Military Engineer Services-MES has published Debulleting Of Fire Range And Repairs To Fencing , Culverts , Boundary Wall , Security Wall , Foot Path , Drains , Retaining Wall , Gates , Periodical Services Etc At Af Stn Bidar. Submission Date for this Tender is 16-11-2020. Footpath Work Tenders in GE (AF) BIDAR Karnataka. Bidders can get complete Tender details and download the document.
Name of Work : DEBULLETING OF FIRE RANGE AND REPAIRS TO FENCING, CULVERTS, BOUNDARY WALL, SECURITY WALL, FOOT PATH, DRAINS, RETAINING WALL, GATES, PERIODICAL SERVICES ETC AT AF STN BIDAR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | M&L applying one coat of white wash on old decorated surfaces of walls including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed. | 42000 | Sqm | |
2 | 2 | M&L preparation of old painted steel and iron surfaces of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. | 305 | Sqm | |
3 | 3 | M&L preparation of old decorated surfaces of walls including brooming down or steel wire brushing/scrapping down smoke soot mould, moss and efflorescent salts, trading oil and greasy spots and applying one coat of cement based paint complete all as specified and as directed. | 3500 | Sqm | |
4 | 4 | Removal of existing treatment complete and M&L applying two coats of cement base paint over a coat of alkali resistant primer on surfaces of walls including preparation etc complete all as specified and directed. | 50 | Sqm | |
5 | 5 | Taking down cement plaster on brick or stone walls etc., including raking out joints, hacking for key, scrubing down with water etc., complete all as specified and directed. | 150 | Sqm | |
6 | 6 | M&L Rendering 15mm thick in Cement mortar 1:4 with WPC on stone masonry surfaces or surfaces other than fair face of brick work, and finished even and smooth with out using extra cement complete all as specified and directed.\nNote :- Water proofing compound shall be measured and paid separately. | 558 | Sqm | |
7 | 7 | Supply only intergral water proofing compound. | 200 | Kg | |
8 | 8 | M&L applying three coats of white wash on new plastered surfaces of wall including preparation complete all as specified and directed. | 25 | Sqm | |
9 | 9 | M&L preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and as directed. | 135 | Sqm | |
10 | 10 | Dismantling wrought iron or mild steel work of any description not otherwise provided for fencing posts etc, complete all as specified and as directed. | 35 | Per Qtl | |
11 | 11 | S&F MS angle iron as in fencing including cutting tops to shape as required, drilling holes,notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including necessary drilling, bolting or riveting,etc, and similar work conforming to Fe-290 Gde, \nE-165 complete all as specified and directed. | 3000 | Kg | |
12 | 12 | M&L preparation of new steel surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. | 375 | Sqm | |
13 | 13 | S&F in repairs punched tape concertina coil of dia 450mm fixed to angle iron brackets with necessary accessories like straining wires, fixing clips etc complete all as specified and directed. | 500 | RM | |
14 | 14 | Dismantling of RCC posts, struts of any section for security/cattle fencing including taking out embedded portion and making good disturbed ground, posts embedded in natural ground complete all as specified and directed. | 100 | RM | |
15 | 15 | All as per item No. 14 above but posts embedded in cement concrete -ditto-. | 500 | RM | |
16 | 16 | M&L Mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. | 867 | Kg | |
17 | 17 | S&F in repairs Galvanised 2 strand steel barbed wire 2.24mm dia barbed wire with 2mm dia barbs at 75mm spacing and type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed. | 60 | 100 Rm | |
18 | 18 | Taking down and re-fixing of galvanized 2 strand steel barbed wire fixing to any type of standard rails straining bolts including securing or tyting and crossing with the provision of galvanized MS wire staples or steel pins etccomplete all as specified and directed. | 8 | 100 Rm | |
19 | 19 | M&L Providing plain cement concrete type D2,1:4:8 (using 40 mm graded aggregate) as in foundations or mass concrete complete all as specified and directed. | 6.08 | Cum | |
20 | 20 | Dismantling of chain link fencing of any type complete all as specified and directed. | 2500 | Sqm | |
21 | 21 | S&F MS flat iron fillets (for securing chain link fencing) including necessary drilling, bolting or riveting etc., complete all as specified and directed. | 1500 | Kg | |
22 | 22 | S & F Mild steel bolts, machine made ,with hexagonal or Square head one end and screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 15 cm and n,exc 22.5 cm long, dia of shank 11 to 15mm | 225 | Kg | |
23 | 23 | Supply only chain link MS galvanized fencing of any size or type complete all as specified and directed. | 5375 | Kg | |
24 | 24 | Fixing only Chain link fencing including lines wire, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed. | 2500 | Sqm | |
25 | 25 | M&L Rendering 15mm thick cement plaster in CM 1:6 on wall surfaces of brick work or cement surfaces is to be finished even and smooth without using extra cement complete all as specified and directed. | 110 | Sqm | |
26 | 26 | S&F framed work in doors or gates of angle section with gusset plate, braces etc drilled for fixing of steel sheeting including hooks etc conforming to Fe-410-0 complete all as specified and directed. | 500 | Kg | |
27 | 27 | Welding in repairs n.exec 25mm in length and thickness of metal to be welded n.exec 6mm complete all as specified and directed. | 37 | Each | |
28 | 28 | Taking down of sand (fine aggregate) and saw dust from small arms range/firing butt. The serviceable materials of sand and raw dust are segregated by sieving and stacking a side for re-use complete all as specified and as directed. \n | 360 | Cum | |
29 | 29 | M&L fine aggregate (approved sand) and saw dust mixed at (3:1) ratio (three part of sand and one part of saw dust) and spread, levelled, compacted to a true and inclined finished surface, complete all as specified and directed. | 160 | Cum | |
30 | 30 | All as per item No-29 above but except sand & saw dust -ditto-.\nNote:- (i) Sand and Saw dust are obtained from sl item No-28.\n(ii) Mixing ratiao shall be 3:1 (3 part sand and 1 part saw dust). | 200 | Cum | |
31 | 31 | Removal of sand and saw dust obtained from ser item No 28 above to a distance n.exc 50mm and depositing where directed of a level n.exc 1.5m above the starting point complete all as specified and as directed. | 160 | Cum | |
32 | 32 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thick (unreinforced) below or above ground level complete all as specified and directed. | 70 | Cum | |
33 | 33 | M&L Plain Cement concrete, 100mm thick, type D- 2, 1:4:8 (using 40mm graded stone aggregate) for sub base of floors complete all as specified and as directed. | 700 | Sqm | |
34 | 34 | M&L in repairs Machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with gray cement and pigment etc, complete all as specified and as directed. | 700 | Sqm | |
35 | 35 | M&L sand (cushioning) filling under floors including watering and consolidation complete all as specified and as directed. | 28 | Cum | |
36 | 36 | Demolition of brickwork or stone or PCC block masonry, built in cement mortar or cement lime mortar complete all as specified and directed. | 108 | Cum | |
37 | 37 | M&L Precast cement concrete block masonry walling type C1 1:3:6 ( using 20 mm graded stone aggraegate), setting in CM (1:4) with PCC solid blocks exc 10 cm in width complete all as specified and directed. | 100 | Cum | |
38 | 38 | All as per item No.37 above but except PCC blocks -ditto-.\nNote :- PCC solid blocks are obtained from sl item No-36. | 8 | Cum | |
39 | 39 | M& L Plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and including necessary form work complete all as specified and directed. | 12 | Cum | |
40 | 40 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for cover slabs complete all as specified and directed. | 2.5 | Cum | |
41 | 41 | M& L Providing precast reinforced cement concrete 1:2:4, type B1, (using 20mm graded stone aggregate) for cover slab, set in CM 1:6 including necessary form work complete all as specified and directed. | 2.5 | Cum | |
42 | 42 | S&F TMT bars 6mm to 8 mm dia cut to length, bent to shape required including cranking, hooking end and binding with mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed. | 75 | Kg | |
43 | 43 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), complete all as specified and directed. | 344 | Sqm | |
44 | 44 | M&L Chequered Cement concrete tiles of size 20cmx20cmx 25mm thick set, jointed and pointed in neat cement slurry as in floors with white cement & pigment etc including 20mm thick Screed bed or bedding layer in CM 1:4 for laying of floor finishes complete all as specified and directed. | 344 | Sqm | |
45 | 45 | M&L in repairs 450mm dia bore reinforced concrete pipes, class NP2 laid and jointed with collars complete all as specified and directed. | 7.5 | RM | |
46 | 46 | S & F in repairs 75mm PVC (SWR) Pipes Single socketed in any length as in weep holes complete all as specified and as directed. | 31 | RM |