Revival Of Paknamuhan Ii L . I . Project Under Khairput Block Of Malkangiri District, Koraput-Odisha

Orissa Lift Irrigation Corporation Limited has published Revival Of Paknamuhan Ii L . I . Project Under Khairput Block Of Malkangiri District. Submission Date for this Tender is 03-11-2020. Lift Irrigation Tenders in Koraput Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

25778175
Revival Of Paknamuhan Ii L . I . Project Under Khairput Block Of Malkangiri District
Open Tender
Indian
Odisha
Koraput
03-11-2020

Tender Details

Revival Of Paknamuhan Ii L . I . Project Under Khairput Block Of Malkangiri District

Key Value

Document Fees
INR 6000 /-
EMD
INR 11981.0 /-
Tender Value
INR 11.98 Lakhs /-

BOQ Items

Name of Work: TENDER SCHEDULE FOR CONSTRUCTION OF HEAD WORK, DISTRIBUTION SYSTEM & POWER SUPPLY FOR REVIVAL OF PAKNAMUHAN - II L.I.PROJECT UNDER KHAIRPUT BLOCK OF MALKANGIRI DISTRICT
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Earth work excavation in foundation in hard soil with 50 mtr initial lead 1.5 m initial lift including rough dressing and breaking clods to 2 cm to 7 cm and laying in layers not exceeding 0.3 m in depth as per direction of Engineer-in-charge 750.071 cum
2 2 Filling foundation and plinth with sand watered and rammed as per direction of Engineer-in-charge. 39.0985 Cum
3 3 Cement concrete ( 1:4:8) with 4 cm size h.g metal as per direction of engineer-in-charge. 2.1985 Cum
4 4 Cement concrete ( 1:2:4) with 12 mm size h.g Chips as per direction of engineer-in-charge. 3.147 Cum
5 5 Rigid and smooth centering and shuttering for RCC work including false work and dismentalling them after casting including cost of materials complete in Column beams,Roof slab,Plinth Bend 31.903 Sqm
6 6 Supplying, fitting and placing oncoated HYSD(TISCON) bar reinforcement complete as per drawing and technical specification including cutting , binding , bending and cost of binding wire. 2.634 Qtl.
7 7 Brick work with C.B. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge. 7.13 Cum
8 8 12mm thick cement plaster ( 1:6 ) over brick masonary 30.592 Sqm
9 9 Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. 8.052 Sqm
10 10 Filling F & P with excavated materials, moorum including watering and ramming as directed by the engineer-in-charge 750.071 cum
11 11 Supplying of 200 mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms. cc,of straight length of 6(six ) meter for portable water suppliers conforming to IS-4985/2000 of BIS- Amendment 2 read with Table =1 of IS specification bearing ISI marks for working pressure CI -IUO=PVC pipe to withstand pressure of 2.50 Kgf/sqcm and the specification and manufacturer name should be prominenity marked on body of each pipe as per the latest Amendment of IS 4985.it includes the cost of sockets in case of plain ended pipe Pre & Post delivery Inspection are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPT ,Bhubaneswar /EPM ,Orissa , Bhubaneswar necessary approval of authority including transporotation and laying at site all complete with cost of solvent cement. 834 Mtr.
12 12 Supplying of 200 mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms. cc,of straight length of 6(six ) meter for portable water suppliers conforming to IS-4985/2000 of BIS- Amendment 2 read with Table =1 of IS specification bearing ISI marks for working pressure CI -IUO=PVC pipe to withstand pressure of 4.00 Kgf/sqcm and the specification and manufacturer name should be prominenity marked on body of each pipe as per the latest Amendment of IS 4985.it includes the cost of sockets in case of plain ended pipe Pre & Post delivery Inspection are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPT ,Bhubaneswar /EPM ,Orissa , Bhubaneswar necessary approval of authority including transporotation and laying at site all complete with cost of solvent cement. 150 Mtr.
13 13 Cost of supplying transportation and fixing in proper place and position including required size full threaded TVS nut bolt , Rubber insertion & 4mm cupper wire 1 Ls
14 14 Monoblock centrifugal 5 Star rated pumpset 1700 LPM at 18 Mtr. Head(10 HP) squirrel cage induction motor companion flanges and class-F insulation suitable for operation at 415 volt + 6% - 15%, 3 phase 50Hz AC power supply confirming to IS 9079/2002 with ISI mark & guarnatee period & inclusive of cost of transportation to site & the pump set should be star rated. The manufacturer should be areputed company having wide dealership network and the spare parts should be easily available. The materials of construction as given below : \na) Casing: FC 200 as per IS 210/1978\nb) Impeller: Bronze grade LTB - 2 of IS 318/1981\nc) Shaft: High carbon steel grade 40 c 8 of IS 1570(part 2)\nd) Gasket: As per IS 5120/1977.\nNB: Pump set to be tested at PTL, OLIC, Bhubaneswar at random at contractor's cost. 1 No
15 15 Automatic Star Delta starter sheet steel enclosure suitable for operation of squirrel cage induction motor upto 10 HP with 25 Amp (AC-3) contactor at 415 volt +6% - 15%, 3 phase, 50 Hz, AC supply with suitable overload relay & No volt coil with electric pnemutic timer suitable for operation at voltage range of 300-440 volt including cost of transportation to site. The starter should provide dependable protection against overload and single phasing & should be of reputed brand having wide dealership network for easy availability of spares. \nNB: Starter will be sent to PTL, OLIC, Bhubaneswar at random for necessary testing at the contractor's cost. 1 No
16 16 3 ph 4 wire 20-100Amp 3x230Volt (P-N) current meter with ISI mark as approved by DISTCO CEDSU with matching fibre glass TP box for current meter including supplying ,testing and energisation with Kit -kat(Energy meter) 1 No
17 17 Pannel Board made of 18 gauge C.R. sheet (18"x11"x45") size with double coat painting over one coat primer with fitted of Denger Board. 1 No
18 18 Motor hood cover of 18 gauge C.R. sheet(18"x18"x24") with double coat painting over one coat primer so as to cover the motor 1 No
19 19 MS Base plate for fitting of pannel and pump as per sample 1 No
20 20 3 x 10 sqm Tarpodar Cable XLPE (Cross like polythylin) confirming to IS - 7098 (Part - II) including laying below 1 mtr of the ground & fitting the excavated materials including watering & ramming. 30 Mtr
21 21 63 AMP 415 volt T.P. main switch confirming to IS 4064(Pt-1& Pt-II) with utilisation category Ac-22 1 No
22 22 Supply ,fittintg and placing of 100mmdia Nominal Bore GI pipes having wall thickness 4.5mm electrical resistance welded of medimum class confirming to IS-1239(part-I /2004) with latest amendments ,screwed at both ends as per IS-554 socketed at 1 end and other end protected with plastic threaded protector .The socket confirming IS -1239 (Part-II/1992) with latest amendments in rendom length of 4 to 7 mtrs.Each pipe should bear ISI certification and manufacturers name /trade mark. 18 Mtr
23 23 Letter writings over display Board including painting with enamelled paint .Including cost of materials as per the direction of the Engineer-in-charge. 1 No
24 24 Labour charges for fitting ,fixing of suction ,delivery fitting including M.S Tee set ,NR valve, Switch valve and Air release valve etc minor welding transportation of materials to site etc. including nut, bolt rubber insallation etc complete. 1 Set
25 25 100mm dia C.I.screw base foot valve (Kirloskar make preferbely ) with ISI mark. 1 No
26 26 100mm dia G.I. bend IS No 1239(Part-II/1992) 5 No
27 27 100mm dia G.I.flange IS No 6392/1971 14 No
28 28 100 mm dia C.I.N.R valve IS No 5312(Part-I) with ISI mark 1 No
29 29 100mm dia C.I.sluice valve IS No 14846-2000(Part-I) 1 No
30 30 100mm dia G.I. Nipple 1 No
31 31 200x200x100mm dia M.S. Tee with 200mm ID & 216mm OD, 400mm long welder with 1 mtr.long 100mm dia M.S. pipe(medium duty) welded with two nos. of 100mm dia M.S. Flange in between the one mtr. long M.S. pipe and another 0.25 mtr. long 100mm dia M.S. (medium duty) pipe fitted horizontally with two nos. of 100mm dia M.S. elbow with water locking arrangement made out of one no. of 100mm dia open flange and one no. of 100mm dia blind flange with hinges, gaskets arrangement to enable inseration of 200mm dia UPVC pipe up to a length of 100mm both sides. The arrangement to be painted with two coats of anti corrosive paint. 7 No
32 32 200mm PVC equal Tee (6 Kgf/sqcm)confirming to PL-R PVC-IS 2000F 4 No
33 33 50mm dia C.I.A..R Valve IS Mark 14845(SI)with 1 mtr long G.I.Short piece with saddle 2 No
34 34 100x100x25 mm dia GI Tee for Priming with locking arrengement. 1 No
35 35 200mm dia PVC end cap confirming to PL-R PVC-IS 2000 F 1 No
36 36 200x100mm PVC/GI. reducing socket 1 No
37 37 200 mm PVC Sucket 3 No
38 38 100mm dia PVC FTA confirming to PL-R PVC-IS 2000 F 1 No
39 39 200mm dia PVC Elbow confirming to PL-R PVC-IS 2000 F 2 No
40 40 Cost of welding, for fitting of G.I.pipe ,G.I.bend, G.I. flange etc. 1 Set
41 41 Labour charges for 200mm PVC pipe fitting 984 Mtr
42 42 5KVR capacitor 1 No
43 43 Electrical Earthing with 40 mm dia medium duty GI earthing pipe each 3 m long with installation including cost of all materials like GI flange chorcoat, salt etc. as required as per I.E Rule 2 No
44 44 Labour charges for electrical installation with supply of electrical petty materials like 4 sq mm flexible wire, Black tape, Fuse wire,Condute pipe etc. 1 Set
45 45 Construction of Retaining Wall & Barbed wire fencing with RCC Pole, Sand & Metal spreading around the Sub Station, providing Grill gate with lucking arrengement. 1 No
46 46 Erection of 11 K.V.Line with all materials required for the same as per the detaild scope, quantity and specification given in the technically sanctioned estimate with 55 mm AAA Condcutor at 60 Mtr. Span etc. 0.1 KM
47 47 Commissioning of 11/0.4 KV (1X25 KVA) BIS Level 2 Sub-station with supply of all materials required for the same as per the detailed scope, quantity and specification given in the technically sanctioned estimate. 1 No
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail