Provision Of Medical Gas Pipeline For Military Hospital At Nda Khadakwasla ., GE (P) NDA Khadakwasla-Maharashtra

Military Engineer Services-MES has published Provision Of Medical Gas Pipeline For Military Hospital At Nda Khadakwasla .. Submission Date for this Tender is 09-11-2020. Medical Gas System Tenders in GE (P) NDA Khadakwasla Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

25796280
Provision Of Medical Gas Pipeline For Military Hospital At Nda Khadakwasla .
Open Tender
Indian
Maharashtra
GE (P) NDA Khadakwasla
09-11-2020

Tender Details

81556Provision Of Medical Gas Pipeline For Military Hospital At Nda Khadakwasla .

Key Value

Document Fees
INR 1000 /-
EMD
INR 155000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : PROVISION OF MEDICAL GAS PIPELINE FOR MILITARY HOSPITAL AT NDA KHADAKWASLA.
Sl. No. Item Description Item Code / Make Quantity Unit
1 1 SCH 'A' PART- I CONSTRUCTION OF SHED CARPET AREA SIZE 16.0 MTR X 4.0 MTR COMPRISING OF FOLLOWING ITEMS OF WORK :-
2 1.01 Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out hard dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as directed. 10 Each
3 1.02 M&L for Plain Cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete as specified and as directed. 2.88 Cum
4 1.03 M&L for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. Fe 410-W (Gde E-250) quality A complete as specified and as directed. 417.6 Kg
5 1.04 M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, Fe 410-W (Gde E-250) quality A complete as specified and as directed. 1053 Kg
6 1.05 M&L for Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete as specified and as directed. 149.6 Kg
7 1.06 M&L for Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe 410-W (Gde E-250) quality A complete as specified and as directed. 537.75 Kg
8 1.07 Preparation of new or previously untreated steel surface of any description over 10 cm in width or girth, not otherwise described, applying two coats of synthetic enamel paint over a coat zinc primer complete as specified and as directed. 50 Sqm
9 1.08 Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete as specified and as directed. 180.5 Sqm
10 1.09 S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete as specified and as directed. 9.96 Sqm
11 1.1 Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out hard dense soil complete as directed. 14.33 Cum
12 1.11 M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete as specified and as directed. 3.58 Cum
13 1.12 M&L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6 m mean radius, built in CM (1:6) complete as specified and as directed.\n 14.56 Cum
14 1.13 M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 internal surfaces, finished even and smooth (without using extra cement) complete as specified and as directed. 23.88 Sqm
15 1.14 M&L for preparation of new plastered surfaces applying two coats of distemper oil emulsion over a coat of approved primmer on internal wall surface including internal wall care putty /white cement putty over entire wall surfaces complete as specified and as directed. 23.88 Sqm
16 1.15 M&L for for Rendering 10mm thick CM (1:6) and 5mm thick on CM (1:3) including water proofing compound, on fair faces of brick work or concrete surfaces external surfaces, finished even and fair complete as specified and as directed. 24.48 Sqm
17 1.16 Supply only integral water proofing compound ISI marked complete all as specified and as directed. 1.41 kg
18 1.17 M&L for preparation of new plastered surfaces applying two coats of cement base paint on wall surface complete all as specified and as directed. 24.48 Sqm
19 1.18 M&L for Machine cuddappa stone slab 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. 12 Sqm
20 1.19 M&L for Granite 18mm to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. 12 Sqm
21 1.2 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as directed. 20 Rm
22 1.21 Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in hard dense soil complete all as specified and as directed. 71.2 Sqm
23 1.22 M&L for 150 mm thick Hardcore of broken stone gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed. 7.12 Cum
24 1.23 M&L for 75 mm thick Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as sub base complete all as specified and as directed. 71.2 Sqm
25 1.24 M&L for 100mm thick plain cement concrete M-20 grade (Design mix) as in flooring and mass concrete (20mm graded stone aggregate) etc complete all as specified and as directed. 64 Sqm
26 1.25 M&L for Forming 75 mm deep x 10mm wide Contraction (Dummy) joints filled with sealing compound grade 'A' all as specified and as directed. 4.8 Ten Rm
27 1.26 M&L for 15 mm thick wearproof topping as specified (incorporating an approved metallic floor hardener), laid on concrete floors and pavings, and finished even and smooth including metallic hardener etc complete all as directed. 64 Sqm
28 1.27 M&L for Chequred cement concrete tiles with grey cement and pigments 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 15mm thick screed bed of cm 1:6 complete all as specified and as directed. 7.2 Sqm
29 1.28 M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as directed. 12.13 Cum
30 1.29 Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point (Soil) complete all as directed. 14.38 Cum
31 2 SCH 'A' PART- II INTERNAL ELECTRIFICATION / MISC ITEMS.
32 2.01 Supply laying in trenches or fixing on wall with shaddle and testing cable XLPE insulated screened, PVC bedded galvanized steel strip aromoured electric power cables (heavy duty) 1100, Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and as directed. 50 RM
33 2.02 S&F Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 25 KVA with built in overload/short circuit protection High/Low voltage cut off and bypass arrengment as directed. 1 Each
34 2.03 S & F Distribution Board 8 way TPN vertical type, double,door,suitable for housing MCCB incomer and MCB SP/TP as out going having IP 54 protection, 200 Amps rated busbar including blank plate complete all as specified and as directed. 1 Each
35 2.04 Supply &, fixing and connecting MCCB, 4 Pole, 415 Volt, 63 Amps having breaking capacity 25 KA, with adjustable thermal release range 50 to 63 Amp complete all as specified and as directed. 1 Each
36 2.05 Supply & fixing and connecting MCB, TP, 415 Volt, 32 Amps 'C' series 16 KA complete all as specified and as directed. 5 Each
37 2.06 Supply & fixing and connecting MCB, SP, 415 Volt, 16 Amps 'C' series 10 KA complete all as specified and as directed. 4 Each
38 2.07 M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) connected to galvanized iron strip 25 x 4 mm, 7.5 mtr long by means of bolts, nuts and washers of galvanized iron or steel, GI light grade protection pipe 15 mm dia, GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No 3 of SSR-2009 pt-I and testing complete including earth work excavating in any type of earth strata PCC 1:2:4 as in earthing pit, 50 mm PCC pit cover with 6mm iron handle attached , common salt charcoal all as specified including testing on complete. Note GI strip beyond 7.5 mtr shall be measured and paid for seprately. 7 Each
39 2.08 Excavation in trenches not exceeding 1.5 m in width and not exceeding 1.5 m in depth and getting out in any type of soil for laying of cables (read inconjuntion with clause 3.2 of SSR Part-II) , foundation of poles, stay etc complete all as directed. 2 Cum
40 2.09 M&L for laying of half round reinforced concrete pipe, of dia 150 mm, half round for bottom and half round for top. before laying excavated area shall be leveled. complete all specified and directed. Note : 01 Half round top and 01 half round bottom together will be considered as one running meter complete all as secified and directed as per sample approved by GE. 20 RM
41 2.1 M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required with 25 x 4 mm GI strip complete all as specified and as directed. 30 RM
42 2.11 M & L for making holes by core cutting machine on stone /concrete / brick walls.Dia of hole not exc.20 mm to 40 mm and thickness of wall 50 cm to 70 cm for entry of suction and discharge pipes and making good distarbed surfaces with cement mortar (1:4) and finally finished with plaster of parise and painted the distrubed surfaces to match with existing type of paint and tint complete all as directed. 110 Each Job
43 2.12 M & L Point wiring with FRLSH grade 1.5 Sq mm multi stranded insulated copper conductor single core PVC insulated cable 1100 volt including ISI marked PVC casing and caping including PVC rectangular board open recessed cover with 3 mm thick plastic laminated sheet cover incl PVC insulated 1.5 Sqmm copper conductor as earth wire for one light controlled by one switch complete all as specified and as directed. 8 Each Point
44 2.13 All as per item No 2.12 here- in- above but for 3-pin socket out let 5 Amps on independent board with continous PVC insulated copper conductor cable 1.5 Sqmm earth wire complete all as specified and as directed. 42 Each Point
45 2.14 All as per item No 2.12 here- in- above but for 3-pin socket out let 15 Amps on independent board with 2.5 Sqmm Multi std.copper conductor PVC insulated cable 1100 volts grade with continous 2.5 Sqmm earth wire complete all as specified and as directed. 21 Each Point
46 2.15 S&F Switch socket combination 2-in-1 5 pin 5 Amps flush type (ISI Marked) complete all as specified and as directed by Engr-in-charge. 42 Each
47 2.16 S&F Switch piano flush type 6 Amps single pole one way complete all as specified and as directed. 8 Each
48 2.17 S&F Switch socket combination 5 in 1, 5 and 15 Amp flush type universal controlled by one switch (ISI Marked) complete all as specified and as directed. 21 Each
49 2.18 M&L for circuit sub main wiring 3 x 2.5 (phase , neutral and earth) PVC insulated (heavy duty) 1100 volts grade, FRLS, with stranded copper conductor in & including PVC casing caping/conduit of suitable size not less than 25 mm (3 run of 2.5 sqmm cable and one run of PVC casing caping/conduit will be measured as one unit) complete all as specified and as directed. (from distribution board to metal clad switch socket point) 120 RM
50 2.19 S&F Fluorescent tube light fittings,1 x 36 W, 240 V Energy efficient T8, Powder coated Regal Batten type luminaire with electronic ballast, suitable for domestic application 240 V,50 Hz supply.,complete with lamp 36 W, and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge. 8 Each
51 3 SCH 'A' PART- III PLANT ROOM EQUIPMENT : Supply, Installation, Testing and commissioning MEDICAL AIR SYSTEM including following items :-
52 3.01 S&F Oil Free Air Compressor 2 stage Double Cylinder with Composite Resin Pistons, delivering maximum of 22.93 CFM @ 8.5 Kg/cm2 pressure, including 5hp/415V motor.100% Oil free complete all as specified and as directed. \n 2 Set
53 3.02 S&F Air Dryer 45 cfm at 7 kg/cm2 working pressure with pre filter and by pass arrangement.Maximum Operating Pressure : 16 kg/cm2(g) complete all as specified and as directed. \nAir Inlet Temperature : 380C Max\nOperating Pressure : 7 kg/cm2(g)\nPre-Filter Rating : 0.01 Micron\nCycle Time : 4 Minutes\nOperating Voltage : 100-240 V AC 50/60 Hz 1 Ph\nOutlet Conditions : Dry air at -400C PDP*\nPurge Loss : 15±1% including following makes.\n* ISO:8573-1:2010 (E) class -2. \n 2 Set
54 3.03 S&F 3 Stage Breathing Filter oil filter, dust filter, activated carbon filter Each filter should be fitted with differential pressure gauges to monitor filter performance complete all as specified and as directed. 1 Set
55 3.04 Plant Room Components - Arranged Locally:\ni) S & F Duplex pressure regulating system should have Pressure regulator, Isolation valve, Pressure indicator for Medical Air regulation with an by pass arrangement. Which includes 4 Nos of isolation valve, 2 nos of regulators, 2 nos of pressure indicator. \nii) Receiver Tank - 1000 lits - 1nos.\nPressure Gauge, Pressure Sensors, Safety Valves, Auto Drain Valves to be fitted on receiver tanks complete all as specified and as directed. 1 Set
56 3.05 S&F PLC Control Panel for Medical Air Compressors & Vacuum Pump with timed functioning / cascading of compressors with display of status & alarm signals. (Basic System) complete all as specified and as directed. 1 Set
57 3.06 Supply, Installation, Testing and commissioning MEDICAL VACCUM SYSTEM including following items:
58 3.07 Vacuum Pump Model 5 HP Motor complete with electrical fittings and mounting arrangement complete all as specified and as directed. 2 Set
59 3.08 Medical Vacuum System Components - \n S & F medical vacuum system Comprising of: Bacteria Filters - 2nos, interconnecting pipes, NRV, Exhaust silencer, Pressure Gauge & Pressure Sensors, isolation valves & piping complete.Receiver tank – 1000 liters x 01 complete all as specified and as directed. 1 Set
60 3.09 Supply, Installation, Testing and commissioning OXYGEN MANIFOLD SYSTEM Main Building including following items:
61 3.1 S&F Oxygen Manifold 5+5 along with centre frame NRV,Tail pipes etc marked, Conforms to BS EN ISO 7396 - 1 :2007, NFPA 99 : 2005, Type 1, HTM 01-02 complete all as specified and as directed. 1 Set
62 3.11 S&F Semi Automatic Control Panel for the Oxygen. 1500 LPM capacity Complies and meets with HTM02- 01/NFPA99/ISO 7396-1 complete all as specified and as directed. 1 Set
63 3.12 Supply, Installation, Testing and commissioning OXYGEN MANIFOLD SYSTEM MI ROOM including following items:
64 3.13 S&F Oxygen Manifold 1+1 along with centre frame NRV,Tail pipes etc marked, Conforms to BS EN ISO 7396 - 1 :2007, NFPA 99 : 2005, Type 1, HTM 01-02 complete all as specified and as directed. 1 Set
65 3.14 S&F Oxygen Regulator Single Stage Twin Guage complete all as specified and as directed. 1 Each
66 3.15 Supply, Installation, Testing and commissioning NITROUS-OXIDE MANIFOLD SYSTEM including following items:
67 3.16 S&F Nitrous-oxide Manifold 2+2 along with centre frame NRV,Tail pipes etc marked, Conforms to BS EN ISO 7396 - 1 :2007, NFPA 99 : 2005, Type 1, HTM 01-02 complete all as specified and as directed. 1 Set
68 3.17 S&F Nitrous-oxide Emergency 1 Cylinder complete all as specified and as directed. 1 Each
69 3.18 S&F Nitrous-oxide Regulator Single Stage Twin Guage complete all as specified and as directed. 2 Each
70 3.19 S&F Pipeline & all required necessary Accessories BS / DIN Type Gas Outlets For Wall / BHP / Pendants - Front Loading for following items:
71 3.2 S&F Oxygen Gas Outlet complete all as specified and as directed. 32 Set
72 3.21 S&F Nitrous-oxide Gas Outlet complete all as specified and as directed. 6 Set
73 3.22 S&F Medical Air Gas Outlet - 4 Bar complete all as specified and as directed. 18 Set
74 3.23 S&F Vacuum Gas Outlet complete all as specified and as directed. 16 Set
75 3.24 S&F Distribution Copper Pipe manufactured as per BS EN 13348:2001 standard alongwith third party inspection certificate from Lloyds' complete all as specified and as directed for following size of items :
76 3.25 S&F 12 mm OD x 0.7 mm thick 153 Rm
77 3.26 S&F 15 mm OD x 0.9 mm thick 439 Rm
78 3.27 S&F 22 mm OD x 0.9 mm thick 322 Rm
79 3.28 S&F 28 mm OD x 0.9 mm thick 150 Rm
80 3.29 S&F Isoaltion Ball Valves with Brass adapters for area / regional isolation complete all as specified and as directed for following bore size :
81 3.3 S&F 15 mm 22 Each
82 3.31 S&F 22 mm 7 Each
83 3.32 S&F 28 mm 4 Each
84 3.33 Digital Gas Alarms For OT & ICU
85 3.34 S&F 3 Gas with digital display complete all as specified and as directed. 1 Set
86 3.35 S&F 4 Gas with digital display complete all as specified and as directed. 1 Set
87 3.36 Gas Accessories
88 3.37 S&F BPS Flow Meter With Humidifier bottle For Oxygen complete all as specified and as directed. 22 Each
89 3.38 S&F Ward Suction Unit 600 ml Jar with regulator for Vaccum complete all as specified and as directed. 16 Each
90 3.39 S&F Hose connection Probes For Oxygen, Nitrous,Air-4 & Vacum For BPC, Ward vacum Unit, Ventilators & Anesthesia W/s complete all as specified and as directed. 72 Each
91 3.4 S&F Low Pressure Tubing for Ward / ICU suction units complete all as specified and as directed. 60 Mtr
92 3.41 S&F Hanging Support- Threaded rod, Fastner, C-channel patti & Saddle / Mansoon Ring with fastners & threaded Rods complete all as specified and as directed. 1000 Each
93 3.42 Bed Head Panels - S & F Metal Enclosures with Powder coating for following items complete all as specified and as directed.
94 3.43 Type A For ICU beds - Provision for - 4 Gas Points, 4 electrical sockets, 1 nurse call socket, 1 RJ45 socke complete all as specified and as directed. 8 Set
95 3.44 Type B For Wards & Post & Pre operative beds - Provision for - 3 Gas Points, 4 electrical sockets, 1 nurse call socket, 1 RJ45 socket complete all as specified and as directed. 13 Set
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail