Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sh- Amc For Automatic Fire Alarm And Detection System At Ndcc Ph-Ii And Convention Centre , New Delhi, NDCC PH-II and Convention Centre-Delhi

New Delhi Municipal Council-NDMC has published Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sh- Amc For Automatic Fire Alarm And Detection System At Ndcc Ph-Ii And Convention Centre , New Delhi. Submission Date for this Tender is 27-10-2020. Fire Alarm Systems Tenders in NDCC PH-II and Convention Centre Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

25763943
Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sh- Amc For Automatic Fire Alarm And Detection System At Ndcc Ph-Ii And Convention Centre , New Delhi
Open Tender
Indian
Delhi
NDCC PH-II and Convention Centre
27-10-2020

Tender Details

Annual Repair And Maintenance Of fire alarm , detection and pa cum talk back system at various ndmc buildings during 2020-21 . sh- amc for automatic fire alarm and detection system at ndcc ph-ii and convention centre , new delhi

Key Value

Document Fees
Refer document
EMD
INR 9508.0 /-
Tender Value
INR 4.75 Lakhs /-

BOQ Items

Name of Work: AMC for Automatic Fire Alarm and Detection System at NDCC P-II and Convention Centre, New Delhi
Sl. No. Item Description Item Code / Make Quantity Units
1 1 AMC for Fire Alarm and Detection Systems installed at below cited buildings including weekly visits and whenever required or in case of any defect in the system by the Team consisting of Engineer, Technicians and Helpers with the aim to keep the system functional round the clock including servicing, maintenance, testing, checking the loops using software and keeping them in order and cleaning the system internally as well as externally complete to the entire satisfaction of Fire Officer/Engineer In Charge. The inventory installed in the building for servicing, maintenance, testing & keeping the system in perfect order is available at the respective control rooms complete to the entire satisfaction of Fire Officer/Engineer In Charge.\n\nNDCC P-II and Convention Centre\n\n1. 13 Loops Addressable Bosch make - 01 No.\n2. 6 Loops Addressable Bosch make - 01 No.\n3. Main Call Point - 80 Nos.\n4. Hooter - 15 Nos.\n5. Smoke Detectors - - 800 Nos.\n6. Panel Controller - 02 Nos.\n7. Customized Rack - 01 No.\n8. Armoured & Unarmoured cable / wire - As per actual\n\n(Inventory mentioned is for indicative purpose only. However actual inventory may be seen at the respective building before quoting the rates.)\n\na) Engineer - 1 No. - 01 Visit / Week\nb) Technical Foreman - 01 No. - 01 Visit / Week\nc) Helper - 02 Nos. - 01 Visit (Each) / Week
2 1.01 Engineer - 1 No. 52 Visits
3 1.02 Technician - 1 No. 52 Visits
4 1.03 Helper - 2 Nos. 104 Visits
5 2 Replacement / Supply, Installation, Testing and Commissioning of Addressable Optical Smoke Detector (Model No FAP-O-425) including mounting base with LED… etc. complete as required, Each Detector should have inbuilt isolator for maintaining operational availability of all elements in the loop, even in the event of a short circuit & Drift Compensation feature & Automatic addressing. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 Shall be EN54/ VDscertification. (Make Bosch only) 37 Nos.
6 3 Replacement / Supply, Installation, Testing and Commissioning of addressable Stand alone Loop Powered Addressable Sounder Model No. FNM-420-A-BS-RD with multi programmable tones/ sound patterns. The sound pressure not less than 90 DB, Sounder and Strobe both should be programmed from the panel shall be VDS . (In case of separately powered sounders, cost of the power cable shall be inclusive in the cost of sounders itself and shall not be paid separately and power of sounders shall be fed from main Fire Alarm Panel only) (Make Bosch only) 3 Nos.
7 4 Replacement / Supply, Installation, Testing and Commissioning of Addressable Manual Break Glass/ flap Unit (Double action) (Model No FMC-210-DM-G-R ) with flexible network structures & necessary fixing arrangements with key complete as required shall be VDS (following EN54 Standard) approved in all respected to the entire satisfaction of Fire Officer/Engineer Incharge (Make Bosch only) 11 Nos.
8 5 Credit of unserviceable material in all respect to the entire satisfaction of Fire Officer
9 5.01 Addressable Optical Smoke Detector from Item No. 2 37 Nos.
10 5.02 Addressable Sounder from Item No. 3 3 Nos.
11 5.03 Addressable Manual Break Glass/ flap Unit from Item No. 4 11 Nos.
Disclaimer :