revolution __________________ RPM 2900
47 6.33 MOTOR
48 6.34 i) Ref to BIS code BIS 9283-1979 with upto date amendments
49 6.35 ii) Type of enclousre of motr As per BIS :4691-1985 (latest)
50 6.36 iii) Mechnical out put in HP
51 6.37 iv) Class of insulation : Class B The motor should be able to withstand intial current of 2.50 times the rated current for two minutes without suffering damages of permanet deformations
52 6.38 PUMP
53 6.39 i) Ref to BIS code BIS 5659-1978 with upto date amendments
54 6.4 ii) Driver Type Electric drivern
55 6.41 iii) Operating Range -15%to +10% of Total head at duty point
56 6.42 iv) Deliver size of Pump ;---------- (to be quoted by tenderer)
57 7 Providing ICTP Main Switch with HRC fuses of Havell/L&Tmake and having capacity 30%extra of the operational rating as per IS : 4064-1978 with upto date amendments. ICTP Switch: i) Make: ii) Type: iii) Capacity: 200 Amp. 1 Each
58 8 Providing MS Sheet steel fabricated floor mounted switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Switch Board. i) Drawing. ii) layout Plan. 1 Each
59 9 MCB of L&T/Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB (1) Make (ii) Type iii) Range iv) Capacity. 200 Amp. 1 Each
60 10 ELCB of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB I) MAKE II) Type iii ) Range iv) Capacity 200 Amp. 1 Each
61 11 The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Voltage Monitor Relay I) MAKE II) Type iii ) Range 0-500 amp 1 Each
62 12 A.C. supply,voltmeter of recommended make L&T/Havell/AE/ of suitable range with selector switches as per IS ;1248-1983 with up to date latest amendments. Voltmeter I) MAKE II) Type iii ) Range 0-500 Amp 1 Each
63 13 AC supply ammeter of L&T /Havell / AE make of suitable range with selector switches and CIS operated as per IS :1248 ( P-I&II ) -1983 with upto date amendments. Ammeter I) MAKE II) Type iii ) Range 200/5 Amp 1 Each
64 14 Bus bar chamber of L&T / Hevells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments Three phase indicator lamps complete with toggle switches for Bus Bar Chamber individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Rating 1 Each
65 15 Capacitor of BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 16KVAR 1 Each
66 16 Providing suitable starter of Kilburn/L&T/ Havells/IMP make as per IS : 8544-1979 with'upto date amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release with or without 'initial oil filling as the case may be with single phase prventor as per IS ;1248 ( P-5)1983 with up to date amendments. Starter i) Type ii) Make 1 Each
67 17 Providing and fixing of double flange Cast Iron Sliuce valve of Leader / Kirloskar make for the Column pipe and capable of withstanding the normal seat pressure and as per IS 780-1984(Cast Iron) with latest ammendments PN 1.0 in Column pipe 125 mm dia. 1 Each
68 18 Providing and fixing of double flanged swing type cast iron Reflux valve of Kirloskar/Leader make having Bye pass arrangement on the rising main and capable of 'withstanding normal Seat Pressure as per IS:5312-1984 (P-I) (Cast Iron) with latest ammendmets PN 1.0 in R/main 200 mm dia. 1 Each
69 19 Providing pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. Pressure Gauge i)Make ii)Range. 1 Each
70 20 Supply of PVC 3 core copper cable jointless, flat water proof cable as per BIS 694-1998 latest with upto date amendments, suitable for the pumpsets offered from MCCB to motor including all other electrical equipments/ accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor . The type, size and make shall be subject to approval of HPSEB authorities. Submersible Cable i)Make. ii) Size. 50 mm Sq. 107 Mtr.
71 21 lowering of GMS Column pipe assembly 125 mm dia(MG) including MS flanges of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size 125 mm dia. ii) Class GMS. iii) length. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm) 53.44 Mtr.
72 22 Installation of all above items as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge. 1 Job
73 23 Providing and laying copper PVC insulated 3 core armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster/IEC/ICC/ EICO/National / Grandlay make including all othe accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable. Suppy side From meter of HPSEB to Bus Bar and Switch) i) Size 25 mm Sq. ii) Make finolox /Havells iii) Type armound power cable iv) Capacity v) Core. 3 1 Job
74 24 Providing and fixing double earthing with G.I. wire / plate of 600x600x6.3mm thick electrode complete with material such as thimble, nuts and bolts,charcoal,salt, 25x5mm copper strip as per IS 3043-1987 with upto date amendments for motors and other eletrical equipments and digging of pits etc. complete in all restect as per the dirction of the Engineer-in-Charge. Copper flat 25x3mm 1 Job
75 24.1 Submersible Puping Machinery for T/Well at Jadla-1
76 25 Supply and errection of submersible pumping set of reputed make such as KSB/Calama/BS/Oswal / worthigton/ LUBI/ GROUNDFOS/HINDUSTAN/SEERAX/SABAR/Johnston/Amrut conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments,suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better liffe for shaft conforming to BIS specifications The pump shall be directly coupled to suber-sible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation 1 Set
77 25.01 Discharge, (Q) 16.67 LPS
78 25.02 Total Head ( H ) 109.59 Mts.
79 25.03 SWL in Tubewell 12.20 mtr. bgl.
80 25.04 R.L. point of discharge 465.20 mtr
81 25.05 R.L. of Pump House = 420.00 mtr
82 25.06 Seasonal fluctuation + draught condition + bowl assembly.9 mtrs.
83 25.07 Drawdown in Tubewell 21.95 mtrs.
84 25.08 R.L of lowest point of pumpset installation=145.51 mtrs
85 25.09 Static suction lift 43.15 mtrs.
86 25.1 Rising main Column pipe
87 25.11 Length 1310.00 mtrs Length 53.15 mtr
88 25.12 Dia 150 mm (4.80 mm thick) Dia 125 mm (M)
89 25.13 Class GMS pipe Class GMS
90 25.14 iv) Pumping hours 8hours
91 25.15 v) Alititude of installations above M.S.L 422.00mtr
92 25.16 vi) Characteristic of water
93 25.17 a) Temperature 22 Deg Cel.
94 25.18 b)Turbidity __________________JTU
95 25.19 c) Allkanity _________________mg/1Ca Co3
96 25.2 d) Size of solids _______________ mm
97 25.21 e) others
98 25.22 vii) Depth of T/well 125.00 mtr
99 25.23 viii) Dia of T/well assembly 300/200 mm
100 25.24 ix) Length of assembly pipe 125.00 mtr
101 25.25 x) Dia of housing pipe 300/200 mm
102 25.26 xi) Length of housing pipe 300 mtr
103 25.27 OPERATING CONDITIONS
104 25.28 i) Type of current A.C Three phases.
105 25.29 ii) Frequency 50 Cycles/ Sec.
106 25.3 iii) Rated Voltage 415+/-15% Volts
107 25.31 iv) System of earthing Double Loop earthing as per BIS 3843-1987 latest
108 25.32 v) Speed of Revolution __________________ RPM 2900
109 25.33 MOTOR
110 25.34 i) Ref to BIS code BIS 9283-1979 with upto date amendments
111 25.35 ii) Type of enclousre of motr As per BIS :4691-1985 (latest)
112 25.36 iii) Mechnical out put in HP
113 25.37 iv) Class of insulation : Class B The motor should be able to withstand intial current of 2.50 times the rated current for two minutes without suffering damages of permanet deformations
114 25.38 PUMP
115 25.39 i) Ref to BIS code BIS 5659-1978 with upto date amendments
116 25.4 ii) Driver Type Electric drivern
117 25.41 iii) Operating Range -15%to +10% of Total head at duty point
118 25.42 iv) Deliver size of Pump ;---------- (to be quoted by tenderer)
119 26 Providing ICTP Main Switch with HRC fuses of Havell/L&Tmake and having capacity 30%extra of the operational rating as per IS : 4064-1978 with upto date amendments. ICTP Switch: i) Make: ii) Type: iii) Capacity: 125 Amp. 1 Each
120 27 Providing MS Sheet steel fabricated floor mounted switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Switch Board. i) Drawing. ii) layout Plan. 1 Each
121 28 MCCB of L&T/Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB (1) Make (ii) Type iii) Range iv) Capacity. 100 Amp. 1 Each
122 29 ELCB of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB I) MAKE II) Type iii ) Range iv) Capacity 125 Amp. 1 Each
123 30 The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Voltage Monitor Relay I) MAKE II) Type iii ) Range 0-500 amp 1 Each
124 31 A.C. supply,voltmeter of recommended make L&T/Havell/AE/ of suitable range with selector switches as per IS ;1248-1983 with up to date latest amendments. Voltmeter I) MAKE II) Type iii ) Range 0-500 Amp 1 Each
125 32 AC supply ammeter of L&T /Havell / AE make of suitable range with selector switches and CIS operated as per IS :1248 ( P-I&II ) -1983 with upto date amendments. Ammeter I) MAKE II) Type iii ) Range 150/5 Amp 1 Each
126 33 Bus bar chamber of L&T / Hevells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments Three phase indicator lamps complete with toggle switches for Bus Bar Chamber individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Rating 1 Each
127 34 Capacitor of BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 11KVAR 1 Each
128 35 Providing suitable starter of Kilburn/L&T/ Havells/IMP make as per IS : 8544-1979 with'upto date amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release with or without 'initial oil filling as the case may be with single phase prventor as per IS ;1248 ( P-5)1983 with up to date amendments. Starter i) Type ii) Make 1 Each
129 36 Providing and fixing of double flange Cast Iron Sliuce valve of Leader / Kirloskar make for the Column pipe and capable of withstanding the normal seat pressure and as per IS 780-1984(Cast Iron) with latest ammendments PN 1.0 in Column pipe 125 mm dia. 1 Each
130 37 Providing and fixing of double flanged swing type cast iron Reflux valve of Kirloskar/Leader make having Bye pass arrangement on the rising main and capable of 'withstanding normal Seat Pressure as per IS:5312-1984 (P-I) (Cast Iron) with latest ammendmets PN 1.0 in R/main 150 mm dia. 1 Each
131 38 Providing pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. Pressure Gauge i)Make ii)Range. 1 Each
132 39 Supply of PVC 3 core copper cable jointless, flat water proof cable as per BIS 694-1998 latest with upto date amendments, suitable for the pumpsets offered from MCCB to motor including all other electrical equipments/ accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor . The type, size and make shall be subject to approval of HPSEB authorities. Submersible Cable i)Make. ii) Size. 25 mm Sq. 107 Mtr.
133 40 lowering of GMS Column pipe assembly 125 mm dia(MG) including MS flanges of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size 125 mm dia. ii) Class GMS. iii) length. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm) 53.44 Mtr.
134 41 Installation of all above items as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge. 1 Job
135 42 Providing and laying copper PVC insulated 3 core armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster/IEC/ICC/ EICO/National / Grandlay make including all othe accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable. Suppy side From meter of HPSEB to Bus Bar and Switch) i) Size 16 mm Sq. ii) Make finolox /Havells iii) Type armound power cable iv) Capacity v) Core. 3 1 Job
136 43 Providing and fixing double earthing with G.I. wire / plate of 600x600x6.3mm thick electrode complete with material such as thimble, nuts and bolts,charcoal,salt, 25x5mm copper strip as per IS 3043-1987 with upto date amendments for motors and other eletrical equipments and digging of pits etc. complete in all restect as per the dirction of the Engineer-in-Charge. Copper flat 25x3mm 1 Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail