Supplying And Fixing Of Led Street Lights With New Lt Poles And Lighting In Covered Platform In Sub Yard Kapren Under Kums Keshoraipatan Distt . Bundi, Bundi-Rajasthan

Rajasthan State Agricultural Marketing Board-RSAMB has published Supplying And Fixing Of Led Street Lights With New Lt Poles And Lighting In Covered Platform In Sub Yard Kapren Under Kums Keshoraipatan Distt . Bundi. Submission Date for this Tender is 26-10-2020. Electrification Work Tenders in Bundi Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

25742251
Supplying And Fixing Of Led Street Lights With New Lt Poles And Lighting In Covered Platform In Sub Yard Kapren Under Kums Keshoraipatan Distt . Bundi
Open Tender
Indian
Rajasthan
Bundi
26-10-2020

Tender Details

Supplying And Fixing Of Led Street Lights With New Lt Poles And Lighting In Covered Platform In Sub Yard Kapren Under Kums Keshoraipatan Distt . Bundi

Key Value

Document Fees
INR 500 /-
EMD
INR 6170.0 /-
Tender Value
INR 6.17 Lakhs /-

BOQ Items

Name of Work: Supplying and Fixing of LED street lights with new LT poles and lighting in covered platform in sub yard Kapren under KUMS Keshoraipatan Distt. Bundi
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply and erection of P.C.C./R.C.C. pole as per REC manual no 15/1979 conforming to IS: 2905/1966 including excavation of pit and back filling with stone aggregate/boulders and soil in 0.45m consolidating each deposited layer of 0.45m by ramming and watering etc complete in all respect.
2 1.01 9.0 Mtr long (200 Kg ) as per Discom specification 16 Each
3 2 P & F of IP 65 protected High Power LED Flood Light System with pressure die cast aluminium housing, toughened glass diffuser with suitable lenses on LEDs to acheive various beam angles. 240 volt, 50Hz, of high power LED fixure supplied with pre wired cable of 1 mtr. Integreted driver shell be efficiecy having effciency more than 85% and in complience to IEC standards/BIS cirtified the system level Luminaire efficacy >=100 with high power LEDs of CREE /Nichia/Osram/ Philips/ SEOUL make is to be used. LED driver input voltage AC 110 to 270 V AC with auto restting Sagety Cut-off, Input Frequency 50Hz+3% Power Factor >0.95 Driver Efficiency >85%, Control Gear Integral Design, THD(1) <10%, Electrical Connector Must be provided Surge Protection Mir. >=5KV internal and 10KV external in 80W onwards, Humidity 10% to 90% RH Working Temp -20C to 50C. LED Luminaire Specifications: Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintenance. Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life of fixture. Fixtures shall be CE complianed. (Gr-1)
4 2.01 High Power LED Flood Light 60W 20 Each
5 3 P&F of IP65 protected LED Street Light Luminaire on existing bracket. Fixture made of powder coated single piece pressure die cast aluminum with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover t f from 45W onwards I and should be secondary lens on each LED The System level Luminaire efficacy >=100 with High Power LEDs of I cREE/NrCH tA/ OSRAM/PHrLrps/sEouLI make is to be used .The LED Driver I shall be BIS certified and Inpur Voltage I AC 1 10 to 27 0 V AC wirh Inpur I Frequency 50Hzt 3o/o Power Factor I >0.95 Driver Efficiency >BSo/a, THDtll I <1,A0/o Humidity l0o/o to 900/o RH I Working Temp -20C to 50C Life I Expectancy Equal or more than 50000 I burning hrs with Minimum 700/o initial I lumens maintained ,Rendering Index I >75% .Surge protection shall be min > 5 I KV internal and min 10 KV external. I Manufactures Word Mark/Name I Engraved/Embossed on die cast housing to allow traceability/authenticiry till life of fixture. Fixtures shall be CE complianed. (GROUP-I)
6 3.01 LED Street Light fixture 90 Watt 18 Each
7 4 Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes.
8 4.01 With Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating
9 4.02 GI pipe 2000 mm long, 50 / 25mm, Terminal 12 mm GI Strip 2 Set
10 5 S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
11 5.01 8 SWG G.I. ( Hot Dipped ) Wire 480 Mtr.
12 5.02 20mm x 3mm G.I. ( Hot Dipped ) Strip 20 Mtr.
13 6 Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) duly crimped with crimping tool, PVC tape etc of following size.(GROUP-I)
14 6.01 10.0 Sq.mm 16 Each
15 6.02 25.0 Sq.mm 16 Each
16 7 P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.(GROUP-I)
17 7.01 10.0 Sq.mm
18 7.02 2 core 190 Mtr.
19 7.03 25.0 Sq.mm
20 7.04 3.5 core 150 Mtr.
21 8 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs / spreaders, etc. as required.(GROUP-I)
22 8.01 With Thermal Magnetic release
23 8.02 up to 100 Amp , 10 kA, fixed O/L & S/C setting 2 Each
24 9 P & F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.(Group-1)
25 9.01 4 pole Power contactors with following AC 1 Rating
26 9.02 63 Amp 2 Each
27 10 P&F of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming etc. as required.(Group-1)
28 10.01 One day & week reserve (digital type ) 2 Each
29 11 S & F of Street light bracket made out from following size of ' B ' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required.
30 11.01 32 mm Dia. 18 Each
31 12 P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.(Group-1)
32 12.01 Single pole MCB
33 12.02 6 A to 32 A rating 20 Each
34 13 Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required as per Discom specification.
35 13.01 50 Sqmm of (6+1) 3.35 mm (Insulated Rabbit) 2300 Mtr.
36 13.02 30 Sqmm of (6+1) 2.59mm (Weasel)(LR only) 800 Mtr.
37 14 Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications.
38 14.01 LT cross arm 600 mm long with clamp 14 Each
39 14.02 LT cross arm 1200 mm long with clamp 17 Each
40 15 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 suitable for working voltage 1100 volts including all accessories like hot dip GI forged spindle of 260mm long and nuts etc as reqd as per Discom specification.
41 15.01 105mm x 80mm 70 Each
42 16 Supply and fixing of porcelain shackle insulator as per IS:1443 1979 suitable for working on 1100 volts including hot dipped GI accessories and heavy duty hardwares etc as required as per Discom specification.
43 16.01 100mm x 110mm 45 Each
44 17 Supply and erection of GI stay set as per Discom specification complete with long stay rod with anchor plate including stay clamps turn buckle and G.I stay wire tightened through strain insulator, in cement concrete 1:3:6 including excavation of pit-re-filling etc as reqd.
45 17.01 Stay set of dia 20mm,2.4m long stay rod and anchor plate 380x380x6.4mm 5 Each
46 18 P&F weather proof pillar box of required size of 16 gauge M.S. sheet made out of angle iron 35x35x5mm for top and bottom frame and four nos. angle for legs. Two angle and two flat iron of size 35x35x5mm and 37mmx5mm respectively for support of sheet or plank as approved design with openable door on both sides made out of angle iron 25x25x4mm with EL drop steel handle and panel lock duly painted with red oxide paint & two coats of gray/aluminum paint of approved quality including fixing of legs in padestal made of 23cm thick mosonry wall required internal size plastered with cement sand mortar 1:4 as per approved design having inspection window size 0.60mx0.45m size 0.60x0.45m fabricated with M.S. angle 25x25x4mm duly covered with 16 gauge M.S. sheet complete in all respect.
47 18.01 (B) Size 0.95.mx0.65mx1.30m ht with masonry wall of internal size 0.90mx0.65mx1.0mht. 2 Each
48 19 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required.(Group-1)
49 19.01 25 mm 160 R. mtr.
50 19.02 32 mm 60 R. mtr.
51 20 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
52 20.01 2 x 2.5 sq.mm 280 Mtr.
53 21 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.(Group-I)
54 21.01 Double door (single phase)
55 21.02 12 Way 2 Each
56 22 P&F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board / sheet including making connections, testing etc. as required.(Group-I)
57 22.01 Double pole isolator
58 22.02 63 A rating 2 Each
59 23 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required.
60 23.01 6.4 mm thick 2.2 Sq.m
61 24 P&F following size aluminium bus bar on insulators at approved spacing in existing bus bar chamber including making holes etc. as required\n
62 24.01 30 x 5 mm 4 Mtr.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail