Military Engineer Services-MES has published Maintenance/ Repairs To Firefighting Equipments And Fire Alarm System Installed At Various Locations , Hanger Doors And Rolling Shutter Motor And Compressors In Mk-54 And Street Lights , Flood Lights And Etc At Arakkonam. Submission Date for this Tender is 11-11-2020. Fire Alarm Systems Tenders in GE M NAS ARAKKONAM Tamil Nadu. Bidders can get complete Tender details and download the document.
Name of Work: MAINTENANCE/ REPAIRS TO FIREFIGHTING EQUIPMENTS AND FIRE ALARM SYSTEM INSTALLED AT VARIOUS LOCATIONS, HANGER DOORS AND ROLLING SHUTTER MOTOR AND COMPRESSORS IN MK-54 AND STREET LIGHTS, FLOOD LIGHTS AND CONVERSION OF CONVENTIONAL LIGHTS INTO LED AT ZONE ‘A’ TO ‘C’ AT ARAKKONAM (TENDER ID NO. 2020_MES_365281_1) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling all the modules of fire alarm control panel and carry out checking of all parts such as main control panel, intelligent, repeater control panel, intelligent addressable smoke detectors, addressable input/ out modules, panel moudles, indicating circuits, control circuits, manual call point, hooters, and notification appliance circuits local and remote operated terminals, etc., including testing, reassembling, trial programming with a sample of devices, replacing fault modules where necessary and retesting all the functionals such as power test, CPU fault, GND fault, disable, reset, alarm silence, panel silence, drill, alarm, SUP, trouble monitor and command menues, fire, fault, etc., and confirm serviceability of the FACP and labour charges for loop testing (address and setting programming and testing all devices in intra panel loop) to identify the defects in devices, loop errors and final testing and commissioning complete for fire alarm systems located at following locations complete all as specified and as directed by Engr-in-charge.\nNotes for item No. 1.01 to 1.07:\n(i) Spares required for replacement shall be measured and paid separately under relevant items as supply only and labour cost for fixing is deemed to be included in the rate quoted.\n(ii) Rates deemed to be inclusive of spares other than above required to make the system serviceable visiting charges and tools and plants like ladder, boom lift etc., all as directed by Engr-in-charge of GE (M) NAS Arakkonam.\n(iii) If any break down occurs /fire alarm system the contractor has to repair/ rectify the fault within 24 HRS after receiving of complaints, vide any mode incase if the contractor failed to attend the fault, penalty will be charged @ 1000 per day/ per installation after 24 HRS.\n(iv) Maintaining of service register is essential for every servicing with the signature of concern incharge.\n(v) Item will be measured and paid only for the month of servicing carried out and the system is in serviceable condition. | |||
2 | 1.01 | New Magazine | 6 | Per month | |
3 | 1.02 | Processing unit building | 6 | Per month | |
4 | 1.03 | MK-54 building including service block | 6 | Per month | |
5 | 1.04 | P8I Maint hangar - 1 No.\nMake: HONEYWELL (upto 28 meter height) | 6 | Per month | |
6 | 1.05 | BSF (LRMR) and storage Accn - 1 No.\nMake: APPOLO | 6 | Per month | |
7 | 1.06 | Four hangar - 4 Nos.\nMake: APPOLO (upto 28 meter height) | 6 | Per month | |
8 | 1.07 | Magazine - 01 No (Magazine 'A' to Magazine 'D') | 6 | Per month | |
9 | 2 | Supply only the following items complete all as specified and as directed by Engr-in-charge. | |||
10 | 2.01 | Detectors complying with and type certified to EN-45 addressable type smoke detector photoelectric/ optical with base with self built intelligence as per IS: 11360.\nMake: Honeywell /Appolo | 6 | Each | |
11 | 2.02 | Addressable type flame detectors with UV /IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module).\nMake: Honeywell /Appolo | 4 | Each | |
12 | 2.03 | Liquid foam in container | 95 | Litres | |
13 | 2.04 | Addressable type multi sensor with heat and smoke combination.\nMake: Honeywell/ Appolo | 6 | Each | |
14 | 2.05 | Hooter/ addressable sounder\nMake: Honeywell /Appolo | 2 | Each | |
15 | 2.06 | Manual call point\nMake: Honeywell/ Appolo | 12 | Each | |
16 | 2.07 | Zone module\nMake: Morley/ Vairatech | 4 | Each | |
17 | 2.08 | Battery 7 AH\nMake: Exide | 5 | Each | |
18 | 2.09 | Short circuit isolator\nMake: Honeywell/ Appolo | 3 | Each | |
19 | 2.1 | Fire alarm control panel\nMake: Appolo/ Siemens | 5 | Each | |
20 | 3 | Taking down the monoblock pump set with 7.5 HP capacity motor (Make : Kirloskar) from terrace of six storied building, lowering to ground floor, transporting to private workshop, dismantling and opening the pump, metalling the worn out shaft and replacement of NDE/ DE bearings, gland flange, gunmetal bush and lubricating the bearings and replacing the gland rope of existing size reassembling, refixing in position commissioning and testing complete all as specified and as directed by Engr-in-charge. | 3 | Each Job | |
21 | 4 | Taking down the 3 phase, 415V, 50Hz, 7.5 HP capacity monoblock pump set (Make: Kirloskar) from terrace of six storied building, lowering to ground floor, transporting to private workshop, dismantling and opening, removing burntout winding wire carefully cleaning the slots and rewinding of motor with super enamelled copper winding of existing gauge, insulating, varnishing, backing including servicing the pump by greasing and lubricating, reassembling, re-fixing in position commissioning and testing complete all as specified and as directed by Engr-in-charge. | 3 | Each Job | |
22 | 5 | Taking down siren motor 3 phase 50 Hz, (Make: KHIVIRAJ) from terrace of buildings, lowering to ground floor, transporting to private work shop, dismantling, opening, varnishing the winding wire carefully cleaning the slots backing including replacement of wornout bearings, lubricating, reassembling, refixing in position commissioning and testing complete all as specified and as directed by Engr-in-charge. | |||
23 | 5.01 | Siren 2 miles range at akash ganga 6 storied building. | 2 | Each Job | |
24 | 5.02 | Siren 5 miles range. | 2 | Each Job | |
25 | 6 | Taking down siren motor 3 phase 50 Hz from terrace of the buildings, lowering to ground floor, transporting to private work shop, dismantling, opening, removing burnt out winding wire carefully cleaning the slots and rewinding of siren motor with enamelled copper winding of existing gauge, insulating, varnishing, backing including replacement of wornout bearings, lubricating, reassembling, refixing in position commissioning and testing complete all as specified and as directed by Engr-in-charge. | |||
26 | 6.01 | Siren 2 miles range at akash ganga 6 storied building | 3 | Each Job | |
27 | 6.02 | Siren 5 miles range | 2 | Each Job | |
28 | 7 | Taking down the existing unserviceable rusted MS pipe from floor, in trenches and ground floor to terrace by dismantling from wall/ terrace cutting by gas or arc welding for the following sizes complete all as specified and as directed by Engr-in-charge. | |||
29 | 7.01 | 200mm dia bore pipe | 3 | RM | |
30 | 7.02 | 150mm dia bore pipe | 3 | RM | |
31 | 7.03 | 100mm dia bore pipe | 18 | RM | |
32 | 8 | Supply and fix mild steel pipe heavy grade including all fittings from terrace /wall fixed with mild steel clamps, brackets of required, necessary bends, reducers, flange and welding the pipe connection all in position including painting with two coats of synthetic enamel paint of approved tint over a coat of red oxide making good the disturbed portion for the following sizes complete all as specified and as directed by Engr-in-charge.\nNote: PCC will be measured and paid separately under relevent items. | |||
33 | 8.01 | 200mm dia bore pipe | 3 | RM | |
34 | 8.02 | 150mm dia bore pipe | 3 | RM | |
35 | 8.03 | 100mm dia bore pipe | 18 | RM | |
36 | 9 | Taking down existing rusted/ corrded pump set from foundation by disconnecting electrically/ mechanically and kept at site and removing the corroded/ damaged mild steel foundation frame and replace with new MS frame as per existing gauge and size for 7.5 HP capacity motor including replacement of bolts, nuts with washers and applying two coats of synthetic enamel paint over a coat of red oxide primer of exisitng colour shades complete all as specified and as directed by Engr-in-charge. | 2 | Each Job | |
37 | 10 | Taking down existing siren from corroded/ broken MS foundation by disconnecting electrically/ mechanically and kept at site and removing the corroded/ damaged mild steel foundation and replace with new MS frame as per existing gauge and size for siren motor including replacement of bolts, nuts with washers and applying two coats of synthetic enamel paint over a coat of red oxide primer of exisitng colour shades complete all as specified and as directed by Engr-in-charge. | 2 | Each Job | |
38 | 11 | Taking down the existing unserviceable CI non return valve supply and fix new CI non return valves with out bypass arrangement flange type PN 1.6 complete with rubber gasket, bolts and nuts, etc., complete all as specified and as directed by Engr-in-charge. | |||
39 | 11.01 | 150mm dia | 1 | Each | |
40 | 11.02 | 100mm dia | 3 | Each | |
41 | 11.03 | 80mm dia | 1 | Each | |
42 | 11.04 | 50mm dia | 1 | Each | |
43 | 12 | Taking down the existing unserviceable CI sluice valve, supply and fix new sluice valve with iron wheel stainless steel spindle and wedge nuts with flanged of size 100mm dia, PN1.6 long body conforming to IS 14846-2000 including replacing bolts, nuts and washers with gaskets jointing etc., complete all as specified and as directed by Engr-in-charge. | 4 | Each | |
44 | 13 | Taking down the existing damaged/ rusted siren motor cover, supply and fix new siren motor cover made with MS sheet 3mm thick with handle arrangement including MS flat all as per existing type/ size for supporting to siren motor cover and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide primer of exisitng colour shades complete all as specified and as directed by Engr-in-charge. | 2 | Each Job | |
45 | 14 | Taking down the existing damaged/ rusted centrifugal pump set cover, supply and fix new centrifugal pump set cover made with MS sheet 3mm thick with handle arrangement including MS flat all as per existing type /size for supporting to centrifugal motor cover and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide primer of exisitng colour shades complete all as specified and as directed by Engr-in-charge. | 1 | Each Job | |
46 | 15 | Material and labour for painting with two coats of synthetic enamel paint of approved tint as directed on iron/ steel surfaces of any description over 10cm in width or girth including holder bats, distance pieces, etc., including cleaning the surface for free from dust and deposits complete all as specified and as directed by Engr-in-charge. | 60 | Sqm | |
47 | 16 | Material and labour for painting with two coats of synthetic enamel paint of approved tint as directed on pipes any description (fire hydrants, pipe lines) not exc 60cms girth including holder bats, distance pieces, etc., including cleaning the surface of pipes and fire fighting pump house headders, air releasing vessels and suction and delivery pipes (length measured over bends, branches etc.,) complete all as specified and as directed by Engr-in-charge. | 55 | RM | |
48 | 17 | Supply and lay XLPE insulated armoured heavy duty electric cables with aluminium conductor 1100 volts grade, cross sectional area 6 sqmm 4 core ccomplete all as specified and as directed by Engr-in-charge. | 25 | RM | |
49 | 18 | Taking down the existing damaged hose 63mm dia, supply and fix long hose for fire fighting 63mm dia 15m length conforming to IS636 complete with male and female coupling complete all as specified and as directed by Engr-in-charge. | 9 | Each | |
50 | 19 | Taking down the existing unserviceable gun metal female coupling flange 63mm dia and supply and fix new stainless steel female coupling of 63mm dia with flange 63mm dia including replacing bolts, nuts and washers with gaskets jointing etc., complete all as specified and as directed by Engr-in-charge. | 15 | Each Set | |
51 | 20 | Taking down the existing hydrant valve and supply and fix new stainless steel fire hydrant valve of size 63mm dia including replacing bolts, nuts and washers with gaskets jointing etc., and making necessary welding for anti thievery measures/ arrangements complete all as specified and as directed by Engr-in-charge. | 24 | Each Job | |
52 | 21 | Taking down the existing unserviceable air release valve 25mm dia and fixing new PVC air release valve in position with GI nipple in terrace of multi-storied building and testing complete all as specified and as directed by Engr-in-charge. | 2 | Each Job | |
53 | 22 | Opening the top of the sluice valve carefully taking out the gate and spindle, scrapping/ cleaning gate body of sluice valve throughly from inside and carryout necessary metalling and machinery work the spindle and check nuts and top of sluice valve including replacement of gland packing rope of suitable size, rubber gasket, bolts, nuts etc., and make the sluice valve serviceable for the following sizes complete all as specified and as directed by Engr-in-charge. | |||
54 | 22.01 | 100mm dia | 1 | Each Job | |
55 | 22.02 | 150mm dia | 1 | Each Job | |
56 | 23 | Taking down the existing unserviceable pressure gauge 21kg/ sqcm and fixing new pressure gauge in position with GI nipple in terrece of multistoried building and testing complete all as specified and as directed by Engr-in-charge. | 2 | Each Job | |
57 | 24 | Material and labour for PCC in roof kerb or mud stops, rounded or chamfored on edges type C-1, 1:3:6 (Using 20mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge. | 1 | CUM | |
58 | 25 | Taking out the existing DOL starter from panel upto 7.5 HP capacity motor, cleaning the electronic parts from inside, replacing the unserviceable OLR, contactor, NVC etc., complete all as specified and as directed by Engr-in-charge. | 3 | Each Job | |
59 | 26 | Taking out the existing star delta starter from panel, cleaning the electronic parts from inside and replacing the unserviceable items line the OLR, contactor, NVC, connecting link wires etc., of the following capacity motor complete all as specified and as directed by Engr-in-charge. | |||
60 | 26.01 | 10 HP capacity | 1 | Each Job | |
61 | 26.02 | 15 to 25 HP capacity | 1 | Each Job | |
62 | 26.03 | 30 to 75 HP capacity | 1 | Each Job | |
63 | 27 | Material and labour for preparation of old painted external surfaces of foam tank 4500 ltrs capacity and applying a two coats of synthetic enamel paint of approved tint over a coat of red oxide paint (LRMR BSF - 1 No) complete all as specified and as directed by Engr-in-charge. | 3 | Each Job | |
64 | 28 | Taking down the existing unserviceable foot valve PN 1.6 ball type and supply and fix new foot valve in position with suction line for the following sizes complete all as specified and as directed by Engr-in-charge. | |||
65 | 28.01 | 200mm dia | 1 | Each | |
66 | 28.02 | 80mm dia | 1 | Each | |
67 | 29 | Taking down the existing unserviceable CI butterfly valve 50mm dia supply and fix new valve arrangement flange type PN 1.6 complete with rubber gasket, bolt and nuts, etc., complete all as specified and as directed by Engr-in-charge. | 2 | Each | |
68 | 30 | Supply and lay PVC flexible armoured cable 2 core 1.5 sqmm complete all as specified and as directed by Engr-in-charge. | 95 | RM | |
69 | 31 | Taking up or down steel tubing heavy grade of size 200mm dia from fire fighting pump set suction line complete all as specified and as directed by Engr-in-charge. | 12 | RM | |
70 | 32 | Supply and connect the GI tubing steel galvanised 200mm dia heavy grade with all fittings specials such as bend, elbows, tees, short pieces connection, back nuts, diminishing pieces, caps, plugs and unions etc., including cutting threading and welding complete all as specified and as directed by Engr-in-charge. | 12 | RM | |
71 | 33 | Material and labour for taking down and dismantling centrifugal main pumpset and jockey pumpsets and carrying out repairs, replacement of worn out parts such as impellers, bearings, gland metal bushes etc., and reconditioning of spare parts such as shaft, impellers, housing body, bearing gland plate etc., by metalling and machining to their original shape and size and assembling back into position by using new suitable gland dory, gland plate, gland/ rubber packing including studs/ gland bolts and nuts, coupling bushes etc., oiling and greasing for making pumpset fully functional and testing for satisfactory running complete for the following capacities complete all as specified and as directed by Engr-in-charge.\nNote: Spare parts to be replaced will be measured and paid separately as supply only. | |||
72 | 33.01 | 10 to 15HP | 1 | Each Job | |
73 | 33.02 | 20 to 35 HP | 1 | Each Job | |
74 | 33.03 | 40 to 50 HP | 1 | Each Job | |
75 | 34 | Material and labour for taking down opening centrifugal main pumpset and jockey pumpsets for repair and taking out damaged/ burnt out winding from three phase motor, cleaning the slots with CTC and rewinding the same with new super enamelled copper winding wire of existing gauge and turns, varnishing , baking reassembling and fixing back into position for making motor fully functional and testing for satisfactory running complete for the following capacities complete all as specified and as directed by Engr-in-charge. | |||
76 | 34.01 | 10 to 15HP | 1 | Each Job | |
77 | 34.02 | 20 to 35 HP | 1 | Each Job | |
78 | 34.03 | 40 to 50 HP | 1 | Each Job | |
79 | 35 | Supply and fix for sprinkler glass bulb type (standard response) as per IS:15106 /TAC guidelines 68 degree temperature rating pendent type complete all as specified and as directed by Engr-in-charge. | 12 | Each | |
80 | 36 | Disconnecting the earth strip from the terminal block and pour salt water in to the earth pit for the improvement of the earthvalue, testing and connecting after completion of the job complete all as specified and as directed by Engr-in-charge.\nNote: Earth ressistance test result must not be more than 2 ohms. | 40 | Each Job | |
81 | 37 | Supply and fix for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screws ccomplete all as specified and as directed by Engr-in-charge. | 30 | Each | |
82 | 38 | Supply and fix for air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed by Engr-in-charge. | 35 | Each | |
83 | 39 | Supply and fix on wall /buried in ground or drawn in conduit /pipe earth continuity conductor GI strip of size 32x6mm complete all as specified and as directed by Engr-in-charge. | 85 | RM | |
84 | 40 | Supply and fix on wall/ ceiling aluminium strip 25x3.15mm with saddles and insulators and fixing screws etc., for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-charge. | 390 | RM | |
85 | 41 | Material and labour for galvanized iron tubing 40mm bore light grade with all fitting laid in wall /floor /under road /culvert /on pole for protection of earth strip including providing fixing clamps, bolts and nuts of suitable size complete all as specified and as directed by Engr-in-charge. | 26 | RM | |
86 | 42 | Material and labour for sub main wiring complete with 4 runs of 4 sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/ wall /roof etc., with two runs of PVC insulated, 4 sqmm FRLS cable, copper conductor for earth continuity conductor including taking down the old sub main wiring complete all as specified and as directed by Engr-in-charge. | 50 | RM | |
87 | 43 | Material and labour for maintenance /servicing to electrically operated sliding door of size upto 20m height comprising of motor, gear boxes, chain, electric control panel, wiring and replacing defective minorparts including cleaning, greasing of all the moving parts, checking and testing for smooth functioning of all electical /electronic circuit, motor, gear /mechanical parts etc., complete all as specified and as directed by Engr-in-charge.\nNotes: (i) The major spares required shall be measured and paid under relevant item as supply and fixing.\n(ii) Rate deemed to include labour cost for periodic maintenance including maintenance of record as directed.\n(iii) The quoted rate includes supply and fix for necessary minor spare parts/ accessories like key, chain pin, lugs required for replacement of unserviceable spares/ accessories including welding and machining work of any type.\n(iv) The quoted rate includes consumables like oil /grease and hardware like bolts and nuts, pins, keys etc.,\n(v) This item shall be measured and paid as carried out but minimum interval between each servicing per door is one month. | 160 | Each job | |
88 | 44 | Material and labour for taking down defective electric motor 2HP /3HP, 3 Phase, 415V, 1420 RPM, transporting to private work shop dismatling, opening motor, taking out damaged/ burnt out winding from three phase motor, cleaning the slots with CTC and rewinding the same with new super enamelled copper winding wire of existing gauge and turns, oiling and greasing, reassembling and fixing back into position for making motor fully functional and testing for satisfactory running complete all as specified and as directed by Engr-in-charge. | 5 | Each job | |
89 | 45 | Supply and fix roller chain as per existing specification and length as required at site including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge. | 13 | Each | |
90 | 46 | Supply and fix sprockets with 19 teeths and dia not less than 120mm and hub dia as per existing specification and as required including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge. | 5 | Each | |
91 | 47 | Supply and fix sprockets with 20 teeths and dia not less than 125mm and hub dia as per existing specification and as required including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge. | 4 | Each | |
92 | 48 | Supply and fix ball bearing size 6205 /6206 including taking down unserviceable bearings complete all as specified and as directed by Engr-in-charge.\nMake: NBC/ SKF/ TATA | 20 | Each | |
93 | 49 | Supply and fix for power contactor FP 415 volt, upto 40 Amps as existing including taking down old unserviceable one and making necessary complete all as specified and as directed by Engr-in-charge.\nMake: L&T MNX A1/ Siemens/ Schneider /BCH /ABB | 6 | Each | |
94 | 50 | Supply and fix for power contactor 3 pole and neutral with 1NO + 1NC of capacity AC3, 32 Amps as existing including taking down old unserviceable one and making necessary connection complete all as specified and as directed by Engr-in-charge.\nMake: L&T/ Siemens/ Schneider/ BCH/ ABB | 5 | Each | |
95 | 51 | Supply and fix for RCCB TP 32 Amps capacity including taking down old unserviceable one and making necessary connection complete all as specified and as directed by Engr-in-charge.\nMake: Legrand/ Siemens/ Schneider/ ABB | 8 | Each | |
96 | 52 | Supply and fix for MCB SP 240 volts 6 to 32 Amps 'C' curve with 10KA breaking capacity complete all as specified and as directed by Engr-in-charge.\nMake: Legrand /Siemens /Schneider /ABB | 10 | Each | |
97 | 53 | Supply and fix for MCB TP 415 volts 6 to 32 Amps 'C' curve with 10KA breaking capacity complete all as specified and as directed by Engr-in-charge.\nMake: Legrand /Simens /Schneider /ABB | 4 | Each | |
98 | 54 | Supply and fix for connector /terminal block for incomming and outgoing wires suitable for copper wire upto 6 sqmm including taking down old unserviceable burnt one and making necessary connection complete all as specified and as directed by Engr-in-charge.\nMake: Legrand /Siemens /Schneider /ABB | 12 | Each | |
99 | 55 | Supply and fix for LED indication lamp (Red /Yellow /Blue) as required at site including taking down old unserviceable one and making necessary connection complete all as specified and as directed by Engr-in-charge.\nMake: L&T/ C&S/ HPL/ AE | 18 | Each | |
100 | 56 | Supply and fix for push button spring return (Red /Green) as required at site including taking down old unserviceable one and making necessary connection complete all as specified and as directed by Engr-in-charge.\nMake: L&T /C&S /HPL /AE | 12 | Each | |
101 | 57 | Supply and fix for emergency trip switch mushroom type (Red) as required at site including taking down old unserviceable one and making necessary connection complete all as specified and as directed by Engr-in-charge.\nMake: L&T/ C&S /HPL /AE | 6 | Each | |
102 | 58 | Supply and fix for push button stay put (Press to lock turn release) mushroom head as required at site including taking down old unserviceable one and making necessary connection complete all as specified and as directed by Engr-in-charge.\nMake: L&T /C&S /HPL /AE | 20 | Each | |
103 | 59 | Supply and fix for limit switch in position upto 23m height including taking down old unserviceable one and making necessary connection complete all as specified and as directed by Engr-in-charge.\nMake: L&T /C&S /HPL /AE /Simens /Schneider /ABB | 23 | Each | |
104 | 60 | Supply, installation, testing of hooter (Minimum 100m audible range) cum blinker not less than 10W, 110 /230V and making necessary connections including taking down existing old unserviceable one complete all as specified and as directed by Engr-in-charge. | 6 | Each | |
105 | 61 | Supply and fix for panel lock with key recessed /as per existing type including taking down old unserviceable damaged one complete all as specified and as directed by Engr-in-charge. | 28 | Each | |
106 | 62 | Supply and fix for on pole /wall, buried in ground, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe earth continuity conductor copper earth strip 32x6mm complete all as specified and as directed by Engr-in-charge. | 50 | RM | |
107 | 63 | Material and labour for chemical earthing complete with copper earth plate 900x600x5mm thick buried directly in ground vertically to a depth of not less than 3.5m below ground level, with top edge of the earth plate at a depth of not less than 2.25m below ground connected to copper earth strip 32x6mm by means of brass bolts and nuts, check nuts, washers copper plate surrounded by back fill compound of not less than 100 kg with atleast 5 layers of charcoal and salt crystal and earth strip protected by GI pipe light grade 40mm bore upto 7.5m and connecting to testpoint/ DBs etc., as per site requirement including necessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC 1:2:4 cover with 6mm dia MS bars 10 cm c/c on both ways as reinforcement complete including watering pipe 20mm dia medium grade with funnel complete with mesh complete including testing on completion complete all as specified and as directed by Engr-in-charge.\nNotes: (i) Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc.,\n(ii) Copper earth strip 32x6mm, GI tubing light grade 40mm bore upto 7.5m deemed to be included in the rate quoted by the contractor.\n(iii) Beyond 7.5m the earth strip 32x6mm and GI pipe light grade 40mm bore shall be measured and paid under relevant item of the schedule.\n(iv) Quoted rate include testing after completion from test point and the desired earth resistance shall be not more than 1 ohm. If the desired result is not obtained the earthing will be re-done by the contractor at no extra cost. | 3 | Each | |
108 | 64 | Supply, installation, testing of indoor type factory fabricated control/ operating panel for hanger door including hooter (Minimum 100m audible range) cum blinker and making necessary connections including taking done existing old unserviceable panel complete all as specified and as directed by Engr-in-charge.\nMake: Areen or approved by GE. | 2 | Each job | |
109 | 65 | Material and labour for maintenance /servicing to electrically operated compressor unit Make: ELGI with tank capacity 220 litres and comprising of motor 3 Phase, 7.5 HP, Electric control panel, wiring and replacing defective minor parts including cleaning, greasing of all the moving parts, checking and testing complete all as specified and as directed by Engr-in-charge.\nNotes: (i) The major spares required shall be measured and paid under relevant item as supply and fixing.\n(ii) Rate deemed to include labour cost for periodic maintenance including maintenance of record as directed.\n(iii) The quoted rate includes supply and fix necessary minor spare parts/ accessories like key, lugs required for replacement of unserviceable spares/ accessories including welding and machining work of any type.\n(iv) The quoted rate includes consumables like oil /grease and hardware like bolts and nuts etc.,\n(v) This item shall be measured and paid as carried out but minimum interval between each servicing is one month. | 8 | Each job | |
110 | 66 | Supply and fill air compressor oil suitable for compressor unit complete all as specified and as directed by Engr-in-charge.\nMake: ELGI | 80 | Ltr | |
111 | 67 | Supply and fix for new 'V' belt of specification B-74 and testing including dismantling unserviceable/ wornout 'V' belts any type/ model complete all as specified and as directed by Engr-in-charge.\nMake: FENNER/ DUNLOP/ V GRIP | 3 | Each | |
112 | 68 | Supply and fix in replacement gasket set of compressor unit Make: ELGI complete all as specified and as directed by Engr-in-charge. | 1 | Set | |
113 | 69 | Supply and fix in replacement set of neoprene 'O' ring complete all as specified and as directed by Engr-in-charge. | 1 | Set | |
114 | 70 | Supply and fixing new element filter of air compressor and testing including dismantling unserviceable element filter complete all as specified and as directed by Engr-in-charge. | 2 | Each | |
115 | 71 | Supply and fix in replacement seal oil complete all as specified and as directed by Engr-in-charge. | 2 | Each | |
116 | 72 | Supply and fix for valve breather including dismantling unserviceable one complete all as specified and as directed by Engr-in-charge. | 2 | Each | |
117 | 73 | Supply and fix for bush rubber I/L air filter including dismantling unserviceable one complete all as specified and as directed by Engr-in-charge. | 2 | Each | |
118 | 74 | Supply and laying PVC insulated multistranded copper conductor flexible wire 2.5 sqmm 4 core complete all as specified and as directed by Engr-in-charge.\nMake: POLYCAB/ FINOLEX /PLAZA /Havells | 200 | RM | |
119 | 75 | Supply and laying PVC insulated armoured copper conductor wire 1.5 sqmm 4 core complete all as specified and as directed by Engr-in-charge.\nMake: POLYCAB/ FINOLEX/ PLAZA /Havells | 300 | RM | |
120 | 76 | Taking down old unservicaeble security light junction box/ bus bar box etc., from existing security light poles/ wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc., complete all as specified and as directed by Engr-in-charge. | 98 | Each | |
121 | 77 | Taking down old corroded MS clamp, cross arms, bracings, supports, back plates etc., from existing street light pole of any type complete all as specified and as directed by Engr-in-charge. | 0.2 | Per Qtl | |
122 | 78 | Taking down old corroded steel conduit of any size from existing street light pole of any type /other similar locations complete all as specified and as directed by Engr-in-charge. | 82 | RM | |
123 | 79 | Taking down old/ burnt out cable /aluminium wire from existing street light pole of any type /other similar locations complete all as specified and as directed by Engr-in-charge. | 1300 | RM | |
124 | 80 | Taking down old/ unserviceable/ burnt LED light fittings from existing positions including necessary T & P, ladder etc., as per site requirement carefully, checking of fitting for defect and repair and refixing the same in existing position or any other location after repair complete all as specified and as directed by Engr-in-charge.\nNotes: (i) Spare parts as required shall be arranged by the Deptt from fitting manufacturer aganist their warranty of fittings with Dept, However if any replacement of minor burnt wires require, the same shall be included in the rate quoted.\n(ii) Quoted rate is deemed to be included the charges of T & P, labour, etc., complete as per site requirement. | 68 | Each | |
125 | 81 | Surface excavation not exc 30 cms deep and average 15 cms deep and getting out in soft/ loose soil including removing green vegetation, roots, bushes etc., from surroundings near electric poles /panels or sub stations area complete all as specified and as directed by Engr-in-charge. | 30 | SQM | |
126 | 82 | Material and labour for black stove enamelled rigid ERW steel conduit 20mm dia fixing with suitable size MS clamps/ saddles as per site requirement complete all as specified and as directed by Engr-in-charge.\nMake: BEC/ EMCO/ GARWARE/ JINDAL/ WAVIN /FINOLEX\nNote: New wiring portions for replacement of unserviceable wiring as required as per site requirement shall be measured and paid separately under relevant schedule items. | 82 | RM | |
127 | 83 | Supply and fix for MCB TPN 415 V, 40 to 63 Amps 'C' curve including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge.\nMake: Legrand/ L&T/ Siemens/ Schneider/ABB | 18 | Each | |
128 | 84 | Supply and fix for MCB SP 230 V, 6 to 32 Amps 'C' curve including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge.\nMake: Legrand/ L&T/ Siemens /Schneider /ABB | 35 | Each | |
129 | 85 | Supply and fix for MCB SP 230 V, 40 to 63 Amps 'C' curve including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge.\nMake: Legrand/ L&T/ Siemens /Schneider /ABB | 30 | Each | |
130 | 86 | Supply, fixing and testing powder coated outdoor street light control box of size not less than 300x200x80mm CRCA 3mm thick IP 65 fabricated by CPRI certified panel manufacturer including suitable terminal TPN 10 KA SMC connector (for 3 phase cable line IN and OUT) and provision of dimrail for mounting 3 Nos MCB SP including supply and fix - 01 No MCB 6 A SP 'C' curve (Make: Siemens/ L&T/ Schneider/ Legrand /ABB), canopy weather proof, hinged door with two hinges, pad side locking system - 02 Nos (top and bottom), for fixing on PCC/ steel poles in and including necessary MS clamps - 02 Nos of suitable shape and size with nuts, bolts and washers as per site requirement complete all as specified and as directed by Engr-in-charge.\nNotes: (i) Drawing shall be approved from Deptt by the contractor before placing a order to CPRI certified panel manufacturers.\n(ii) The cost deemed to be included in the quoted rate for reconnecting old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect whereever required as per site requirement complete all as specified and as directed by Engr-in-charge. | 98 | Each Job | |
131 | 87 | Taking down unserviceable LED light fittings of any watt and type from existing position on pole/ wall/ tower/ gate complete for and including repair and refixing in existing position after repair complete all as specified and as directed by Engr-in-charge.\nNotes: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as 'Supply only' under relavent item here-in-after.\n(ii) Labour cost for replacing spare parts, removing unserviceable parts, dismantling light fittings and refixing are deemed to be included in the quoted rate. | 92 | Each | |
132 | 88 | Supply only oudoor drivers any type and following wattage for flood lights /post top latern lights /street light /security lights including necessary connecting arrangements as per site requirement complete all as specified and as directed by Engr-in-charge.\nMake: Philips /Wipro /Surya Roshini Ltd/ Crompton/ Luker Electric Technologies Ltd | |||
133 | 88.01 | Out door type drivers suitable for 25 watts LED lights. | 10 | Each | |
134 | 88.02 | Out door type drivers suitable for 40 watts LED lights. | 8 | Each | |
135 | 88.03 | Out door type drivers suitable for 45 watts LED lights. | 15 | Each | |
136 | 88.04 | Out door type drivers suitable for 75 watts LED lights. | 8 | Each | |
137 | 88.05 | Out door type drivers suitable for 150 watts LED lights. | 6 | Each | |
138 | 89 | Supply only surge protection devices any type and KV for following capacity flood lights/ post top latern lights /street light /security lights including necessary connecting arrangements as per site requirement complete all as specified and as directed by Engr-in-charge.\nMake: Philips /Wipro /Surya Roshini Ltd/ Crompton/ Luker Electric Technologies Ltd | |||
139 | 89.01 | Surge protection devices not less than 5 KV suitable for LED light fittings up to 75 watts. | 25 | Each | |
140 | 89.02 | Surge protection devices not less than 5 KV suitable for LED light fittings 75 watts to 150 watts. | 20 | Each | |
141 | 90 | Supply, fixing and testing LED street light luminaire fitting of not less than 45 watt and IP 65 protection comprises of pressure die cast aluminium housing powder coated, with luminaire efficiancy not less than 100 lm/w provided with surge suppressor 5 KV complete including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed by Engr-in-charge.\nMake: Crompton Cat Part No. LSTS-45-CDL-M /Surya Roshini Ltd Cat Part No. SLE UL 45W IP66 LXN/ Philips /Wipro/ Luker Electric technologies Ltd\nNotes: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement.\n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. | 70 | Each | |
142 | 91 | Supply and draw PVC insulated round copper flexible cable multistranded of 3 core 1.5 sqmm with necessary arrangments complete all as specified and as directed by Engr-in-charge.\nMake: Plaza /Finolex /Gloster /Nicco /Polycab /KEI | 900 | RM | |
143 | 92 | Supply and fix for GI bracket for street light made out of 25mm dia GI pipe medium grade 1.5m length bend in shape as required complete with MS flat iron clamps, nuts and bolts etc., and including dismantling old damaged one complete all as specified and as directed by Engr-in-charge. | 26 | Each | |
144 | 93 | Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer including preparing the surface and old corroded items complete all as specified and as directed by Engr-in-charge. | 0.2 | Qtl | |
145 | 94 | Supply, fixing and testing LED flood light fitting of not less than 100 Watt, luminaire fitting of IP66 protection comprises of pressure die cast aluminium housing powder coated, toughened glass, luminaire efficiancy not less than 100 lm/w provided with surge suppressor 10 KV including taking down the old unserviceable/ damaged light fittings and making good disturbed complete all as specified and as directed by Engr-in-charge.\nMake: Crompton Cat Part No. LFLN-120-CDL/60-M/ Surya Roshini Ltd Cat Part No. SLE FL 100W IP66 LUMOS/ Philips /Wipro /Luker Electric Technologies Ltd\nNotes: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement.\n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. | 13 | Each | |
146 | 95 | Cutting and trimming of tree branches touching street/ security poles or light fittings etc., to clear the tree branches around the pole and maintain a clearance of 1.50m radius of the pole top or light fitting complete all as specified and as directed by Engr-in-charge.\nNotes: (i) An area of 1.5m surrounding the pole to be cleared off trees branches.\n(ii) Measurement and payment will be made for all cutting/ trimming near top of the each pole as one job only. | 62 | Each Job | |
147 | 96 | Supply, fixing and testing LED flood light fitting of not less than 150 watt, luminaire fitting of IP 65 protection comprises of pressure die cast aluminium housing powder coated, toughened glass, luminaire efficiancy not less than 110 lm/w provided with surge suppressor 10 KV including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed by Engr-in-charge.\nMake: Crompton Cat Part No. LFLN-150-CDL/60-M/ Surya Roshini Ltd Cat Part No. SLE FL 150W IP66 LUMOS / Philips /Wipro/ Luker Electric Technologies Ltd\nNotes: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement.\n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. | 10 | Each | |
148 | 97 | Material and labour for earthing complete with using GI earth plate electrode of size 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level, with top edge of the earth plate at a depth of not less than 1.5m below ground and connected to GI earth wire 4mm by means of GI bolts and nuts, check nuts, washers and GI earth wire protected by GI pipe light grade 15mm bore and connecting to panel /DBs etc., as per site requirement including alternate layers of charcoal and salt crystal, necessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover with 6mm dia MS bars 10 cm c/c on both ways as reinforcement complete including watering pipe 20mm dia medium grade with funnel complete with mesh all as shown in electrical plate No.3 of MES schedule part-I complete including testing on completion complete all as specified and as directed by Engr-in-charge.\nNotes: (i) Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc.,\n(ii) GI earth wire, GI tubing light grade 15mm bore upto 7.5m deemed to be included in the rate quoted by the contractor.\n(iii) Quoted rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm. If the desired result is not obtained the earthing will be re-done by the contractor at no extra cost. | 9 | Each | |
149 | 98 | Supply, fixing and testing LED street light luminaire fitting of not less than 25 Watt of IP66 protection comprises of pressure die cast aluminium housing powder coated, with luminaire efficiancy not less than 100 lm/w provided complete including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed by Engr-in-charge.\nMake: Crompton Cat Part No. LSTS-25-CDL-M/ Surya Roshini Ltd Cat Part No. SLE UL 25W IP66 LXN/ Philips /Wipro/ Luker Electric Technologies Ltd\nNotes: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement.\n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. | 35 | Each | |
150 | 99 | Material and labour for PCC 1:2:4 type B-1 (Using 20mm grade stone aggregate) as in coping of electric pole at site including providing necessary formwork complete all as specified and as directed by Engr-in-charge. | 1 | CUM | |
151 | 100 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multistrand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multistrand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn in existing conduit complete all as specified and as directed by Engr-in-charge. | 400 | RM | |
152 | 101 | Supply, fixing and testing LED street light luminaire fitting of not less than 60 Watt, luminaire fitting of IP 66 protection comprises of pressure die cast aluminium housing powder coated, with luminaire efficiancy not less than 100 lm/w provided with surge Suppressor 5 KV complete including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed by Engr-in-charge.\nMake: Crompton Cat Part No. LST-60-CDL /Surya Roshini Ltd Cat Part No. SLE UL 60W IP66 LXN/ Philips /Wipro/ Luker Electric Technologies Ltd\nNotes: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement.\n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. | 32 | Each | |
153 | 102 | Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for taking up/ laying cable etc., and getting out for soft /loose soil complete all as specified and as directed by Engr-in-charge. | 306 | Cum | |
154 | 103 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cms for soft/ loose soil complete all as specified and as directed by Engr-in-charge. | 195 | Cum | |
155 | 104 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge. | 21 | Cum | |
156 | 105 | Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and as directed by Engr-in-charge. | 6 | Per 1000 Nos | |
157 | 106 | Relaying of reusable bricks as obtained from item No.102 here-in-before complete all as specified and as directed by Engr-in-charge. | 3 | Per 1000 Nos | |
158 | 107 | Spreading riddled earth as obtained from item No.102 here-in-before in cable trenches complete all as specified and as directed by Engr-in-charge. | 90 | Cum | |
159 | 108 | Supply and lay pipe galvanised iron tubing light grade of 40mm dia in trenches/ under road or floor /on wall /near pole /panel etc., as per site requirement complete all as specified and as directed by Engr-in-charge. | 72 | RM | |
160 | 109 | Supply and laying for 16 sqmm 4 core XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor for replacement of unserviceable portion of cable, connecting with proper size aluminium lugs, glands whereever necessary near LT panels/ bus bar chamber panel/ joints /poles including taking down the old unsevicaeble cable all as per site requirement, including testing complete all as specified and as directed by Engr-in-charge.\nMake: UNIVERSAL/ POLYCAB/ NICCO/ PLAZA/ Havells/ KEI | 840 | RM | |
161 | 110 | All as per item No.109 here-in-before but 25 Sqmm cross sectional area 4 core cable complete all as specified and as directed by Engr-in-charge.\nMake: UNIVERSAL/ POLYCAB/ NICCO/ PLAZA/ Havells/ KEI | 440 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail