Consultancy For Provision Of Deficient Married Accommodation Type V , Type-Ii And Family Welfare Centre At Dahanu , Under Ge ( I ) Cg Daman, GOA-Goa

Military Engineer Services-MES has published Consultancy For Provision Of Deficient Married Accommodation Type V , Type-Ii And Family Welfare Centre At Dahanu , Under Ge ( I ) Cg Daman. Submission Date for this Tender is 03-11-2020. Consultancy Service Tenders in GOA Goa. Bidders can get complete Tender details and download the document.




Tender Notice

25780096
Consultancy For Provision Of Deficient Married Accommodation Type V , Type-Ii And Family Welfare Centre At Dahanu , Under Ge ( I ) Cg Daman
Open Tender
Indian
Goa
GOA
03-11-2020

Tender Details

Consultancy For Provision Of Deficient Married Accommodation Type V , Type-Ii And Family Welfare Centre At Dahanu , Under Ge ( I ) Cg Daman

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Provision of Deficient married accommodation Type V, Type-II and Family Welfare Centre at Dahanu,Under GE (I) CG Daman.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 (1) Consultancy for Architectural designing services for the buildings of Sr No 1 to 6 of Appx'A' with following requirements:\n(a) Preperation of conceptual Arch drgs, three proposals with relevant details like plans, elevations, section etc based on data attached as per approved Board proceedings/Approximate estimate Part-I & II and local Architectural Norms/Bye laws. The conceptual drawings shall be submitted in duplicate for approval of Director (Arch) of HQ CE (CG) Goa.\n(b) After approval of conceptual drawings, final Architecutral drawings shall be prepared including Schedule of finishes, Internal water supply, internal electrification; drawings of fire fighting, fitting fixtures, pipe etc; incorporating required changes/modifications as suggested by this HQ and submit the same. The final drawings shall be got approved from Director (Arch), Schedule of finishes and internal water supply scheme from Dir(Plg) and E/M drawings and other related documents from SO-I (E/M) of HQ CE (CG) Goa. Final Architectural and other drawings and documents to be submitted to this HQ in hard copy (on Tracing sheets) duly signed by an Authorized Architect with CA Number as follows:\ni. Architecutural working drawings like all the floor plans, elevations and sections are to be in 1:100 scale.\nii. Toilet, Kitchen and Stair details will be in 1:25 Scale.\niii. Other necessary details will be in convinient scale\niv. Site plan be prepared be at 1:1000 or suitable scale.\nConsultant shall confirm to the following general conditions:\n1. The consultant should visit the site/location and prepare line plan/site plan as per the site shown to him.\n2. The consultant must provide the most modern Arch desings with excellent elevaions of the buildings and also to suggest materials for interior/exterior design by using modern materials. item1 1 Job
2 1.01 3. The Structural drawings will be prepared after the drawings are vetted and approved by E-6 section.\n4. The specification & Arch practices/procudures followed by MES shall be kept in mind while preparing the and minor deviation are permitted with consent of Director (Arch) of HQ CE(CG) Goa.\n5. Non observance of these conditons may make your Order invalid and unacceptable.\n6. The consultant shall use the data and other information supplied by the client solely for the purpose o performing and carrying out his obligation under this consultancy agreement and shall not disclose the same to any other person, except to the extent required in performance of the work of project through other agency and shall maintain utmost secrecy.\n7. The consultant shall employ only Indian Nationals as his representative/agent, servant and workman and verify their antecedents and loyality before employing them for the works. He shall ensure that no person of doubtful antecedetns and nationality is in any way assocaited with the works.\n8. The consultant shall not without the consent in writing of the client, publish any article or photograph relating to the project.\n9. The design of the building shall be based on the guidelines given in the Zonal specifications (Currently of CE (Navy) Mumbai available E2(D)/E2(Plg) section of this HQ. The Architectural Desing of the buildings should be such that it complies with minimum 3 star GRIHA rating.\n10. Typical drqwings, available with this office may be referred to by the consultant for preparation of his final drawings, if he desires to do so.\n11. Before quoting , consultant shall visit the site and keeping in view the site conditions, the buidings will be designed.\n12. It is intended to to conclude a lumpsum contract for the work, hence Architecural drawings for all buildings inlcuding services and drawings details (i.e inclusive of all relevant details) are required for final completion of the work.
3 1.02 (2) Consultancy Service for STR Design for the buildings of Sr No 1 to 6 of Appx'A' with following requirements:\n(a) The consultant shall provide the STAAD file, Auto CAD drawings in soft copy. Design folder and drawings duly vetted by IIT/NIT/IISc/Govt Engineering College shall be submitted along with soft copies.\n(b)The consultancy shall submit detailed structural design and drawing based on approved design folder to the client for checking. Rep of consultant/designer will be available during checking for necessary clarification /explanation to the client at the appointed date and time. The modification as suggested by the client shall be incorporated and final approved drawing shall be submitted.\n3. All structural drawings shall be prepared as per standard Structural norms and notations etc as followed by client. Analysis and design of structures shall be as per latest revisions of IS-456 2000,IS 1893 2016 and complying with IS 13920 2016 for ductile detailing of reinforcement.\nThe following structural parameters/ details shall be adopted for design:-\n(a) Location of structural : Dahanu\n(b) Type of construction : RCC frame Construction\n(c) Type of concrete : M-30 Concrete.\n(d) Type of steel : Fe-500D Grade\n(e) Safe bearing capacity of soil : As per soil test report\n(f) Super structure : RCC framed \n(g) Analysis & Design : STAAD Pro connect edition version\n(h) Sesismic zone and importance factor : As per seismic Zone of location\n(j) Exposure condition : Severe\n(k) Basic wind speed : As per location \n(l) Fire resistance rating : 1.5 Hours.\n4. The column and location shown in architectural drawings are tentive only and can be changed as per structural requirements. However, the layout plan of rooms and their sizes will remain the same:
4 1.03 5. Documents to be made available to consultant by the department and all the documents are to be returned to the department along with the completion of job order:- \n(a) Revelant extract of BP's if applicable.\n(b) Copy of site plan in suitable scale/contour plan/level sheet as applicable\n(c) Copy of Adm Approval\n(d) Copy Architectural drawings.\n(e) Copy of SBC report.\n(f) Other revelant details as applicable.\n6. The following requirement shall be met with while preparation of structural drawings:-\n(a) The consultant shall be developing complete structural designs and drawings confirming to latest version of revelant BIS codes. The analysis & design shall be carried out using latest versions of design software STAAD Pro connect edition version 22.03.00.28.\n(b) The design concept and plans shall be got approved for a very building/structure from the client before commercement of design. The computer print of structural layout plan must show the member number. Clarification shall be obtained immediately in case of any need.\n(c) The design folder(s) and computer prinout along with CDs shall be submitted in original duly signed by the consultant to be client.\n(d) The structural drawings shall be drawn to a scale sufficient for clear interpretation by executives.\n(e) Every sketch shall be given a serial number so that it can be uniquely referred to along with sheet No e.g " Section of Beam PB (Drawing No 5) Sheet No 8-9" etc, Reference number shall be taken by the consultant from client.\n(f) Schedule of beams, slabs, column and footing shall be given in the table form with sketch of each type.\n\n\n\n\n\n \n\n
5 1.04 (g) The consultant must familiar himself with the general format of structural drawings followed in the office of the MES and prepare his drawings accordingly.\n(h) The structural drawings should give foundation plan floor plan, roof plan, details of portal. Details of joints, connection details of welding etc if any.\n(j) Detailing of reinforcement bars given exhaustively and clearly so as to be totally unambiguous for executives.\n(k) Design of floor of all types and pavements shall also be given.\n\n7. Consultant shall submit to the client the documents as described \nbelow:\n(a) SUBMISSION OF INITIAL DOCUMENTS\nConsultant shall submit the following documents within three weeks from the date of issue of job order:-\n(i) Initial Structural drawings - 02 sets (A1 size)\n(ii) Initial Design calculation - 01 Folder (Draft CD)\n\n(b)SUBMISSION OF FINAL DOCUMENTS\nConsultant shall submit the following documents within six weeks from the date of issue of job Order duly vetted from designated institute viz IIT/NIT/IIS/Govt Engineering Collage duly signed by authorized signatory on behalf the institute and not from a professor/individual in his personal capacity.\n(i) Final Design folder incl STAAD file, Auto CAD- 01 Folder & CD\nDrawings hard copy as well as soft copy in a CD\n(ii) Original Tracing of all drawings prepared as directed-01 Set (A1 size), 05 Set( A1size) by the client & white sheet.\n\n\n\n\n(c)The document submitted by the consultant shall be scrutinized by the client and any observations raised and clarifications sought by the client shall be replied/ clarified by the consultant to entire satisfaction of the client within three days of communication from the client. The consultant shall also attend the office of the Chief Engineer (CG) Goa, if so called for personal discussion and clarification without any extra cost to the client.
6 1.05 (c)The document submitted by the consultant shall be scrutinized by the client and any observations raised and clarifications sought by the client shall be replied/ clarified by the consultant to entire satisfaction of the client within three days of communication from the client. The consultant shall also attend the office of the Chief Engineer (CG) Goa, if so called for personal discussion and clarification without any extra cost to the client.\n\n8. Liability clause for consultant : Liability for the following aspects shall be part of this quotation as per E2 Wks (Design) sub Directorate, Engineer-in-Chief’s Brach Integrated HQ of ministry of Defense (Army), New Delhi letter No: 93348/MISC/Consult/687/E2 Des 3 dated 03 Jul 2011 & A/00157/23-I/Pol/E2W(PPC) dt 02 Jun 2017.\na. The overall responsibility of drawings, design and BoQ, Yardstick lies on Consultant and may be called upon for mid term review of design during execution of work due to site requirement without additional cost.\nb. The consultant alongwith third party vetting also repsonsible for soundness of designs,drawings, adherence to NBC norms, Standing orders and regulations and IS code etc.\nc. The Third Party vetting are also laible and answerable for any design deficiency detected during desing life of building and may be called upon to address such issue if any.\nd. Faulty Design: Consultant to be held responsible for any structural failure/ building distress caused due to faulty design. In event of defective design noticed during execution consultant will be charges liquidity damage at the rate 10% of the cost of deviation order necessitated due to revision of drawings. However in case of minus deviation no liquidity damage will be recovered from consultant.\n\n
7 1.06 e.Delay: Consultant will be held accountable for delays in providing the final design Consultant will be held accountable for delays in providing the final design Consultant will also be held responsible for delays due to inaccurate design and subsequent redesign. Compensation at the rate of Rs 10,000/- per week of delay will be levied on the consultant.\n\n9. GENERAL CONDITION FOR STRUCTURAL DESIGN AND PREPARATION OF STRUCTURAL DRAWINGS\n(a) If the consultancy services by the stipulated date is expected to be delayed due to any cause beyond his control, it shall be brought to the notice of this HQ immediately on the happening of the event causing delay in the completion of services, given notice thereof in writing to the accepting officer under intimation to the consignee who after consideration of circumstance causing delay in the services may reasonable extension of time for the completion.\n(b) If at any time after placing the job order, the client decides to postpone or abandon the project, the client shall given seven days notice in writing to the consultancy after placing the job order to termination the job order. If the project or any part thereof is postponed, the client may in lieu of terminate the job order for the time being. If the client does not require the consultant to resume performance of this services in respect of any postponed work within 07 days from the date of suspension of carrying out of his services, such work shall be considered to have been abandoned and this job order shall be deemed to be terminated.\n(c)The consultant shall be eligible for payment of proportionate fees for the portion of consultancy service already rendered as assessed by the client. The client decision in this regard shall be final and binding. The other compensation whatsoever shall not be paid.
8 1.07 (d)If the consultant commits any breach of any provision of job order or initial documents submitted are found not satisfactory, the client shall be entitled cancel the job order.\nAfter placement of job order, the consultant has to complete the work within 45 days which comprise submitting of initial document as per Para 8(a) (b)&(c) to the department including vetting and approval of client.\n\n(10) Consultancy Service for preperation of the following for the subject work:\n(i) Preperation and submission of Bill of quantity (BoQ), Yardstick building wise as per Adm Approval & as per MES pattern. Rates (Qty:- 744.50 Sqm)\n(ii) Preperation of draft tender documents for building portion as per MES policies and IAFW 2249. Rates (Qty:-744.50 Sqm)\n(iii) Preperation of Market rate analysis for all BoQ items as per amended and finalized tender. Rates (Qty:-744.50 Sqm)\n\nNote :\n(i) Copy of BPs available with HQ CE (CG) Goa.\n(ii) Copy of Soil test report will be provided by HQ CE (CG) Goa.
9 1.08 APPX "A"\nDetails of Building and Plinth Area\n\nDescription of Building Plinth area in SQM\n1. Construction of block of Type-V Md Accn in permanent specifications : [Qty:- 168.5 Sqm]\n2. Construction of block of servant Qtr in S/S construction for type V Md accn in permanent specification : [Qty:- 25.00 Sqm]\n3. Construction of block of garage for car for type V md accn in permanent specification : [Qty:- 56.00 Sqm]\n4. Construction of 02 blocks of type-II Md accn (5 qtrs in each block with 01 qtrs in GF) in G+2 configuration \nArea of each block = 700/2 = [Qty:- 350.00 Sqm]\n5. Construction of stilt parking in permanent specification for type-II Md accn block.\nArea of Each Block = 90/2 = [Qty:- 45.00 Sqm]\n6. Construction of block of family centre in S/S construction : [Qty:-100.00 Sqm]\n Total = 744.50 Sqm\n\n7. Underground sump 20000 Ltrs - Job 1\n