Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sh- Amc For Semi Addressable Fire Alarm , Detection And Public Address And Epabx Systems Installed At Disaster Management C, Disaster Management Centre, Humayun Road-Delhi

New Delhi Municipal Council-NDMC has published Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sh- Amc For Semi Addressable Fire Alarm , Detection And Public Address And Epabx Systems Installed At Disaster Management C. Submission Date for this Tender is 27-10-2020. clocks Tenders in Disaster Management Centre, Humayun Road Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

25763841
Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sh- Amc For Semi Addressable Fire Alarm , Detection And Public Address And Epabx Systems Installed At Disaster Management C
Open Tender
Indian
Delhi
Disaster Management Centre, Humayun Road
27-10-2020

Tender Details

Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sh- Amc For Semi Addressable Fire Alarm , Detection And Public Address And Epabx Systems Installed At Disaster Management Centre , Humayun Road . , Amc For Semi Addressable Fire Alarm , Detection , Public Address And Epabx System At Disaster Management Centre Including Four Visit Per Month By Engineer With Technician And Helper And Whenever Required Or Called In Case Of Any Defect In System For Servicing , Maintenance , Testing , Cleaning Of The System Required For Proper Working Condition Round The Clock Etc Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge As Per Existing Details Below - A . Public Address System 1 6 Watt Ceiling Speaker - 15 Nos 2 15 Watt Outdoor Horn Speaker - 04 Nos 3 Voice Alarm Controller - 01 No 4 6 Zone Voice Alarm Call Station - 03 Nos 5 240 Watt Booster Amplifier - 03 Nos 6 Dvd / Mp3 Player - 01 No 7 Speaker Cable 2 Corex1 . 5 Sq Mm Micc - 440 M 8 Glands And Plain Seal - 40 Nos 9 Junction Box - 20 Nos 10 Main Junction Box - 01 No 11 M . S . Equipment Rack - 01 No , Engineer - 1 No . , Technician - 1 No . , Helper - 2 Nos . , B . Fire Alarm Systems 1 Microprocessor Based 2 Loops Analogue Addressable Type Fire Alarm Control Panel - 01 No 2 Repeater Panel For Fire Alarm System - 01 No 3 Analogue Addressable Photo Electric Smoke Detectors - 20 Nos . 4 Analogue Addressable Manual Call Point - 04 Nos . 5 Analogue Addressable Electric Hooter / Sounders - 04 Nos . 6 Junction Box - 28 Nos . 7 2 Core 1 . 5 Sq . Mm Micc Cable - 450 M 8 Glands And Plane Seals - 64 Nos . C . Epabx System As Available At Fire Control Room , Engineer - 1 No . , Technician - 1 No . , Helper - 2 Nos . , Replacement / Supplying , Installation , Testing & Commissioning Of Main Transformer Of Bosch Plena Amplifier 240 Watt Complete As Required Model No . Lbd-1930 / Lbd -1935 , Supplying , Installation , Testing & Commissioning Of Mic Cartridge Bosch Goosneck Mic Complete As Required Model No . Lbb-1949 , Replacement / Supplying , Installation , Testing & Commissioning Of Main Pcb Of Bosch Plena Amplifier Complete As Required Model No . Lbd-1930 / Lbd - 1935 , Replacement / Supplying , Installation , Testing & Commissioning Of Fire Alarm Loop Card Of Bosch For 2 Lopp Panel Complete As Required Model No . Fpa-5000 , Supplying , Installation , Testing & Commissioning Of Pcb Of Bosch Plena Call Station Complete As Required Model No . Lbb-1956

Key Value

Document Fees
Refer document
EMD
INR 9494.0 /-
Tender Value
INR 4.74 Lakhs /-

BOQ Items

Name of Work: AMC for Semi Addressable Fire Alarm & Detection and Public Address & EPABX Systems installed at Disaster Management Centre, Humayun Road.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 AMC for Semi Addressable Fire Alarm, Detection, Public Address and EPABX System at Disaster Management Centre including four visit per month by Engineer with Technician and helper and whenever required or called in case of any defect in system for servicing, maintenance, testing, cleaning of the system required for proper working condition round the clock etc Complete in all respect to the entire satisfaction of Fire Officer / Engineer In-charge as per existing details below -\n\nA. Public Address System \n1 6 watt Ceiling Speaker - 15 Nos\n2 15 Watt Outdoor Horn speaker - 04 Nos\n3 Voice alarm Controller - 01 No\n4 6 Zone Voice alarm call station - 03 Nos\n5 240 watt booster amplifier - 03 Nos\n6 DVD/MP3 player - 01 No\n7 Speaker cable 2 corex1.5 Sq mm MICC - 440 M\n8 Glands and plain seal - 40 Nos\n9 Junction Box - 20 Nos\n10 Main Junction Box - 01 No\n11 M.S. Equipment Rack - 01 No
2 1.01 Engineer - 1 No. 52 Visits
3 1.02 Technician - 1 No. 52 Visits
4 1.03 Helper - 2 Nos. 104 Visits
5 2 B. Fire Alarm Systems\n1 Microprocessor based 2 loops analogue addressable type fire alarm control panel - 01 No\n2 Repeater panel for fire alarm system - 01 No\n3 Analogue addressable photo electric smoke detectors - 20 Nos.\n4 analogue addressable manual call point - 04 Nos.\n5 analogue addressable electric hooter/ sounders - 04 Nos.\n6 Junction Box - 28 Nos.\n7 2 core 1.5 sq.mm MICC Cable - 450 M\n8 Glands and plane seals - 64 Nos.\n\nC. EPABX System\nAs available at Fire Control Room\n
6 2.01 Engineer - 1 No. 52 Visits
7 2.02 Technician - 1 No. 52 Visits
8 2.03 Helper - 2 Nos. 104 Visits
9 3 Replacement / Supplying, installation, testing & commissioning of Main Transformer of BOSCH Plena amplifier 240 watt complete as required\nModel No. LBD-1930 / LBD -1935 1 No.
10 4 Supplying, installation, testing & commissioning of Mic Cartridge BOSCH Goosneck Mic complete as required\nModel No. LBB-1949 3 Nos.
11 5 Replacement / Supplying, installation, testing & commissioning of Main PCB of BOSCH Plena amplifier complete as required\nModel No. LBD-1930 / LBD - 1935 1 No.
12 6 Replacement / Supplying, installation, testing & commissioning of Fire Alarm Loop Card of BOSCH for 2 lopp panel complete as required\nModel No. FPA-5000 1 No.
13 7 Supplying, installation, testing & commissioning of PCB of BOSCH Plena Call Station complete as required\nModel No. LBB-1956 1 No.
Disclaimer :