}

Repair / Maintenance Of Electric And Water Supply Instln At Baramulla Under Ge 969 Ews, Baramulla-Jammu And Kashmir

Military Engineer Services-MES has published Repair / Maintenance Of Electric And Water Supply Instln At Baramulla Under Ge 969 Ews. Submission Date for this Tender is 09-11-2020. Electrical Maintenance Tenders in Baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25780239
Repair / Maintenance Of Electric And Water Supply Instln At Baramulla Under Ge 969 Ews
National Competitive Bid
Indian
Jammu And Kashmir
Baramulla
09-11-2020

Tender Details

Repair / Maintenance Of Electric And Water Supply Instln At Baramulla Under Ge 969 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIR / MAINT OF ELECTRIC AND WATER SUPPLY INSTLN AT BARAMULLA UNDER GE 969 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Surface excavation not exe 30 cm deep and average 15 cm deep and getting out in hard/ dense soil / hard core including removing the excavated grass /weeds/hard cement concrete / stone etc. and leveling neatly the excavated area for substation yards / providing PCC path etc . Note:- The rate shall be deemed to be included the cost of removing the grass, weeds, debris, excess soil etc to a distance not less than 50m and keeping the excavated surface clean and levelled Complete all as specified and directed by Eng-In-Charge. item1 2600 SQUARE METRE
2 2 Supply and spreading fly ash around the outdoor transformer to a avrg. depth of 15 cm Complete all as specified and directed by Eng-In-Charge. item2 170 CUBIC METRE
3 3 M&L for stone aggregate of size not exeeding 40 mm deposited spread and levelled in layers not exeeding 15 cm to a true surface of broken stones for transformer and pole structure area. Complete all as specified and directed by Eng-In-Charge. item3 170 CUBIC METRE
4 4 S&F in repairs danger notice plate 1.6 mm thick MS sheet , vitreous enamelled , white with letters, figures and conventional skull & bones in signal red colour and fixed with MS clamps, bolts ,nuts of approved size for HT, 25x20 cm size including taking out the old outlived one. Complete all as specified and directed by Eng-In-Charge. item4 20 Each
5 5 S&F in repair - MCCB 4 pole, 415 volts, adjustable type, 160 Amps, 36KA including disconnecting and removing existing with necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model, Complete all as specified and directed by Eng-In-Charge. item5 3 Each
6 6 All as per item No.5 above but MCCB 4pole, 415 Volts, Adjustable type ,of capacity 250 Amps, Breaking capacity 36 KA Complete all as specified and directed by Eng-In-Charge. item6 4 Each
7 7 All as per item No.5 above but MCCB 4pole, 415 Volts, Adjustable type ,of capacity 100 Amps, Breaking capacity 25 KA Complete all as specified and directed by Eng-In-Charge. item7 8 Each
8 8 S&F in repairs straight through jointing kit suitable for LT UG cable of size upto 50 sqmm 3½ core , including testing Complete all as specified and directed by Eng-In-Charge. item8 4 Each
9 9 S&F in repairs straight through jointing kit suitable for LT UG cable of size 70 sqmm to 150 sqmm 3½ core including testing Complete all as specified and directed by Eng-In-Charge. item9 4 Each
10 10 Servicing to LT panels/Feeder pillar boxes comprising MCCBs/change over switches metering eqpt etc. as incomming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checking the seviceability of individual items, identification of the defective parts replacing the wornout fastners, insulators, rubber door beadings, gakets etc,Complete all as specified and directed by Eng-In-Charge.\nNote :- Unserviceable parts replaced if any shall be measured & paid seperately under respective items of Sch 'A'. item10 8 Each
11 11 M&L carrying out following repairs to LT panels/Feeder pillar boxes. Complete all as specified and directed by Eng-In-Charge. :- \na) Removing the existing hinges by cutting and supply and fixing of new hinges all as per existing size. item11 5 Each
12 12 b) Painting of LT panel board/feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc. Complete all as specified and directed by Eng-In-Charge. item12 6 EACH JOB
13 13 c) Rewiring the LT cubical type panel by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,. etc after taking out the old unserviceable wiring. Complete all as specified and directed by Eng-In-Charge. item13 6 EACH JOB
14 14 d) Supply only LED indication Lamps for R,Y,B Phase. Complete all as specified and directed by Eng-In-Charge. Note:- Material required only for item No.10 of Sch 'A'.\n item14 7 Each
15 15 e) Supply only Volt meter 0-500 volts with Selector Switch. Complete all as specified and directed by Eng-In-Charge. Note:- Material required only for item No.10 of Sch 'A'.\n\n item15 5 Each
16 16 f) Supply only Ammemeter digital type of rating 100A to 300A with selector switch. Complete all as specified and directed by Eng-In-Charge. Note:- Material required only for item No.10 of Sch 'A'.\n item16 4 Each
17 17 g) Supply only digital Power Factor meter any range 1A/5A and 110/230V with built in transducer Accuracy class ±20 Complete all as specified and directed by Eng-In-Charge. Note:- Material required only for item No.10 of Sch 'A'.\n item17 4 Each
18 18 h) Supply only Indoor resin cast ring type low tension current transformer 50/5A to 75/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992. Complete all as specified and directed by Eng-In-Charge. Note:- Material required only for item No.10 of Sch 'A'.\n item18 6 Each
19 19 j) Supply only Indoor resin cast ring type low tension current transformer 100/5A to 300/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992. Complete all as specified and directed by Eng-In-Charge. Note:- Material required only for item No.10 of Sch 'A'.\n item19 3 Each
20 20 S&F in replacement steel chequered plate of thickness 6mm for cable duct cover in MRS substation Bldg. Complete all as specified and directed by Eng-In-Charge. item20 60 KILOGRAM
21 21 M&L for painting to existing steel tubular LT Poles, 9/11m long including cross arms, channels angle iron support, bracings, clamps etc. with two coats of alumium paint superior quality of approved make on surfaces exposd to view and making 30 cm wide strips (total 5 nos) with white and black/red paint alternaly on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers , incls bold letters with black paint after painting Complete all as specified and directed by Eng-In-Charge. item21 950 Each
22 22 S&F in replacement, sheet metal enclosure distribution box for TPN MCB'S 4 way 415 volts with 200 Amps rated bus bar double door complete including connecting up, making good distrubed surface. Complete all as specified and directed by Eng-In-Charge. (Note :(a)Quoted rate shall be inclusive of refixing of serviceable MCB. item22 15 EACH
23 23 All as per item No 22 above but DB 12 way SPN with 200 Amps rated bus bar 240 Volts. item23 8 EACH
24 24 All as per item No.22 above but DB 8 way SPN with 200 Amps rated bus bar , 240 volts item24 32 EACH
25 25 All as per item No 22 above but DB 4 way SPN with 200 Amps rated bus bar , 240 volts item25 10 EACH
26 26 S & F in repairs MCB Single pole, 240 volts 5 to 30 Amps 10 KA rupturing capacity, C series Complete all as specified and directed by Eng-In-Charge. item26 300 EACH
27 27 S & F in repairs MCB Single pole & neutral 240 volts 32 to 40 Amps, 10KA rupturing capacity, C series Complete all as specified and directed by Eng-In-Charge. item27 55 EACH
28 28 S & F in repairs MCB Single pole & neutral 240 volts 63 Amps, 10KA rupturing capacity, C series Complete all as specified and directed by Eng-In-Charge. item28 20 EACH
29 29 S & F in repairs MCB triple pole & neutral 415 volts 32 Amps 10KA rupturing capacity, C series Complete all as specified and directed by Eng-In-Charge. item29 5 EACH
30 30 S & F in repairs MCB triple pole & neutral 415 volts 63 Amps 10KA rupturing capacity, C series Complete all as specified and directed by Eng-In-Charge. item30 4 EACH
31 31 S & F in repairs MCB triple pole & neutral 415 volts 100 Amps 10 KA rupturing capacity, C series. Complete all as specified and directed by Eng-In-Charge. item31 5 EACH
32 32 S & F in repairs MCB triple pole , 415 volts 40 Amps 10KA rupturing capacity, C series Complete all as specified and directed by Eng-In-Charge. item32 8 EACH
33 33 S & F in repairs MCB triple pole , 415 volts 63 Amps 10 KA rupturing capacity, C series. Complete all as specified and directed by Eng-In-Charge. item33 5 EACH
34 34 S & F in repairs MCCB triple pole & neutral 415 volts 100 Amps 16 KA rupturing capacity, C series. Complete all as specified and directed by Eng-In-Charge. item34 4 EACH
35 35 S & F in repairs MCCB triple pole & neutral 415 volts 63 Amps 16 KA rupturing capacity, C series. Complete all as specified and directed by Eng-In-Charge. item35 4 EACH
36 36 S & F in repairs MCCB triple pole & neutral 415 volts 125 Amps 16 KA rupturing capacity, C series. Complete all as specified and directed by Eng-In-Charge. item36 4 EACH
37 37 M&L for earthing with galvanised iron earth plate electrode 600mm x600mmx 6mm thick burried directly in ground (Eart pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.00mm dia connected to earth plate electrode by means of bolts,nuts,check nutsand washers, earth wire protected with and including 15 mm bore light grade ISI marked GI pipe upto 7.5 meters long aii as shown in electrical plate no 5 of MES schedule part-1,with and includingPCC 1:2:4 type B1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtrwith handle andangle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked,GI fannel with GI mesh,filling with mixture of commen salt and charcoal,necessary excavation, refilling, removing away spoiland earth work in any type of soil, including test point, testing and commissioning. Complete all as specified and directed by Eng-In-Charge.. item37 19 EACH
38 38 M&L for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sqmm drawn through and including suitable size of non-metallic PVC rigid conduit with 4sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up including taking down old U/S wiring. Complete all as specified and directed by Eng-In-Charge. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length. Complete all as specified and directed by Eng-In-Charge. item38 100 RM
39 39 M&L for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit with 6 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length. Complete all as specified and directed by Eng-In-Charge. item39 100 RM
40 40 M&L for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit with 10 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length. Complete all as specified and directed by Eng-In-Charge. item40 115 RM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail