Supply Of Mv Cables , Supply Of Medium Voltage ( 650 / 1100V ) Power And Control Cables . Design , Manufacture , Supply , Testing At Works , Inspection , Packing And Delivery At Site Of The Following 650 / 1100V , Stranded Aluminium / Copper Conductor , Xlpe Insulated , Gi Strip / Wire Armoured , Pvc Inner Sheathed And Frls Pvc Outer Sheathed , Multi-Core Cables , As Per Material Requisition For Medium Voltage ( 650 / 1100V ) Power & Control Cables ( S-17047-4-Emr3510 ) And Cable Data Sheet . This Boq Has To Be Supplied As Per Cable Drum Schedule . Pvc / Rubber End Caps Shall Be Supplied Free Of Cost For Each Drum With A Minimum Of Eight Per Thousand Metre Length . In Addition , End Of The Cables Shall Be Properly Sealed With Caps To Avoid Ingress Of Water During Transportation And Storage . A Tolerance Of +3% Shall Be Permissible For Each Drum . However Overall Tolerance On Each Size Of Cable Shall Be Limited To +2% . No Negative Tolerance Is Acceptable . Bidder / Vendor To Note That Purchaser / Epcm Will Provide Cost For Cable Lengths Mentioned In Boq Only . Cost For Cable Length Of Any Value Of Positive Tolerence Has To Be Considered By Bidder / Vendor . Purchaser / Epcm Will Not Give Additional Cost For Any Value Of Positive Tolerence . Control Cables - , 5C X 1 . 5 Sq . Mm Copper , 8C X 2 . 5 Sq . Mm Copper , Supply Of Medium Voltage ( 650 / 1100V ) Power And Control Cables . Design , Manufacture , Supply , Testing At Works , Inspection , Packing And Delivery At Site Of The Following 650 / 1100V , Stranded Aluminium / Copper Conductor , Xlpe Insulated , Gi Strip / Wire Armoured , Pvc Inner Sheathed And Frls Pvc Outer Sheathed , Multi-Core Cables , As Per Material Requisition For Medium Voltage ( 650 / 1100V ) Power & Control Cables ( S-17047-4-Emr3510 ) And Cable Data Sheet . This Boq Has To Be Supplied As Per Cable Drum Schedule . Pvc / Rubber End Caps Shall Be Supplied Free Of Cost For Each Drum With A Minimum Of Eight Per Thousand Metre Length . In Addition , End Of The Cables Shall Be Properly Sealed With Caps To Avoid Ingress Of Water During Transportation And Storage . A Tolerance Of +3% Shall Be Permissible For Each Drum . However Overall Tolerance On Each Size Of Cable Shall Be Limited To +2% . No Negative Tolerance Is Acceptable . Bidder / Vendor To Note That Purchaser / Epcm Will Provide Cost For Cable Lengths Mentioned In Boq Only . Cost For Cable Length Of Any Value Of Positive Tolerence Has To Be Considered By Bidder / Vendor . Purchaser / Epcm Will Not Give Additional Cost For Any Value Of Positive Tolerence . Power Cables - , 3C X 2 . 5 Sq . Mm Copper , 3C X 4 Sq . Mm Copper , 3C X 6 Sq . Mm Copper , 3C X 10 Sq . Mm Copper , 3C X 25 Sq . Mm Aluminium , 3C X 35 Sq . Mm Aluminium , 3C X 50 Sq . Mm Aluminium , 3C X 70 Sq . Mm Aluminium , 3C X 95 Sq . Mm Aluminium , 3C X 120 Sq . Mm Aluminium , 3C X 185 Sq . Mm Aluminium , 3C X 240 Sq . Mm Aluminium , 3 . 5C X 35 Sq . Mm Aluminium , 3 . 5C X 185 Sq . Mm Aluminium , 3 . 5C X 300 Sq . Mm Aluminium , Supply Of Medium Voltage ( 650 / 1100V ) Power And Control Cables . Design , Manufacture , Supply , Testing At Works , Inspection , Packing And Delivery At Site Of The Following 1100V , Stranded Aluminium / Copper Conductor , Xlpe Insulated , Annealed Copper Tape Screening Over Laid Up Cores , Pvc Inner Sheathed And Frls Pvc Outer Sheathed , Multi-Core Cables , As Per Material Requisition For Medium Voltage ( 650 / 1100V ) Power & Control Cables ( S-17047-4-Emr3510 ) And Cable Data Sheet . This Boq Has To Be Supplied As Per Cable Drum Schedule . Pvc / Rubber End Caps Shall Be Supplied Free Of Cost For Each Drum With A Minimum Of Eight Per Thousand Metre Length . In Addition , End Of The Cables Shall Be Properly Sealed With Caps To Avoid Ingress Of Water During Transportation And Storage . A Tolerance Of +3% Shall Be Permissible For Each Drum . However Overall Tolerance On Each Size Of Cable Shall Be Limited To +2% . No Negative Tolerance Is Acceptable . Bidder / Vendor To Note That Purchaser / Epcm Will Provide Cost For Cable Lengths Mentioned In Boq Only . Cost For Cable Length Of Any Value Of Positive Tolerence Has To Be Considered By Bidder / Vendor . Purchaser / Epcm Will Not Give Additional Cost For Any Value Of Positive Tolerence . Shielded Power Cables - , 3 . 5C X 25 Sq . Mm Aluminium , 3 . 5C X 70 Sq . Mm Aluminium , 3 . 5C X 240 Sq . Mm Aluminium , 4C X 2 . 5 Sq . Mm Copper , 4C X 4 Sq . Mm Copper