Orissa Lift Irrigation Corporation Limited has published Construction Of Head Work,Distribution System & Power Supply Including Energisation Of Talapadar L.I.Project Under Kishorenagar Block Of Angul Districtinstallation And Energisation Of Talpadar Under Kishornagar Block In Angul District. Submission Date for this Tender is 09-11-2020. Pipe Laying Tenders in Angul Odisha. Bidders can get complete Tender details and download the document.
Name of Work: CONSTRUCTION OF HEAD WORK,DISTRIBUTION SYSTEM & POWER SUPPLY INCLUDING ENERGISATION OF TALAPADAR L.I.PROJECT UNDER KISHORENAGAR BLOCK OF ANGUL DISTRICT | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Earth work excavation in foundation in hard soil with 50 mtr initial lead 1.5 m initial lift including rough dressing and breaking clods to 2 cm to 7 cm and laying in layers not exceeding 0.3 m in depth as per direction of Engineer-in-charge | BI01010001010000000000000515BI0100001113 | 941.82 | cum |
2 | 2 | Filling foundation and plinth with sand watered and rammed as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001114 | 2.106 | Cum |
3 | 3 | Cement concrete ( 1:4:8) with 4 cm size h.g metal as per direction of engineer-in-charge. | BI01010001010000000000000515BI0100001115 | 2.106 | Cum |
4 | 4 | Cement concrete ( 1:2:4) with 12 cm size h.g Chips as per direction of engineer-in-charge. | BI01010001010000000000000515BI0100001116 | 4.275 | Cum |
5 | 5 | Column beams | BI01010001010000000000000515BI0100001117 | 56.5 | Sqm |
6 | 6 | Lintel slab | BI01010001010000000000000515BI0100001118 | 0.24 | Sqm |
7 | 7 | Supplying ,fitting and placing oncoated HYSD(TISCON) bar reinforcement complete as per drawing and technical specification .including cutting ,binding ,bending and cost of binding wire. | BI01010001010000000000000515BI0100001119 | 3.7 | Qtl. |
8 | 8 | Fly Ash Brick (25cmx12cm x8 cm) having crushing strength not less than 35kg/cm with dimensional tolerance ± 5% in cement mortar (1:6) in foundation and plinth. | BI01010001010000000000000515BI0100001120 | 2.19 | Cum |
9 | 9 | Filling F & P with excavated materials, moorum including watering and ramming as directed by the engineer-in-charge | BI01010001010000000000000515BI0100001121 | 941.82 | cum |
10 | 10 | 12mm thick cement plaster ( 1:6 ) over brick masonary | BI01010001010000000000000515BI0100001122 | 11.14 | Sqm |
11 | 11 | Cement punning of cement plaster | BI01010001010000000000000515BI0100001123 | 69.8 | Sqm |
12 | 12 | White washing two coats with shell time | BI01010001010000000000000515BI0100001124 | 3.84 | Sqm |
13 | 13 | 200 mm dia | BI01010001010000000000000515BI0100001125 | 1026 | Mtr |
14 | 14 | 10 HP Monoblock centrifugal pump set at total of 16mtr capable to discharge 1700 LPM squirrel cage induction motor fitted with companion flanges and class -F insulation suitable for operation 415 volt+6%-15% ,3phase ,50Hz AC power supply and full load current 15.6 amp with size of suction and delivery 100mmx100mm dia with overall efficiency 60 -65 .The materials of construction as given below. a) Casing :F.C. 200 as per IS 210/1978 b) Impeller : Bronze grade LTB-2 of IS c) Shaft : High carbon steel grade 40c8 of IS 1570(Part-2)318/1981 d) GAsket : As per IS 5120/1977 and the pump sets must be as per IS-9079/2002 of reputed brand having wide dealership net work for easy availability of spares. | BI01010001010000000000000515BI0100001126 | 1 | No |
15 | 15 | Supplying fitting fixing control pannel starter ,BCH make with arrangement of volt mewter ,Amp ,Meter mfitted with MCB control switch complete including indicator lamp with irrigation pannel bozard of apaproved design made out of 16gauge CR sheedt basement MS angle with double lock powder coat painting over one coat primere including fixing danager board with lucking devices and fixing of suitable stand for control pannel unit | BI01010001010000000000000515BI0100001127 | 1 | No |
16 | 16 | 3 oh 4 wire 20-100Amp 3x230Volt (P-N) current meter with ISI mark as approved by DISTCO CEDSU with matching fibre glass TP box for current meter including supplying ,testing and energisation wsith Kit -kat(Energy meter) | BI01010001010000000000000515BI0100001128 | 1 | No |
17 | 17 | Motor hood cover of 18 gauge C.R. sheet with double coat painting over one coat primer so as to cover the motor | BI01010001010000000000000515BI0100001129 | 1 | No |
18 | 18 | MS base plate for fitting of pannel and pump as per sample | BI01010001010000000000000515BI0100001130 | 1 | No |
19 | 19 | 3 x 10 sqm Tarpodar Cable XLPE (Cross like polythylin) confirming to IS - 7098 (Part - II) including laying below 9 mtr of the ground & fitting the excavated materials including watering & ramming. | BI01010001010000000000000515BI0100001131 | 80 | Mtr |
20 | 20 | 63/100 AMP 415 volt T.P. main switch confirming to IS 4064(Pt-1& Pt-II) with utilisation category Ac-22 | BI01010001010000000000000515BI0100001132 | 1 | No |
21 | 21 | Supply ,fittintg and placing of 100mmdia Nominal Bore GI pipes having wall thickness 4.5mmelectrical resistance welded of medimum class confirming to IS-1239(part-I /2004) with latest amendments ,screwed at both ends as per IS-554 socketed at 1 end and other end protected with plastic threaded protector .The socket confirming IS -1239 (Part-II/1992) with latest amendments in rendom length of 4 to 7 mtrs.Each pipe should bear ISI certification and manufacturers name /trade mark. | BI01010001010000000000000515BI0100001133 | 18 | Mtr |
22 | 22 | Labour charges for fitting ,fixing of suction ,delivery fitting including M.S Tee set ,NR valve, Switch valve and Air release valve etc minor welding transportation of materials to site etc. including nut, bolt rubber insallation etc complete. | BI01010001010000000000000515BI0100001134 | 1 | Set |
23 | 23 | 100mm dia C.I.screw base foot valve (Kirloskar make )IS | BI01010001010000000000000515BI0100001135 | 1 | No |
24 | 24 | 100mm dia G.I. bend IS No 1239(Part-II/1992) | BI01010001010000000000000515BI0100001136 | 4 | No |
25 | 25 | 100mm dia G.I.flange IS No 6392/1971 | BI01010001010000000000000515BI0100001137 | 8 | No |
26 | 26 | 100 mm dia C.I.N.R valve IS No 5312(Part-I) with ISI mark | BI01010001010000000000000515BI0100001138 | 1 | No |
27 | 27 | 100mm dia C.I.sluice valve IS No 14846-2000(Part-I) | BI01010001010000000000000515BI0100001139 | 1 | No |
28 | 28 | 160x160x100mm MS Tee set with bend,closing and opening arrangement | BI01010001010000000000000515BI0100001140 | 10 | No |
29 | 29 | 200x200x200 mm PVC equal Tee | BI01010001010000000000000515BI0100001141 | 2 | Set |
30 | 30 | 200 mm dia PVC end cap | BI01010001010000000000000515BI0100001142 | 4 | No |
31 | 31 | 50mm dia C.I.A..R Valve IS Mark 14845(SI)with 1 mtr long G.I.Short piece with saddle | BI01010001010000000000000515BI0100001143 | 2 | No |
32 | 32 | 100mm dia GI Priming set | BI01010001010000000000000515BI0100001144 | 1 | No |
33 | 33 | 200x100mm M.S reducing socket IS 2000F | BI01010001010000000000000515BI0100001145 | 1 | No |
34 | 34 | 200mm PVC pipe laying and fitting | BI01010001010000000000000515BI0100001146 | 1026 | Mtr |
35 | 35 | Construction of 3 phase 11 KV line as per REC standard confirming to RE Rules 1956 with 300 Kg 10 M long PSC Pole support in 50 M span, 55 Sqmm Insulated Conductor, 11 KV "V" Cross arm , with required No.of 11 KV T & C Disc.Insulators & 11 KV Pin Insulators, Carping & Padding of Poles, Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & Double Stay at end point with 18 mm G.I. H.T Stay , concreting of Stay with Anchor plate, guarding at Road crossings etc.including cost of all materials, labour ,transpotation,inspection & commissioning etc.complete. | BI01010001010000000000000515BI0100001147 | 0.05 | KM |
36 | 36 | ii. 25KVA Transformer only | BI01010001010000000000000515BI0100001148 | 1 | No |
37 | 37 | Electrical Earthing with 40mtr dia medium duty Flat earthing pipe each 3 m longwith installation including cost of all materials like GI flange chorcoat, salf etc. as required as per I.E Rule | BI01010001010000000000000515BI0100001149 | 2 | No |
38 | 38 | Other Electrical materials such as pvc tape.7/20pvc copper wire 3/20 pvc copper wire G.I flxible condite pipe no 6 GI wire copper cable socket GI socket and petty materials required for electrical installation. All materials should be as per IS including fitting charges | BI01010001010000000000000515BI0100001150 | 1 | Set |
39 | 39 | Cost of document which includes pre and post photograph (2 copies) power supply agreement of pani panchayat office bearers with CESU authorities ,handing over documents( agreement ) of pani panchayat with O.LIC authority recording of latityde and longitude etc complete | BI01010001010000000000000515BI0100001151 | 1 | Each |