Military Engineer Services-MES has published Repair Maintenance Of Geysers And Solar Water Heaters Under Ge West Bareilly. Submission Date for this Tender is 10-11-2020. Solar Heater Tenders in GE WEST BAREILLY Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of work :- Repair / Maint of Geysers and Solar water heaters under GE(W) Bareilly. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down of unserviceable bolt of existing geyser, M&L grouting of new bolt (tee type) at new place and refixing of geyser of any type and any capacity all as speified and directed by Engr in Charge. | 400 | Each | |
2 | 2 | M&L for replacement and re-filling of glass wool as per norms of different type of geysers complete all as specified and directed by the Engr in Charge. | 10 | Kgs | |
3 | 3 | M&L for GI tubing 15 mm dia medium grade including GI fittings fixed to wall and making good to disturbed surfaces of wall including dismantling existing air released valve pipe making proper connection for hot air releasing system complete all as specified, Make-Tata/Jindal/Bansal/Utkrash | 20 | RM | |
4 | 4 | Supply and Fixing in repairs heating element 1.5 KW/2.0 KWngular type as per sample all as directed by the Engr in Charge. | 500 | Each | |
5 | 5 | M&L for replacement of bottom cover in two parts of MS sheets not less than 22 gauge and pre treated in finished in white stove enameled paint as per existing size gauge in the geyser of any capacity/size complete all as specified and directed. | 50 | Each Set | |
6 | 6 | Supply and fixing safety pressure valve with vent to geysers as per latest ISI specification and directed. | 400 | Each | |
7 | 7 | M&L for Painting the outer surface of geyser capacity 25/35/50 ltrs as per original shade with two coats of synthetic enamel paint over a coat of primer by spray gun after scrapping the existing paint ,denting etc. filling depression with putty and refixing the geyser in position including water/electric connection and testing complete all as specified and directed. | 250 | Each | |
8 | 8 | M&L for Brazing/ welding to inner copper tank at leaking spots up to five leakage of geyser of capacity 25/35/50 liters of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed. | 150 | Nos. | |
9 | 9 | S&F assemblly of geyser 25/35/50 ltr.capacity as specified and directed by Engg. In charge. | 200 | Nos. | |
10 | 10 | Supply and Fixing in repairs Indicator lamp with new indicating lamp round/square, rectangular type as required at site, SP 230Volt | 200 | Each | |
11 | 11 | Supply and Fixing in repairs wire three core flexible cable PVC insulated multi stranded copper conductor for geyser of size 40/0.0076, 1100 V grade | 200 | RM | |
12 | 12 | Supply and Fixing in repairs PVC connection flexible heavy grade 45 cm long complete with chromium plated flair nuts with washers at both ends suitable for GI tubing 15 mm bore complete all as specified and directed. | 400 | Each | |
13 | 13 | Supply and Fixing in repairs thermostat 0 to 90 degree, ISI marked, 15 Amps capacity automatic cut off at desired temp of suitable size for Geyser | 400 | Each | |
14 | 14 | Supply and Fixing in repairs Plug top 15 Amps Make Anchor or equivalent | 100 | Each | |
15 | 15 | Repair to flat plate collector type solar water heater of capacity 200 ltr. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/PUF insulation/heating element/ thermostat/cold water storage tank/gate valves/metal clamps and ensure all connection to be leakproof complete all as specified and directed. Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/ heating element/thermostat/cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items\n(ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates | 2 | Each Job | |
16 | 16 | Repair to flat plate collector type solar water heater of capacity 300 ltr. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/ rubber hose/PUF insulation/ heating element/thermostat/cold water storage tank/gate valves/ metal clamps and ensure all connection to be leakproof complete all as specified and directed. Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/ rubber hose/heating element /thermostat/ cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items\n(ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates | 2 | Each Job | |
17 | 17 | Repair to flat plate collector type solar water heater of capacity 500 ltr. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/ rubber hose/PUF insulation/ heating element/thermostat/cold water storage tank/gate valves/metal clamps and ensure all connection to be leakproof complete all as specified and directed. Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose /heating element/thermostat/cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items\n(ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates | 2 | Each Job | |
18 | 18 | Supply and fixing float toughened solar glass (1m × 2m) complete all as specified and directed . | 6 | Each | |
19 | 19 | supply and fixing in replacement 3/8 inch dia copper tubing complete all as specified and directed . | 10 | RM | |
20 | 20 | Supply and fixing gasket of suitable size as per sample complete all as specified and directed . | 10 | Each | |
21 | 21 | Supply and fixing rubber hose pipe of 20mm inner dia and suitable thickness complete all as specified and directed . | 10 | RM | |
22 | 22 | Supply and fixing metal clamp for fixing rubber hose pipe including nut/bolts/washers and ensuring proper leakproof connection complete all as specified and directed . | 10 | Each | |
23 | 23 | Supply and fixing heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as specified and directed . | 35 | Each | |
24 | 24 | Supply and fixing only thermostat for heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as all as specified and directed . | 35 | Each | |
25 | 25 | Supply and fixing Gun metal globe or Gate valves with ironwheel head,screwed both ends for iron pipe of 25/30 mm dia bore including taking out unserviceable valve complete all as specified and directed. | 5 | Each | |
26 | 26 | Supply and fix MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one MCB single pole Amps, volts | 100 | Each | |
27 | 27 | Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes all as directed. | 145 | Per Point | |
28 | 28 | M&L for concealed point wiring for one light/ fan point controlled by one switch with1.5 Sqmm (Nominal area) PVC insulated, unsheathed, stranded copper, conductor cable FRLS (1100Volts grade) drawn in and including PVC conduits of 20 mm dia with all fittings and accessories alongwith PVC insulated cable with copper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 1. 2mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with screws,cap and washers incl. making good the disturbed surfaces complete. Make of Cable: Polycab/Finolex/Havells,ISI Marked \n\n | 25 | Point | |
29 | 29 | All as per item no.2 here in before but for socket outlet 3/5 pin 5 amp. on the same board. | 5 | Point | |
30 | 30 | All as per item No 02 here-in-before but for switch socket combination 5 Amps 3/5 Pin point on independent board\nMAKE OF CABLES : Polycab/Finolex/Havells,ISI Marked\n | 15 | Point | |
31 | 31 | M&L for concealed point wiring with 2.5 Sqmm (Nominal area) PVC insulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher size with all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with solid copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20mm sunk pressed steel terminal box suitably flushed to wall with 3mm thick Hylum sheet cover fixed with screws & cup washers incl. making good complete.\nMAKE OF CABLES : Polycab/Finolex/Havells,ISI Marked\n | 100 | Point | |
32 | 32 | Supply and Fixing in repairs P/switch flush type 5/6 Amp SP one way. | 50 | Each | |
33 | 33 | Supply and Fixing in repairs P/switch flush type 15/16 Amp SP one way. | 100 | Each | |
34 | 34 | Supply and Fixing in repairs ceiling rose 2/3 terminals | 25 | Each | |
35 | 35 | Supply and Fixing in repairs socket outlet ,3/5 pin 5 amp flush type | 25 | Each | |
36 | 36 | Supply and Fixing in repairs socket outlet 2 in one, 3/5 pin 5 and 15 Amp flush type | 100 | Each | |
37 | 37 | Supply and Fixing in repairs MCB SPN 20 to 32 Amps 240 volts.10kA Make:- Legrand/ Havells/Standard | 50 | Each | |
38 | 38 | Supply and Fixing in repairs MCB SP 6 to 32 Amps 240 volts, 10 kA. Make:- Legrand/ Havells/Standard | 250 | Each | |
39 | 39 | Supply and Fixing in repairs MCCB TPN 100 Amps, 415V, 16kA ,Thermal Magnetic Release | 20 | Each | |
40 | 40 | Taking down unserviceable existing sub main wiring with aluminium conductor stranded cable of any size single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed. . | 500 | RM | |
41 | 41 | M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 2.5 Sqmm connected to common earth dolly and drawing into rigid PVC conduit with lock pattern incl. making good the disturbed surface complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).\nMAKE OF CABLES : Polycab/Finolex/Havells,ISI Marked\n | 400 | RM | |
42 | 42 | M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).\nMAKE OF CABLES : Polycab/Finolex/Havells,ISI Marked | 100 | RM | |
43 | 43 | S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 12 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge. | 15 | Each | |
44 | 44 | Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 ways Make Make Legrand or equivalent make of HPL Moeller/L&T Hagger/Havells complete all as specified and directed. | 10 | Each | |
45 | 45 | Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways Make Make Legrand or equivalent make of HPL Moeller/L&T Hagger/Havells complete all as specified and directed. | 20 | Each | |
46 | 46 | Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways Make Make Legrand or equivalent make of HPL Moeller/L&T Hagger/Havells complete all as specified and directed. | 10 | Each | |
47 | 47 | S&F LED retrofit tube with PVC extruded battern 20watt 4 feet White colour Code No LTDC30120WLED/WD of Make C&S , Crompton greaves, Philips, Havells including dismentiling and taking down any type of FTL/LED complete all as specified and directed. | 1000 | Each | |
48 | 48 | Supply,fixing and testing single phase electric meter of 2 wire , whole current meter and direct reading type of capacity 6KV, 50 Hz alongwith cover box complete all as specified and directed by Engr In Charge. | 200 | Each | |
49 | 49 | Supply,fixing and testing three phase electric meter of 4 wire , whole current meter and direct reading type of capacity 16KV, 50 Hz alongwith cover box complete all as specified and directed by Engr In Charge. | 10 | Each | |
50 | 50 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3of SSR 2009 including testing after completion. | 75 | Each | |
51 | 51 | Notes :- (i) For Serial No 01 to 50: The Contractor has to complete the work assigned for above items with in 72 hours failing in which recovery at the rate 100 Rs. per day per comlaint.\n (ii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint cell and get them signed from user after completing the job and submit to E/M complaint cell. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy