Special Repairs For Augmentation Of Standby Power Supply Of Perimeter Fencing At Pedong And Spl Repairs To Bldg No . T-228 At Teesta Tcp Under Ge 867 Ews, Pedong-West Bengal

Military Engineer Services-MES has published Special Repairs For Augmentation Of Standby Power Supply Of Perimeter Fencing At Pedong And Spl Repairs To Bldg No . T-228 At Teesta Tcp Under Ge 867 Ews. Submission Date for this Tender is 09-11-2020. Power Supply Unit Tenders in Pedong West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

25761169
Special Repairs For Augmentation Of Standby Power Supply Of Perimeter Fencing At Pedong And Spl Repairs To Bldg No . T-228 At Teesta Tcp Under Ge 867 Ews
Open Tender
Indian
West Bengal
Pedong
09-11-2020

Tender Details

Special Repairs For Augmentation Of Standby Power Supply Of Perimeter Fencing At Pedong And Spl Repairs To Bldg No . T-228 At Teesta Tcp Under Ge 867 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 25500.0 /-
Tender Value
INR 12.75 Lakhs /-

BOQ Items

Name of Work: SPL REPAIRS FOR AUGMENTATION OF STANDBY POWER SUPPLY OF PERIMETER FENCING AT PEDONG AND SPL REPAIRS TO BLDG NO. T-228 AT TEESTA TCP UNDER GE 867 EWS
Sl. No. Item Description Item Code / Make Approx No of Units Reqd UNIT
1 1 S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap fixed with "L" or "J" type hook bolts and bitumen washers as in roof covering etc., with grade of Zinc coating 275 Grms/Sqm including taking down existing steel sheetng of any type complete all as specified and directed by Engineer-in-Charge.\n 58 SQUARE METRE
2 2 S&F 0.80 mm thick galvanised, plain mild steel sheeting fixed with "L" or "J" type hook bolts and bitumen washers as in ridges, hips,valley gutters, drip and straight flashing etc.,with grade of Zinc coating 275 Grms/Sqm including taking down existing steel sheetng of any type complete all as specified and directed by Engineer-in-Charge.\n 3 SQUARE METRE
3 3 Taking down existing 0.63 mm thick galvanised, corrugated mild steel sheeting and refixing in same location or in new location in same building with two corrugation side lap fixed with "L" or "J" type hook bolts and bitumen washers as in roof covering etc., complete all as specified and directed by Engineer-in-Charge. 12 SQUARE METRE
4 4 Dismantling timber scantlings 40 Sqcm and over in section, framed work in any position complete all as specified and directed by Engineer-in-Charge. 0.4 CUBIC METRE
5 5 S&F Fe 410-W (Gde-E- 250) quality-A Rolled steel sections, as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed by Engineer-in-charge. 300 KILOGRAM
6 6 M&L preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge. 12 SQUARE METRE
7 7 M&L for preparation of new or previously un treated surfaces of steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.\nMake for Item No. 6&7: ASIAN/ SHALIMAR/ BERGER/ JENSON&NICHOLSON/IEL/NEROLAC/IEL 30 SQUARE METRE
8 8 M & L for modular fly ash bricks as in brick work straight or curved on plan exceeding 6m mean radious built in cement mortar 1:6 including demolition of existing brickwork complete all as specified and directed by Engineer-in-charge. 0.75 CUBIC METRE
9 9 Taking down cement plaster on brick or stone masonry surfaces of walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removing rubbish off the premises complete all as specified and directed by Engr-in-charge. 135 SQUARE METRE
10 10 M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge. 60 SQUARE METRE
11 11 M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions complete all as specified and directed by Engr-in-charge.\n 85 SQUARE METRE
12 12 M&L for preparing newly plastered surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.\nMake: LOVELYCEM/ SURYACEM/ JANATHACEM / LUCKYCEM or equivalent make as approved by GE. 145 SQUARE METRE
13 13 Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.5 Sqm and not exceeding 4 sqm each, including cutting holes for taking out hold fasts or dismantling brick work and making good in PCC 1:2:4 type B1 or cement mortar 1:4 (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed. 2 EACH
14 14 Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each, including cutting holes for taking out hold fasts or dismantling brick work and making good in PCC 1:2:4 type B1 or cement mortar 1:4 (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed. 2 EACH
15 15 S&F steel window with side hung shutters (glazed or wire mesh shutters) fitted with box type hinges with suitable MS handles, peg stays, with glazing bars for receiving glass / MS flat for receiving wire mesh complete all as directed by Engr-in-charge.\nMake: M/s Madhu industries / M/s.SEN Harvick / AVA STEELS /M/s. Shiv Mular / M/s. AGEW. / M/s. Multiwyn Industries Corpn/ M/s Ganesh rolling shutters/M/s Venkateswara rolling shutters or equvalent make as approved by GE. 2 SQUARE METRE
16 16 S&F Mild steel works as in grills, framed guard bars, and similar works conforming to Fe-290, Gde E-165 all as specified and directed. 20 KILOGRAM
17 17 S & F 3mm thick sheet glass ordinary quality fixed with oil putty and necessary clips/nut bolts area not exceeding 0.5Sqm in each pane complete all as directed by Engr-in-Charge.\nMake: TRIVENI/ SAINT GOBAIN/ MODIGUARD/ATUL/ HINDUSTAN or equivalent as approved by GE. 1.8 SQUARE METRE
18 18 S & F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples or wooden beeds all as specified and directed by Engr-in-Charge.\nMake: -Kamal/Shalimar or equivalent as approved by GE. 1 SQUARE METRE
19 19 S & F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples or wooden beeds including taking down existing wire cloth complete all as specified and directed by Engr-in-Charge.\nMake: -Kamal/Shalimar or equivalent as approved by GE. 3.5 SQUARE METRE
20 20 S&F 125x60 mm size pressed steel door frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C0 filling complete all as directed by Engr-in-Charge.\nMake: - DIWAN STEELS/Ajanta Ispat/AVA Steels or equivalent as approved by GE.\n 5.2 RUNNING METRE
21 21 S&F 105x60 mm size pressed steel door frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C0 filling complete all as directed by Engr-in-Charge.\nMake: - DIWAN STEELS/Ajanta Ispat/AVA Steels or equivalent as approved by GE.\n 4.8 RUNNING METRE
22 22 S&F 30mm thick factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both faces complete all as specified and directed by Engineer-in-Charge.\nMake: - Green Ply/Archid Ply or equivalent as approved by GE. 3.9 SQUARE METRE
23 23 S&F 200 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed. 4 EACH
24 24 S&F 150 mm long Aluminium alloy handles cast type anodised all as specified and directed. 4 EACH
25 25 S&F 250mm long aluminium alloy anodised sliding door bolts with hasp & staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.\nMake for Item No. 23 to 25: - CROWN/ CLASSIC/ JYOTHI/ AMIT/ MOWJEE/ARGENT/Bharat/Alans/Hettich/Everlite or any ISI marked make as approved by GE. 2 EACH
26 26 M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 6 mm wide grooves to full depth at 2m to 3m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight including demolition of existing plinth protection and removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge. 20 SQUARE METRE
27 27 Forming 65 mm deep x 10 mm wide construction (Dummy) joint filled with sealing compound grade A complete all as specified and directed by Engineer-in-Charge. 0.7 TEN RUNNING METRES
28 28 M&L for 40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in floors as sub base and finishing even and rough to receive toping layer including demolition of existing flooring and removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge. 40 SQUARE METRE
29 29 M&L for non skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engr-in-charge. 40 SQUARE METRE
30 30 M&L for non skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, ion vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick rendering in cement mortar 1:4 backing coat complete all as specified and directed by Engr-in-charge. 2.8 SQUARE METRE
31 31 M&L for coloured glazed ceramic tiles of size 300x200x7mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick rendering in cement mortar 1:4 backing coat complete all as specified and directed by Engr-in-charge.\nMake for Item No 29 to 31: NITCO/ SOMANY/ ASIAN / JOHNSON/ORIENT 6 SQUARE METRE
32 32 M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge. 11 POINT
33 33 All as per item No. 32 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge. 3 POINT
34 34 M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.\n 3 POINT
35 35 M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing & caping of 25mm size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge.\nNote: 2 runs of 4 Sqmm and one run of 4 Sqmm and one run of Casing&Caping shall be measured as one unit length.\nMake for Item No. 32 to 35\nCable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor\nCasing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza 10 RUNNING METRE
36 36 S&F switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge. 8 EACH
37 37 S&F switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge. 6 EACH
38 38 S&F switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge. 3 EACH
39 39 S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge. 2 EACH
40 40 S&F ceiling rose 3 terminal PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge.\nMake for Item No. 36 to 40: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh 6 EACH
41 41 S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated, double door including taking down existing DB complete all as specified and as directed by Engineer-in-Charge.\nMake: Legrand/Siemens/Schindler 1 EACH
42 42 Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with solid aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. 600 RUNNING METRE
43 43 Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. 312 RUNNING METRE
44 44 Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.\nNote for Item No. 42 to 44:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI 350 RUNNING METRE
45 45 Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5 in depth for taking out /laying of cable etc., and getting out in soft/loose soil.complete all as specified and directed by Engineer-in-Charge. 270 CUBIC METRE
46 46 Returning, filling in soil, including spreading leveling, watering and wall ramming in laying not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge. 170 CUBIC METRE
47 47 Removing excavated soil to a distance n.exe 50m and depositing where directed at alevel n.exe 1.5m above the starting point complete all as directed by Engineer - in -Charge. 100 CUBIC METRE
48 48 Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge.\nNote:- Punned thickness only shall be measured for payment purpose. 81 CUBIC METRE
49 49 M&L for common burnt bricks, sub class 'B', of size 250 x 125 x 75 mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge. 8 ONE THOUSAND NUMBERS
50 50 Material and labour for 50 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge.\nMake: TATA/ZENITH/JINDAL 42 RUNNING METRE
51 51 Earhing complete with galvanized steel earth plate electrode 600X600X6 mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to GI earth strip of size 32x6mm, by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and suitable handle of 10 mm dia round bar, 40 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge.\nNOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m. 2 EACH SET
52 52 M & L for DK Thermoplastic cable junction boxes IP 65 of size 185x165x60mm of metric knockouts for cable entry, weather proof for outdoor installation with and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 16/25sqmm 2 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and bolts incl provn of 01 No of single pole MCB 6-32 amps,10KA ‘B’ series inside the box complete including taking down existing existing junction box all as specified and directed by Engineer-in-Charge.\nNOTE: Make of Junction box shall be Sintex/Hensel or equivalent as approved by GE. 45 EACH
53 53 Supply, installation, commissioning and testing 3 phase 4 wire 50 Hz, 433 volts, 50 KA fault level, LT outdoor panel board factory made CPRI approved, cubical type panel with individual compartment for switchgears/MCCB, with front and rear openable doors with screwed knobs, bending of edges, with suitable rubber/neoprene gaskets at edges, fabricated out of CRCA sheet 3.15 mm thick and frame of angle iron 50 x 50 x 6 mm duly welded including cable entry and exit through glands at bottom including powder coated on both outer and inner surfaces for panel, internal connection from bus bar to switchgears/MCCB, including copper bus bars of capacity 200 Amps for RYB and 100 Amps Rating for N, Digital amp meter 0-100 amp, Digital Volt meter 0-500 Volts, Amp meter selector switch, and Volt meter selector switch, including PCC foundation and the size of panel shall be suitable for accommodating following items including dismantling old panel complete all as specified and directed by the Engineer -In-Charge: -\n(i) MCCB 4 Pole 100 Amp breaking capacity 35 KA, 415 Volts, 50 Hz, AC thermal magnatic setting Ics=100% Icu - 03 Nos.\n(ii) MCCB 4 Pole of 63 Amps, breaking capacity 35 KA, 415 Volts, 50 Hz, AC, thermal and fixed magnatic setting - 02 Nos.\n(iii) Surge protecor device t1+t2 of 25 KA - 01 No.\nNOTE: Layout sketch of the panel board shall be got approved by GE before incorporation in the work.\nMake of Switchgear: Legrand/Siemens/Schindler 1 JOB
54 54 Sub Total of Schedule 'A'
55 55 Schedule of Credit (Minus) Rs. 66,720.00 B/F from Ser page No. 30 \nNOTE: Bidder shall insert credit amount as rate Rs. 66,720.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender. 1 EACH
56 56 Sub Total of Schedule of Credit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy