For Extension Of Supply To 180 Nos 1-Ph Each 1Kw Domestic Load, 4Nos 3-Ph Each 5Kw For Bore Well Submersible Pump Sets For Water Supply, 3Nos 3-Ph Each 5Kw For Lifts And Others,1Nos 3Ph 10Kw Sumersible Pump Sets For Water Storage,1Nos Each 5Kw For Street, RANGAREDDY-Telangana

Southern Power Distribution Company of Telangana Limited-TSSPDCL has published For Extension Of Supply To 180 Nos 1-Ph Each 1Kw Domestic Load, 4Nos 3-Ph Each 5Kw For Bore Well Submersible Pump Sets For Water Supply, 3Nos 3-Ph Each 5Kw For Lifts And Others,1Nos 3Ph 10Kw Sumersible Pump Sets For Water Storage,1Nos Each 5Kw For Street. Submission Date for this Tender is 18-11-2020. Passenger Lift Tenders in RANGAREDDY Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

25792632
Corrigendum : For Extension Of Supply To 180 Nos 1-Ph Each 1Kw Domestic Load, 4Nos 3-Ph Each 5Kw For Bore Well Submersible Pump Sets For Water Supply, 3Nos 3-Ph Each 5Kw For Lifts And Others,1Nos 3Ph 10Kw Sumersible Pump Sets For Water Storage,1Nos Each 5Kw For Street
Open Tender
Indian
Telangana
RANGAREDDY
18-11-2020

Tender Details

For Extension Of Supply To 180 Nos 1-Ph Each 1Kw Domestic Load, 4Nos 3-Ph Each 5Kw For Bore Well Submersible Pump Sets For Water Supply, 3Nos 3-Ph Each 5Kw For Lifts And Others,1Nos 3Ph 10Kw Sumersible Pump Sets For Water Storage,1Nos Each 5Kw For Street Lights ,1No 3-Ph 3.75 Kw For Stp And Making Total Load Of 233.75Kw To 2Bhk Housing Colony In C+S+9 Pattern With Related Infrastructure Work At Abdulapur(V) In Abdulapurmet (M) Ibrahimpatnam Subdivision Of Saroorngar Circle

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31/10/2020 0 SOUTHERN POWER DISTRIBUTION COMPANY OF TELANGANA L-SE OPERATIONS SAROORNAGAR CIRCLE Due to non response of bid tender has been extende 07-11-2020
2 12/11/2020 0 SOUTHERN POWER DISTRIBUTION COMPANY OF TELANGANA L-SE OPERATIONS SAROORNAGAR CIRCLE Due to non response of bid tender has been extende 18-11-2020

Key Value

Document Fees
Refer document
EMD
INR 23791.0 /-
Tender Value
INR 11.89 Lakhs /-

BOQ Items

S.No Subwork Name Specification Number Quantity UOM Rate(INR) Amount(INR)
1 2BHK Abdullapurmet As per relevent standard specification 45.00 M2 1550.00 69750.00
Supply and Fabrication of Fencing with welded wire mesh.
2 2BHK Abdullapurmet As per relevent standard specification 190.00 EA 19.00 3610.00
Providing screws,nuts etc- energy meter
3 2BHK Abdullapurmet As per relevent standard specification 10.00 EA 74.00 740.00
Fixing of 3Ph meters in the box
4 2BHK Abdullapurmet As per relevent standard specification 180.00 EA 53.00 9540.00
Fixing of 1Ph meters in the box
5 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 202.00 202.00
UNLOADING of LT AB Cable (XLPE) 1 Core
6 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 393.00 393.00
LOADING of LT AB Cable (XLPE) 1 Core
7 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 185.00 185.00
UNLOADING of Three Phase Meters-100 lot
8 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 185.00 185.00
LOADING of Three Phase Meters 100nos lot
9 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 128.00 128.00
UNLOADING of Single phase Meters-100 lot
10 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 128.00 128.00
LOADING of Single phase Meters 100nos lot
11 2BHK Abdullapurmet As per relevent standard specification 20.00 EA 27.00 540.00
Fixing of PVC Cleats for LT cable
12 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 363.00 726.00
Sub transport of 9.1Mt PSCC Pole from RR Stores to work site including loading &unloading charges
13 2BHK Abdullapurmet As per relevent standard specification 1.08 M3 5160.00 5572.80
Mass concreting of Supports with 40 mm HBG metal using 1:4:8 CC including cost of all materials and curing after concreting (River sand metal, cement water shall be procured by the contractor) (0.56 cum/pole)
14 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 1621.00 3242.00
Erection of 9.1M PSCC pole in position, aligning and setting to work, fixing of cross arms and top clamps, earthing of supports, back filling with earth and stones properly ramming including transport of materials from road side to location excluding pit excavation
15 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 364.00 728.00
Excavation of pits in all soils except hard rock requiring blasting(2.6" x 2.6" x 5.0\)
16 2BHK Abdullapurmet As per relevent standard specification 0.10 TO 221.00 22.10
LOADING of MS Channel,Angles,Flats&Rods
17 2BHK Abdullapurmet As per relevent standard specification 0.10 TO 185.00 18.50
UNLOADING of MS Channel,Angles,Flats&Rod
18 2BHK Abdullapurmet As per relevent standard specification 1.00 DR 202.00 202.00
Unload-LT XLPE UG Cable all size
19 2BHK Abdullapurmet As per relevent standard specification 1.00 DR 393.00 393.00
Load-LT XLPE UG Cable for all size
20 2BHK Abdullapurmet As per relevent standard specification 3.00 EA 15.00 45.00
UNLOADING of 3PLTTriv meter with PVC box
21 2BHK Abdullapurmet As per relevent standard specification 3.00 EA 15.00 45.00
LOADING of 3PLTTriv meter with PVC box
22 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 18.00 36.00
UNLOADING of 11 KV HG Fuse Sets
23 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 18.00 36.00
LOADING of 11 KV HG Fuse Sets
24 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 441.00 441.00
UNLOADING of 160&250kva DTR
25 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 468.00 468.00
LOADING of 160&250kva DTR
26 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 280.00 280.00
UNLOADING of 50,63,75&100kva DTR
27 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 350.00 350.00
LOADING of 50,63,75&100kva DTR
28 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 2667.00 2667.00
Transport of conductor drums, cable drums, fragile material such as kiosks, VCBs, control panels, current transformers, boosters, lightning arrestors, insulators, transformers, meters (which are less in weight and occupy more space) (excluding of loading unloading) Upto 10 Km with Lorry for each trip
29 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 2420.00 2420.00
Erection of 3 Phase 160kva Distribution Transformer Erection of 9.1M 280Kg WL PSCC Pole , excavation pit of 2 1/2\ x 2 1/2\ x 5\ size and erection of single pole structure including concreting of pole, supply and fabrication of top channel, cross channel, angles for AB Switch supporting and fixing of channels and angles & erection of clamps etc,. (Including support angle in between tapping and AB Switch)
30 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 1906.00 1906.00
Erection of 3 Phase 100kva Distribution Transformer Erection of 9.1M 280Kg WL PSCC Pole , excavation pit of 2 1/2\ x 2 1/2\ x 5\ size and erection of single pole structure including concreting of pole, supply and fabrication of top channel, cross channel, angles for AB Switch supporting and fixing of channels and angles & erection of clamps etc,. (Including support angle in between tapping and AB Switch)
31 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 142.00 284.00
Painting of AB switch Operating rods with PO red paint
32 2BHK Abdullapurmet As per relevent standard specification 5.00 EA 50.00 250.00
Painting of Name on Panel boards
33 2BHK Abdullapurmet As per relevent standard specification 5.00 EA 116.00 580.00
Supply of Danger boards with clamps
34 2BHK Abdullapurmet As per relevent standard specification 60.00 M 307.00 18420.00
Supply of 2" B class GI pipe
35 2BHK Abdullapurmet As per relevent standard specification 10.00 EA 3500.00 35000.00
Supply & erection of indoor type Metering Pannel -3 Ph (1 Mtr) box with 14SWG CRCA sheet steel duly fabricating complete with cleaning 7 tank process & painting with 2coats of powder coating enamel painting inter locking arrangement and air vent provision on side of the box. Complete erection of panel and fixing of all above items, testing, commissioning as directed by department officers ( approx. 11X11 inches (LXB ) for each single phase meter box for each meter with 4sqmm copper cable with standard make for internal connections (wiring) and 63A MCB with ISI standard for each meter , 1no. rated MCB 3 pole for incoming supply for each panel board with Aluminium bus bar of size 10X20 mm with 1 no junction box/distribution box for 2 no. panel boards
36 2BHK Abdullapurmet As per relevent standard specification 200.00 M 20.00 4000.00
Laying of 1Core XLPE 120Sqmm Cable at apartments only.
37 2BHK Abdullapurmet As per relevent standard specification 300.00 M 157.00 47100.00
Laying of XLPE UG cable LT 3 1/2 x 95 Sqmm at apartments only.
38 2BHK Abdullapurmet As per relevent standard specification 10.00 EA 2441.00 24410.00
Supply of CI Pipe earthing 50mm dia 2m long
39 2BHK Abdullapurmet As per relevent standard specification 5.00 LS 2535.00 12675.00
Construction of platform for erection of meter panel board with construction of 2 Nos. of 6 blocks of brick masonry of size (2\x9"x3\) or (0.6x0.23x0.9m) with (0.3m) 1\ ht below ground level and (0.6m) 2\ ht along ground level with plastering to the exposed surface including cost & conveyance of all meterials
40 2BHK Abdullapurmet As per relevent standard specification 50.00 EA 11.00 550.00
Supply of LT Lugs
41 2BHK Abdullapurmet As per relevent standard specification 20.00 EA 35.00 700.00
Supply of PVC cleats
42 2BHK Abdullapurmet As per relevent standard specification 100.00 KG 94.00 9400.00
Supply of supporting GI Bolts & Nuts,Washers etc.,
43 2BHK Abdullapurmet As per relevent standard specification 16.00 EA 386.00 6176.00
Providing of RCC Collar guarding to the existing earth pits with damaged masonry including dismantling and removing of existing masonry and fixing the RCC collar of 0.60 M dia X 0.50 M height
44 2BHK Abdullapurmet As per relevent standard specification 16.00 EA 1100.00 17600.00
Providing of earthing with excavation of earth pit (0.6 x0.6x2.4 Mts.) duly filling with bentonite powder, earth, running of earth wire etc., complete, including cost of bentonite powder
45 2BHK Abdullapurmet As per relevent standard specification 180.00 EA 2000.00 360000.00
Supply & erection of indoor type Metering Pannel -1 Ph (1 Mtr) box with 14SWG CRCA sheet steel duly fabricating complete with cleaning 7 tank process & painting with 2coats of powder coating enamel painting inter locking arrangement and air vent provision on side of the box. Complete erection of panel and fixing of all above items, testing, commissioning as directed by department officers ( approx. 11X11 inches (LXB ) for each single phase meter box for each meter with 4sqmm copper cable with standard make for internal connections (wiring) and 32A MCB with ISI standard for each meter , 1no. rated MCB 3 pole for incoming supply for each panel board with Aluminium bus bar of size 10X20 mm with 1 no junction box/distribution box for 2 no. panel boards
46 2BHK Abdullapurmet As per relevent standard specification 50.00 EA 9.00 450.00
Cutting Charges for MS channel 75x40mm
47 2BHK Abdullapurmet As per relevent standard specification 50.00 EA 15.00 750.00
Fabrication of Back clamps(50 x 6 mm) MS Flat with 2 coats of Red oxide painting
48 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 110.00 220.00
Painting of Structure/DTR Code & Location Name
49 2BHK Abdullapurmet As per relevent standard specification 2.00 SET 80.00 160.00
UNLOADING of 11 KV AB SWCH T.T.200/400 A
50 2BHK Abdullapurmet As per relevent standard specification 2.00 SET 80.00 160.00
LOADING of 11 KV AB SWCH T.T.200/400 A
51 2BHK Abdullapurmet As per relevent standard specification 50.00 KG 84.00 4200.00
Supply and Earthing GI Wire No 8 including material
52 2BHK Abdullapurmet As per relevent standard specification 140.00 KG 84.00 11760.00
Supply and Earthing of GI flat 25x3 mm including material
53 2BHK Abdullapurmet As per relevent standard specification 6.00 EA 2789.00 16734.00
Supply of 80mm dia 6mm thick 2.75Mtrs. long CI earth pipe with excavation of earth pit (0.6 x0.6x2.4 Mts.) duly filling with bentonite, earth , running of earth wire etc., complete, including cost of bentonite, RCC collar of size 0.6M dia x 0.5 M height
54 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 25650.00 51300.00
Construction of RCC Column Type Plinth of column size 1\x1\x13\, footing size 5\x5\x9", slab size 5\x5\x6", beam size 5\x9"x9" above ground 8\ (ft) and below the ground 5\ (ft) along with sub-base of 5\x5\x6" with PCC (1:4:8) of 40mm metal including plastering
55 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 330.00 660.00
Running of 11 KV jumpering to 11 KV AB switch, HG Fuse set and distribution transformers terminal etc. complete
56 2BHK Abdullapurmet As per relevent standard specification 3.00 EA 866.00 2598.00
Erection of CT Meters on LV Side of DTR?s including transportation and accessories like Lugs, clamps but excluding cable
57 2BHK Abdullapurmet As per relevent standard specification 3.00 EA 1242.00 3726.00
Erection of LT distribution box including laying of LT cable from distribution box to LT OH line and DTR to distribution box including earthing of distribution box and crimping of lugs connecting of jumpers etc(Including PVC Cleats)
58 2BHK Abdullapurmet As per relevent standard specification 2.00 SET 660.00 1320.00
Erection of 11 KV HG Fuse set including earthing in existing Substation
59 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 1405.00 2810.00
Erection of 11 KVAB Switch 200 A tilting type including alignment and earthing
60 2BHK Abdullapurmet As per relevent standard specification 1.00 KM 3985.30 3985.30
Paving out and stringing of LT 1-Phase (2 Conductors with conductor size of 34/55sqmm) conductor by providing temporary stays, tensioning, sagging correctly, fixing strain points, transferring to pin points binding, keeping stifner, rectification of poles, guys and jumpering etc., including transport of material from road side to location.
61 2BHK Abdullapurmet As per relevent standard specification 0.50 KM 500.00 250.00
survey of line&cable including peg mark&tree clear
62 2BHK Abdullapurmet As per relevent standard specification 20.00 EA 363.00 7260.00
Sub transport of 9.1Mt PSCC Pole from RR Stores to work site including loading &unloading charges
63 2BHK Abdullapurmet As per relevent standard specification 22.00 EA 1.00 22.00
UNLOADING of LT Three phase cross arms
64 2BHK Abdullapurmet As per relevent standard specification 22.00 EA 1.00 22.00
LOADING of LT Three phase cross arms
65 2BHK Abdullapurmet As per relevent standard specification 1.00 LS 38.00 38.00
UNLOADING of LTPins
66 2BHK Abdullapurmet As per relevent standard specification 1.00 LS 54.00 54.00
LOADING of LTPins
67 2BHK Abdullapurmet As per relevent standard specification 1.00 BAG 35.00 35.00
UNLOADING of LT Metal parts - bag of 100
68 2BHK Abdullapurmet As per relevent standard specification 1.00 BAG 52.00 52.00
LOADING of LT Metal parts-Bag of 100nos
69 2BHK Abdullapurmet As per relevent standard specification 1.00 BAG 21.00 21.00
UNLOADING of LT Shackle insulators
70 2BHK Abdullapurmet As per relevent standard specification 1.00 BAG 26.00 26.00
LOADING of LT Shackle insulators
71 2BHK Abdullapurmet As per relevent standard specification 1.00 BAG 18.00 18.00
UNLOADING of LT Pin insulators
72 2BHK Abdullapurmet As per relevent standard specification 1.00 BAG 26.00 26.00
LOADING of LT Pin insulators
73 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 50.00 100.00
Fixing of 1Phase 1Pole MCB make:Hager/ABB/legrand/Siem
74 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 230.00 460.00
Supply of 1Phase 1Pole MCB make:Hager/ABB/legrand/Siemn
75 2BHK Abdullapurmet As per relevent standard specification 50.00 EA 9.00 450.00
Cutting Charges for MS channel 75x40mm
76 2BHK Abdullapurmet As per relevent standard specification 20.00 EA 1621.00 32420.00
Erection of 9.1 mt PSCC poles in positioning,aligning and setting to work , fixing of cross arms and top clamps earthing of supports,back fitting with earth and stones properly ramming including transport of materials from road side to location excluding pit excavation
77 2BHK Abdullapurmet As per relevent standard specification 150.00 M 25.00 3750.00
Supply&Fixing of 2.5sqmm PVC Wire for secondary conncetions for HT services
78 2BHK Abdullapurmet As per relevent standard specification 8.00 BAG 4.00 32.00
UNLOADING of 11 KV Stay Set
79 2BHK Abdullapurmet As per relevent standard specification 8.00 BAG 4.00 32.00
LOADING of 11 KV Stay Set
80 2BHK Abdullapurmet As per relevent standard specification 0.50 TO 185.00 92.50
UNLOADING of MS Channel,Angles,Flats&Rod
81 2BHK Abdullapurmet As per relevent standard specification 0.50 TO 221.00 110.50
LOADING of MS Channel,Angles,Flats&Rods
82 2BHK Abdullapurmet As per relevent standard specification 1.00 TO 333.00 333.00
Transport of iron materials such as R.S. Joists, Rail Poles, fabricated supports, steel, iron, flat, M.S. Channels etc., by lorries. (excluding of loading & unloading ) UPTO 10KM
83 2BHK Abdullapurmet As per relevent standard specification 1.00 TO 326.00 326.00
Transport of steel including line materials such as cross arms, clamps, hardware, cable (loose) and other line materials (Including loading and unloading) upto 10KM
84 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 2667.00 2667.00
Transport of conductor drums, cable drums, fragile material such as kiosks, VCBs, control panels, current transformers, boosters, lightning arrestors, insulators, transformers, meters (which are less in weight and occupy more space) (excluding of loading unloading) Upto 10 Km with Lorry for each trip
85 2BHK Abdullapurmet As per relevent standard specification 0.50 KM 9991.00 4995.50
Paving out conductor LT 3phase 5 W line (55sqmm conductor) by providing temporary stays, tensioning, sagging correctly, fixing strain points, transferring to pin points binding, keeping stifner, rectification of poles, guys and jumpering etc., including transport of material from road side to location.
86 2BHK Abdullapurmet As per relevent standard specification 10.00 EA 938.00 9380.00
Formation of LTCut point(Vertical/ Horizontal) single circuit
87 2BHK Abdullapurmet As per relevent standard specification 100.00 KG 84.00 8400.00
Supply and Earthing GI Wire No 8 including material
88 2BHK Abdullapurmet As per relevent standard specification 16.00 EA 1268.00 20288.00
Fixing of Metal halide lamps with fixtures ake: philips,Crompton,Bajaj junction box with MCB with 1.5 GI pipe complete.
89 2BHK Abdullapurmet As per relevent standard specification 16.00 EA 8200.00 131200.00
Supply of 90W LED fixture set of reputed make with minimum 120 Lm/W Lumens Output, 105 V to 295 V Voltage range, more than 0.94 Power factor, Pressure Die cast Alluminium housing, Powder coated/ anodized finishing, toughed glass lamp cover, IP65 ingress protection, less than 25% THD, minimum 70% electronic efficiency, minimum 140 degrees along the road & 80 degrees across the road beam angle, 4500 to 6500K Color temperature, very low mercury 6.4mg max, Life more than 50,000 burning hours, maximum 20% depreciation during life, Fully cut off control of distribution, Electronic Ballast driver type, minimum 10KV Surge withstand capacity, Poly carbonate reflector/ Poly Carbonate Lens secondary optics, suitable for fixing to existing poles in the Substations, with five years warranty
90 2BHK Abdullapurmet As per relevent standard specification 50.00 EA 7.00 350.00
Cutting Charges for MS angle all sizes
91 2BHK Abdullapurmet As per relevent standard specification 60.00 EA 15.00 900.00
Fabrication of Back clamps(50 x 6 mm) MS Flat with 2 coats of Red oxide painting
92 2BHK Abdullapurmet As per relevent standard specification 30.00 EA 32.00 960.00
Fabrication of LT 3-Ph cross arms MS angle 50x50x6 with two coats of Red Oxide Painting
93 2BHK Abdullapurmet As per relevent standard specification 100.00 KG 94.00 9400.00
Supply of supporting GI Bolts & Nuts,Washers etc.,
94 2BHK Abdullapurmet As per relevent standard specification 10.00 EA 242.00 2420.00
Sub transport of 8Mt PSCC Pole from RR Stores to work site including loading &unloading charges
95 2BHK Abdullapurmet As per relevent standard specification 8.00 EA 254.00 2032.00
Excavation of Stay pits of size 0.45x0.45x1.34 Mts\ for burying the anchor rod with anchor plateof stay sets including dewatering, shoring, shuttering wherever necessary and back filling the pit
96 2BHK Abdullapurmet As per relevent standard specification 18.40 M3 5160.00 94944.00
Mass concreting of Supports with 40 mm HBG metal using 1:4:8 CC including cost of all materials and curing after concreting (River sand metal, cement water shall be procured by the contractor) (0.56 cum/pole)
97 2BHK Abdullapurmet As per relevent standard specification 8.00 SET 475.00 3800.00
Assembly and erection of 11KV&LT stay set including fixing of guy insulators, clamps etc., on the pole and fixing stay wire and binding securely on either side as per standards, transport of material from road side to location and back filling with earth ramming
98 2BHK Abdullapurmet As per relevent standard specification 10.00 EA 894.00 8940.00
Erection of 8.0 mt PSCC poles in positioning,aligning and setting to work , fixing of cross arms and top clamps earthing of supports,back fitting with earth and stones properly ramming including transport of materials from road side to location excluding pit excavation
99 2BHK Abdullapurmet As per relevent standard specification 14.00 EA 2095.00 29330.00
Excavation of pits in hard rock requiring blasting. (other than SS) (2.6" x 2.6" x 5.0\) 0.88 cum
100 2BHK Abdullapurmet As per relevent standard specification 16.00 EA 364.00 5824.00
Excavation of pits in all soils except hard rock requiring blasting(2.6" x 2.6" x 5.0\)
101 2BHK Abdullapurmet As per relevent standard specification 12.00 CRT 2.00 24.00
UNLOADING of 33 & 11 KV Disc insulator
102 2BHK Abdullapurmet As per relevent standard specification 12.00 CAR 2.00 24.00
LOADING of 33 & 11 KV Disc insulators
103 2BHK Abdullapurmet As per relevent standard specification 1.00 SET 48.00 48.00
UNLOADING of 11 KV Metal parts Bag
104 2BHK Abdullapurmet As per relevent standard specification 1.00 SET 48.00 48.00
LOADING of 11 KV Metal parts
105 2BHK Abdullapurmet As per relevent standard specification 15.00 EA 1.00 15.00
Unloading of 11KV Polymer Pin Insulators with GI pins
106 2BHK Abdullapurmet As per relevent standard specification 15.00 EA 1.00 15.00
Loading of 11KV Polymer Pin Insulator with GI pins
107 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 3.00 6.00
UNLOADING of 11 KV V - Cross arms
108 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 3.00 6.00
LOADING of 11 KV V - Cross arms
109 2BHK Abdullapurmet As per relevent standard specification 2.00 BAG 4.00 8.00
UNLOADING of 11 KV Stay Set
110 2BHK Abdullapurmet As per relevent standard specification 2.00 BAG 4.00 8.00
LOADING of 11 KV Stay Set
111 2BHK Abdullapurmet As per relevent standard specification 0.50 TO 185.00 92.50
UNLOADING of MS Channel,Angles,Flats&Rod
112 2BHK Abdullapurmet As per relevent standard specification 0.50 TO 221.00 110.50
LOADING of MS Channel,Angles,Flats&Rods
113 2BHK Abdullapurmet As per relevent standard specification 1.00 TO 333.00 333.00
Transport of iron materials such as R.S. Joists, Rail Poles, fabricated supports, steel, iron, flat, M.S. Channels etc., by lorries. (excluding of loading & unloading ) UPTO 10KM
114 2BHK Abdullapurmet As per relevent standard specification 1.00 TO 326.00 326.00
Transport of steel including line materials such as cross arms, clamps, hardware, cable (loose) and other line materials (Including loading and unloading) upto 10KM
115 2BHK Abdullapurmet As per relevent standard specification 1.00 EA 2667.00 2667.00
Transport of conductor drums, cable drums, fragile material such as kiosks, VCBs, control panels, current transformers, boosters, lightning arrestors, insulators, transformers, meters (which are less in weight and occupy more space) (excluding of loading unloading) Upto 10 Km with Lorry for each trip
116 2BHK Abdullapurmet As per relevent standard specification 7.00 EA 30.00 210.00
Numbering of poles including cost of paint
117 2BHK Abdullapurmet As per relevent standard specification 5.00 EA 7.00 35.00
Cutting Charges for MS angle all sizes
118 2BHK Abdullapurmet As per relevent standard specification 5.00 EA 386.00 1930.00
Coil earthing of pole with No.8 GI wire including supply of nutbolts with pit size 0.76x0.76x1.83 mts in all soils except hard rock
119 2BHK Abdullapurmet As per relevent standard specification 8.00 EA 15.00 120.00
Fabrication of Back clamps with 50 x 6 mm MS Flat including 2 coats of Red oxide painting
120 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 1119.00 2238.00
Formation of Horizontal Cut point for 11 KV Single Circuit line excluding pole erection and stays
121 2BHK Abdullapurmet As per relevent standard specification 0.10 KM 7469.00 746.90
Paving out of conductor 55sqmm 33/11kv Line 3 Cond single circuit providing temporary stays and tensioning, sagging correctly pin binding, including transportation material to work site
122 2BHK Abdullapurmet As per relevent standard specification 0.10 KM 500.00 50.00
survey of line&cable including peg mark&tree clear
123 2BHK Abdullapurmet As per relevent standard specification 5.00 EA 363.00 1815.00
Sub transport of 9.1Mt PSCC Pole from RR Stores to work site including loading &unloading charges
124 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 242.00 484.00
Sub transport of 8Mt PSCC Pole from RR Stores to work site including loading &unloading charges
125 2BHK Abdullapurmet As per relevent standard specification 60.00 KG 94.00 5640.00
Supply of supporting GI Bolts & Nuts,Washers etc.,
126 2BHK Abdullapurmet As per relevent standard specification 5.38 M3 5160.00 27760.80
Mass concreting of Supports with 40 mm HBG metal using 1:4:8 CC including cost of all materials and curing after concreting (River sand metal, cement water shall be procured by the contractor) (0.56 cum/pole)
127 2BHK Abdullapurmet As per relevent standard specification 2.00 SET 475.00 950.00
Assembly and erection of 11KV&LT stay set including fixing of guy insulators, clamps etc., on the pole and fixing stay wire and binding securely on either side as per standards, transport of material from road side to location and back filling with earth ramming
128 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 894.00 1788.00
Erection of 8.0 mt PSCC poles in positioning,aligning and setting to work , fixing of cross arms and top clamps earthing of supports,back fitting with earth and stones properly ramming including transport of materials from road side to location excluding pit excavation
129 2BHK Abdullapurmet As per relevent standard specification 5.00 EA 1621.00 8105.00
Erection of 9.1M PSCC pole in position, aligning and setting to work, fixing of cross arms and top clamps, earthing of supports, back filling with earth and stones properly ramming including transport of materials from road side to location excluding pit excavation
130 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 254.00 508.00
Excavation of Stay pits of size 0.45x0.45x1.34 Mts\ for burying the anchor rod with anchor plateof stay sets including dewatering, shoring, shuttering wherever necessary and back filling the pit
131 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 2095.00 4190.00
Excavation of pits in hard rock requiring blasting. (other than SS) (2.6" x 2.6" x 5.0\) 0.88 cum
132 2BHK Abdullapurmet As per relevent standard specification 2.00 EA 364.00 728.00
Excavation of pits in all soils except hard rock requiring blasting(2.6" x 2.6" x 5.0\)
133 2BHK Abdullapurmet As per relevent standard specification 3.00 EA 1260.00 3780.00
Excavation of pits in hard rock not requiring blasting. (In hard murram / rock boulders)0.76 M x 0.76M x 1.83M (2.6" x 2.6" x 5.0\) 0.88 cum
134 2BHK Abdullapurmet APSS/Morth CI.Number (Upto 200 characters) 0 UOM (upto 50 0 0
Item Detailed Specification Description
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail