Special Repair To Internal Electrical Wiring Of The Bldg No Np-12 P-12 P-03 And P-01 Under Age E/M Of Ge ( North ) Udhampur Ge/U ( N ) -62/2020-21 Special Repair To Internal Electrical Wiring Of The Bldg No Np-12 P-12 P-03 And P-01 Under Age E/M Of Ge, UDHAMPUR-Jammu And Kashmir

Military Engineer Services-MES has published Special Repair To Internal Electrical Wiring Of The Bldg No Np-12 P-12 P-03 And P-01 Under Age E/M Of Ge ( North ) Udhampur Ge/U ( N ) -62/2020-21 Special Repair To Internal Electrical Wiring Of The Bldg No Np-12 P-12 P-03 And P-01 Under Age E/M Of Ge. Submission Date for this Tender is 09-11-2020. Electrification Work Tenders in UDHAMPUR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25792548
Special Repair To Internal Electrical Wiring Of The Bldg No Np-12 P-12 P-03 And P-01 Under Age E/M Of Ge ( North ) Udhampur Ge/U ( N ) -62/2020-21 Special Repair To Internal Electrical Wiring Of The Bldg No Np-12 P-12 P-03 And P-01 Under Age E/M Of Ge
Open Tender
Indian
Jammu And Kashmir
UDHAMPUR
09-11-2020

Tender Details

Special Repair To Internal Electrical Wiring Of The Bldg No Np-12 P-12 P-03 And P-01 Under Age E / M Of Ge ( North ) Udhampur Ge / U ( N ) -62 / 2020-21 Special Repair To Internal Electrical Wiring Of The Bldg No Np-12 P-12 P-03 And P-01 Under Age E / M Of Ge ( North ) Udhampur

Key Value

Document Fees
INR 500 /-
EMD
INR 81000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPECIAL REPAIR TO INTERNAL ELECTRICAL WIRING OF THE BLDG NO NP 12, P 12, P 03 AND P 01 UNDER AGE E/M OF GE (NORTH) UDHAMPUR.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down carefully the existing Copper/Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr -in- charge.\nNote : (i) Old dismanteled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit. 1232 Per Point
2 2 Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as, LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by Engineer in charge. 93 Each
3 3 M&L for complete for one light/fan point wiring with 1.5 Sqmm single core multi stranded copper conductor FR-LSH insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FR-LSH insulated drawn into and including concealed PVC rigid conduit not less than 20.0 mm dia ISI marked terminated into modular white cover plate with frame(as per site required), modular metal flush box (as per site required) ISI marked and modular all accessary complete, making good the disturbed (white washing / colour washing / distembering) surfaces to match with existing specifications, all as specified and as directed by the Engr-in-Charge. Note ;- Necessary wall cutting/chasing for conduit/fixture will be done through electrical cutter machine only. 592 Per Point
4 4 All as per item No. 03 above but for bell / buzzer on independent board controlled by one push button bell switch. 14 Per point
5 5 All as per item Srl No. 03 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge. 96 Per Point
6 6 All as per item No. 03 above but for one 5 Amps socket outlet on independent board. 204 Per point
7 7 All as per item No. 03 above but wire size 2x4 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 4 Sqmm. 326 Per point
8 8 All as per item No. 03 above but wire size 2x4 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on same board and providing earth continuity wire using PVC insulated, FR-LSH 1100 volts grade un sheathed single core stranded copper conductor cable of size 4 Sqmm. 43 Per point
9 9 S&F Modular switch 1 way 6A, 1 module single pole, all as specified and directed by Engineer- in - Charge. 892 Each
10 10 S&F Modular socket, 6A - 2/3 pin 2 module complete all as specified and directed by Engineer- in - Charge. 300 Each
11 11 S&F Modular switch 1 way 16A, 1 module single pole , complete all as specified and directed by Engineer- in - Charge. 369 Each
12 12 S&F Modular socket 16A - 2/3 pin 2 module complete all as specified and directed by Engineer- in - Charge. 369 Each
13 13 S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and directed by Engineer - in - Charge. 327 Each
14 14 S&F Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by Engineer in charge 14 Each
15 15 S&F Modular Bell push 6A 1 module, complete all as specified and directed by Engineer- in - Charge. 14 Each
16 16 S&F Modular Fan step regulator, 120W - 2 module, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engineer- in - Charge. 46 Each
17 17 Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by Engineer in charge. 46 Each
18 18 Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 17 46 Each
19 19 Fixing only serviceable light fittings any type as obtained against item No 2 all as specified and directed by Engineer incharge 90 Each
20 20 S&F Stout Mini LED 20/18 Surface /Suspended and wall mounted LED batten, CRCA housing provided for efficient heat dissipation with polycarbonate diffuser & built-In electronic driver having THD<10%., P.F greater than 0.9, input voltage range from 90 Volts to 280Volts making all connection using 1.5sqmm copper conductor multistranded PVC insulated 2 core flexible cable with from ceiling rose to fitting complete all as specified and as directed by Engineer in charge. Make : Havells Cat No: STOUTMINI1200BS20WLED865SPCW or Wipro or CG or equalvent in same specification as mentioned in description of any mes approved make as sample approved by Accepting Officer. 292 Each
21 21 S&F Endura Linear neo10/12 watt surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. input voltage AC 220V-240V, 50 Hz with colour tempetrature 6500K complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceiling rose to fitting complete all as per directed by Engr-in-charge. Havells: Cat No: ENDURALINEARNEOBS10WLED865SPCWH/ or Wipro or CG or equalvent in same specification as mentioned in description of any mes approved make as sample approved by Accepting Officer. 35 Each
22 22 S&F LED CLEAN ROOM bottom opening SS frame IP65, dust free & zero maintenance, luminaire for hygenic facilitie 2x2 LED, colour temperature -5700K, CRI >80,PF >0.95, THD < 10 36 watt long life & photobiologically safe LED’s high performance electronic driver ensures zero maintenance Instant light with low running temperatures, making all connection using 1.5sqmm copper conductor multistranded PVC insulated 2 core flexible cable, neccessary arrangement fixing to GI wire at roof and hanging light with GI wire suitable size from roof to fitting with nut, bolts etc. complete all as specified and as directed by Engineer in charge.Make Make : Havells Cat No: BOCR2X2R36WLED857SPCSSGEN or Wipro or CG or equalvent in same specification as mentioned in description of any mes approved make as sample approved by Accepting Officer. 57 Each
23 23 S&F LED CLEAN ROOM bottom opening SS frame IP65, dust free & zero maintenance, luminaire for hygenic facilitie 2x2 LED, colour temperature -5700K, System Lumens- 5280lm, CRI >80,PF >0.95, THD < 10, input voltage 140-270 V, 60 watt long life & photobiologically safe LED’s high performance electronic driver ensures zero maintenance Instant light with low running temperatures, making all connection using 1.5sqmm copper conductor multistranded PVC insulated 2 core flexible cable, neccessary arrangement fixing to GI wire at roof and hanging light with GI wire suitable size from roof to fitting with nut, bolts etc. complete all as specified and as directed by Engineer in charge Make : Havells Cat No: BOCR2X2R60WLED857SPCSSGEN or Wipro or CG or equalvent in same specification as mentioned in description of any mes approved make as sample approved by Accepting Officer. 50 Each
24 24 Supply and fixing LED street light fitting 25W new generation energy saving & environmental friendly long life versatile pressure die-cost aluminium IP66 with acrylic with heat resistant toughened glass, corrosion resislant complete making all connection with MCB SPN alongwith MCB Box enclosura, GI tubing light grade 25mm dia lenght 1.2 mtr, clamp, bolts, nuts and washers complete with testing all as specified and directed by Engineer in charge 16 Each
25 25 M & L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion, making good the disturbed surfaces to match with existing specifications complete all as specified and directed by Engineer in charge . Note: (i) Two runs of 6sqmm and one run of 6 sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM. (ii) Necessary wall cutting/chasing for conduit/fixture will be done through electrical cutter machine only. 678 RM
26 26 All as per item No. 25 herein before but with 10 sqmm pvc copper conductor cable through pvc conduit ISI marked with 10 sqmm copper conductor cable as earth contiunity conductor complete all as specified and directed by Engineer in charge. 959 RM
27 27 Supply and fix in repair sheet metal enclosure VTPN 6 way 415 volt 250 Amp rated bus bar double door type,mechanical impact strength IK09 with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB, IP-54 protection grade fixed flush to wall complete including cable connections should be provide with necessary reducer lugs complete all as directed by Engr-in-Charge. 3 Each
28 28 Supply and fix in repair sheet metal enclosure VTPN 4 way 415 volt 250 Amp rated bus bar double door type,mechanical impact strength IK09 with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB, IP-54 protection grade fixed flush to wall complete including cable connections should be provide with necessary reducer lugs complete all as directed by Engr-in-Charge. 5 Each
29 29 S & F and connecting with necessary copper lugs DPX3 thermal magnetic type MCCB 4 pole,250 Amp, 415 volt, with breaking capacity 25 KA including making necessary arrangement all as specified and directed by the Engr-in-Charge. 8 Each
30 30 S & F and connecting with necessary copper lugs DPX3 thermal magnetic type MCCB 4 pole,200 Amp, 415 volt, with breaking capacity 25 KA including making necessary arrangement all as specified and directed by the Engr-in-Charge. 1 Each
31 31 Supply and fix in repair sheet metal enclosure double door single pole and neutral 240 Volts for DB's when MCBs to be used 8 way with 200 amp rated bus bar with IP-54 protection complete all as specified and directed by Engineer in charge. 14 Each
32 32 All as per srl item No 31 above but 12 way, complete all as specified and directed by the Engr-in-Charge. 20 Each
33 33 S&F connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domesitc loads incl necessary copper lugs etc all as specified and as directed by Engineer incharge. 34 Each
34 34 Supply and fixing, connection and testing 'C' series MCB SP6-32 Amps complete all as specified and directed by Engineer in charge. 284 Each
35 35 Supply and fixing connection and testing 'C' series MCB SP 40 Amps complete all as specified and directed by Engineer in charge. 60 Each
36 36 S&F Plug and socket DBs, single pole and neutral enclosure with a two pin earth plug and socket with one single DP20 Amps, 240 volts MCB complete all as specified and directed by Engineer in charge. 34 Each
37 37 S&F in repair PVC conduit medium grade 20 mm dia ISI marked with all accessories such as Tees, elbows, junction boxes etc complete all as per the direction of Engr-in-Charge. 85 RM
38 38 M&L for earthing in repair complete with copper plate earth electrode 60cmX60cmx3.15 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5m below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal, common salt, 20x 3 mm copper strip, 20mm GI medium grade watering pipe 15mm bore light grade protection pipe 5 Mtr length with wire mesh and funnel PCC pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, angle iron frame and RCC cover and earth work complete all as shown in electrical plate No.3 of SSR -2009(Part-1) complete all as specified and directed by Engineer in charge. 16 Each
39 39 M&L for disconnecting all Electrical connection from MCB DB TPN/Wall Mounted Panel Box for reconnecting the same with providing proper Copper Bottle Lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire complete all as specified and directed by Engineer in charge.\nNote : Replacement Burnt out MCBs of any type/size may be measured and paidseparately under relavent Items 6 Each
40 40 M&L for Cutting of hard standing n.exc 45 Cm defth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing all as directed . 60 RM
41 41 Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase all as specified and directed by Engineer in charge. Note : Cutting of Wall /Floor shall be measured and paid separately. 7 Each Job
42 42 M&L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer in charge. 93 RM
Disclaimer :