Military Engineer Services-MES has published Repair To Flooring , Plastering , Joinery , Plumbing And Sanitory Fitting At Or Md Accn At Fafa Complex Under Ge ( East ) , Mathura. Submission Date for this Tender is 05-11-2020. Civil Work Tenders in GE (EAST), MATHURA Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR TO FLOORING, PLASTERING, JOINERY, PLUMBING AND SANITORY FITTING AT OR MD ACCN AT FAFA COMPLEX UNDER GE (EAST), MATHURA | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Qty | Units | |
1 | 1 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints,hacking for key, scrubbing down with water, etc. | 375 | Sqm | |
2 | 2 | M&L for 15mm thick plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement. | 200 | Sqm | |
3 | 3 | M&L for rendering 10 mm thick in CM 1:4 on ceiling surfaces and finished surface even & smooth all as specified. | 100 | Sqm | |
4 | 4 | M&L rendering 15mm thick (10mm + 5mm) plaster on fair face of brick work in CM 1:4 and surface finished even and fair by mixing integral water proofing compound in finishing coat as per manufacturers instructions complete. \nNote :- WPC shall be measured & paid seprately under relevant item of this BOQ. | 75 | Sqm | |
5 | 5 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. | 75 | Sqm | |
6 | 6 | M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper over a coat of Alkali resistant primer over a coat of wall care putty not less than 1mm thick complete all as specified and as directed. | 200 | Sqm | |
7 | 7 | M&L for preparation of newly plastered surface of walls and applying two coat of white wash complete all as specified and directed. | 100 | Sqm | |
8 | 8 | S&F in repairs 25mm dia stainless steel pipe of grade 304 as in curtain rod including pair of decorative stainless steel brackets and knobs fixed to walls with screws as per sample approved by GE. | 200 | RM | |
9 | 9 | M&L for preparing old plastered surfaces of walls/ceilings and applying one coat of weather proof acrylic exterior paint (100% Acrylic) with spray machine, spray hard to reached area to achieve excellent application using limited manpower including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.\nNote :- \n(i) Weather proof acrylic exterior paint shall be applied machincally by latest machine such as trucare Graco or equivalent having minimum pressure of 3300 PSI. | 2850 | Sqm | |
10 | 10 | M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper complete all as specified and directed. | 500 | Sqm | |
11 | 11 | M&L for preparing newly plastered surface of walls and applying one coats of white wash complete all as specified. | 2000 | Sqm | |
12 | 12 | M&L for preparing newly plastered surface of ceiling and applying one coats of white wash complete all as specified. | 400 | Sqm | |
13 | 13 | M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed. | 500 | Sqm | |
14 | 14 | M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. | 200 | Sqm | |
15 | 15 | M&L for preparation of old steel surfaces any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified. | 400 | Sqm | |
16 | 16 | M&L for preparation of old steel surfaces any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified. | 100 | Sqm | |
17 | 17 | S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples. | 100 | Sqm | |
18 | 18 | S&F in repair 3mm thick frosted glass ordinary quality and glazing with oil putty in Sqm n.exc 0.50 Sqm in each pane complete. | 25 | Sqm | |
19 | 19 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises | 296 | Sqm | |
20 | 20 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level). | 2.5 | Cum | |
21 | 21 | M&L for providing 25mm thick M-15 grade (Nominal mix) using 20mm graded stone aggregate as in floor finish complete. | 100 | Sqm | |
22 | 22 | S&F coloured, non skid ceramic tiles 7 to 8 mm thick (square/ rectangular ) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm ,in floors etc . set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl screed bed or bedding layer of mortar 15 mm thick for laying floor finished use CM 1:4 all as specified. | 100 | Sqm | |
23 | 23 | All as per item No 22 here-in-before but as in skirting/dado over 10mm thick cement plaster in CM 1:3 as in backing coat as specified and directed by Engr-in-Charge. | 16 | Sqm | |
24 | 24 | M&L for Glazed ceramic tiles in vertical surface 300x200x7mm/450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing coat of cement mortar in 1:3 complete all as specified. | 180 | Sqm | |
25 | 25 | S&F vitreous china wash hand basin,white, flat back size 580x450 mm excluding taps, waste chain & plug & porcelein stopper but including brackets 32 mm bore waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement cutting for and pinning in ends of brackets all as specified and directed. \n | 5 | Each | |
26 | 26 | S&F in repairs PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float handle including fixing brackets and 32mm bore PVC flush pipe etc complete all as specified and directed. | 10 | Each | |
27 | 27 | Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. | 95 | RM | |
28 | 28 | Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed | 75 | RM | |
29 | 29 | Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc for 15mm dia complete all as specified and directed. | 20 | RM | |
30 | 30 | Taking up or down 20mm dia steel tubing and connections including disconnection of fitting and cleaning for refixing where required complete all as specified and direcred. | 120 | RM | |
31 | 31 | Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc for 20mm dia complete all as specified and directed. | 10 | RM | |
32 | 32 | Supplying & fixing to walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. | 110 | RM | |
33 | 33 | M&L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps,cills, sunshades, shelves,lintels,etc; and cutting chases for concealed water tubing etc, and making, cutting not exc10 cm girth. | 60 | RM | |
34 | 34 | S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. | 5 | Each | |
35 | 35 | S&F 15 mm bore fancy type Chromium plated stop valve cast copper alloy scap screwed one ends to iron pipe or for unions and other end by PVC connection all as specified. | 20 | Each | |
36 | 36 | S&F in repairs 15mm bore pillar taps fancy type cast copper alloy with capestan heads chromium plated screwed down high pressure with hot & cold with long screwed shanks and fly nuts all as specified and directed. | 15 | Each | |
37 | 37 | S&F in repair 15mm bore fancy type bib taps chromium plated cast copper alloy with crutch or butter fly handle screwed down, screwed for iron pipe complete. | 25 | Each | |
38 | 38 | S&F in repairs Brass chromium plated shower rose 75mm size fixed to GI tubing and to Shower complete. | 20 | Each | |
39 | 39 | S&F in repairs bathroom cabinet mirror (of approved pattern) of size 450mmx350mm regular size with mirror and PVC shelves complete all as specified and directed by Engineer-in-Charge. | 10 | Each | |
40 | 40 | S&F 500 litre capacity triple layer ISI Marked rotational moulded polyethylene water storage tank (cylindrical vertical with closed top)hoisted and fixed in position including making inlet/oulet connection and fitting tank connection complete all as specified and as directed. | 3 | Each | |
41 | 41 | S&F in repair 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete. (Minimum weight 20mm-210gms). | 21 | Each | |
42 | 42 | S&F 110 mm dia PVC (SWR) pipes type 'A' single socketed in any length with rubber ring joints laid in trenches. | 11 | RM | |
43 | 43 | S&F 75 mm dia PVC (SWR) pipes single type 'A' socketed in any length with rubber ring joints laid in trenches. | 11 | RM | |
44 | 44 | S&F PVC (SWR) 110 mm dia bends any radious all as specified and directed. | 5 | Each | |
45 | 45 | S&F PVC (SWR) 75 mm dia bends any radious all as specified and directed. | 5 | Each | |
46 | 46 | S&F in repair PVC (SWR) branch piece, single (single Y) equal or unequal for 110mm dia pipe complete all as specified and directed. | 5 | Each | |
47 | 47 | S&F in repair PVC (SWR) branch piece, single (single Y) equal or unequal for 75mm dia pipe complete all as specified and directed. | 5 | Each | |
48 | 48 | S&F in repair 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified. | 5 | Each | |
49 | 49 | S&F in repair 75 mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified. | 5 | Each | |
50 | 50 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but not exc 4 sq. m each | 210 | Each | |
51 | 51 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each | 16 | Each | |
52 | 52 | Taking down shutters of any description exc 1.00 Sqm and n. exc 2.00 Sqm each. | 11 | Each | |
53 | 53 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position | 57.2 | RM | |
54 | 54 | S&F 125x60 mm Pressed steel frames made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with one shop coat of red oxide primer complete, as specified, supplied and fixed all as specified and as directed. | 31.2 | RM | |
55 | 55 | Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement concrete M-15 grade (Nominal mix) using 20mm graded stone aggregate as required depth of embedded portion of holdfast or lugsmeasured from the face of jamb into the wall - exc. halfbrick but n exc. one brick | 66 | Each | |
56 | 56 | M&L for cement concrete M-10 grade (Nominal Mix) using 12.50mm graded stone aggregate for filling in pressed steel door frames all as specified and directed. | 0.43 | Cum | |
57 | 57 | S&F 40 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides. | 30.6 | Sqm | |
58 | 58 | S&F 35mm thick second class HW glazed and gauged skeleton shutters open rebeted and prepared to receive glass, guaze etc (without sash bar) edges of framing plain chamfered or rounded fitted with cut and beads for securing glass, gauge etc size of shutters as specified in SSR Part-I section & clause 8.20(a). | 27 | Sqm | |
59 | 59 | M&L for preparation of new wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-charge. | 61.2 | Sqm | |
60 | 60 | M&L for preparation of new steel surfaces over 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamal paint over a coat of red oxide primer complete. | 43.2 | Sqm | |
61 | 61 | M&L for prepration of new primed steel surfaces, exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chromate primer all as specified and as directed by Engineer-In-Charge. | 8.29 | Sqm | |
62 | 62 | S&F 125 mm long extruded aluminium alloy handles, fabricated type anodized complete. | 64 | Each | |
63 | 63 | S&F for 100 mm aluminium anodised barrel tower bolts of extruded section and fixed. | 64 | Each | |
64 | 64 | S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. | 17 | Each | |
65 | 65 | Supply and fix Stainless steel wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples | 9.9 | Sqm | |
66 | 66 | Supply and fix 150mm length, floor door stopper of brass body, fixe in repairs complete all as specified and directed. | 22 | Each | |
67 | 67 | S&F100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed . | 30 | Each | |
68 | 68 | S&F solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforcement with MS square tube supplying and fixing in opening as per specification & sketch shown in sketch 8 of SSR part II. | 48 | RM | |
69 | 69 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck indie with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fittied in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. | 14 | Sqm | |
70 | 70 | S&F aluminium powder coated window sliding type (3 rack) with frame size 100x35x1.2mm and shutter 39.40x17.70x1.2mm with low glass shutter & one complete all as specified and directed. | 7.2 | Sqm | |
71 | 71 | S&F aluminium louvered ventilators of section size 100mmx25mmx1.50mm including frosted glass fixed in half protion & adjustable type louvers in another hald and stainless steel wire mesh fixed type on outside frame etc. including taking down existing steel ventilator all as directed by Engr-in-charge | 6 | Sqm | |
72 | 72 | Taking down aluminium/copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc, removing materials to store for keeping in safe custody or for taking credit and making good to the disturbed surfaces of walls, ceilings and floors etc complete all as direct. \nNote: Credit of aboe item should be incl i the point as per credit schedule. | 64 | Per Point | |
73 | 73 | Taking down carefully by Submain wiring/ service connection of any type complete all as directed by Engineer-in-Charge.\n | 50 | RM | |
74 | 74 | M&L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed FRLS cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia medium grade) and its all accessories complete concealed in wall / roof incl cutting & chases( making good all to the disturbed surfaces as per existing) etc including earth wire of PVC insulated FRLS copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified in current SSR Part-I & II & directed by the Engineer-in-Charge, as described below:- | |||
75 | 74.01 | One light point controlled by one way switch 5 amp complete. | 32 | Per Point | |
76 | 74.02 | One ceiling fan point controlled by one way switch 5 Amp and one regulator complete. | 6 | Per Point | |
77 | 74.03 | One exhaust fanf point controlled by one way switch 5 Amp complete. | 4 | Per Point | |
78 | 74.04 | One 3 pin 5 Amp socket point controlled by one switch on same board. | 6 | Per Point | |
79 | 74.05 | One 3 pin 5 Amps socket point controlled by one switch on independent board. | 6 | Per Point | |
80 | 74.06 | One bell point controlled by one push button on independent board. | 2 | Per Point | |
81 | 74.07 | One light point controlled by two way switches 5 Amp complete. | 2 | Per Point | |
82 | 75 | All as per item No. 75 but for 3 pin / 5 pin 16 Amps sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent complete all as specified and as directed . | 6 | Per Point | |
83 | 76 | M&L for submain wiring with Two runs of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor FRLS PVC insulated unsheathed cables conforming to IS : 694 drawn through and including concealed in wall rigid medium duty unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and accessorie all conforming to IS specification complete.\nNote :- Two run of 4 Sqmm, one run of 4 sqmm earth wire and one run of PVC conduit shall be measured as one unit length. | 50 | RM | |
84 | 77 | Supply and Fixing ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified. | 37 | Each | |
85 | 78 | Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete all as specified. | 54 | Each | |
86 | 79 | Supply and Fixing Modular switch 6 Amps single pole two-way, 1 Module complete all as specified. \n | 2 | Each | |
87 | 80 | Supply and Fixing Modular bell push switch 6 Amps with indicator single pole one way, 1 Module complete all as specified. | 2 | Each | |
88 | 81 | Supply and Fixing Modular switch 16 Amp single pole one way, 2 Module all as specified. | 4 | Each | |
89 | 82 | Supply and Fixing bell multi music type 230 volts complete with connections all as specified and directed. | 10 | Each | |
90 | 83 | Supply and Fixing Modular fan regulator electronic step type 120watt, 2 Module complete all as specified. | 6 | Each | |
91 | 84 | Supply and Fixing lamp holder, PVC polycarbonate type with back plate suitable for batten fittings complete all as specified. | 18 | Each | |
92 | 85 | Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified. | 12 | Each | |
93 | 86 | Supply and Fixing Modular socket 2-in-1, 5 pins 16 Amps , combined 2 Module complete all as specified. | 4 | Each | |
94 | 87 | Supply and Fixing switch piano flush type 5 Amps single pole one way complete all as specified. | 30 | Each | |
95 | 88 | Supply and Fixing switch piano flush type 15 Amps single pole one way complete all as specified. | 20 | Each | |
96 | 89 | Supply and Fixing socket outlet flush type 2-in-1, 3 pins 5 Amp multipurpose complete all as specified. | 30 | Each | |
97 | 90 | Supply and Fixing socket outlet flush type 2-in-1, 3 and 5 pins 15 Amp multipurpose complete all as specified. | 20 | Each | |
98 | 91 | Supply and Fixing fan regulator electronic step type & flush type complete all as specified. | 17 | Each | |
99 | 92 | Supply and Fixing bell Push switch flush type 6 Amp single pole one way complete all as specified. | 10 | Each | |
100 | 93 | Supply & fixing indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 20 watt LED Tube fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. \nMake: - Havells, Cat Part No: LUMILINEBS20WLED 865 SPC WH or equivalent to CG/Bajaj/Philips | 44 | Each | |
101 | 94 | Supply & fixing indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 9 watt LED Tube fitting mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. \nMake: - Havells, Cat Part No: LUMILINEBS9WLED 865 SPC WH or equivalent to CG/Bajaj/Philips | 18 | Each | |
102 | 95 | Supply & Fixing indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 10 watt LED Tube fitting mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 5700K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. \nMake: - Havells, Cat Part No: INTEGRANEOSURFA CEDLS10WLED875S) or equivalent to CG/Bajaj/Philips | 6 | Each | |
103 | 96 | Supply and Fixing decorative wall light fitting made up of Polycarbonate with outer cover shape having glove/mars suitable for B-22 base holder including with 10 Watt LED lamp complete with all accessories and including connection complete all as specified and directed. \nMake: Havells Cat Part No MARS Shape LHFOFWE1TZ1W0129405) or equivalent to Philips/Bajaj/CG. | 14 | Each | |
104 | 97 | Supply and Fixing environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and directed. \nMake:- Havells ordering Cat Part No. HEXAFT10WLED857SSY MBOPC or equivalent in Bajaj/Philips/Wipro/CG. | 14 | Each | |
105 | 98 | Supply and Fixing LED 10W lamp suitable for normal holder (Base Cap B22) complete all as specified. \nMake:- Havells/Philips/Bajaj/CG. | 46 | Each | |
106 | 99 | Taking down old unserviceable existing DB / enclosures any size and any type as iorn sheet scrap including MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed. | 23 | Each | |
107 | 100 | S&F MCB distribution board, SPN 8 Way, double door, sheet steel, phosphatised, powder painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified. | 15 | Each | |
108 | 101 | Supply & fixing MCB SP 6 - 32 Amps, 'B' series, bracking cap10KA complete all as specified and directed. | 28 | Each | |
109 | 102 | Supply & fix MCB SPN 40 Amps, 'C' series, bracking cap10KA, 240V complete all as specified and directed. | 12 | Each | |
110 | 103 | Supply and fix SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts complete with all conction as directed. | 8 | Each | |
111 | 104 | Supply and install of 30W LED building security light fitting with lens & driver, powder coated pressure dia cast aluminium, top opening and maintenance with heat resistance toughened glass, built in short circuit protection, over voltage protection and surge protection, IP-65 proction with luminaire efficiency of greater than 80 Lumen/Watt, Colour rendering (CRI) of 70 and co-related colour temperature (CCT) of 5700K (±500K). The luminaire should have 10KV surg protection, PF 0.9 and total harmonic ddistortion of THD 10%, voltage range of 140-280V including all connections complete all as specified. \nMake of fitting:- Havells (as per Cat Part No. ENDURACITYLITEPLAT PLUSSL30WLED757SASYBOPC) or equivalent in CG/Bajaj/Philips/C&S (Meeting all the above specification). \nMake of LED: CREE/Nichia/Orram/Lumiled /Bridgelux. | 4 | Each | |
112 | 105 | M&L for building security light bracket made out of 40mm dia light grade GI pipe of 1.2m length bent to required shape suitable for fixing street light fitting on steel tubular pole including two Nos clamps made out 40mmx6mm flat with suitable nuts and bolts including two coats of aluminium paint over a coating of red oxide primer complete all as directed taking down old unserviceable bracket as scrap any size/description. | 2 | Each | |
113 | 106 | Supply and Installation with all connections of LCD display AC single phase electronic KWH Meter with box, Two wire, tamper proof, static meter of class 1.0, 240V, 50Hz 10A-60A conforming to relevant IEC standards complete all as directed by Engineer-in-Charge and including taking down old unserviceable electric/electronic meter. \nMake: Secure/L&T/Schiedent. | 10 | Each | |
114 | 107 | Taking down the ceiling fan of any sweep carefully from its installed position, dismantling complete with down rod, repair/replacement of unserviceable parts (like as bearing, capacitor, burnt winding, rubber wheel bush etc) and cleaning of all dust, applying grease for bearings, reassembligh the fan and blades, painting of fans and down rod with synthetic enamel white paint by spraying single coat including filling cavities with filler, writing MES No with black paint, and keeping a side safely and hanging/refixing in position and connecting up including provision of 3 core twisted flexible copper conductor cable of 0.75sqmm from ceiling rose to connector of fan and testing on completion complete all as specified and directed. \nNote:- The spare parts (like as bearing, capacitor, rubber wheel push, fan winding etc) required shall be measured and paid separately under relevant items. | 30 | Each Job | |
115 | 108 | Taking down the exhaust fan of any sweep carefully from its installed position, dismantling complete with down rod, repair/replacement of unserviceable parts (like as bearing, capacitor, burnt winding, rubber wheel bush etc) and cleaning of all dust, applying grease for bearings, reassembligh the fan and blades, painting of fans and down rod with synthetic enamel white paint by spraying with single coat including filling cavities with filler, writing MES No with black paint, and keeping a side safely and hanging/refixing in position and connecting up including provision of 3 core twisted flexible copper conductor cable of 0.75sqmm from ceiling rose to connector of fan and testing on completion complete all as specified and directed. \nNote:- The spare parts (like as bearing, capacitor, rubber wheel push, fan winding etc) required shall be measured and paid separately under relevant items. | 30 | Each Job | |
116 | 109 | Supply and Fix in repair ball bearing suitable for ceiling fan/exhaust fan of any type complete. | 30 | Each | |
117 | 110 | Supply and Fix inrepair capacitors 2.5 MFD/3.5 MFD suitable for all types of fans complete all as directed.\nMake: - Usha, Universal, Epcos. | 30 | Each | |
118 | 111 | Supply and Fix in repair rubber wheel bush and with GI bolt, nut, washer and split pin complete all as specified and directed. | 30 | Each | |
119 | 112 | Dismantling of worn out/burnt out windings of ceiling fan and re-winding the motor of ceiling fan with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut and testing for original and consumption complete for following sizes: | |||
120 | 112.01 | 1200/1400 mm sweep. | 17 | Each | |
121 | 113 | Dismantling of worn out/burnt out windings of exhaust fan any type and re-winding the motor with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete and testing for original and consumption complete for following sizes: | |||
122 | 113.01 | 200/225/250 mm sweep. | 10 | Each | |
123 | 113.02 | 300 mm sweep. | 10 | Each | |
124 | 114 | Taking out the electric geyser of capacity 25 Ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, dismantling the unit and replacing the defective heating element and resolve all leakage problems from geyser and painting with one coat of synthetic enamel paint and writing MES No and refixing in its original position and reconnecting the inlet/outlet water pipes an dtesting on completin complete all as directed by Engr-in-Charge. \nNote:- The spare parts like Heating element, hot & cold flexible water pipe line, Thermostate required shall be measured and paid separately under relevant items as supply only. | |||
125 | 114.01 | Supply only electric heating element 1.5 KW ISI marked complete, 240 Volt AC. \nMake- Bajaj/ Recold/Daspass/Theeta/Power Pack or as per sample / installed at site | 10 | Each | |
126 | 114.02 | Supply only thermostate switch CO-THERMO Type TSE-GA3 Safety 230 volt, ISI marked complete, suitable for Geyser 25 Ltr. Make/Danfoss or equivalent /installed at site | 10 | Each | |
127 | 114.03 | Supply only hot water / cold water pipe 600mm long as per existing type complete all as specified and directed. | 10 | Set |