Irrigation And Public Health Department has published Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuthera Jaswala-I And Ii , Badehra Rajputan , Guglehar-I And Ii , Jadla-I And Mawa Sindhian Tehsil Ghanari Distt . Una ( Hp ) Construction Of 12 Nos . T/Well In Village Loharli-Iii , Kuther. Submission Date for this Tender is 04-11-2020. Rising Mains Tenders in Gagret Himachal Pradesh. Bidders can get complete Tender details and download the document.
Name of work :- Construction of 12 Nos T/Well in village Loharli -III, Kuthera Jaswala -I & II, Badehra Rajputan, Guglehar- I & II, Jadla- I and Mawa Sindhian tehsil Ghanari Distt. Una (HP) (SH:- Providing, Laying, Jointing and testing of 200 mm dia GMSERW pipe for R/Main & S/E of Submersible Pumping Machinery for T/Well Badehra Rajputan and Laying, Jointing and testing of 150 mm dia GMS pipe (Medium class) for & S/E of Submersible Pumping Machinery for T/Well Jadla- I) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units. | |
1 | 1 | Excavation in foundation, trenches in earth work in all kinds of soil,such as pick work,jumper work.blasting work in hard rock and soft rock and in saturated soil etc. i/c all leads and lifts , stacking the excavated soil not more than 3 mtrs. clear form the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth, sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as per the direction of the Engineer-in-Charge. | 1689.3 | Cum. | |
2 | 2 | Providing, laying, testing & commissioning at site in trenches bevelled ended BIS marked GMSERW pipe IS/ISO:3183-2007 Grade L210 or A confirming to relevent codes & specification its equivalent latest with up to date ammendments of following dia with steel grade MSERW pipe IS/ISO:3183-2007 Grade L210 or A, having wall thickness & per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.0 to 7.0 mtr. The pipe's ends shall be bevelled suitable for butt welding, The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments & shall be engraved with L210 or A, including all kinds of short pieces, bends etc. made from parent tube including flushing,cleaning and hydraulic testing complete in all respect to the entire satisfaction and direction of the Engineer-in-charge.The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments and jointed with M.S. flanges and butt welding (The cost of earth work in trenches, butt welded joints, MS flanges, welding of M.S. flanges, cost of nuts, bolts and washers of required size and cost of minimum 3 mm thick compressed asbestos fibre/ synthetic rubber gaskets to be measured and paid for separately) with in all leads and lifts and as per entire satisfaction of Engineer - in - charge | |||
3 | 2.1 | (i) 200 mm dia GMSERW pipe Grade L-210 or A , 4.80 mm wall thikness | 1280 | Rmt | |
4 | 3 | Laying , jointing & testing in trenches of galvanised mald steel tube of following dia and grade confirming to IS 1239-2004 ( with latest amendments upto date) as per classification of pipes as specified below. The laying of piupe shall confirm to BIS 5822(with latest amendments upto date ) all kind of special such as bends of all degree to made from parents tube, short pieces,tail pieces all made from parent tube within all leads and lifts. (Earth work in trenches to be measured and paid seperately) | |||
5 | 3.1 | GMS pipe 150 mm dia (medium class) | 1310 | Rmtr. | |
6 | 4 | Providing & welding of MS flanges confirming to table as specified below as per IS- 6392-1971 (latest with upto ammendment ) welding of MS flanges with plain ended GMS/ GMSERW pipe on both end ( The cost of GMS pipe to be measured & paid for seperately)according to relevent BIS standard The welding of flanges with pipes as per IS: 816-1965 with electrode as per IS: 814-1967 including required Nos. and size of M.S nuts and bolts as per IS: 1369-1967 and compressed asbestos fibre jointing geskets sheet not less than 3 mm thick as per IS; 2712-1965. The welding of flanges to be done on both faces in three layers(two inner & one outer) to make the joints leak proof and to the entire satisfaction of the Engineer - in -charge. | |||
7 | 4.1 | MS flange 200 mm dia Table -17 | 5 | Pair | |
8 | 4.2 | MS flange 200 mm dia Table -5 | 6 | Pair | |
9 | 4.3 | MS flange 150 mm dia Table -17 | 11 | Pair | |
10 | 5 | Providing circumferencial butt welded joints by electrical arc welding to following dia & class pipes,welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS- 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes in all leads and lifts to the entire satisfaction of Engineer- in- charge.. | |||
11 | 5.1 | GMSERW pipe 200 mm dia | 202 | Joint | |
12 | 5.2 | GMS pipe (Medium class) 150 mm dia | 207 | Joint | |
13 | 5.3 | Submersible Puping Machinery for T/Well Badehra Rajputtan | |||
14 | 6 | Supply and errection of submersible pumping set of reputed make such as KSB/Calama/BS/Oswal / worthigton/ LUBI/ GROUNDFOS/HINDUSTAN/SEERAX/SABAR/Johnston/Amrut conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments,suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better liffe for shaft conforming to BIS specifications The pump shall be directly coupled to suber-sible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation | 1 | Each | |
15 | 6.01 | Discharge, (Q) 23.02 LPS | |||
16 | 6.02 | Total Head ( H ) 141.95 Mts. | |||
17 | 6.03 | SWL in Tubewell 28.04 mtr. bgl. | |||
18 | 6.04 | R.L. point of discharge 505.10 mtr | |||
19 | 6.05 | R.L. of Pump House = 376.95 mtr | |||
20 | 6.06 | Seasonal fluctuation + draught condition + bowl assembly.9 mtrs. | |||
21 | 6.07 | Drawdown in Tubewell 6.40 mtrs. | |||
22 | 6.08 | R.L of lowest point of pumpset installation=145.51 mtrs | |||
23 | 6.09 | Static suction lift 43.44 mtrs. | |||
24 | 6.1 | Rising main Column pipe | |||
25 | 6.11 | Length 1280.00 mtrs Length 53.15 mtr | |||
26 | 6.12 | Dia 200 mm (4.80 mm thick) Dia 125 mm (M) | |||
27 | 6.13 | Class GMERW pipe Class GMS | |||
28 | 6.14 | iv) Pumping hours 8hours | |||
29 | 6.15 | v) Alititude of installations above M.S.L 422.00mtr | |||
30 | 6.16 | vi) Characteristic of water | |||
31 | 6.17 | a) Temperature 22 Deg Cel. | |||
32 | 6.18 | b)Turbidity __________________JTU | |||
33 | 6.19 | c) Allkanity _________________mg/1Ca Co3 | |||
34 | 6.2 | d) Size of solids _______________ mm | |||
35 | 6.21 | e) others | |||
36 | 6.22 | vii) Depth of T/well 125.00 mtr | |||
37 | 6.23 | viii) Dia of T/well assembly 300/200 mm | |||
38 | 6.24 | ix) Length of assembly pipe 125.00 mtr | |||
39 | 6.25 | x) Dia of housing pipe 300/200 mm | |||
40 | 6.26 | xi) Length of housing pipe 300 mtr | |||
41 | 6.27 | OPERATING CONDITIONS | |||
42 | 6.28 | i) Type of current A.C Three phases. | |||
43 | 6.29 | ii) Frequency 50 Cycles/ Sec. | |||
44 | 6.3 | iii) Rated Voltage 415+/-15% Volts | |||
45 | 6.31 | iv) System of earthing Double Loop earthing as per BIS 3843-1987 latest | |||
46 | 6.32 | v) Speed of Revolution __________________ RPM 2900 | |||
47 | 6.33 | MOTOR | |||
48 | 6.34 | i) Ref to BIS code BIS 9283-1979 with upto date amendments | |||
49 | 6.35 | ii) Type of enclousre of motr As per BIS :4691-1985 (latest) | |||
50 | 6.36 | iii) Mechnical out put in HP | |||
51 | 6.37 | iv) Class of insulation : Class B The motor should be able to withstand intial current of 2.50 times the rated current for two minutes without suffering damages of permanet deformations | |||
52 | 6.38 | PUMP | |||
53 | 6.39 | i) Ref to BIS code BIS 5659-1978 with upto date amendments | |||
54 | 6.4 | ii) Driver Type Electric drivern | |||
55 | 6.41 | iii) Operating Range -15%to +10% of Total head at duty point | |||
56 | 6.42 | iv) Deliver size of Pump ;---------- (to be quoted by tenderer) | |||
57 | 7 | Providing ICTP Main Switch with HRC fuses of Havell/L&Tmake and having capacity 30%extra of the operational rating as per IS : 4064-1978 with upto date amendments. ICTP Switch: i) Make: ii) Type: iii) Capacity: 200 Amp. | 1 | Each | |
58 | 8 | Providing MS Sheet steel fabricated floor mounted switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Switch Board. i) Drawing. ii) layout Plan. | 1 | Each | |
59 | 9 | MCB of L&T/Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB (1) Make (ii) Type iii) Range iv) Capacity. 200 Amp. | 1 | Each | |
60 | 10 | ELCB of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB I) MAKE II) Type iii ) Range iv) Capacity 200 Amp. | 1 | Each | |
61 | 11 | The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Voltage Monitor Relay I) MAKE II) Type iii ) Range 0-500 amp | 1 | Each | |
62 | 12 | A.C. supply,voltmeter of recommended make L&T/Havell/AE/ of suitable range with selector switches as per IS ;1248-1983 with up to date latest amendments. Voltmeter I) MAKE II) Type iii ) Range 0-500 Amp | 1 | Each | |
63 | 13 | AC supply ammeter of L&T /Havell / AE make of suitable range with selector switches and CIS operated as per IS :1248 ( P-I&II ) -1983 with upto date amendments. Ammeter I) MAKE II) Type iii ) Range 200/5 Amp | 1 | Each | |
64 | 14 | Bus bar chamber of L&T / Hevells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments Three phase indicator lamps complete with toggle switches for Bus Bar Chamber individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Rating | 1 | Each | |
65 | 15 | Capacitor of BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 16KVAR | 1 | Each | |
66 | 16 | Providing suitable starter of Kilburn/L&T/ Havells/IMP make as per IS : 8544-1979 with'upto date amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release with or without 'initial oil filling as the case may be with single phase prventor as per IS ;1248 ( P-5)1983 with up to date amendments. Starter i) Type ii) Make | 1 | Each | |
67 | 17 | Providing and fixing of double flange Cast Iron Sliuce valve of Leader / Kirloskar make for the Column pipe and capable of withstanding the normal seat pressure and as per IS 780-1984(Cast Iron) with latest ammendments PN 1.0 in Column pipe 125 mm dia. | 1 | Each | |
68 | 18 | Providing and fixing of double flanged swing type cast iron Reflux valve of Kirloskar/Leader make having Bye pass arrangement on the rising main and capable of 'withstanding normal Seat Pressure as per IS:5312-1984 (P-I) (Cast Iron) with latest ammendmets PN 1.0 in R/main 200 mm dia. | 1 | Each | |
69 | 19 | Providing pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. Pressure Gauge i)Make ii)Range. | 1 | Each | |
70 | 20 | Supply of PVC 3 core copper cable jointless, flat water proof cable as per BIS 694-1998 latest with upto date amendments, suitable for the pumpsets offered from MCCB to motor including all other electrical equipments/ accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor . The type, size and make shall be subject to approval of HPSEB authorities. Submersible Cable i)Make. ii) Size. 50 mm Sq. | 107 | Mtr. | |
71 | 21 | lowering of GMS Column pipe assembly 125 mm dia(MG) including MS flanges of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size 125 mm dia. ii) Class GMS. iii) length. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm) | 53.44 | Mtr. | |
72 | 22 | Installation of all above items as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge. | 1 | Job | |
73 | 23 | Providing and laying copper PVC insulated 3 core armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster/IEC/ICC/ EICO/National / Grandlay make including all othe accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable. Suppy side From meter of HPSEB to Bus Bar and Switch) i) Size 25 mm Sq. ii) Make finolox /Havells iii) Type armound power cable iv) Capacity v) Core. 3 | 1 | Job | |
74 | 24 | Providing and fixing double earthing with G.I. wire / plate of 600x600x6.3mm thick electrode complete with material such as thimble, nuts and bolts,charcoal,salt, 25x5mm copper strip as per IS 3043-1987 with upto date amendments for motors and other eletrical equipments and digging of pits etc. complete in all restect as per the dirction of the Engineer-in-Charge. Copper flat 25x3mm | 1 | Job | |
75 | 24.1 | Submersible Puping Machinery for T/Well at Jadla-1 | |||
76 | 25 | Supply and errection of submersible pumping set of reputed make such as KSB/Calama/BS/Oswal / worthigton/ LUBI/ GROUNDFOS/HINDUSTAN/SEERAX/SABAR/Johnston/Amrut conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments,suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better liffe for shaft conforming to BIS specifications The pump shall be directly coupled to suber-sible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation | 1 | Set | |
77 | 25.01 | Discharge, (Q) 16.67 LPS | |||
78 | 25.02 | Total Head ( H ) 109.59 Mts. | |||
79 | 25.03 | SWL in Tubewell 12.20 mtr. bgl. | |||
80 | 25.04 | R.L. point of discharge 465.20 mtr | |||
81 | 25.05 | R.L. of Pump House = 420.00 mtr | |||
82 | 25.06 | Seasonal fluctuation + draught condition + bowl assembly.9 mtrs. | |||
83 | 25.07 | Drawdown in Tubewell 21.95 mtrs. | |||
84 | 25.08 | R.L of lowest point of pumpset installation=145.51 mtrs | |||
85 | 25.09 | Static suction lift 43.15 mtrs. | |||
86 | 25.1 | Rising main Column pipe | |||
87 | 25.11 | Length 1310.00 mtrs Length 53.15 mtr | |||
88 | 25.12 | Dia 150 mm (4.80 mm thick) Dia 125 mm (M) | |||
89 | 25.13 | Class GMS pipe Class GMS | |||
90 | 25.14 | iv) Pumping hours 8hours | |||
91 | 25.15 | v) Alititude of installations above M.S.L 422.00mtr | |||
92 | 25.16 | vi) Characteristic of water | |||
93 | 25.17 | a) Temperature 22 Deg Cel. | |||
94 | 25.18 | b)Turbidity __________________JTU | |||
95 | 25.19 | c) Allkanity _________________mg/1Ca Co3 | |||
96 | 25.2 | d) Size of solids _______________ mm | |||
97 | 25.21 | e) others | |||
98 | 25.22 | vii) Depth of T/well 125.00 mtr | |||
99 | 25.23 | viii) Dia of T/well assembly 300/200 mm | |||
100 | 25.24 | ix) Length of assembly pipe 125.00 mtr | |||
101 | 25.25 | x) Dia of housing pipe 300/200 mm | |||
102 | 25.26 | xi) Length of housing pipe 300 mtr | |||
103 | 25.27 | OPERATING CONDITIONS | |||
104 | 25.28 | i) Type of current A.C Three phases. | |||
105 | 25.29 | ii) Frequency 50 Cycles/ Sec. | |||
106 | 25.3 | iii) Rated Voltage 415+/-15% Volts | |||
107 | 25.31 | iv) System of earthing Double Loop earthing as per BIS 3843-1987 latest | |||
108 | 25.32 | v) Speed of Revolution __________________ RPM 2900 | |||
109 | 25.33 | MOTOR | |||
110 | 25.34 | i) Ref to BIS code BIS 9283-1979 with upto date amendments | |||
111 | 25.35 | ii) Type of enclousre of motr As per BIS :4691-1985 (latest) | |||
112 | 25.36 | iii) Mechnical out put in HP | |||
113 | 25.37 | iv) Class of insulation : Class B The motor should be able to withstand intial current of 2.50 times the rated current for two minutes without suffering damages of permanet deformations | |||
114 | 25.38 | PUMP | |||
115 | 25.39 | i) Ref to BIS code BIS 5659-1978 with upto date amendments | |||
116 | 25.4 | ii) Driver Type Electric drivern | |||
117 | 25.41 | iii) Operating Range -15%to +10% of Total head at duty point | |||
118 | 25.42 | iv) Deliver size of Pump ;---------- (to be quoted by tenderer) | |||
119 | 26 | Providing ICTP Main Switch with HRC fuses of Havell/L&Tmake and having capacity 30%extra of the operational rating as per IS : 4064-1978 with upto date amendments. ICTP Switch: i) Make: ii) Type: iii) Capacity: 125 Amp. | 1 | Each | |
120 | 27 | Providing MS Sheet steel fabricated floor mounted switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Switch Board. i) Drawing. ii) layout Plan. | 1 | Each | |
121 | 28 | MCCB of L&T/Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB (1) Make (ii) Type iii) Range iv) Capacity. 100 Amp. | 1 | Each | |
122 | 29 | ELCB of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB I) MAKE II) Type iii ) Range iv) Capacity 125 Amp. | 1 | Each | |
123 | 30 | The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Voltage Monitor Relay I) MAKE II) Type iii ) Range 0-500 amp | 1 | Each | |
124 | 31 | A.C. supply,voltmeter of recommended make L&T/Havell/AE/ of suitable range with selector switches as per IS ;1248-1983 with up to date latest amendments. Voltmeter I) MAKE II) Type iii ) Range 0-500 Amp | 1 | Each | |
125 | 32 | AC supply ammeter of L&T /Havell / AE make of suitable range with selector switches and CIS operated as per IS :1248 ( P-I&II ) -1983 with upto date amendments. Ammeter I) MAKE II) Type iii ) Range 150/5 Amp | 1 | Each | |
126 | 33 | Bus bar chamber of L&T / Hevells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments Three phase indicator lamps complete with toggle switches for Bus Bar Chamber individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Rating | 1 | Each | |
127 | 34 | Capacitor of BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 11KVAR | 1 | Each | |
128 | 35 | Providing suitable starter of Kilburn/L&T/ Havells/IMP make as per IS : 8544-1979 with'upto date amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release with or without 'initial oil filling as the case may be with single phase prventor as per IS ;1248 ( P-5)1983 with up to date amendments. Starter i) Type ii) Make | 1 | Each | |
129 | 36 | Providing and fixing of double flange Cast Iron Sliuce valve of Leader / Kirloskar make for the Column pipe and capable of withstanding the normal seat pressure and as per IS 780-1984(Cast Iron) with latest ammendments PN 1.0 in Column pipe 125 mm dia. | 1 | Each | |
130 | 37 | Providing and fixing of double flanged swing type cast iron Reflux valve of Kirloskar/Leader make having Bye pass arrangement on the rising main and capable of 'withstanding normal Seat Pressure as per IS:5312-1984 (P-I) (Cast Iron) with latest ammendmets PN 1.0 in R/main 150 mm dia. | 1 | Each | |
131 | 38 | Providing pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. Pressure Gauge i)Make ii)Range. | 1 | Each | |
132 | 39 | Supply of PVC 3 core copper cable jointless, flat water proof cable as per BIS 694-1998 latest with upto date amendments, suitable for the pumpsets offered from MCCB to motor including all other electrical equipments/ accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor . The type, size and make shall be subject to approval of HPSEB authorities. Submersible Cable i)Make. ii) Size. 25 mm Sq. | 107 | Mtr. | |
133 | 40 | lowering of GMS Column pipe assembly 125 mm dia(MG) including MS flanges of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size 125 mm dia. ii) Class GMS. iii) length. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm) | 53.44 | Mtr. | |
134 | 41 | Installation of all above items as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge. | 1 | Job | |
135 | 42 | Providing and laying copper PVC insulated 3 core armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster/IEC/ICC/ EICO/National / Grandlay make including all othe accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable. Suppy side From meter of HPSEB to Bus Bar and Switch) i) Size 16 mm Sq. ii) Make finolox /Havells iii) Type armound power cable iv) Capacity v) Core. 3 | 1 | Job | |
136 | 43 | Providing and fixing double earthing with G.I. wire / plate of 600x600x6.3mm thick electrode complete with material such as thimble, nuts and bolts,charcoal,salt, 25x5mm copper strip as per IS 3043-1987 with upto date amendments for motors and other eletrical equipments and digging of pits etc. complete in all restect as per the dirction of the Engineer-in-Charge. Copper flat 25x3mm | 1 | Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail