Military Engineer Services-MES has published Maintenance Repair Replacement Of Internal Electrification Wiring Dbs Sub Main Wiring Bldg Earthing E/M Fitting And Fixtures And Repair/Servicing Of Ceiling Fans Pedestal Fans Exhaust Fans Geysers At Rhq ( E ) Dhq5 Cgsd Bmu Besant Nagar Nandanam Saf Gam. Submission Date for this Tender is 30-10-2020. Electrification Work Tenders in Garrison Engineer (I)(CG) Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.
Name of Work: Maint/Repair/Replacement of internal electrification, wiring, DB's, sub main wiring, bldg earthing, E/M fitting and fixtures and Repair/Servicing of Ceiling Fans, Pedestal Fans, Exhaust Fans, Geysers at RHQ (E), DHQ-5, CGSD, BMU, Besant Nagar, Nandanam, SAF Games Village, Mogappair and Emerald Flats under GE (I) (CG) Chennai. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down carefully copper/aluminium point wiring (light,fan, socket or power) including fixture and fittings complete including removing material from site and taken as credit and making good the disturbed surface of wall/floor etc to match with the existing surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001114 | 55 | PER POINT |
2 | 2 | Taking down carefully submain wiring with aluminum conductor cable 4/6/10/16 Sqmm with PVC conduit concealed/ on surfacecomplete including removing material from site and taken as credit and making good the disturbed surface of wall/floor etc to match with the existing surfaces complete all as specified and as directed. | BI01010001010000000000000515BI0100001116 | 150 | RM |
3 | 3 | Material and labour for Point wiring with 1.5 sqmm (Nominal area) unsheathed FRLS multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non metallic rigid PVC conduit of 20 mm dia concealed / PVC casing/capping along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof and including 2mm thick terminal boxes MS sheet flush mounted with 3mm thick laminated hylem sheet for mountling switches, socket, fan regulators etc complete for one light point or one fan point controlled by one switch complete all as specified and as directed.Note:\nMake of PVC copper conductor cable:- Finlex/Poly cab/ Asian.\nMake of PVC conduit /casing/capping : Avon plast/ Kon seal / Garware. | 10 | PER POINT | |
4 | 4 | All as per item No.4 here in before but one light point controlled by two way switches. | 5 | PER POINT | |
5 | 5 | All as per item No.4 here in before but One 3 pin socket outlet 5 amps , independent . | 20 | PER POINT | |
6 | 6 | All as per item No.4 here in before but One 3 pin socket outlet 5 amps ,on the same board with other switches. | 5 | PER POINT | |
7 | 7 | All as per item No.4 here in before but One bell /buzzer point controlled by one push button on the same board with other switches,independent . | BI01010001010000000000000515BI0100001118 | 5 | PER POINT |
8 | 8 | Material and labour for Point wiring with 4 Sqmm single core FRLS PVC sheathed copper conductor cable, drawn into and including non metallic rigid PVC conduit of 20 mm dia concealed / PVC casing/capping along with 4.0 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof and including 2mm thick terminal boxes MS sheet flush mounted with 3mm thick laminated hylem sheet for mountling switches, socket, fan regulators etc complete fo rOne 3 pin socket outlet 15 amps , independent .complete all as specified and as directed.Note:\nMake of PVC copper conductor cable:- Finlex/Poly cab/ Asian.\nMake of PVC conduit : Avon plast/ Kon seal / Garware. | 10 | PER POINT | |
9 | 9 | Removing unserviceable wiring from conduit on surface of wall/batten/casing/ceiling and Material & Labour for 2x1.5 sqmm (Nominal area) FRLS unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into existing non metalic rigid PVC conduit of 20 mm dia complete all as specified and asdirected. Note:-\nMake of PVC copper conductor cable:- Finlex/Poly cab/ Asian.. | 100 | RM | |
10 | 10 | Material and labour for Sub main wiring with two run single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 4.00 Sq mm multi stranded copper conductor cable as earth continuity conductor drawn into existing non metallic PVC conduit 25 mm dia and conduct accessories. PVC casing concealed/surface of wall/ceiling complete all as specified and as directed.\n Notes: \n \n (i) Two different color wires shall be used for phase and neutral . \n (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles .\n (iii) Three run of 4.0 Sqmm cable will be measured as one unit.\n (iv)Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian. | 50 | RM | |
11 | 11 | Material and labour for Sub main wiring with four run of single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and two run of 4.00 Sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 25 mm dia concealed wiring including conduit accessories complete all as specified and as directed.\n Notes: \n (i) The disturbed surfaces shall be made good with existing surface including finishes as applicale. \n (i) Two different color wires shall be used for phase and neutral . \n (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles .\n (iv) Six run of 4.0 Sqmm cable, and one run of PVC conduit will be measured as one unit.\n Make of cable:- Finlex/Poly cab/ Asian. Make of PVC conduit : Avon plast/ Kon seal / Garware. | 15 | RM | |
12 | 12 | Material and labour for Sub main wiring with four run of single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 6.00 Sq mm multi stranded copper conductor cable as earth continuity conductor drawn into existing non metallic PVC conduit 32 mm dia and conduct accessories. PVC casing concealed/surface of wall/ceiling complete all as specified and as directed.\n Notes: \n \n (i) Two different color wires shall be used for phase and neutral . \n (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles .\n (iii) Five run of 6.0 Sqmm cable will be measured as one unit.\n (iv)Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian. | 50 | RM | |
13 | 13 | Material and labour for Sub main wiring with four run of single core 10 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 10.00 Sq mm multi stranded copper conductor cable as earth continuity conductor drawn into existing non metallic PVC conduit 32 mm dia and conduct accessories. PVC casing concealed/surface of wall/ceiling complete all as specified and as directed.\n Notes: \n \n (i) Two different color wires shall be used for phase and neutral . \n (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles .\n (iii) Five run of 10.0 Sqmm cable will be measured as one unit.\n (iv)Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian. | 15 | RM | |
14 | 14 | Material and labour for Sub main wiring with four run of single core 16 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade and one run of 16.00 Sq mm multi stranded copper conductor cable as earth continuity conductor drawn into existing non metallic PVC conduit 32 mm dia and conduct accessories. PVC casing concealed/surface of wall/ceiling complete all as specified and as directed.\n Notes: \n \n (i) Two different color wires shall be used for phase and neutral . \n (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles .\n (iii) Five run of 16.0 Sqmm cable will be measured as one unit.\n (iv)Make of PVC copper conductor cable:- Finlex/Poly cab/ Asian. | 20 | RM | |
15 | 15 | Supply and fix socket flush type 5 in one ,5Amp/240 Volts including taking down old unserviceable socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB | 25 | EACH | |
16 | 16 | Supply and fix socket flush type 5pin, 16 Amp/240 Volts including taking down old unserviceable switches and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB | 10 | EACH | |
17 | 17 | Supply and fix Switch piano flush type single pole one way 5 A 240 Volts including taking down old unserviceable switches and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB | 40 | EACH | |
18 | 18 | Supply and fix in repair Switch socket combination 2 in 1, 3/5 pin, 5 Amps Flush type 240 Volts including taking down old unserviceable switche socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB | 30 | EACH | |
19 | 19 | Supply and fix in repair Switch socket combination 2 in 1, 3/5 pin, 16 Amps Flush type 240 Volts including taking down old unserviceable switche socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB | 50 | EACH | |
20 | 20 | Supply and fix in repair Modular switch 6 Amps one way flush type 240v AC,including taking down old unserviceable modular switch and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB | 15 | EACH | |
21 | 21 | Supply and fix in repair Modular switch 6 Amps two way flush type, 240v AC, including taking down old unserviceable modular switch and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB | 5 | EACH | |
22 | 22 | Supply and fix in repair Modular socket 3 pin 6 Amps flush type 240v AC, including taking down old unserviceable modular socket and taken as credit complete all as specified and directed. Make: Legrand/Anchor/ABB | 15 | EACH | |
23 | 23 | Supply and fix in repair Modular socket 3 pin 16 Amps flush type , 240v AC, including taking down old unserviceable modular socket and taken as credit complete all as specified and directed.Make: Legrand/Anchor/ABB | 25 | EACH | |
24 | 24 | Supply and fix Stepped type electronic fan regulator flush type , 240V on the existing phenolic laminated sheet including taking down old unserviceable one and taken as credit complete all as specified and directed \nMake :Legrand/Anchor/Rider | 120 | EACH | |
25 | 25 | Supply and fix in repair Modular type electronic ceiling fan regulator, 2 module, 240 V including taking down old unserviceable one and taken as credit complete all as specified and directed Make: Legrand/Anchor/Rider. | 30 | EACH | |
26 | 26 | Supply and fix in repair ceiling rose 3 terminals PVC / Polycarbonate, isolated body complete all as specified and as directed.\nMake : Baja/Anchor/HPL | 20 | EACH | |
27 | 27 | Supply and fix in repair Lamp holder PVC / Polycarbonate, isolated body including taking down old unserviceable lamp holder and taken as credit complete all as specified and directed. | 30 | EACH | |
28 | 28 | Supply and fix in repair Call bell ding dong, AC, 240 V, single pole, including taking down old unserviceable calling bell and as credit complete all as specified and as directed.\n Make:- Bajaj/Philips/HPL | 10 | EACH | |
29 | 29 | Supply and fix in repair modular white cover plate with frame 2- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed..\n Make:- Legrand/Anchor/ABB | 5 | EACH | |
30 | 30 | Supply and fix in repair modular white cover plate with frame 3- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed..\n Make:- Legrand/Anchor/ABB | 5 | EACH | |
31 | 31 | Supply and fix in repair modular white cover plate with frame 4- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed..\n Make:- Legrand/Anchor/ABB | 5 | EACH | |
32 | 32 | Supply and fix in repair modular white cover plate with frame 6- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed..\n Make:- Legrand/Anchor/ABB | 4 | EACH | |
33 | 33 | Supply and fix in repair modular white cover plate with frame 8- Module including taking down old unserviceable cover plate and taken as credit complete all as specified and as directed..\n Make:- Legrand/Anchor/ABB | 4 | EACH | |
34 | 34 | Supply and fix in repair modular metal flush box for 1/2 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. \n Make:- Legrand/Anchor/ABB | 2 | EACH | |
35 | 35 | Supply and fix in repair modular metal flush box for 3 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. \n Make:- Legrand/Anchor/ABB | 6 | EACH | |
36 | 36 | Supply and fix in repair modular metal flush box for 4 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. \n Make:- Legrand/Anchor/ABB | 4 | EACH | |
37 | 37 | Supply and fix in repair modular metal flush box for 6 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. \n Make:- Legrand/Anchor/ABB | 4 | EACH | |
38 | 38 | Supply and fix in repair modular metal flush box for 8 Module including taking down old unserviceable metal box and taken as credit complete all specified and as directed.. \n Make:- Legrand/Anchor/ABB | 4 | EACH | |
39 | 39 | Dismantling from walls, corroded metal box and supply and fix flush to wall 2mm thick MS sheet fabricated terminals box of size 4" X 4"including hylem sheet, plastering the sides to match with the existing surface complete all specified and as directed.. | 4 | EACH | |
40 | 40 | All as per item No 40 herein before but box of size 6" x 4" | 2 | EACH | |
41 | 41 | All as per item No 40 herein before but box of size 8" x 6" | 2 | EACH | |
42 | 42 | All as per item No 40 herein before but box of size 12" x 8" | 2 | EACH | |
43 | 43 | Supply and fix sheet metal enclosure powder coated single door for Board distribution with 200 Amps rated bus bar, MCB DB SPN 2 way , 240Volts including , Disconnecting electric connections, dismantling from position unserviceable DBs and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen | 20 | EACH | |
44 | 44 | Supply and fix sheet metal enclosure powder coated single door for Board distribution with 200 Amps rated bus bar, MCB DB SPN 4 way , 240 Volts including , Disconnecting electric connections, dismantling from position unserviceable DBs and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen | 10 | EACH | |
45 | 45 | Supply and fix sheet metal enclosure powder coated single door for Board distribution with 200 Amps rated bus bar, MCB DB SPN 8 way , 240 Volts including , Disconnecting electric connections, dismantling from position unserviceable DBs and taken as credit complete all as specified and as directed. Make:Indo Asian/L&T/Siemen | 4 | EACH | |
46 | 46 | All as per item No 45 herein before but MCB DB TPN 4 way, 415 Volts Make:Indo Asian/L&T/Siemen | 2 | EACH | |
47 | 47 | All as per item No 45 herein before but MCB DB TPN 8 way, 415 Volts Make:Indo Asian/L&T/Siemen | 1 | EACH | |
48 | 48 | All as per item No 45 herein before but MCB DB TPN 12 way, 415 Volts Make:Indo Asian/L&T/Siemen | 1 | EACH | |
49 | 49 | Supply and fix sheet steel enclosure with socket plug top and MCBs complete single pole and neutral enclosure with 2- Pin and earth plug and socket complete with single pole MCB 25 Amp capacity(DBOX COMBO DP) including fixing in walls duly embedded complete all specified as directed. Make:Indo Asian/L&T/Siemen | 10 | EACH | |
50 | 50 | Supply and fix MCB 5-32A single pole 240 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directedMake:- Make:Indo Asian/L&T/Siemen | 44 | EACH | |
51 | 51 | Supply and fix MCB 5-32A single pole and neutral, 240 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directedMake:- Make:Indo Asian/L&T/Siemen | 30 | EACH | |
52 | 52 | Supply and fix MCB TP 5-32 Amps, 415 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directedMake:- Make:Indo Asian/L&T/Siemen | 2 | EACH | |
53 | 53 | Supply and fix MCB TPN 5-32 Amps, 240 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directedMake:- Make:Indo Asian/L&T/Siemen | 2 | EACH | |
54 | 54 | Supply and fix MCB TP 63Amps, 10 KA, 415 Volts of rupturing capacity 10 KA including removing of old unserviceable MCB and taken as credit complete all as specified and as directedMake:- Make:Indo Asian/L&T/Siemen | 2 | EACH | |
55 | 55 | Supply and fix MCB TPN 63-100Amps, 10 KA, 415 Volts including removing of old unserceable MCB complete all as specified and directed.Make:- C&S/HPL/Legrand/Siemen/Schneider/ABB | 2 | EACH | |
56 | 56 | Taking down unserviceable Electric meter of any type and capacity from meter box and removing and deposit to MES store complete all as specified and as directed. | 16 | EACH | |
57 | 57 | Supply and fix microprocessor based single phase electric tamper proof energy menter of rating 5 to 30 Amp, 230 V with optical communication port, conforming to IS: 13779 completed all as specified and as directed.Make:L&T/Secure/ | 10 | EACH | |
58 | 58 | Supply and fix microprocessor based single phase electric tamper proof energy menter of rating 40 to 60 Amp, 230 V with optical communication port, conforming to IS: 13779 completed all as specified and as directed.Make:L&T/Secure | 5 | EACH | |
59 | 59 | Supply and fix microprocessor based single phase electric tamper proof energy menter of rating 200 Amp, 415 V with optical communication port, conforming to IS: 13779 completed all as specified and as directed.Make:L&T/Secure | 1 | EACH | |
60 | 60 | Taking down carefully unserviceable ceiling fans of any size from its position, dismantling blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle, reassembling after replacement of defective parts including replacement of 3 core 0.75 Sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging in its position properly complete all as specified and as directed. \nNotes :- Spare parts required for repair of defective parts will be measured and paid separatly under relevent items here in after. | 400 | EACH | |
61 | 61 | Description all as per Sl item No 61 here in before but exhaust fan of any size | 200 | EACH | |
62 | 62 | Description all as per Sl item No 61 here in before but wall mounted fan of any size. | 15 | EACH | |
63 | 63 | Supply only ball bearing suitable for ceiling fan, exhaust fan, pedestal fan of same size as per existing defective one complete all as specified and as directed.(Make : Tata/SKF/NBC) | 250 | EACH | |
64 | 64 | Supply only bush bearing suitable for ceiling fan, exhaust fan and pedestal fan complete all as specified and as directed.(Make : Tata/SKF/NBC) | 200 | EACH | |
65 | 65 | Supply only condenser 2.5 MFD complete all as specified and as directed.(Make : usha/Keltron/Uptran) | 200 | EACH | |
66 | 66 | Supply only condenser 4 MFD complete all as specified and as directed.(Make : usha/Keltron/Uptran) | 30 | EACH | |
67 | 67 | Supply only condenser holder PVC or metal for fixing capacitor/condenser complete all as specified and as directed. | 10 | EACH | |
68 | 68 | Supply only shackle accessories complete with rubber bush, bolt, nut, split pin complete all as specified and as directed. | 40 | EACH | |
69 | 69 | Cleaning and preparing the surfaces of ceiling fan of any size, removing the grease, carbon dust over the fan and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and as directed. | 100 | EACH | |
70 | 70 | Cleaning and preparing the surfaces of exhaust fan of any size, removing the grease, carbon dust over the fan and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and as directed. | 20 | EACH | |
71 | 71 | Cleaning and preparing the surfaces of pedastal fan of any size, removing the grease, carbon dust over the fan and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and as directed. | 4 | EACH | |
72 | 72 | Rewinding the stator complete with super enamelled bare copper conductor with the same size and number of turns as per the old one, insulating, varnishing and pre heating for ceiling fan of 1200mm/1400mm sweep complete all as specified and as directed. | 225 | EACH | |
73 | 73 | Description all as per Sl No 72 herein before but Exhaust fan upto 300mm sweep. | 30 | EACH | |
74 | 74 | Description all as per Sl No 73 herein before but Exhaust fan above 300mm upto 450mm sweep. | 5 | EACH | |
75 | 75 | Description all as per Sl No 74 herein before but Wall mounted fan upto 300mm sweep. | 5 | EACH | |
76 | 76 | Description all as per Sl No 75 herein before but Pedestal fan upto 400mm sweep. | 2 | EACH | |
77 | 77 | Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and as directed.\nNotes :- Spares required for replacement will be measured and paid seperately. | 5 | EACH | |
78 | 78 | Supply only new heating element of capactity 1.5KW with rubber gasket complete all as specified and as directed.Make:Racold/Venus/Bajaj | 5 | EACH | |
79 | 79 | Supply only new heating element of capactity 2 KW with rubber gasket complete all as specified and as directed..Make:Racold/Venus/Bajaj | 5 | EACH | |
80 | 80 | Supply only thermostat suitable for storage type water heater complete all as specified and as directed. Make:H-GURU/PIE BIG | 5 | EACH | |
81 | 81 | Supply only Pressure release valve 15mm dia suitable for geyser complete all as specified and as directed.Make:KIRLOSKAR/L&T/LEADER | 2 | EACH | |
82 | 82 | Supply only Air release valve 15mm dia suitable for geyser complete all as specified and as directed.Make:KIRLOSKER/L&T/LEADER | 2 | EACH | |
83 | 83 | Supply only 3 core 2.5 Sqmm copper conductor PVC cable suitable for geysers of any size complete all as specified and as directed.(Make : Finolex/Poly cab /Plaza) | 50 | RM | |
84 | 84 | Supply only Non return valve 15mm dia suitable for geyser complete all as specified and as directed.Make:KIRLOSKER/L&T/LEADER | 5 | EACH | |
85 | 85 | Supply and fix 3 pin plug top suitable for metal socket of capacity 25 Amps complete all as specified and as directed.(Make :Indo asian/ legrand/L&T) | 5 | EACH | |
86 | 86 | Material and labour for Preparing external surfaces of water heater, cleaning and painting with one coat of synthetic enamel paint of white colour of approved make with brush and writing MES No complete all as specified and as directed. | 5 | EACH | |
87 | 87 | Supply only Aparatus plate assembly suitable to fix thermostat, heating elements of geyser with nuts etc complete all as specified and as directed. | 2 | EACH | |
88 | 88 | Supply only Fusible plug for geyser complete all as specified and as directed.(Make :Indo asian/ legrand/L&T) | 2 | EACH | |
89 | 89 | Removing the copper tank from the geyser of any size , brazing to arrest the leakage, reassembling and refixing complete all as specified and as directed. | 2 | EACH JOB | |
90 | 90 | Supply and fix Bottom inspection chamber cover suitable for 25 Litres capacity geyser of any make/model complete all as specified and as directed. | 2 | EACH | |
91 | 91 | Supply and fix Indication lamp suitable for geyser in round/rectangular shape complete all as specified and as directed. | 3 | EACH | |
92 | 92 | Supply and fix 5 Star rating ceiling fan 1200mm sweep suitable to work on single phase AC 230 Volts 50 Hz complete including connecting electrically to ceiling rose or connector block using PVC insulated sheathed 3 core cable 0.75sqmm flexible copper conductor and removing of old unserviceable fan and deposited at MES store for BER complete all as specified and as directed\nMake : Crompton/ Orient /Almonard/Bajaj | 20 | EACH | |
93 | 93 | Supply, fix and test water heater storage type (Geyser) of capacity 25 litres capacity, 5 Star rating, 2 KW heating element, ergoniminally styled plastic body. Unique temparature indicator dial, adjustable thermostat, magnesium anode for extra protection form corrison and leakage, glass line inner tank, PUF insulation, product warranty 2 years, Tank warranty 7 years, heating element warranty 3 years rust & shock proof autocut facility complete fixed at location as decided by Engr-in- charge including one non return valve & one safety valve inbuilt of geyser fire retardant ISI mark supply cord with plug top and electrically operated suitable for 230 volts and cold water line 01 No and anchor bolts complete all as specified and directed. Note : Anchor bolt shall be grouted with hammer drill only. Make of Geyser : Bajaj /Racold/Venus | 4 | EACH | |
94 | 94 | Supply and Fix Exhaust fan AC single phase 230/240V of size 300 mm sweep with louver ,Heavy Duty including old unserviceable exhaust fan to be deposited at MES store for BER complete all as specified and directed. (Make: Havells/CG/Almondard) | 10 | EACH | |
95 | 95 | Removing unserviceable existing geyser tank replacement of new tank of capacity 25 Ltrs made out of stainless steel complete all as specified and directed | 2 | EACH | |
96 | 96 | Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth strip of 32x6mm by means of bolts,nuts check nuts and washers of GI all as shown in electric plate No 3 connecting to earthing test point including necssary exacavation in any earth strata , PCC chambers in PCC 1:3:6 type C1, RCC 1:2:4 type B1 cover slab 50mm thick with 8 mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle watering pipe of GI 20 mm dia medium grade, funnels, lug and charcol,salt etc all as applicable and as per plate No 3 of SSR part 1 connecting test point and testing on completion complete and all as specifed and as directed . Notes:-The rates quoted is inclusive of galvanised earth strip of 32x6mm conductor upto a length of 7.5m from the earth pit. | 2 | EACH SET | |
97 | 97 | Supply and fix 3 pin plug top suitable for metal socket of capacity 15 Amps complete all as specified and as directed.(Make :Indo asian/ legrand/L&T) | 5 | EACH | |
98 | 98 | Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 32x6 mm galvanised iron strip complete and all as specifed and as directed . | 10 | RM | |
99 | 99 | Supply and fix Switch piano flush type two way 5 A 240 Volts including taking down old unserviceable switches and taken as credit complete all as specified and as directed.Make: Legrand/Anchor/ABB | 5 | EACH | |
100 | 100 | Supply Only LED light fitting 4 feet white, 20W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and as directed.\nMake:- Philps Cat Part No. BN021C LED20 S PSU CW GR S2 In case the make mentioned above is not available in market then equivalent price and specification in M/S Wipro /M/S Bajaj | 300 | EACH | |
101 | 101 | Supply Only light fitting 2 feet white, 10W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and as directed. \n Make:- Philps Cat Part No. BN 021 LED10S- 6500 PSU GR S1 In case the make mentioned above is not available in market then equivalent price and specification in M/S Wipro /M/S Bajaj | 150 | EACH | |
102 | 102 | Supply Only 9W LED Mirror Light with aluminium body and IP 20 Protection ,AC 140-265 V\n Make : Luker CAT part No.: LMR9 In case the make mentioned above is not available in market then equivalent price and specification in M/S Wipro /M/S Philips | 10 | EACH | |
103 | 103 | Supply Only High eficiency 2x2 recess LED Flat panel 34W recessed mounting LED luminaire suitable for amtrong/grid ceiling with super bright LED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Including taking down old U/S fittings complete all as specified and as directed \nMake: Philps model No: RC380B LED 34 S-4000 L 60 W 60 PSU OD S 1 or equivalent price, specification and cat part no in M/S WIPRO | 10 | EACH | |
104 | 104 | Supply Only LED down light fitting 20W, 'Sleek' Round shaped surface mounted downlight cool wight Color Temperature 6000K. Cat Part No. BGSLO sleek surface 6W WH RD of Bajaj or any other equivalent make of Philips / CG including connecting up complete including dismanting old unserviceable one and taken as credit complete all as specified and as directed. | 17 | EACH | |
105 | 105 | Supply Only LED Bulb 9 Watt make bajaj/crompton including taking unserviceabl old fitting etc | 30 | EACH | |
106 | 106 | NOTE: The supply only item Nos: 100 to 105 mentioned in BOQ shall be executed as per monthly demand/repair raised from the CG unit concerned. The contractor will supply as per demand raised by the user to MES. The Department will issue Receipt Vocher for the above item supplied by the Contractor. Original Paid Voucher with GST Paid for the purchase of above items shall be produced to GE`s office before claiming the above items in RAR by the contractor. The fixing of above items will be executed through DL held with AGE E/M office through Baby Indent/Job card daily and Register in this regard shall be maintained by JE/AGE duly signed by User Periodically. |