Military Engineer Services-MES has published Repairing Of Internal Wiring , Mcb With Connected Items At Asc , Mh , Mdc And Minor Units Under Ge Ramgarh Repairing Of Internal Wiring Mcb With Connected Items At Asc Mh Mdc And Minor Units Under Ge Ramgarh. Submission Date for this Tender is 10-11-2020. Electrification Work Tenders in RAMGARH CANTT Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

25781718
Repairing Of Internal Wiring , Mcb With Connected Items At Asc , Mh , Mdc And Minor Units Under Ge Ramgarh Repairing Of Internal Wiring Mcb With Connected Items At Asc Mh Mdc And Minor Units Under Ge Ramgarh
Open Tender
Indian
Jharkhand
RAMGARH CANTT
10-11-2020

Tender Details

Repairing Of Internal Wiring , Mcb With Connected Items At Asc , Mh , Mdc And Minor Units Under Ge Ramgarh Repairing Of Internal Wiring Mcb With Connected Items At Asc Mh Mdc And Minor Units Under Ge Ramgarh

Key Value

Document Fees
INR 500 /-
EMD
INR 27960.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIRING OF INTERNAL WIRING, MCB WITH CONNECTED ITEMS AT ASC, MH, MDC AND CERTAIN UNITS UNDER GE RAMGARH CANTT
Sl. No. Description of Items Item Code / Make Quantity/ Nos of Units Units
1 1 Taking down carefully any type of point wiring (light, fan, socket bell or power) complete with all fitting such as batten, switch, ceiling rose, pendent, regulator, socket and brackets switch fuse etc removing materials from site and making good disturbed surfaces of walls, floors etc to match the existing surface all as directed . 1 545 Per Point
2 2 M & L for point wiring for one light/ fan point/call bell controlled by one switch with 1100 volt grade PVC insulated FRLS 1.5 Sq mm multi stranded copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia & sunken anodized pressed sunken boxes made out of not less than 1.0 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches etc complete all as specified and directed. 2 270 Per Point
3 3 All as per item No 2 above but 1.5 Sq mm for 5 Amp socket outlet on same board with 1.5 Sq mm earth wire complete. 3 50 Per Point
4 4 All as per item No 2 above but 1.5 Sq mm for 5 Amp switch socket on independent board with 1.5 Sq mm earth wire complete. 4 100 Per Point
5 5 All as per item No 2 above but 2.5 Sq mm for 15 Amp switch socket on independent board with 2.5 Sq mm earth wire complete. 5 125 Per Point
6 6 Supply and fix ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified. 6 250 Each
7 7 Supply and fix Socket outlet 2 in 1, 5 pin 5 Amp flush type universal 230 volt complete all as specified. 7 100 Each
8 8 S&F Switch piano, flush type single pole, one way 05 Amp flush type universal 230 volt complete all as specified. 8 370 Each
9 9 S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type universal 230 volt complete all as specified. 9 125 Each
10 10 S&F Switch piano, flush type single pole, one way 15 Amp flush type universal 230 volt complete all as specified. 10 125 Each
11 11 S & F angle holder complete all as specified and as directed. 11 300 Each
12 12 S & F LED Lamp 9 Watt complete all as specified and as directed. 12 300 Each
13 13 S&F Fan regulator electronic type 5 step, 230 volt complete all as specified. 13 100 Each
14 14 S&F call bell Ding dong, AC 230 volts, single pole complete all as specified. 14 20 Each
15 15 S&F bell push flush type 5 amp AC 230 volts, single pole complete all as specified. 15 20 Each
16 16 S&F LED tube light batten suitable for LED T-8 lamps (Cat part No- DMLN1T8-16) pre-wired with LED tube rod 16 W ( Cat part No- LTT8-16) with extruded aluminium body PC diffuser and inbuilt driver of Crompton Greaves or equivalent model of Philips/ Wipro/GE including electrical connection from ceiling rose to light fitting by PVC flexible wire 23/.0076 mm size including earth connection complete. 16 80 Each
17 17 S&F LED bulk head fitting 15 W with LED lamp , powder coated with die cast housing Code : SSK-BH-9W of syska LED or equivalent model of Philips/ Bajaj including electrical connection from ceiling rose to light fitting by PVC flexible wire 23/.0076 mm size including earth connection complete. 17 5 Each
18 18 M & L Sub main wiring two single core 4.0 Sqmm PVC insulated FRLS multistanderd copper conductor cable and one run of 4.0 Sqmm PVC insulated unsheathed FRLS multistanderd copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia in ncluding taking down of existing conduit or batten complete and making good disturbed surface wall complete all as specified and as directed. \nNote : - Not : 2 runs of 4 Sqmm cable and 1 run of earth wire shall be measured as one unit length. 18 250 RM
19 19 S&F sheet metal enclosures for DBs single pole & neutral 4 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed area of wall complete all as specified & as directed. 19 20 Each
20 20 S&F sheet metal enclosures for DBs single pole & neutral 8 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed area of wall complete all as specified & as directed. 20 12 Each
21 21 S&F in repair sheet metal enclosures for DBs single pole & neutral 12 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed area of wall complete all as specified & as directed. 21 4 Each
22 22 S&F in repair MCB single pole 6 to 32 Amp 240 V, ‘B’ Series, 10 KA, complete all as specified and as directed. 22 240 Each
23 23 S&F in repair MCB SPN, 20 to 40A 240V, ‘B’ Series, 10 KA complete all as specified and as directed. 23 70 Each
24 24 Taking down old serviceable tube light fitting of any type from wall/ceiling and refixing the same in existing / other position after defect rectification.\nNote : Spares including fixing for repair will be include in the repairing cost. 24 500 Each
25 25 S&F LED tube rod 18 Watt with electrical connection as required including testing complete 25 365 Each
26 26 Supply 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranderd conductor 16 Sq mm including testing complete all as specified and directed. 26 350 Each
27 27 M&L ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. \nNote : Earth test result should not less than one ohm. 27 4 Each
28 28 S&F 3 M surface mounted with SP MCB 25 Amp & plug top with Indicator (Cat part No. PU3M-BT, Make North West) for AC protection complete all as specified 28 5 Each
29 29 S&F metering panel suitable for opreation on 03 phase and netural,415 V, 50 Hz AC system (04 meters) including testing and refixing of meters, complete all as specified and as directed. 29 6 Each