Military Engineer Services-MES has published Repair And Maintenance Of Water Supply Installations , Ro Plants/ Dosing Pumps , Pressure Pump , Monoblock Pump , Main Of External Electrification Services , Street Lights , Perimeter Security Lights And Allied E/M Works At Af Stn Gandhinagar. Submission Date for this Tender is 05-11-2020. Electrification Work Tenders in GANDHINAGAR Gujarat. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR AND MAINTENANCE OF WATER SUPPLY INSTALLATIONS, RO PLANTS/ DOSING PUMPS, PRESSURE PUMP, MONOBLOCK PUMP, MAIN OF EXTERNAL ELECTRIFICATION SERVICES, STREET LIGHTS, PERIMETER SECURITY LIGHTS AND ALLIED E/M WORKS AT AF STN GANDHINAGAR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Testing of Bore well water/ RO water to analysis the following parameter as per IS 10500 : 2000 through Govt. approved agency:-\n(a) Physicochemical parameters of water/ eflluent sample\n(b) Bactoriological test of water sample.\n(c) Metals (Expect Hg, As & Se).\n(d) Pesticides. | 2 | EACH | |
2 | 2 | Servicing and non comprehencive annual maintenance of RO plant of 5000 ltr/hr capacity (make-ion exchange) with authorised service centre of ion exchange complete all as specified and as directed.\nNote:- 1. This include visit of the technician of ion excahnge every month in any working days and look after the system regularly and observe and maintain the record of the performance, back wash the filter at regular intervals, check the anti scalant and add the chemical as required, cleaning of sediementation filter, cleaning of cartridge and membrane, check of control panel and system pressure and RO element for proper operation of the system. \n2. Changed spare parts will be paid separately. | 9 | EACH JOB | |
3 | 3 | Supply only in repairs Jumbo filter 20" for 5000 Ltr RO plant complete all as specified and as directed.\n | 1 | EACH | |
4 | 4 | Supply only in repairs anti-scalanent chemical 8211 for 5000 Ltr RO plant complete all as specified and as directed. | 25 | LTR | |
5 | 5 | Supply only in repairs membrane hydra 8040 for 5000 Ltr RO plant complete all as specified and as directed.\n | 1 | EACH | |
6 | 6 | Supply only in repairs UV lamp for 5000 Ltr RO plant complete all as specified and as directed.\n | 1 | EACH | |
7 | 7 | S&F in repairs UV system for 5000 ltr RO plant complete all as specified and as directed.\n | 1 | EACH | |
8 | 8 | S&F in repairs multi port valve suitable for existing 5000 Ltr plant complete all as specified and as directed.\n | 1 | EACH | |
9 | 9 | Supply only in repairs high pressure switch suitable for 5000 ltrs RO plant complete all as specified and as directed. | 1 | EACH | |
10 | 10 | Supply only in repairs low pressure switch suitable for 5000 ltrs RO plant complete all as specified and as directed. | 1 | EACH | |
11 | 11 | Supply only in repairs solenoid valve for 5000 Ltr RO plant complete all as specified and as directed.\n | 1 | EACH | |
12 | 12 | Supply only in repairs multi filter housing suitable for existing 5000 ltr RO plant complete all as specified and as directed. | 1 | EACH | |
13 | 13 | Supply only in repairs dosing pump suitable for existing 5000 ltr RO plant complete all as specified and as directed. | 1 | EACH | |
14 | 14 | Supply only in repairs control panel suitable for existing 5000 ltr RO plant complete all as specified and as directed. | 1 | EACH | |
15 | 15 | S&F in repairs vessel 1354 of existing make suitable for 5000 ltrs RO plant complete all as specified and as directed. | 1 | EACH | |
16 | 16 | Supply only sodium hypochlorite solution 90 to 120 GPL in PVC container of 35 Ltrs capacity complete all as specified and as directed. | 1000 | LTRS | |
17 | 17 | S&F in repairs 15 mm bore unplasticised PVC pipes of pressure rating 10 kgf/ sqcm with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed.\nNote:- Excavation/ earth work will be measured and paid separately under respective items. | 40 | RM | |
18 | 18 | All as per Item No. 17.00 above, but 20 mm bore UPVC tubing complete. | 30 | RM | |
19 | 19 | All as per Item No 17.00 above, but 25 mm bore UPVC tubing complete. | 30 | RM | |
20 | 20 | S& in repairs gun metal foot valve 80/ 100mm size complete all as specified and as directed. | 1 | EACH | |
21 | 21 | M&L for construction of 3mm thick MS Sheet cover fixed on 40mmx40mmx6mm thick angle iron frame embedded in PCC coping with locking arrangement and mild steel surface with two coats of red oxide primer etc. complete all as specified and as directed. | 6 | EACH | |
22 | 22 | M&L for preparation of old pipe line of DI or GI surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete with showing arrow in water flowing direction in white colour complete all as specified and as directed. | 20 | SQM | |
23 | 23 | M&L for preparation of new pipe line of DI or GI surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete with showing arrow in water flowing direction in white colour complete all as specified and as directed. | 30 | SQM | |
24 | 24 | Repair to submersible pumping set capacity 25 HP, 440V, 3 Phase discharged 510 LPM at 123 Metre head consisting of following:-\nOpening of submersible motor and cutting to burnt winding and cleaning to slots by cleaning and repairs to damage starter etc, rewinding to submersible motor with suitable size of superior quality copper winding wire insulating materials all as directed by Engineer in charge. \n(a) Replacement of thrust bearing – 01 No.\n(b) Replacement of bush – 02 Nos.\n(c) Re-assembling and transporting to Pump House,lowering pump and testing complete.\nDismantling of submersible pump set all as directed and replacement of the following items:-\n(i) Replacement of neck ring – 05 Nos. \n(ii) Replacement of brass bushes – 05 Nos.\n(iii) Replacement of shaft bush - 02 Nos.\n(iv) Replacement of impeller - 05 Nos. | 1 | EACH JOB | |
25 | 25 | Repairs to submersible pumping set capacity 45 HP, 440V, 3 Phase discharged 800 LPM at 160 Metre head consisting of following:-\nOpening of submersible motor and cutting to burnt winding and cleaning to slots by cleaning and repair to damage starter etc, rewinding to submersible motor with suitable size of superior quality copper winding wire insulating materials all as directed by Engineer in charge. \n(a) Replacement of thrust bearing – 01 No.\n(b) Replacement of bush – 02 Nos.\n(c) Re-assembling and transporting to Pump House,lowering pump and testing complete.\nDismantling of submersible pump set all as directed and replacement of the following items:-\n(i) Replacement all neck ring. \n(ii) Replacement of all brass bushes.\n(iii) Replacement of all shaft bush.\n(iv) Replacement of all impeller. | 1 | EACH JOB | |
26 | 26 | Lowering and lifting of existing pump set and repaired pump set with taking out carefully of column pipe of 80/ 100 mm size each length of 3 mtr with from 120 mtr depth all as required at site and including cable proper fixing with pump set and column pipe and making connection with existing starter all as required at site and as directed by Engineer-in-charge. | 4 | EACH JOB | |
27 | 27 | S&F in repairs flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 10 Sqmm fixed to wall/ in duct, laid in floor/ trench or fixed to bore well motor etc. complete all as specified and as directed.\nNote:- Lifting lowering of bore well pump/ motor will be paid separately. | 220 | RM | |
28 | 28 | S&F in repairs flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 25 Sqmm fixed to wall/ in duct, laid in floor/ trench or fixed to bore well motor etc. complete all as specified and as directed.\nNote:- Lifting lowering of bore well pump/ motor will be paid separately. | 50 | RM | |
29 | 29 | Taking out the bore well pump with bore well lifting machine and disconnecting the all electrical connection and install after fixing MS pipe heavy column pipe to bore well motor with accessories to fix the bore well pump and done all the electrical connection as existing complete all as specified and as directed.\n | 150 | RM | |
30 | 30 | Comprehensive maintenance and servicing of chlorine dosing equipment self priming, having discharge capacity up to 5 Ltrs/ Hour of existing make per month, making the plant fully serviceable at the following locations:- \nNote:- (i) Spares required for replacement will be measured and paid separately under respective items here-in this schedule. (ii) The rate quoted by the tenderer includes cost of maint/ servicing of above said plant in a period of 90 days till the date of completion of work.\n(iii) Rate inclusive of replacement of parts day during currency of contract as and when directed by Engineer-in-Charge. | 3 | PER THREE MONTH | |
31 | 31 | Comprehensive maintenance/ servicing and testing of RO plant including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set and dosing unit complete at so as to supply qualitative water at permissible level of TDS.\nNote:- (a) Spares required for replacement will measured and paid separately under respective items here-in-this schedule. \n(b) The rate quoted by the tenderer includes cost of maint/ servicing of above said plant once in a period of 90 days till the date of completion of work. (c) Rate inclusive of replacement of parts day during currency of contract as and when directed by Engineer-in-Charge. (d) Servicing should be done by OEM/ authorized agency and not by any local mechanic. (e) Contractor shall be produce all purchase voucher and test certificate before submitted RAR. | |||
32 | 31.01 | (a) RO Plant 60 Ltrs capacity at 258 SU/857 SU Gandhinagar. | 6 | EACH JOB | |
33 | 32 | All as per Item No. 31 above, but 50 ltrs capacity. | 3 | EACH JOB | |
34 | 33 | Supply only sediment filter as exiting for 60 Ltr RO plants.\n | 9 | EACH | |
35 | 34 | Supply only sediment filter as existing for 50 ltr RO plants.\n | 4 | EACH | |
36 | 35 | Supply only RO membrane as existing for 50 Ltrs RO plant. \n | 2 | EACH | |
37 | 36 | Supply only RO membrane for as existing 60 Ltrs RO plant.\n | 4 | EACH | |
38 | 37 | Supply and fix RO membrane housing as existing 50/ 60 lts RO plant. | 3 | EACH | |
39 | 38 | S&F carbon filter for 50/60 ltrs RO plant.\n | 3 | EACH | |
40 | 39 | Supply only low pressure /High pressure DC switch for 60/ 50 RO plant. | 2 | EACH | |
41 | 40 | Supply only stainer for 50 Ltrs RO plant. | 1 | EACH | |
42 | 41 | Supply only stainer for 60 Ltrs RO plant. | 1 | EACH | |
43 | 42 | Supply only antiscalant chemical for 50/ 60 ltrs Plant. | 30 | LTR | |
44 | 43 | Supply only solenoid valve for 60/50 ltr RO plant.\n | 3 | EACH | |
45 | 44 | Supply and fix chloroscope (range -0.1 ppm to 2.0 ppm).\n | 1 | EACH | |
46 | 45 | Supply only booster pump 48V DC suitable for50/60 Ltrs RO plant. | 3 | EACH | |
47 | 46 | S&F control module for 50/60 ltr plant. | 2 | EACH | |
48 | 47 | Supply only injection valve up to 7 Kg pressure for chlorine dosing unit. | 1 | EACH | |
49 | 48 | Supply only PVC filter for chlorine dosing unit. | 1 | EACH | |
50 | 49 | Supply only PVC diaphragm with 'O' ring head for chlorine dosing. | 1 | EACH | |
51 | 50 | Supply only suction valve up to 5 ltrs/Hr for chlorine dosing pump. | 1 | EACH | |
52 | 51 | Supply only discharge valve up to 5 Ltrs /Hrs for chlorine dosing pump. | 1 | EACH | |
53 | 52 | Supply only auto level sensor. \n | 3 | EACH | |
54 | 53 | S&F in repairs non return valve suitable for dosing pump. \n\n | 1 | EACH | |
55 | 54 | Dismantling, cleaning and over hauling of 0.25 HP centrifugal mono block pump set/pressure booster pump set of the following capacities including rewinding of motor with appropriate super enameled copper wire of existing gauge, replacement of bearing -02 Nos, including all connection and testing complete for following capacities :-\n(i) Replacement of bush (gland).\n(ii) Replacement of pump shaft.\n(iii) Replacement of impeller.\n(iv) Replacement of shaft sleeve.\nNote:- Suitable for RO plant Monoblock pump only. | 4 | EACH JOB | |
56 | 55 | All as per Item No. 54.00 above, but 1 HP capacity pump complete. | 2 | EACH JOB | |
57 | 56 | S&F in repairs Gun-metal, globe or gate valves of size 15 mm dia with iron wheel head, screwed both ends for iron pipe and fixed. | 15 | EACH | |
58 | 57 | S&F in repairs Gun-metal, globe or gate valves of size 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed. | 10 | EACH | |
59 | 58 | S&F in repairs Gun-metal, globe or gate valves of size 25mm dia with iron wheel head, screwed both ends for iron pipe and fixed. | 10 | EACH | |
60 | 59 | S&F in repairs Gun-metal, globe or gate valves of size 40mm dia with iron wheel head, screwed both ends for iron pipe and fixed. | 5 | EACH | |
61 | 60 | S&F in repairs for Gun-metal, globe or gate valve of size 50mm dia, with iron wheel head, screwed both ends for iron pipe and fixed. | 4 | EACH | |
62 | 61 | S&F in repairs for sluice valve of size 100 mm dia and class PN 1.6, with iron wheel head, screwed both ends GI pipe and fixed. | 1 | EACH | |
63 | 62 | S&F in repairs for sluice valve of size 150 mm dia and class PN 1.6, with iron wheel head, screwed both ends DI pipe and fixed. | 1 | EACH | |
64 | 63 | Fixing only 20 mm dia tubes of medium grade with all fittings to walls and ceilings or laying in floors with all fittings as per site requirement or as directed by EIC.\nNote:- Pipe and fittings will be issued in schedule "B" free for Fixing. | 20 | RM | |
65 | 64 | Fixing only 25 mm dia tubes of medium grade with all fittings to walls and ceilings or laying in floors with all fittings as per site requirement or as directed by EIC. \nNote:- Pipe and fittings will be issued in schedule "B" free for Fixing. | 30 | RM | |
66 | 65 | Fixing only 40 mm dia tubes of medium grade with all fittings to walls and ceilings or laying in floors with all fittings as per site requirement or as directed by EIC \nNote:- Pipe and fittings will be issued in schedule "B" free for Fixing. | 20 | RM | |
67 | 66 | M&L for rectification of leakage from GI 80 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 80 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete.\nNote:- Pipe will be issued under schedule B free for fixingi if required more than 1 metre. | 8 | EACH\nJOB | |
68 | 67 | M&L for rectification of leakage from GI 50 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 50 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete.\nNote:- Pipe will be issued under schedule B free for fixingi if required more than 1 metre. | 8 | EACH\nJOB | |
69 | 68 | M&L for rectification of leakage from GI 40 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 40 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete.\nNote:- Pipe will be issued under schedule B free for fixingi if required more than 1 metre. | 10 | EACH\nJOB | |
70 | 69 | M&L for rectification of leakage from GI 25 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 25 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete.\nNote:- Pipe will be issued under schedule B free for fixingi if required more than 1 metre. | 8 | EACH\nJOB | |
71 | 70 | M&L for rectification of leakage from GI 20 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 20 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete.\nNote:- Pipe will be issued under schedule B free for fixingi if required more than 1 metre. | 8 | EACH\nJOB | |
72 | 71 | M&L for rectification of leakage from GI 15 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 15 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete.\nNote:- Pipe will be issued under schedule B free for fixingi if required more than 1 metre. | 12 | EACH\nJOB | |
73 | 72 | S&F in repairs semi automatic star delta starters in sheet steel enclosure AC-3 duty, 415 V, suitable for 25 HP motor complete all as specified and as directed. | 1 | EACH | |
74 | 73 | S&F in repairs semi automatic star delta starters in sheet steel enclosure AC-3 duty,415 V, suuitable for 45 Hp motor complete all as specified and as directed. | 1 | EACH | |
75 | 74 | S&F in repairs NEON LED lamp with cap & lamp fitting complete for R/Y/B phase indicator in existing panel complete all as specified and as directed. | 4 | EACH | |
76 | 75 | S&F in repairs slector switches for Volt meter, Amp meter with complete accessories fitted on existing panel complete all as specified and as directed. | 4 | EACH | |
77 | 76 | Taking out of old existing unserveceable GI tubing 20 mm dia from the existing surface/floor/trenches/wall/saddeling complete from the existing line all as per site requirement complete all as specified and as directed.\nNote:- Excavation for taking out will be measured and paid separately under relevant item of schedule. | 20 | RM | |
78 | 77 | Taking out of old existing unserveceable GI tubing 25 mm dia from the existing surface/floor/trenches/wall/saddeling complete from the existing line all asper site requirement.\nNote:- Excavation for taking out will be measured and paid separately under relevant item of schedule. | 30 | RM | |
79 | 78 | Taking out of old existing unserveceable GI tubing 40 mm dia from the existing surface/floor/trenches/wall/saddeling complete from the existing line all as per site requirement.\nNote:- Excavation for taking out will be measured and paid separately under relevant item of schedule. | 20 | RM | |
80 | 79 | Cleaning of clear water semi underground sump of capacity 50000 litre at sector-27 pumphouse, by draining out storage water completely with mud pump or throeing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depostting complete all as specified and as directed. | 1 | EACH JOB | |
81 | 80 | Cleaning of RCC overhead reservoir of capacity 50000 gallons at 20 metre staging, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depositing complete all as specified and as directed. | 1 | EACH JOB | |
82 | 81 | Taking out & rewinding the existing unserviceable burnt motor 5/7.5 HP, 3 phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete all as specified and as directed.\nNote:- Before rewinding the existing motor, contractor must show the burnt motor/ winding to the EIC. Old unserviceable copper retrieved will be property of contractor. Rates are inclusive of Old U/s copper winding and u/s spares. | 1 | EACH JOB | |
83 | 82 | All as per Item No. 81 above but of 7.5 HP motor complete. | 1 | EACH JOB | |
84 | 83 | All as per Item No. 81 above but of 10 HP motor complete. | 1 | EACH JOB | |
85 | 84 | S&F 3 layer borosilicate glass tube (58 mm OD,1800 mm length) suitable for tube type solar water heaters complete all as specified and as directed. | 55 | EACH | |
86 | 85 | S&F heat reistance silicon ring (58 mm OD) suitable for tube type solar water heaters complete all as specified and as directed. | 50 | EACH | |
87 | 86 | S&F ABS cover (58 mm OD) suitable for tube type solar water heaters complete all as specified and as directed. | 50 | EACH | |
88 | 87 | S&F EPDM ring (58 mm OD) suitable for tube type solar water heaters complete all as specified and as directed. | 50 | EACH | |
89 | 88 | S&F in repair of 3 KW electric back up heater with thermostat (ISI approved) with pressure release valve 31.75 mm dia complete all as specified and as directed. | 8 | EACH | |
90 | 89 | Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/ loose soil for taking up/ laying cable/pipe etc completed all as apecified and directed. | 378 | CUM | |
91 | 90 | Returning, filling including spreding, leveling watering & well ramming in laying not exc. 25cm for soft/ loose soil complete all as specified and as directed. | 267.422 | CUM | |
92 | 91 | Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for soft/ loose soil complete all as specified and as directed. | 110.578 | CUM | |
93 | 92 | M&L for dry sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and as directed.\nNote:- Thickness after punning will be measured for payment. | 110.565 | CUM | |
94 | 93 | Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc complete all as specified and as directed. | 4.33588 | 1000 NOS | |
95 | 94 | Laying only burnt bricks (old size) retrieved from respective items, laid in trenches as cable protection complete all as specified and as directed. | 2.89059 | 1000 NOS | |
96 | 95 | S&F in repairs of 25 mm bore tube galvanished iron light grade fixed to poles, walls and ceiling etc. with all fittings (clamps for fixing) for protection of cable complete all as specified and as directed. | 12 | RM | |
97 | 96 | Supply and laying in trenches in road cross/ floors tube galvanished iron light grade with all fittings for protection of cable of following dia/ bore of pipe:- | |||
98 | 96.01 | (a) 40mm bore. | 18 | RM | |
99 | 96.02 | (b) 50mm bore. | 12 | RM | |
100 | 97 | Labour only for boring under road/ drain by manual method for inserting the light grade pipe GI tubing up to 50 mm dia cable protection complete all as specified and as directed by Engineer In Charge. | 30 | RM | |
101 | 98 | Supply and lay in replacemet and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 95 Sqmm 3.5 Core complete all as specified and as directed.\nNote:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. | 100 | RM | |
102 | 99 | Supply and lay in replacement and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 35 Sqmm 3.5 Core complete all as specified and as directed.\nNote:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. | 140 | RM | |
103 | 100 | Supply and lay in replacement and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 50 Sqmm 3.5 Core complete all as specified and as directed.\nNote:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. | 130 | RM | |
104 | 101 | Supply and lay in replacement and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 70 Sqmm 3.5 Core complete all as specified and as directed.\nNote:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. | 125 | RM | |
105 | 102 | Supply and laying in replacement XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches/ duct passing through pipe/ duct or fixed on pole and connecting and testing complete all as specified and as directed.\nNote:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. | 150 | RM | |
106 | 103 | Supply and laying in replacement XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches/ duct passing through pipe/ duct or fixed on pole and connecting and testing complete all as specified and as directed.\nNote:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. | 150 | RM | |
107 | 104 | M&L for preparation of old painted surface of steel tubular pole (9/11 meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint, rewriting pole No. by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specified and as directed. | 150 | EACH | |
108 | 105 | Supply and paste fluorescent type reflective tape of superior quality width 450 mm (three strips, each 150 mm wide and 609 mm long of colour white, sky blue, white), paste on steel tubular pole on outer circumferences including removing old tape complete all as specified and as directed. | 150 | EACH | |
109 | 106 | M&L for writting of Pole Nos. on existing pole with stencil out with white colour in sky blue colour background of 80 mm hight around the radius of pole and complete all as specified and as directed by Engr in charge. | 150 | EACH | |
110 | 107 | S&F timer switch Digital type 24 hours with 15 min and 30 min, 16/100 Amp contact rating 230 volts AC 50 Hzs suitable for street lights and all as specified and directed by Engr in charge. \n | 2 | EACH | |
111 | 108 | S&F 3 pole power contactor type ML 3 AC 3 rating (100A) Aux Contactors 2NO+2NC Cat No SS90721 of Make- L&T compatible with digital timer of suitable capacity complete all as specified and as directed by EIC. | 2 | EACH | |
112 | 109 | S&F MCB single pole with neutral, 6 to 32 Amps, 250 volts with ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and as directed. | 5 | EACH | |
113 | 110 | S&F MCB TPN, 32 to 100 Amps, 250 volts with ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and as directed. | 5 | EACH | |
114 | 111 | Disconnecting the existing unserviceable PVC box and Supply and fix PVC box of outside size 350mm x 250mm x 150mm and inside size 300mm x 200mm x 105 mm including 4 Nos. of bus bar strip of aluminium of size 25x4 mm suitable for 440 volts of suitable amps rating including 1 No MCB SPN, 6 to 32 Amps, 250 volts with 'C' curve, to be fixed on pole with clamp complete all as specified and as directed. | 20 | EACH | |
115 | 112 | Dismantling and taking down defective/ unserviceable LED street lights fitting and post top lantern/ gate lights, flood lights of any type and of any description and capacity from 09/11 high electric pole and gates complete all as specified and as directed. | 50 | PER JOB | |
116 | 113 | S&F in replacement 200 Watt LED flood light with pressure die- cast aluminium housing, complete with all accessories, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP : 65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and as directed.\n | 8 | EACH | |
117 | 114 | S&F in repairs LED street light fitting of LSFS-090-C sealed optic luminaire with housing made of die cast aluminium with smooth finish powder coated for better environmental protection complete all as specified below:-\n(i) The fixture shall be designed so as to ave lumen maintenance of at least 70% at the end of 70000 hours.\n(ii) The luminaire should be operable with auto adjustable 120-240 volt supply using the same driver. Ambient temperature at LED should not be more that 70 degree centigrade. \n(iii) Power factor of the electronic driver should be at least 0.90 abd efficiency of the luminaire to be more than 85%.\n(iv) The fixture should be dark sky complaint. The fixture should use aluminium, MCPCB printed circuit boards for better thermal management.\n(v) The luminaire should throw the perfect amount of uniform lught with exactly the desired intensity, and best pole spacing , along with better light control.\n(vi) The luminaire shall employ indivdual optical lens for the each of the LED's to ensure better uniformity of light distribution. \n(vii) The fixute should be vibration resistance, if the fixture is also to be used in vibration prone areas like flyovers/ bridges.\n(viii) Heat dissipation should be managed through a built in external heat sink. \n(ix) Colour rendering index of minimum 65 with color temprature of 4000K.\n | 50 | EACH | |
118 | 115 | Supply only driver of LED light suitable for model - 60 W NEO K complete all as specified and directed by Engr in Charge. | 20 | EACH | |
119 | 116 | M&L for repairing the existing LED Streeet light drivers for light Model 60 W NEO K by taking down the unserviceable LED street light drivers from the street light and repairing/replacing the unserviceable parts of drivers like internal wiring etc and refitting the same with all connection after making serviceable complete all as specified and as directed.\nNote:- Drivers to be paid saperately. | 20 | EACH | |
120 | 117 | S&F in repairs PVC insulated FRLS copper conductor wire of 2 core 1.5 sqmm from existing syntex box to light fitting complete all as specified and as directed. | 100 | RM | |
121 | 118 | Taking down of unserviceable high mast street light fittings of any type, any description and of any capacity upto 16 metre high steel tubular high mast electric pole complete all as specified and as directed. | 8 | EACH | |
122 | 119 | Supply and laying in repairs XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches/ duct passing through pipe/ duct or fixed on pole and connecting and testing complete all as specified and as directed.\nNote:- Excavation/ earthwork, will be measured and paid separately under respective items of this Schedule. | 100 | RM | |
123 | 120 | M&L for earthing complete in repairs with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to GI strip of size 25x4 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit with RCC pit cover charcoal salt, funnel complete all as shown in the electrical plate No. 3 of SSR part - I and tested on completion complete all as specified and as directed. | 2 | EACH\nSET | |
124 | 121 | Disconnecting the existing unserviceable MCCB from the cable of 315-400 A Capacity, taking out from the panel board and supply and fix new MCCB triple pole of 315-400 Amps, 35 to 50 KA breaking capacity as per site requrement, exiting capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and as directed.\n | 2 | EACH | |
125 | 122 | Disconnecting the existing unserviceable MCCB from the cable of 160 -250 A Capacity, taking out from the panel board and supply and fix new MCCB triple pole of 160-250 Amps, 25 to 35 KA breaking capacity as per site requrement,exiting capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and as directed.\n | 4 | EACH | |
126 | 123 | Disconnecting the existing unserviceable MCCB from the cable of 160 -250 A Capacity, taking out from the panel board and supply and fix new MCCB triple pole of 63-100 Amps, 25 to 35 KA breaking capacity as per site requrement, exiting capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and as directed. | 5 | EACH | |
127 | 124 | S&F pad locks 7 Leaver for all LT Panels and making locking arrangements for the E/M Equipments including all welding works required for making the handles/ clamps complete all as specified and directed by EIC. \nNote:- Material used for making the locking arrangements like handles/ clamps will be provided by the contractor at no additional cost. | 4 | EACH | |
128 | 125 | Supply only aggregate for loose filling of gauge 80 mm to 150 mm graded at electric supply sub stations at AF Stn Chiloda complete all as specified and as directed. | 20 | CUM | |
129 | 126 | M&L for preparation of old painted surface of electrical panel inner and outer surface complete of size length (0.5 m to 1 m), Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing with iron brush and applying two coats of synthetic enamal paint with spray machine complete all as specified and as directed. | 4 | EACH JOB | |
130 | 127 | M&L for preparation of old painted surface of electrical panel inner and outer surface complete of size length (1 m to 2 m), Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing with iron brush and applying two coats of synthetic enamal paint with spray machine complete all as specified and as directed. | 2 | EACH JOB | |
131 | 128 | S&F Glow sign board of size 1.5 m x 0.9 m x 0.20 m made out of 1.0 mm thick tin sheet all side except front side aluminium beading "L" shape at all boarder exterier and interier side, front should be acrylic cover 2.0 mm thick of blue colour and written the subject matter as given by the Engr-in-charge in english capital letter in white colour with twin tubelight fitting 1x28 watt (2 nos) including all electrical connection with surface conduit wiring 1.5 Sqmm ((length not exceeding 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing complete all as specified and as directed. | 1 | EACH | |
132 | 129 | S&F LED Spot light fitted schematic layout daigram of external E/M Services at the station of size 2.0 m x1.5 m x 0.20 m made out of 10.0 mm thick hard board sheet all side except front side aluminium beading "L" shape at all boarder exterier and interier side, front should be acrylic transparent cover 3.0 mm thick showing the schematic layout daigram of external E/M services given by the Engr-in-charge, fitted with LED spot light fittings of sufficeint wattage along the lines of layout plan including all electrical connection with surface conduit wiring 1.5 Sqmm (length not exceeding 8 meter) copper wire with drilling and all abbreviations should be written in english capital letter in black colour, necessary arrangement required for fixing of board should be made by the contractor at no additional cost complete all as specified and as directed. | 1 | EACH | |
133 | 130 | S&F in repairs cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 120 Sqmm 3.5 core complete all as specified and as directed. | 2 | EACH | |
134 | 131 | S&F in repairs cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 95 Sqmm 3.5 core complete all as specified and as directed. | 2 | EACH | |
135 | 132 | S&F in repairs cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 70 Sqmm 3.5 core complete all as specified and as directed. | 2 | EACH | |
136 | 133 | S&F in repairs cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 50 Sqmm 3.5 core complete all as specified and as directed. | 4 | EACH | |
137 | 134 | S&F in repairs cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 35 Sqmm 3.5 core complete all as specified and as directed. | 4 | EACH | |
138 | 135 | S&F in repairs cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 25 Sqmm 4 core complete all as specified and as directed. | 4 | EACH | |
139 | 136 | S&F in repairs cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 10 Sqmm 2 core complete all as specified and as directed. | 2 | EACH | |
140 | 137 | Comprehensive Maintenance/ Servicing of existing RMU's SF 6, 3 phase, 11 KV, 630/ 400 Amps by authorised dealer only.The scope of work includes:-\n(a) Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr in charge. The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/ resetting required.\n(b) Checking of all incoming and outgoing HT Terminals for any looseness and ensuring the proper tightness for all terminals. \n(c) Checking the nominsl operating gas presssure as per manufactures standard of RMU and testing for any leakage of insulation gas and rectify the same if found (d) Operating gas pressure should be suitable to satisfy the rated dielectric strength (e) Testing for CT's, PT's, Relays , Breakers and cable glands \n(f) Anti oxide greasing should be done at all connections of cable and bus bars \n | 1 | EACH | |
141 | 137.01 | Note:- (1) The contractor should ensure the proper functioning of RMU's and should approach with authorised dealer for carrying of servicing of breaker periodically & when fault /breakdown occurs. \n(2) Contractor shall produce all purchase voucher and test certificate before submitting the RAR.\n(3) The contractor will be responsible for serviceability of RMU's for the entire contract period\n(4) Unserviceable Spare Part will be paid and measured separately under respective items of schedule. | |||
142 | 138 | Servicing of transformer upto 500 KVA/250 KVA at carrying out insulation resistant test(HT-LT,HT-E & LT-E), BDV of Oil (top & bottom sample), Filtration & topping up of oil, test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals& joints,replacement of loose or burnt out gasket & proper sealing of valves etc as directed by Engineer-in-Charge. | 2 | EACH | |
143 | 138.01 | Notes:- \n(i)The cost involved for oil filtration & topping with new mineral oil will be measured & paid separately.\n(ii) The contractor should produce all testing certificates immediately after testing. Moreover testing should be carried out by authorized OEM only\n(iii) The contracted labour manning the substation should immediately inform any oil leakage, change in colour of silica gel, level down of oil in conservator etc. | |||
144 | 139 | Dehydration/ filtration of transformer oil of transformers, of various capacities installed in different locations under GE ( AF ) chiloda, by recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength is up to 40 KV to 50 KV.\nNote:- Quoted rates shall be deem to include for following:-\n(i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil.\n(ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.\n(iii) Transformer oil will be issued under Sch ‘B’ free for topping up. | 500 | LTRS | |
145 | 140 | S&F in repairs electrical insulation matts, Classs "A" width 1 Mtr, thickness 2.0 mm working grade 3.3 KV, Breakdown voltage: 30 KV, all other specification confirming to IS : 15652-2006, ISI market, synthetic mats, fire retardant, blue/ black in colour complete all as specified and as directed.\n | 10 | SQMM | |
146 | 141 | S&F in replacement worn out HT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leakage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed. | 2 | EACH | |
147 | 142 | S&F in replacement worn out LT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leackage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed. | 2 | EACH | |
148 | 143 | S&F in replacement breather with accessories of transformer as existing including silca jel complete all as specified and as directed. | 2 | EACH | |
149 | 144 | M&L for colour coding of earthing pit cover with the following colors: Red for chemical earth pit & yellow for conventional earth pit.The numbering/marking of earth pit will be in capital black colour & is to be done as directed by Engineer-in-charge. | 30 | EACH | |
150 | 145 | M&L for construction of earthing chamber internal size 600 x 600 x 600 mm in repairs and making coping for funnel with PCC (1:2:4) type B1 using 20mm graded stone aggregate all with MS Angle 40x40x4mm frame work duly painted with all corrosive bituminous paint and including RCC slab 50 mm thick in cement concrete (1:2:4) type B1 reinforced with XPM (weight not less than 3 Kg per Sqm) having lifting arrangement including dismantling old earthing chamber complete all as specified and as directed. | 5 | EACH | |
151 | 146 | Repairs/ servicing to 250 KVA DG set (Make- Greaves) including radiator servicing, intercooler servicing, general maintenance work such as belt, valve clearance, hose pipe set, bearing greasing connection of terminal ,replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality, and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed by Engineer-in-charge.\n\n\n\n\n | 1 | EACH JOB | |
152 | 147 | Fuel filter - 01 Set. | 1 | EACH SET | |
153 | 148 | Oil filter (Spinon/ Centrifugal type) - 01 Set. | 1 | EACH SET | |
154 | 149 | Air filter - 01 Set. | 1 | EACH SET | |
155 | 150 | Engine oil - 30 Ltrs. | 30 | LTRS | |
156 | 151 | Coolant - 4 ltrs. | 4 | LTRS | |
157 | 152 | Replacement of Door lock for canopy - 04 Nos. | 4 | NOS | |
158 | 153 | Repairs/ servicing to 75 KVA DG set (Make- Greaves) including radiator servicing, intercooler servicing, general maintenance work such as belt, valve clearance, hose pipe set, bearing greasing connection of terminal, replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed by Engineer-in-charge.\n\n\n\n\n | 1 | EACH JOB | |
159 | 154 | Fuel filter - 01 Set. | 1 | EACH SET | |
160 | 155 | Oil filter (Spinon/Centrifugal type) - 01 Set. | 1 | EACH SET | |
161 | 156 | Air filter - 01 Set. | 1 | EACH SET | |
162 | 157 | Engine oil - 20 Ltrs. | 20 | LTRS | |
163 | 158 | Coolant - 4 ltrs. | 4 | LTRS | |
164 | 159 | Replacement of Door lock for canopy - 04 Nos. | 4 | NOS | |
165 | 160 | Repairs/ servicing to 10 KVA DG set (Make - Mahindra and mahindra) including radiator servicing, intercooler servicing, general maintenance work such as belt, valve clearance, hose pipe set, bearing greasing connection of terminal, replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed by Engineer-in-charge.\n\n\n\n\n | 1 | EACH JOB | |
166 | 161 | Fuel filter - 01 Set. | 1 | EACH SET | |
167 | 162 | Oil filter (Spinon/Centrifugal type) - 01 Set. | 1 | EACH SET | |
168 | 163 | Air filter - 01 Set. | 1 | EACH SET | |
169 | 164 | Engine oil - 13 Ltrs. | 13 | LTRS | |
170 | 165 | Coolant - 2 ltrs. | 2 | LTRS | |
171 | 166 | Replacement of Door lock for canopy - 04 Nos. | 4 | NOS | |
172 | 167 | Supply & fix in replacement of Exide battery 12 volt, 130AH.\n | 3 | EACH | |
173 | 168 | Supply and fix in replacement copper lead fixed with terminal lugs for 12V lead acid battery. \n | 2 | EACH | |
174 | 169 | M&L for Servicing of Servo controlled voltage stabilizer 200 KVA, 415 Volt including setting of Input and Output voltage complete all as specified and as directed.\nNote:- Spare required for replacement if any will be measured and paid separately. | 1 | EACH | |
175 | 170 | M&L for filtration of oil for voltage stabilizer & alike filled at various electrical equipment installed at HQ SWAC at AF Stn Chiloda with filtration machine to achieve dielectric strength 40 to 50 KV per 2 minutes gap as per IS specification complete all as specified and as directed. | 50 | LITRS | |
176 | 171 | M&L for topping up of voltage stabilizer oil having dielectric strength 50 KV or so, as per IS specification in various electrical equipment installed at HQ SWAC at AF Station chiloda as required & directed. \n | 10 | LITRS | |
177 | 171.01 | Notes for item Nos. 170 & 171 1. Labour for draining out of oil & refilling the same is deemed to be included in quoted rates. \n2. Cost of minor spares ie nut bolt and washer if required to complete the job is deemed to be included in quoted rates. | |||
178 | 172 | Supply only following spares for servo controlled voltage stabilizer of 200 KVA:- | |||
179 | 172.01 | Shunt trip coil of any size. | 1 | EACH | |
180 | 172.02 | Cut out PCB, 3 phase. | 1 | EACH | |
181 | 172.03 | Control PCB. | 1 | EACH | |
182 | 172.04 | Control wire. | 1 | EACH | |
183 | 172.05 | RC network for 10 KG motor. | 1 | EACH | |
184 | 172.06 | Sensing transformer for analog control. | 1 | EACH | |
185 | 172.07 | Stabiliser carbon Brush for Dimmer. | 1 | EACH | |
186 | 172.08 | Control wire with glass fuse. | 1 | EACH | |
187 | 173 | S&F in repairs digital voltmeter 0-500 volts of size 96x96mm complete all as specified and directed by Engr-in-Charge. \n | 6 | EACH | |
188 | 174 | S&F in repairs digital Ampere meter 0-500 A of size 96x96mm complete all as specified and directed by Engr in Charge. \n | 6 | EACH | |
189 | 175 | Repairs maintenance of APFC panel of capacity 90 KVAR to 250 KVAR including replacement of wiring with copper conductor cable with lugs etc calibration of relay, digital meter including testing complete all as specified and as directed.\nNote:- Unserviceable Spare Part will be paid and measured separately under respective items. | 2 | EACH | |
190 | 176 | S&F in repair Red/ Yellow/ Blue LED indicating lamp (Set of three lamp), 240 volts, AC complete all as specified and as directed. | 4 | EACH | |
191 | 177 | S&F in repairs Red luminous push button with LED indicating lamp and 1NC Element complete all as specified and directed by Engr in Charge. \n | 5 | EACH | |
192 | 178 | S&F in repairs green luminous push button with LED indicating lamp and 1 NC Element complete all as specified and as directed by Engr in Charge. \n | 5 | EACH | |
193 | 179 | S&F in repairs 25 KVAR capacitor duty contactor, 240 volts, AC coil complete all as specified and as directed by Engr-in-Charge. | 2 | EACH | |
194 | 180 | S&F in repairs 25 KVAR cylindrical capacitor, 440 volts, 3 phase, 50 Hz complete all as specified and as directed by Engr-in-Charge. | 2 | EACH | |
195 | 181 | Taking out U/S LT underground cable of any size 1100 volt grade & bricks, tracing out the defects, rectify the same, making servicable by removing/ cutting U/S & burnt out part, jointing with straight through joint of suitable size, testing with megger etc including all associated earth work like excavation/ returning filling/ removal excavated material and sand filling all as specified and directed by Eng-In-Charge. (Straight through joints will be measured and paid separately.) | 500 | RM | |
196 | 182 | Relaying of serviceable LT cable retrieved from Item No 181 after cutting into pieces serviceable portion of following Sizes including all associated earth work like excavation/ returning filling/ removal excavated material and sand filling complete all as specified and as directed by Eng-In-Charge. | 500 | RM | |
197 | 183 | Taking out u/s HT underground cable of any size (3x95 Sqmm ) 11000 volt grade & bricks, tracing out the defects, rectify the same, making servicable by removing/ cutting U/S & burnt out part jointing with straight through joint of suitable size, testing with megger etc including all associated earth work like excavation/returning filling/removal excavated material and sand filling all as specified and directed by Eng-In-Charge. (Straight through joints will be measured and paid separately.) | 50 | RM | |
198 | 184 | Relaying of serviceable HT cable retrieved from Item No. 183 after cutting into pieces serviceable portion including all associated earth work like excavation/ returning filling/ removal excavated material and sand filling complete all as specified and as directed by Eng-In-Charge. | 50 | RM | |
199 | 185 | Supply and lay in repairs and testing cable HT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 95 Sqmm 3 Core complete all as specified and as directed.\nNote:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. | 20 | RM | |
200 | 186 | S&F in repairs cable jointing kit for 11000 volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm 3 core complete all as specified and as directed. | 2 | EACH | |
201 | 187 | S&F in repairs cable jointing kit for 11000 volts grade cable for outdoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm 3 core complete all as specified and as directed. | 2 | EACH | |
202 | 188 | S&F in repairs cable jointing kit for 11000 volts grade cable for Indoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm 3 core complete all as specified and as directed. | 1 | EACH |