Completion Of Balance Leftover Work For Provision Of Development Of Balance Land Of Coast Guard And Provision Of Balance Married Accommodation At Visakhapatnam Risk Cost Contract Against Ca No Ce Navy Viz 14 Of 2013 14, VISAKHAPATNAM-Andhra Pradesh

Military Engineer Services-MES has published Completion Of Balance Leftover Work For Provision Of Development Of Balance Land Of Coast Guard And Provision Of Balance Married Accommodation At Visakhapatnam Risk Cost Contract Against Ca No Ce Navy Viz 14 Of 2013 14. Submission Date for this Tender is 17-12-2020. Land Development Tenders in VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25731102
Corrigendum : Completion Of Balance Leftover Work For Provision Of Development Of Balance Land Of Coast Guard And Provision Of Balance Married Accommodation At Visakhapatnam Risk Cost Contract Against Ca No Ce Navy Viz 14 Of 2013 14
Open Tender
Indian
Andhra Pradesh
VISAKHAPATNAM
17-12-2020

Tender Details

Completion Of Balance Leftover Work For Provision Of Development Of Balance Land Of Coast Guard And Provision Of Balance Married Accommodation At Visakhapatnam Risk Cost Contract Against Ca No Ce Navy Viz 14 Of 2013 14

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Nov-2020 Date Corrigendum Date 05-12-2020
2 26-Nov-2020 Date Corrigendum3 Date 10-12-2020
3 02-Dec-2020 Revised BOQ and certain pages of tender documents BOQ 10-12-2020
4 10-Dec-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-12-2020

Key Value

Document Fees
INR 3000 /-
EMD
INR 795000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: COMPLETION OF BALANCE/LEFTOVER WORK FOR PROVISION OF DEVELOPMENT OF BALANCE LAND OF COAST GUARD AND PROVISION OF BALANCE MARRIED ACCOMMODATION AT VISAKHAPATNAM (RISK & COST CONTRACT AGAINST CA NO CE(NAVY)/VIZ/14 OF 2013-14)
Sl. No. Item Description Item Code / Make Quantity Units
1 0 Schedule "A" Part – I to Schedule "A" Part – XVII:\nNOTE: Schedule "A" Part – I to Part – XIV EXCEPT Schedule "A" Part –IIA , Schedule "A" Part – XV, Schedule "A" Part –XVI and Schedule "A" Part –XVII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only Contractor shall insert their rates for Schedule "A" Part –IIA Schedule "A" Part – XV, Schedule "A" Part –XVI and Schedule "A" Part –XVII under Green coloured field under Column - 6 only
2 1 Lump sum price worked out by the contractor for the “BUILDINGS WORKS”, as listed in Schedule 'A' Part I against the lump sum price of Rs. 6,22,58,900 inserted by MES in Schedule ‘A’ Part-I on Serial Page No. 34 BI01010001010000000000000515BI0100001111 1 Each Job
3 2 Price worked out by the contractor for "INTERNAL WATER SUPPLY ", against the price of Rs. 4,77,007.07 inserted by MES as listed in Schedule 'A' Part - II on Serial Page No. 39 BI01010001010000000000000515BI0100001112 1 Each Job
4 3 Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY ", against the price of Rs. 2,94,401.80 inserted by MES as listed in Schedule 'A' Part - III on Serial Page No. 41 BI01010001010000000000000515BI0100001113 1 Each Job
5 4 Price worked out by the contractor for "SITE CLEARANCE/ EARTH WORK / EXCAVATION/DEMOLITION ", against the price of Rs. 14,96,589.51 inserted by MES as listed in Schedule 'A' Part - IV on Serial Page No. 44 BI01010001010000000000000515BI0100001114 1 Each Job
6 5 Price worked out by the contractor for "AREA DRAINAGE", against the price of Rs. 16,58,823.19 inserted by MES as listed in Schedule 'A' Part - V on Serial Page No. 46 BI01010001010000000000000515BI0100001115 1 Each Job
7 6 Price worked out by the contractor for "SEWAGE DISPOSAL", against the price of Rs. 2,52,664.18 inserted by MES as listed in Schedule 'A' Part - VI on Serial Page No. 49 BI01010001010000000000000515BI0100001116 1 Each Job
8 7 Price worked out by the contractor for "RETAINING WALL", against the price of Rs. 2,27,995.25 inserted by MES as listed in Schedule 'A' Part - VII on Serial Page No. 51 BI01010001010000000000000515BI0100001117 1 Each Job
9 8 Price worked out by the contractor for "COMPOUND WALL ", against the price of Rs. 74,297.55 inserted by MES as listed in Schedule 'A' Part - VIII on Serial Page No. 54 BI01010001010000000000000515BI0100001118 1 Each Job
10 9 Price worked out by the contractor for "ROAD/PATH / CULVERT ", against the price of Rs. 11,60,763.64 inserted by MES as listed in Schedule 'A' Part - IX on Serial Page No. 57 BI01010001010000000000000515BI0100001119 1 Each Job
11 10 Price worked out by the contractor for "EXTERNAL WATER SUPPLY", against the price of Rs. 1,48,722.1 inserted by MES as listed in Schedule 'A' Part - X on Serial Page No. 59 BI01010001010000000000000515BI0100001120 1 Each Job
12 11 Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", against the price of Rs. 3,97,192.48 inserted by MES as listed in Schedule 'A' Part - XI on Serial Page No. 61 BI01010001010000000000000515BI0100001121 1 Each Job
13 12 Price worked out by the contractor for "INTERNAL FIRE FIGHTING, against the price of Rs. 3,92,224.69 inserted by MES as listed in Schedule 'A' Part - XII on Serial Page No. 62 BI01010001010000000000000515BI0100001122 1 Each Job
14 13 Price worked out by the contractor for "EXTERNAL FIRE FIGHTING, against the price of Rs. 11,70,459.58 inserted by MES as listed in Schedule 'A' Part - XIII on Serial Page No. 64 BI01010001010000000000000515BI0100001123 1 Each Job
15 14 Price worked out by the contractor for "LIGHTNING PROTECTION", against the price of Rs. 86,061.10 inserted by MES as listed in Schedule 'A' Part - XIV on Serial Page No. 65 BI01010001010000000000000515BI0100001124 1 Each Job
16 15 Schedule "A" Part - IA [BUILDING / STRUCTURE WORKS] BI01010001010000000000000515BI0100001125
17 16 Serial No 1 : Completion of the leftover /incomplete work for Construction of a block of sub station building complete all as shown on drawings and as specified. BI01010001010000000000000515BI0100001126 1 EACH BLOCK
18 17 NOTES APPLICABLE TO SRL ITEM NO 1, 2 AND 5 OF SCH 'A' Pt-IA\n(i) THE LEFT OVER WORK MAINLY CONSIST OF SCHEDULE OF FINISHES WHICH INCLUDES FLOORING, ROOF TREATMENT AND FINISHES TO WALL AND CEILING.\n(ii) THE TENDERER SHALL VISIT THE SITE TO ASSESS THE EXACT SCOPE OF WORK AND THEN QUOTE THEIR RATES. THE QUOTED RATES ARE DEEMED TO INCLUDE ALL THESE REQUIREMENTS AND SHOULD MAKE THE ASSET FUNCTIONAL TO THE ENTIRE SATISFACTION OF AGE(I) AND NOTHING EXTRA WILL BE ADMISSIBLE TO THEM AT ANY PRETEXT. BI01010001010000000000000515BI0100001127
19 18 Serial No 2 : Completion of the leftover /incomplete work for Construction of a block of Pump house building complete all as shown on drawings and as specified. BI01010001010000000000000515BI0100001128 1 EACH BLOCK
20 19 Serial No 3 : Completion of the leftover /incomplete work for Construction of RCC Under ground Sump 2.5 lakh litres capacity complete all as shown on drawings and as specified. \nNote : (i) Inlet pipe, outlet pipe and overflow pipe though shown in drawing is outside the scope of above item and shall be measured and paid seperately. (ii) ENTIRE CONSTRUCTION WORK FOR THIS ITEM HAS BEEN COMPLETED BY THE PREVIOUS CONTRACTOR EXCEPT TESTING. IN THIS ITEM THE SCOPE OF WORK FOR THE CONTRACTOR UNDERTAKING THIS RISK AND COST CONTRACT SHALL BE RESTRICTED TO TESTING OF THE SUMP TO THE SATISFACTION OF THE AGE(I) AND REPAIRS IF ANY REQUIRED. \n(iii) THE QUOTED RATES ARE DEEMED TO BE INCLUSIVE OF THIS AND NOTHING EXTRA IS ADMISSIBLE TO THE CONTRACTOR ON ANY PRETEXT. BI01010001010000000000000515BI0100001129 1 EACH JOB
21 20 ADDITIONAL NOTES APPLICABLE TO SRL ITEM NO 3 AND 4 OF SCH 'A' Pt-IA\n(i) ENTIRE CONSTRUCTION WORK FOR THIS ITEM HAS BEEN COMPLETED BY THE PREVIOUS CONTRACTOR EXCEPT TESTING. IN THIS ITEM THE SCOPE OF WORK FOR THE CONTRACTOR UNDERTAKING THIS RISK AND COST CONTRACT SHALL BE RESTRICTED TO TESTING OF THE SUMP TO THE SATISFACTION OF THE AGE(I) AND REPAIRS IF ANY REQUIRED. \n(ii) THE QUOTED RATES ARE DEEMED TO BE INCLUSIVE OF THIS AND NOTHING EXTRA IS ADMISSIBLE TO THE CONTRACTOR ON ANY PRETEXT. BI01010001010000000000000515BI0100001130
22 21 Serial No 4 : Completion of the leftover /incomplete work for Construction of RCC Under ground Sump 2.0 lakh litres capacity complete all as shown on drawings and as specified. \nNote : (i) Inlet pipe, outlet pipe and overflow pipe though shown in drawing is outside the scope of above item and shall be measured and paid seperately. (ii) ENTIRE CONSTRUCTION WORK FOR THIS ITEM HAS BEEN COMPLETED BY THE PREVIOUS CONTRACTOR EXCEPT TESTING. IN THIS ITEM THE SCOPE OF WORK FOR THE CONTRACTOR UNDERTAKING THIS RISK AND COST CONTRACT SHALL BE RESTRICTED TO TESTING OF THE SUMP TO THE SATISFACTION OF THE AGE(I) AND REPAIRS IF ANY REQUIRED. \n(iii) THE QUOTED RATES ARE DEEMED TO BE INCLUSIVE OF THIS AND NOTHING EXTRA IS ADMISSIBLE TO THE CONTRACTOR ON ANY PRETEXT. BI01010001010000000000000515BI0100001131 1 EACH JOB
23 22 Serial No 5 : Completion of the leftover /incomplete work for Construction of Scooter shed for 80 Scooters complete all as shown on drawings and as specified. BI01010001010000000000000515BI0100001132 1 EACH BLOCK
24 23 Serial No 6 : Completion of the leftover /incomplete work for Construction of Septic tank 200 users complete all as shown on drawings and as specified. BI01010001010000000000000515BI0100001133 2 EACH JOB
25 24 Serial No 7 : Completion of the leftover /incomplete work for Construction of Soakage well of internal dia 3Mtr and 4.5 Mtr effective depth complete all as shown on drawings and as specified. BI01010001010000000000000515BI0100001134 2 EACH JOB
26 25 Serial No 8 : Mild steel gate of 5.50 m wide and 2 m high (with wicket gate 0f 1.2m width) made out of mild steel angle iron, mild steel sheet, mild steel square bars, flat including RCC columns, excavation and earth work in any type of soil, painting gates with two coats of synthetic enamel paint over a coat of primer complete all as shown on drawings and as specified. ENTIRE CONSTRUCTION WORK FOR THIS ITEM HAS BEEN COMPLETED BY THE PREVIOUS CONTRACTOR. BI01010001010000000000000515BI0100001135
27 26 NOTE APPLICABLE TO SRL ITEM NO 8 OF SCH 'A' Pt-IA\nENTIRE CONSTRUCTION WORK FOR THIS ITEM HAS BEEN COMPLETED BY THE PREVIOUS CONTRACTOR. BI01010001010000000000000515BI0100001136
28 27 Schedule "A" Part - XV [MISCELLANEOUS ITEMS TO BE QUOTED BY CONTRACTOR FOR INTERNAL WATER SUPPLY, INTERNAL ELECTRIC SUPPLY, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIC SUPPLY, GEYSER, INTERNAL FIRE FIGHTING, EXTERNAL FIRE FIGHTING, LIGHTNING PROTECTION, AUTOMATIC FIRE ALARM AND DETECTION SYSTEM, DG SET AND AVIATION OBSTRUCTION LIGHT] BI01010001010000000000000515BI0100001137
29 28 Sl No 1 : Point wiring with 1.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral and earth continuity) drawn in concealed conduit including Provision of 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, electronic fan regulators and connecting the earth wire to common earth dolly for one light point controlled by one switch. BI01010001010000000000000515BI0100001138 1461 Point
30 29 Sl No 2 : All as per Sl No.1 hereinbefore but one fan point controlled by one switch and regulator. BI01010001010000000000000515BI0100001139 328 Point
31 30 Sl No 3 : All as per Sl No.1 hereinbefore but for one exhaust fan point controlled by one switch. BI01010001010000000000000515BI0100001140 272 Point
32 31 Sl No 4 : All as per Sl No.1 hereinbefore but for one bell/buzzer point controlled by one push button on the same board with other switches or independent . BI01010001010000000000000515BI0100001141 170 Point
33 32 Sl No 5 : All as per item No 1 hereinbefore but for 5 amps socket outlet on independent board.\n\n. BI01010001010000000000000515BI0100001142 466 Point
34 33 Sl No 6 : All as per item No. 1 hereinbefore but for stair case wiring one light point controlled by two two way switches.\n\n. BI01010001010000000000000515BI0100001143 85 Point
35 34 Sl No 7 : Point wiring with 2.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral )and 1.5 sq mm cable for earth continuity) drawn in concealed conduit including Provision of 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, electronic fan regulators and connecting the earth wire to common earth dolly for one 15 Amps power point on independent board.\n\n. BI01010001010000000000000515BI0100001144 111 Point
36 35 Sl No 8 : Electronic regulator stepped socket type for ceiling fan of 1200 mm sweep 120 W single module complete all as specified. BI01010001010000000000000515BI0100001145 472 Each
37 36 Sl No 9 : Telephone socket with top conector complete all as directed. BI01010001010000000000000515BI0100001146
38 37 Sl No 10 : TV cable outlet complete all as directed. BI01010001010000000000000515BI0100001147 165 Each
39 38 Sl No 11 : Concealed PVC rigid non metallic conduit heavy grade 20 mm dia with and including one run of 2 mm dia GI wire for drawing TV cable/telephone cable complete all as specified and directed. \n(Note: 1 run of GI wire and 1 run of PVC conduit shall be measured as one unit) BI01010001010000000000000515BI0100001148 2730.1 Running Meter
40 39 Sl No 12 : Submain wiring in concealed PVC conduit with two runs of 2.5 sq mm and one run of 1.5 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 20 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified for building security lights. \n(Note: 2 runs of 2.5 sq mm cable and one run of 1.5 sq mm cable and 1 run of PVC conduit shall be measured as one unit) \n\n. BI01010001010000000000000515BI0100001149 868.2 Running Meter
41 40 Sl No 13 : Submain wiring in concealed PVC conduit with two runs of 4 sq mm and one run of 2.5 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 25 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified. \n(Note: 2 runs of 4 sq mm cable and one run of 2.5 sq mm cable and 1 run of PVC conduit shall be measured as one unit) \n. BI01010001010000000000000515BI0100001150 240 Running Meter
42 41 Sl No 14 : Submain wiring in concealed PVC conduit with two runs of 6 sq mm and one run of 4 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 20 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified for building security lights. \n(Note: 2 runs of 6 sq mm cable and one run of 4 sq mm cable and 1 run of PVC conduit shall be measured as one unit) \n\n. BI01010001010000000000000515BI0100001151 3600 Running Meter
43 42 Sl No 15 : Submain wiring in concealed PVC conduit with four runs of 10 sq mm and one run of 6 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 40 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified for building security lights. \n(Note: 4 runs of 10 sq mm cable and one run of 6 sq mm cable and 1 run of PVC conduit shall be measured as one unit) BI01010001010000000000000515BI0100001152 25 Running Meter
44 43 Sl No 16 : Fluorescent tube light fitting box type 1x36 watt with CRCA steel sheet housing with white reflector cover fitted to the body with electronic ballast including 36/40 watt tube. Cat No. BJCEB 136/140 WEB of Bajaj or equivalent in Havels/ CG/ Philips \n(Note: Tube rod only will be issued under Sch 'B' free for fixing only) BI01010001010000000000000515BI0100001153 983 Each
45 44 Sl No 17 : CFL fitting 1x11 watt surface mounting type including 1x11 watt lamp. Cat No. BJC 111 of Bajaj or equivalent in Havels/ CG/ Philips BI01010001010000000000000515BI0100001154 170 Each
46 45 Sl No 18 : CFL fitting 1x18 watt surface mounting type including 1x18 watt lamp. Cat No. BSP of Bajaj or equivalent in Havels/ CG/ Philips BI01010001010000000000000515BI0100001155 884 Each
47 46 Sl No 19 : Security light fitting 2X18 watt including GI pipe bracket made out of 25/40mm dia medium grade pipe, MS clamps, nuts, bolts and washers all as specified and directed by Eng-in-charge. Make: Bajaj-Cat No.BJSLF 218 DD CFL or equivalent in CG /Philips / Wipro\n. BI01010001010000000000000515BI0100001156 58 Each
48 47 Sl No 20 : MCB DB TPN 4 way with 200 amps 415 V rated copper busbar in sheet steel enclosure double door type complete all as specified.\n\n. BI01010001010000000000000515BI0100001157
49 48 Sl No 21 : Fixing only MCB DB SPN 8 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified.\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 at the rate inerted there.\n. BI01010001010000000000000515BI0100001158 11 Each
50 49 Sl No 22 : MCB DB SPN 6 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified. BI01010001010000000000000515BI0100001159 146 Each
51 50 Sl No 23 : MCB DB SPN 4 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified. BI01010001010000000000000515BI0100001160
52 51 Sl No 24 : MCB DB SPN 2 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified. BI01010001010000000000000515BI0100001161 62 Each
53 52 Sl No 25 : MCB TPN 0 to 30 amps capacity 415 V complete all as specified. BI01010001010000000000000515BI0100001162
54 53 Sl No 26 : Fixing only MCB SPN 0 to 30 amps capacity 240 V complete all as specified.\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 at the rate inerted there. BI01010001010000000000000515BI0100001163 224 Each
55 54 Sl No 27 : MCB SP 0 to 32 amps capacity 240 V complete all as specified.\n. BI01010001010000000000000515BI0100001164 125 Each
56 55 Sl No 27 A : Fixing only MCB SP 0 to 32 amps capacity 240 V complete all as specified.\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 at the rate inerted there. BI01010001010000000000000515BI0100001165 494 Each
57 56 Sl No 28 : Dummy plates for DBs complete all as directed.\n\n. BI01010001010000000000000515BI0100001166 7 Each
58 57 Sl No 29 : Sheet metal enclosure single pole neutral with two pin and earth plug socket complete with single pole MCB of 16 Amps capacity 240 volts AC supply for geyser complete all as specified. BI01010001010000000000000515BI0100001167
59 58 Sl No 30 : Laying only on wall/roof/floor etc with PVC clamps XLPE insulated and PVC bedded galvanised strip armoured heavy duty electrical cable with aluminium conductor 1100 V grade conforming to IS 7098-1974 of 16 sq mm 4 core for service connection complete all as specified. \nNote : Cable will be issued under Sch 'B' free for laying only) BI01010001010000000000000515BI0100001168 2275 Running Meter
60 59 Sl No 31 : Energy saving electronic type energy meter temper proof type electrically operated 5 to 20 amps capacity AC 3 phase 415 volts complete with LED display conforming to IS-13779 complete all as specified. Make : HPL/HAVELLS/EE/ANCHOR. BI01010001010000000000000515BI0100001169
61 60 Sl No 32 : Energy saving electronic type energy meter temper proof type electrically operated 5 to 20 amps capacity AC single phase 415 volts complete with LED display conforming to IS-13779 complete all as specified. Make : HPL/HAVELLS/EE/ANCHOR. BI01010001010000000000000515BI0100001170 168 Each
62 61 Sl No 33 : 25x4 mm galvanised iron strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified.\n\n. BI01010001010000000000000515BI0100001171 178 Running Meter
63 62 Sl No 34 : Sheet metal enclosure made out of 2 mm thick mild steel sheet with doors and locking arrangement powder coated, dust and vermin proof, cubical type for housing KWH meter, MCB DBs etc including provision of 20 mm thick wooden plank of suitable size as base duly fixed with nuts and bolts of suitable size complete all as directed.\n\n. BI01010001010000000000000515BI0100001172 178 Each
64 63 Sl No 35 : Factory made SKB 5/6/7 frame MCCBs panel board with 125 amps incomer and 08 number of outgoing ways pre wired with volt meter, ammeter, selector switches CTs, control fuse & indicating lamps and conforming to IS 8623 with and including the following MCCB/MCBs complete all as directed:-\n\n(a) MCCB 4 pole 125 amps 16 KA 415 volts-01 No.\n(b) MCB 4 pole 40 amps 415 volts - 07 Nos.\n(c) MCB SPN 6 to 32 amps - 01 No.\n(d) MCB SP 6 to 32 amps - 01 No.\n BI01010001010000000000000515BI0100001173 6 Each
65 64 Sl No 36 : Factory made SKB 5/6/7 frame MCCBs panel board with 125 amps incomer and 08 number of outgoing ways pre wired with volt meter, ammeter, selector switches CTs, control fuse & indicating lamps and conforming to IS 8623 with and including the following MCCB/MCBs complete all as directed:-\n(a) MCCB 4 pole 125 amps 16 KA 415 volts-01 No.\n(b) MCB 4 pole 40 amps 415 volts - 05 Nos.\n(c) MCB SPN 0 to 32 amps - 01 No.\n(d) MCB SP 6 to 32 amps - 01 No.\n BI01010001010000000000000515BI0100001174
66 65 Sl No 37 : Fixing only Cubical type bus bar chamber made out of 2 mm thick mild steel sheet, powder caoted with grouting arrangements to wall with provision of door shutter with hinges, locking arrangement etc including 3 Nos of aluminium bus bar of capacity 100 amps for phases and one number bus bar of capacity 50 amps for neutral mounted on PVC/porcelain insulators including arrangements for termination of incoming and outgoing cables/sub main wiring complete all as directed. Note : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 at the rate inerted there. BI01010001010000000000000515BI0100001175 42 Each
67 66 Sl No 38 : Cubical type bus bar chamber made out of 2 mm thick mild steel sheet, powder coated with grouting arrangements to wall with provision of door shutter with hinges, locking arrangement etc including 3 Nos of aluminium bus bar of capacity 50 amps for phases and one number bus bar of capacity 25 amps for neutral mounted on PVC/porcelain insulators including arrangements for termination of incoming and outgoing cables/sub main wiring complete all as directed. BI01010001010000000000000515BI0100001176
68 67 Sl No 39 : Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth lead of 25x4 mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, 32mm dia GI light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion. BI01010001010000000000000515BI0100001177 12 Each Set
69 68 Sl No 40 : 4 mm dia galvanised iron wire continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified.\n\n. BI01010001010000000000000515BI0100001178 1000 Running Meter
70 69 Sl No 41 : Fixing only water heater storage type electrically operated 50 litres capacity complete with connecting PVC pipes, CP copper pipe, NRV etc complete all as directed. \nNote: Water heater will be issued under Sch 'B' free for fixing.\n\n. BI01010001010000000000000515BI0100001179
71 70 Sl No 42 : Brass CP mixer for mixing hot and cold water screwed for iron pipe and fixed complete all as specified.\n\n. BI01010001010000000000000515BI0100001180
72 71 Sl No 43 : Cutting the existing 150mm dia CI pipe line in position and inserting Tee 150x150x150 mm dia with required specials \nNote: Unit rate quoted shall include the cost of CI TEE and specials. BI01010001010000000000000515BI0100001181 2 Job
73 72 Sl No 44 : Ductile iron pipes 150 mm bore spigot socket centrifugally cast (spun) class K-9 with cement mortar lining inside with portland slag cement as per IS 455:1989 and outside metallic zinc coating as per IS conforming to IS-8329 of 2000 or ISO 2531 of 2009 laid in trenches, on floor/walls complete all as specified. BI01010001010000000000000515BI0100001182 495 Running Meter
74 73 Sl No 45 : Ductile iron pipe fittings (spigot and socketted/flanged ends) such as bends, tees, tapers, short pieces, collors, reducers, flanged blanks/blind etc up to 150 mm bore with cement mortar lining inside with portland slag cement as per IS 455:1989 and outside metallic zinc coating as per IS conforming to IS-8329 of 2000 or ISO 2531 of 2009 complete all as specified. BI01010001010000000000000515BI0100001183 1050 Kilogram
75 74 Sl No 46 : Sluice valve 150 mm dia non raising stainless steel spindle, brass spindle check nut, CI gate body, brass gate ring, brass body ring IS marked IS-1485 PN 1.6 complete including jointing and jointing material complete all as specified. BI01010001010000000000000515BI0100001184 8 Each
76 75 Sl No 47 : Valve chamber of internal size 1000x1000x1000mm comprising of 100mm thick PCC 1:5:10 type E2 (using 40mm graded stone aggregate) foundation, 230mm thick brick walls in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally upto 150mm below GL, 100 mm thick PCC 1:3:6 type B1(using 20 mm graded stone aggregate) coping, 5mm thick MS sheet cover with suitable hinges and locking arrangement supported on angle iron frame 50x50x6mm, painting steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including necessary excavation and earthwork in any type of soil complete all as specified and directed. \n. BI01010001010000000000000515BI0100001185 12 Job
77 76 Sl No 48 : Centrifugal pump set capable of pumping 1200 litres per min at a head of 80 metres conforming to IS, coupled directly through a set of flexible coupling mounted on fabricated MS base plate, driven by and including electric motor squirrel cage induction suitable for operation on 415 V 3 phase, 50 Hz AC synchronous speed not more than 1500 RPM including copper conductor cable with flexible pipe protection from the existing panel mounted star delta starter at common supply to pump motor alongwith pressure gauge on discharge side, gun metal non return valve 50mm bore - 1 No, gun metal gate valve 50mm bore -1 No, flanged type foot valve with strainer etc 100mm -1 No and suitable PCC foundation etc complete all as directed.\n\n. BI01010001010000000000000515BI0100001186
78 77 Sl No 49: Cast iron air valves 50 mmm bore with two air outlets and fixing up in cast iron water supply mains complete all as directed.\n\n. BI01010001010000000000000515BI0100001187 3 Each
79 78 Sl No 50 : Addition/extension 11 KV, 630A 21 KA outdoor, extensible type SF6 insulated RMU with two Nos VCB along with protection on relay and CTs Type : FBX-E/T2T2/outdoor manual extensible complete all as directed. BI01010001010000000000000515BI0100001188 1 Job
80 79 Sl No 51 : Cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor 11000 V grade of size 3 Core 185 Sqmm laid in trenches complete all as specified and directed. BI01010001010000000000000515BI0100001189 600 Running Meter
81 80 Sl No 52 : Cable jointing kit for 11 KV (E) grade cable for out-door termination cold shrinkable type joint complete with jointing materials and accessories suitable for 3 Core XLPE armoured aluminum conductor cable of size 185 sqmm complete all as specified. BI01010001010000000000000515BI0100001190 2 Each
82 81 Sl No 53 : Cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and acessories suitable for 3 Core XLPE armoured alumium conductor cable of size 185 Sqmm complete all as specified. BI01010001010000000000000515BI0100001191 2 Each
83 82 Sl No 54 : Fixing only Free standing compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factorymade powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisting of bus bar chamber with tinned copper bus of suitable rating 1800 Amps per phase for neutral 1200 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation (Main LT Feeder pillar box-01 in substation)\n(a) ACB 1250 Amps rating 4 Pole with thermal magnetic release(manual draw out) 1 No (in coming)\n(b) ACB 1000 Amps 35 KA - 02 Nos (01 for outgoing to main panel at type II & III block 1, and 01 spare)\n(c) MCCB 200 Amps 4 Pole 36 KA -01 No (spare)\n(d) MCCB 100 Amps 3 Pole 25 KA -01 No (spare)\n(e) Digital type ammeter of (0-1200A) with selector switch & suitable CTs(3 Nos)-01 set\n(f) LED indication lamps(R,Y,B) -01 set \n(g) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'. BI01010001010000000000000515BI0100001192 1 Job
84 83 Sl No 55 : Fixing only Free standing compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisiting of bus bar chamber with tinned copper bus of suitable rating 1800 Amps per phase for neutral 1200 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation (Main LT Feeder pillar Box No-01 at substation) \n(a) ACB 1250 Amps rating 4 Pole with thermal magnetic release(manual draw out) 1 No (in coming)\n(b) ACB 1000 Amps with thermal magnetic release(manual draw out) - 02 Nos (01 for outgoing to building panel IV/V blocks and 01 spare)\n(c) MCCB 500 Amps 4 Pole 36 KA (01 No for DG set panel) \n(d) MCCB 200 Amps 4 Pole 36 KA 02 No for Fire fighting panel and 01 No spare\n(e) Digital type ammeter of (0-1200A) with selector switch & suitable CTs(3 Nos)-01 set\n(f) LED indication lamps(R,Y,B) -01 set \n(g) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No Note : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'. BI01010001010000000000000515BI0100001193 1 Job
85 84 Sl No 56 : Fixing only Free standing out door compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm thick both rear and front operated doors provision for machanical and electrical interlocking arrangement consisiting of bus bar chamber with tinned copper bus of suitable rating 1500 Amps per phase for neutral 1000 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation (Main panel at Block 1 at type II & III qtrs) \n(a) ACB 1000 Amps 4 Pole with thermal magnetic release(manual draw out) 1 No(incoming) \n(b) MCCB 400 Amps 4 Pole 35 KA 04 No (01 for each block I,e 1,2 &3 and 01 spare)\n(c) MCCB 63 Amps 4 Pole 25 KA 01 Nos (street light)\n(d) MCCB 40 Amps 4 Pole 25 KA 01 Nos (spare)\n(e) Digital type ammeter of (0-1200A) with selector switch & suitable CTs(3 Nos)-01 set\n(f) LED indication lamps(R,Y,B) -01 set \n(g) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'.\n\n\n. BI01010001010000000000000515BI0100001194 1 Job
86 85 Sl No 57 : Fixing only Free standing out door compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisiting of bus bar chamber with tinned copper bus of suitable rating 600 Amps per phase, for neutral 400 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation (Main panel at Block I at type II & III qtrs))\n(a) MCCB 400 Amps 4 Pole 35 KA 1 No (incoming)\n(b) MCCB 125 Amps 4 Pole 25 KA 02 Nos (for building load)\n(c) MCCB 63 Amps 4 Pole 25 KA 01 No (01 for 13 passenger lift )\n(d) MCCB 40 Amps 4 Pole 25 KA 02 Nos (01 for Street light fittings & for spare)\n(e) Digital type ammeter of (0-600A) with selector switch & suitable CTs(3 Nos)-01 set\n(f) LED indication lamps(R,Y,B) -01 set \n(g) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'.\n\n BI01010001010000000000000515BI0100001195 3 Job
87 86 Sl No 58 : Free standing out door compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisiting of bus bar chamber with tinned copper bus of suitable rating 600 Amps per phase, for neutral 400 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation (For one block & type IV & V Qtrs)\n(a) MCCB 400 Amps 4 pole 35 KA 1 No (for incoming)\n(b) MCCB 125 Amps 4 Pole 25 KA 03 Nos (2 No For type IV/V building load, 01 spare )\n(c) MCCB 63 Amps 4 Pole 25 KA 02 Nos (01 for 13 passenger lift & 01 Spare)\n(d) Digital type ammeter of (0-600A) with selector switch & suitable CTs(3 Nos)-01 set\n(e) LED indication lamps(R,Y,B) -01 set \n(f) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\n\n\n\n\n\n BI01010001010000000000000515BI0100001196
88 87 Sl No 59 : Fixing only Out door free standing compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisiting of bus bar chamber with tinned copper bus of suitable rating 800 Amps per phase, for neutral 500 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation near the DG set panel.(For DG set panel)\n(a) MCCB 500 Amps 4 pole 36 KA 1 No (incoming)\n(b) MCCB 400 Amps 3 pole 36 KA - 01 No (for lift panel for all type II/III blocks )\n(c) MCCB 200 Amps 4 pole 36 KA - 01 No , 01 No for fresh water supply pump house )\n(d) MCCB 100 Amps 4 pole 25 KA 02 Nos (01 No for lift panel at type IV/V block & 01 spare)\n(e) Change over switch for 630 Amps - 01 No \n(f) Digital type ammeter of (0-600A) with selector switch & suitable CTs(3 Nos)-01 set\n(g) LED indication lamps(R,Y,B) -01 set \n(h) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\n\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'.\n\n BI01010001010000000000000515BI0100001197 1 Job
89 88 Sl No 60 : Indoor free standing compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisting of bus bar chamber with tinned copper bus bar of suitable rating 200 Amps and per phase for neutral 100 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation (panel for pump set) :-\n(a) MCCB 200 Amps 4 pole 36 KA - 01 No ( incoming )\n(b) MCCB 100 Amps 4 Pole 3 Nos (02 No for pumps , 01 No for spare)\n(c) Automatic star delta Starter of 37 kw type +D25- 2 Nos\n(d) MCCB 63 Amps 25 ka 4 pole 01 No(building lights)\n(e) Digital type ammeter of (0-100A) with selector switch & suitable CTs(3 Nos)-01 set\n(f) LED indication lamps(R,Y,B) -01 set \n(g) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\n\n\n\n\n\n\n\n\n BI01010001010000000000000515BI0100001198
90 89 Sl No 61 : Fixing only Out door free standing compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisiting of bus bar chamber with tinned copper bus of suitable rating 400 Amps per phase, for neutral 200 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following including foundation near the DG set panel.( Main lift panel at type II/III for blocks 1, 2,& 3):-\n(a) MCCB 400 Amps 4 Pole 35 KA 01 No \n(b) MCCB 125 Amps 4 Pole 25 KA 04 Nos (01 for each block 8 pass lift and 01 for spare)\n(c) Digital type ammeter of (0-200A) with selector switch & suitable CTs(3 Nos)-01 set\n(d) LED indication lamps(R,Y,B) -01 set \n(e) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\n\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'.\n\n BI01010001010000000000000515BI0100001199 1 Job
91 90 Sl No 62 : Out door free standing compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisiting of bus bar chamber with tinned copper bus of suitable rating 100 Amps per phase, for neutral 100 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation near the DG set panel.(for lift and type IV & V qtrs)\n(a) MCCB 100 Amps 25 KA 4 pole 1 No (incoming)\n(b) MCCB 63 Amps 3 pole 25 KA - 02 Nos(01 No for 8 Pass lift & 01 spare)\n(c) MCCB 40 A 415V,16KA, 4 Pole-01 No(spare)\n(d) Digital type ammeter of (0-100A) with selector switch & suitable CTs(3 Nos)-01 set\n(e) LED indication lamps(R,Y,B) -01 set \n(f) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\n\n\n\n\n\n\n\n\n\n\n\n\n\n. BI01010001010000000000000515BI0100001200
92 91 Sl No 63 : Fixing only Indoor free standing compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement consisiting of bus bar chamber with tinned copper bus of suitable rating 200 Amps per phase, for neutral 100 Amps with support of epoxy insulators for incoming and out going suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following and including foundation( Lift panel in block 1,2,3,4) \n(a) MCCB 125 Amps 4 Pole 25 KA 01 Nos (incoming)\n(b) MCCB 63 Amps 3 pole 25 KA - 03 Nos(for two lifts and 01 spare)\n(c) Digital type ammeter of (0-200A) with selector switch & suitable CTs(3 Nos)-01 set\n(d) LED indication lamps(R,Y,B) -01 set \n(e) Digital type voltmeter with inbuilt selector switch (0-500V)-01 No\n\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'.\n\n\n\n\n\n\n\n\n\n\n\n\n. BI01010001010000000000000515BI0100001201 3 Job
93 92 Sl No 64 : MCCB enclosure fabricated indoor wall mounted type compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following:-( For Lift machine room )\n(a) MCCB 63 Amps 3 pole 25 KA - 01 Nos(01 for lift)\n(b) LED indication lamps compact type (R,Y,B) -01 set \n\n\n\n\n\n. BI01010001010000000000000515BI0100001202 3 Job
94 93 Sl No 64 A : Fixing only MCCB enclosure fabricated indoor wall mounted type compartmentalised panel board made out of 3mm thick CRCA sheet steel enclosure factory made powder coated suitable for dust and vermin proof with frame made of MS angle iron 50x50x6mm both rear and front operated doors provision for machanical and electrical interlocking arrangement suitable for 3 phase 415 Volts AC 50 Hz power supply with and including the following:-( For Lift machine room )\n(a) MCCB 63 Amps 3 pole 25 KA - 01 Nos(01 for lift)\n(b) LED indication lamps compact type (R,Y,B) -01 set \n\nNote : The quantity mentioned in column "Quantity" will be issued to the contractor under Sch B-1 'Free for Fixing'.\n\n\n\n. BI01010001010000000000000515BI0100001203 8 Job
95 94 Sl No 65 : Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire 4 mm dia (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 3 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel 15mm dia light grade for protection of earth electrode and 20mm dia GI pipe for watering all as speicified and directed and tested on completion. BI01010001010000000000000515BI0100001204 35 Each Set
96 95 Sl No 66 : Laying only XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade of following sizes complete all as specified and directed. Note: Cable will be issued under Sch 'B' free for laying only BI01010001010000000000000515BI0100001205
97 96 (a) 3.5 Core x 400 sqmm BI01010001010000000000000515BI0100001206 380 Running Meter
98 97 (b) 3.5 Core x 300 sqmm BI01010001010000000000000515BI0100001207 500 Running Meter
99 98 (c) 3.5 Core x 240 sqmm BI01010001010000000000000515BI0100001208 700 Running Meter
100 99 (d) 3.5 Core x 70 sqmm BI01010001010000000000000515BI0100001209 740 Running Meter
101 100 (e) 3.5 Core x 35 sqmm BI01010001010000000000000515BI0100001210 755 Running Meter
102 101 (f) 4 Core x 10 sqmm BI01010001010000000000000515BI0100001211 150 Running Meter
103 102 (g) 2 core x 16 sqmm BI01010001010000000000000515BI0100001212 3 Running Meter
104 103 (h) 3.5 core x 185 sqmm BI01010001010000000000000515BI0100001213 30 Running Meter
105 104 (j) 3.5 core x 50 sqmm BI01010001010000000000000515BI0100001214 50 Running Meter
106 105 (k) 4 core x 25 sqmm BI01010001010000000000000515BI0100001215 25 Running Meter
107 106 (l) 4 core x 16 sqmm BI01010001010000000000000515BI0100001216 1073 Running Meter
108 107 Sl No 67 : Loop in loop out thermoplastic cable junction boxes of size 250 x 250 x 100 mm made out of 1.6 mm thick MS sheet comprising of MCB SP 6A and 3 porcelain terminals as bus terminals for cable with necessary fixing arrangement, preparing the surface and applying two coats of synetic enamel paint over a coat of pimer complete all as directed.\n\n. BI01010001010000000000000515BI0100001217 15 Each
109 108 Sl No 68 : Street light fittings Single Piece, Cast AluminiumWith Full Frame Glass Cover Integral Luminaires of model ( Cat No. BGEST 150 SV IP 65 FFG WOB of Bajaj or its equivalent in Philips/CG) and luminarie HPSV T 150W complete including all fixing arrangements to the steet light pole complete all as specified \n\n. BI01010001010000000000000515BI0100001218 15 Each
110 109 Sl No 69 : Taking down the existing LT cable of size 3.5 core 185 sqmm and relaying carefully complete all as directed.\n\n. BI01010001010000000000000515BI0100001219 150 Running Meter
111 110 Sl No 70 : Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½ core XLPE armoured aluminium conductor cable of size 185 sq mm complete all as directed. BI01010001010000000000000515BI0100001220 2 Each
112 111 Sl No 71 : 57 degree CQBD with required fittings all as per standard practice and as directed with the following specifications\n(a) Material of construction - High tensile brass forging\n(b) Heat sensitive bulb - Quartzoid (dia 8 mm)\n(c) Deflector brass conforming to IS - 319\n(d) Test pressure - 30 Kg/sq cm \n(e) Working pressure - 12.4 Kg/sq cm\n(f) Bulb Temp, Tange & colour - 57 degree C/135 degree F, Orange\n(g) Finish - Brass/Nickle & chrome plated\n(h) Net weight - Not less than 150 Grams\n\n\n\n\n\n\n\n\n\n\n\n\n BI01010001010000000000000515BI0100001221 1455 Each
113 112 Sl No 72 : Mild steel pipe 150 mm bore medium grade including specials conforming to IS - 1239 part -I (1982) complete all as directed. BI01010001010000000000000515BI0100001222 22.9 Running Meter
114 113 Sl No 73 : Mild steel pipe 100 mm bore medium grade including specials conforming to IS - 1239 part -I (1982) complete all as directed. BI01010001010000000000000515BI0100001223 104.1 Running Meter
115 114 Sl No 74 : Mild steel pipe 80 mm bore medium grade including specials conforming to IS - 1239 part -I (1982) complete all as directed.\n\n. BI01010001010000000000000515BI0100001224 268.5 Running Meter
116 115 Sl No 75 : Mild steel pipe 50 mm bore medium grade including specials conforming to IS - 1239 part -I (1982) complete all as directed.\n\n. BI01010001010000000000000515BI0100001225 1603.9 Running Meter
117 116 Sl No 76 : Cast iron flanged sluice valve 150 mm dia class 1.6 PN complete all as specified. \n\n. BI01010001010000000000000515BI0100001226 5 Each
118 117 Sl No 77 :Cast iron flanged sluice valve 100 mm dia class 1.6 PN complete all as specified. \n\n. BI01010001010000000000000515BI0100001227 7 Each
119 118 Sl No 78 : Cast iron flanged sluice valve 80 mm dia class 1.6 PN complete all as specified. BI01010001010000000000000515BI0100001228 40 Each
120 119 Sl No 79 : Fire alarm valve 80 NB with required fittings all as per standard and as directed Model A size, 80 NB maximum service 12 Bar (175 PSI), pressure threaded opening BSPT (NPT-optional), mounting verticle flange connection ANSL B 161 FF # 125 (optional IS 1538) TRIM Steel with brass valves, factory hydrostatic 25 kg/ sq mm (335 PSI) test pressure frictional loss 80 NB-6.46 Mtr (21.2 ft) of pipe approximate net weight with out trim 80 NB 32 kg, finish - fire red epoxy painted approval UL listed reference NEPA 13 and NEPA 25 complete all as directed. BI01010001010000000000000515BI0100001229 50 Each
121 120 Sl No 80 : 16 zone UL certified microprocessor based fire alarm panel with TCP-IP provision and zone wise hooters as per IS-2189, 16 zone micro processor based fire alarm panel with 4x20 Alpha numeric LCD display, event logging, real time clock & RS-485 port to connect repeater panel via 4 wires key board programming with pass word locking, provision of RS-232/485 for LAN connection, event storage painted red along with relay contact for public address system. Make : Ravel/Vijay/Notifier BI01010001010000000000000515BI0100001230 3 Each
122 121 Sl No 81 : 06 zone UL certified microprocessor based fire alarm panel with TCP-IP provision and zone wise as per IS-2189, 06 zone micro processor based fire alarm panel with 4x20 Alpha numeric LCD display, event logging, real time clock & RS-485 port to connect repeater panel via 4 wires key board programming with pass word locking, provision of RS-232/485 for LAN connection, event storage, painted red along with relay contact for public address system. Make : Ravel/Vijay/Notifier BI01010001010000000000000515BI0100001231
123 122 Sl No 82 : Multi zone microprocessor based master fire alarm panel with 4x20 Alpha numeric LCD display, event logging, real time clock & RS - 485 port to connect panel via 2 wires, key board programming with pass word locking, provision of RS - 232/485 for LAN connection, event storage, painted red along with auto dialer to inter connect control room to fire station complete all as directed. Make : Ravel/Vijay/Notifier \n. BI01010001010000000000000515BI0100001232 1 Each
124 123 Sl No 83 : Public address system along with centralized communication system at control room complete all as directed.\n\n. BI01010001010000000000000515BI0100001233 1 Each
125 124 Sl No 84 : Heat/smoke detector ionization/ photoelectric type along with required base and junction boxes complete all as directed. \nMake : Appollo/System sensor/Notifier\n\n. BI01010001010000000000000515BI0100001234 161 Each
126 125 Sl No 85 : Manual call points/break glass switches with LED indication, die cast aluminium round type complete all as directed. \nMake : Ravel/Vijay/Notifier \n. BI01010001010000000000000515BI0100001235 44 Each
127 126 Sl No 86 : Electronic type dual type hooters 100 db complete all as directed. Make : Ravel/Vijay/Notifier BI01010001010000000000000515BI0100001236 44 Each
128 127 Sl No 87 : 1.5 sq mm 2 core armoured copper cable as per IS 1554 including wall mounting/ceiling mounting with saddles, clamps, screws, junction boxes steel conduit and required cable gland with necessary earthing complete all as directed. BI01010001010000000000000515BI0100001237 2700 Running Meter
129 128 Sl No 88 : Horizontal double mounting type single phase 220/250 volts, 6000 RPM, 500 C/s HP 1/4, range 1.5 KM including necessary cabling complete all as directed. Make : Kheraj/Target BI01010001010000000000000515BI0100001238 1 Each
130 129 Sl No 89 : Cast iron flanged non return valve 150 mm dia complete all as directed. BI01010001010000000000000515BI0100001239
131 130 Sl No 90 : Cast iron flanged non return valve 100 mm dia complete all as directed.\n\n. BI01010001010000000000000515BI0100001240
132 131 Sl No 91 : Fire hydrant valve type A (single outlet) of 63 mm dia conforming to IS - 5290 complete all as directed.\n\n. BI01010001010000000000000515BI0100001241 49 Each
133 132 Sl No 92 : 36 metres long first aid hose reel drum full swing of 18 mm bore as per IS - 884-1985 complete with control and 4.6 mm aluminium nozzle fitted along with enclosure and isolation ball valve complete all as directed. Make : Padmini/CRC\n\n. BI01010001010000000000000515BI0100001242 39 Each
134 133 Sl No 93 : Fire fighting hose 2 x 15 metres long conforming to IS - 636 complete with male and female coupling with copper wire winding conforming to IS - 903 complete all as directed. Make : Padmini/CRC\n\n. BI01010001010000000000000515BI0100001243 49 Each
135 134 Sl No 94 : Hose cabin of size 30"x24"x10" suitable for 2 Nos hose wall/base mounting type fabricated out of mild steel sheet 3 mm thick having glass front door with locking arrangement complete all as directed. BI01010001010000000000000515BI0100001244 49 Each
136 135 Sl No 95 : 63 mm gun metal branch pipe and nozzle conforming to IS - 903 complete all as directed. Make : Winco/AAG BI01010001010000000000000515BI0100001245 49 Each
137 136 Sl No 96 : Testing and commissioning of Horizontal electric driven centrifugal pump of 2850 LPM, 1500 RPM, 70 metres head including PCC foundation complete all as directed. (Main pump) \nNote :- The pump has been supplied by the previous contractor and installed at site. Testing and commissioning of this pump has to be completed alongwith any repair work required for making it functional to the entire satisfaction of Engr-in-Charge . The quoted rates are deemed to be inclusive of this and nothing extra is payble to the contractor on any pretext. BI01010001010000000000000515BI0100001246 1 Set
138 137 Sl No 97 : Testing and commissioning of Horizontal electric driven centrifugal pump of 180 LPM, 2900 RPM, 70 metres head including PCC foundation complete all as directed. (Jockey pump) . \nNote :- The pump has been supplied by the previous contractor and installed at site. Testing and commissioning of this pump has to be completed alongwith any repair work required for making it functional to the entire satisfaction of Engr-in-Charge . The quoted rates are deemed to be inclusive of this and nothing extra is payble to the contractor on any pretext. BI01010001010000000000000515BI0100001247 1 Set
139 138 Sl No 98 : Fixing only Exhaust fan 300mm sweep heavy duty single phase, 230 volts, 50 Hz AC supply including louver shutters all as specified. \nNote : Exhaust Fan will be issued under Schedule 'B' free for fixing only.\n\n. BI01010001010000000000000515BI0100001248 356 Each
140 139 Sl No 99 : Testing and commissioning of Horizontal diesel driven centrifugal pump of 2850 LPM, 1500 RPM, 70 metres head including PCC foundation complete all as directed. \nNote :- The pump has been supplied by the previous contractor and installed at site. Testing and commissioning of this pump has to be completed alongwith any repair work required for making it functional to the entire satisfaction of Engr-in-Charge . The quoted rates are deemed to be inclusive of this and nothing extra is payble to the contractor on any pretext. \n BI01010001010000000000000515BI0100001249 1 Set
141 140 Sl No 100 :PLC controlled panel board (main) made out of CRCA sheet 2 mm thick, factory made powder coated, indoor cubical type totally enclosed front operating, hinged doors with projected and raised platform of suitable size weather and water proof with necessary locking arrangement as per IS 8623 copper bus bar with half neutral insulators suitable for 3 phase 4 wire LT AC, 50 Hz 415 volts 300 Amps capacity, necessary internal electric connections with and including the following:- \n(a) MCCB 4 pole 415 volts, 200 amps 35 KA-01 No.\n(b) MCCB 3 pole 415 volts, 63 amps 10 KA-01 No.\n(c) MCCB TPN 415 volts, 30 amps -01 No.\n(d) Star delta starter 25 HP/10 HP -01 No each\n(e) Auto/Manual start provision with indications\n(f) Voltmeter/Ammeter of suitable capacities with selector switches & CTs\n\n\n\n\n\n\n\n\n\n\n. BI01010001010000000000000515BI0100001250
142 141 Sl No 101 : Diesel driven pump auto control panel 180 AH batteries (02 in Nos of 12 volt 180 AH battery maintenance Free type)\n\n. BI01010001010000000000000515BI0100001251 1 Set
143 142 Sl No 102 : Cast iron foot valve 150 mm dia complete all as directed. BI01010001010000000000000515BI0100001252
144 143 Sl No 103 : Cast iron foot valve 100 mm dia complete all as directed. BI01010001010000000000000515BI0100001253
145 144 Sl No 104 : Water pressure gauge standard dia at the delivery side of pump sets complete with connecting tubing fitted with stop cocks etc as per standard practice complete all as directed. BI01010001010000000000000515BI0100001254
146 145 Sl No 105 : Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth lead of 25x6 mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel 32mm dia light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion. BI01010001010000000000000515BI0100001255 30 Each Set
147 146 Sl No 106 : Electrically operated water pressure switch with necessary mounting/connection with control wiring with conductor and mechanical connection to operate at pressure range 0 to 10 Kg/Sqcm for automation complete all as directed.\n\n BI01010001010000000000000515BI0100001256 3 Each
148 147 Sl No 107 : 150mm dia 4 way fire brigade inlet without isolation valve and with instantaneous GM couplings, 63mm dia with required fittings all as directed.\n\n BI01010001010000000000000515BI0100001257 3 Each
149 148 Sl No 108 : Testing and commissioning only of Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 315 kVA 3 phase 4 wire engine , 0.8 power factor 50 Hz, 1500 RPM with relay panel for automatic starting on mains failure ,control panel having meters and conforming to IS 4722, BS 5514/2613/5000 with and including the following:-\n(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design\n(ii) Rate quoted shall be deemed to be inclusive of cable and terminations from Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed and including necessary foundation as per manufacturers instructions for the DG set.\n(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test\n(iv) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overload in presence of representative detailed by Accepting Officer, all arrangements are to be made by the contractor for tests\nNote :- The DG Set has been supplied by the previous contractor and installed at site. Testing and commissioning of this DG Set has to be completed alongwith any repair work required for making it functional to the entire satisfaction of Engr-in-Charge . The quoted rates are deemed to be inclusive of this and nothing extra is payble to the contractor on any pretext. \n\n\n\n\n\n\n\n\n. BI01010001010000000000000515BI0100001258 1 Each
150 149 (A). Alternator :- Standard design alternator rated at 315 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722\ni) Insualation class - 'H‘\nii) Temparature rise Class - 'H‘\niii) Excitation : Self Excited\niv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5%\nv) Frequency regulation +/- 1%\n BI01010001010000000000000515BI0100001259
151 150 (B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-\ni) Fly wheel with housing\nii) Cooling system :- Moulded radiator with fan & belts\niii) Cooling Water pump : - Centrifugal type belt driven\niv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.\nExhaust gas turbo charger type. Exhaust manifold\nSilencer : Residual type Bellows\n\n\n BI01010001010000000000000515BI0100001260
152 151 v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses.\nvi) Lub oil System :\nLubricating oil filter\nLubricating oil pump\nvii) Air Intake System :\nAir intake Manifold\nAir cleaner dry type\nviii) Governor :- Electronic Governor\nix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator\nx) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch\n\nHandling and operation : Salient features of accessories shall be as under:\nRadiator with blower fan\nCorrosion inhibitor coolant\nPaper element filters for fuel, lub oil and by pass\nElectronic governor controlled direct fuel injection system\nFly wheel housing and fly wheel BI01010001010000000000000515BI0100001261
153 152 xi) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice igniton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display.\nxii) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine\nxiii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling\nxiv) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames.\nxv) Base Frame : - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes\nxvi) Fuel Tank :- Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the accoustic enclosure in the sub staion building.\nxvii) MS pipe line to and from the fuel tank to the DG Set BI01010001010000000000000515BI0100001262
154 153 C) AMF Panel :- Factory made indoor type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 315 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard fitting shall be as follows:-\na) Digital Ammeter with selector switch of suitable capacity with CTs - 1 set\nb) Digital Volt meter with selector switch of 0 to 500 volts - 1 Set\nc) Digital Frequency meter - 1 No\nd) Digital KW meter - 1 No\ne) Digital KWH meter panel mounted type - 1 No\nf) Digital PF meter - 1 No\ng) Annuciation with indication lamps for :\n (i) Low lub oil pressure.\n (ii) High Water Temparature.\n (iii) Engine over speed.\n (iv) Battery low voltage\n BI01010001010000000000000515BI0100001263
155 154 Controls :-\na) Load on Indication\nb) Load off indication\nc) Engine start push button\nd) Engine stop push button\ne) Fault accept / reset push button\nf) Battary Charger :\n (i) Transformer\n (ii) Rectifier\n (iii) Resistance\n (iv) DC Volt meter\n (v) DC Ammeter\n (vi) Charger rate selector switch BI01010001010000000000000515BI0100001264
156 155 D) Accoustic Enclosure:- Manufactured by OEM suitable for 125 KVA DG Set\n (i) NAL approved as per CPCB\n(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board\n(iii) The generating set batteries and control panel should be inside the enclosure.\n(iv) Fuel tank should be out side the enclosure in the sub station building.\n(v) Construction Details/specification are as follows:\na) Outer body :- CRCA Sheet of 1.6mm thick\nb) Doors :- CRCA sheet of 1.6 mm thick\nc) Sound Insulation :- 100 mm thick rock wool (64kg/Cum)\nvi) The accoustic should be composite in construction and fully assembled integral unit\nvii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form\nviii) The fuel tank is to be located in Sub Station Building and cost of the fuel lines is deemed to be included in the offer.\nix) The DG Set should be provided with external Emergency stop push button\nx) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings.\nxi) The noise level should be 75 dba at 1m under free field conditions.\nxii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade. BI01010001010000000000000515BI0100001265
157 156 Sl No 109 : Terrace pump 450 ltrs per minute with minimum pressure of 3 Kg/sqm coupled with an electric motor with complete connections located on terrace connected to terrace tank with non return valve on delivery side, starting of terrace pump shall be automatic with pressure switch incorporated complete all and as directed BI01010001010000000000000515BI0100001266 3 Each
158 157 Sl No 110 : PVC insulated PVC sheathed cable galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area 2.5 sq mm 3 core fixed on walls/roofs with saddles etc complete all specified and directed. BI01010001010000000000000515BI0100001267 275 Running Meter
159 158 Sl No 111 : Aviation obstruction LED type fixed on and including GI pipe medium grade on top of roof complete all as directed. Make : Philips/ Bajaj/ Havella/K-lite BI01010001010000000000000515BI0100001268 3 Each
160 159 Sl No 112 : Sheet metal enclosure for DBs single pole & neutral 1 way with our bus bar 240 V complete all as specified. BI01010001010000000000000515BI0100001269 3 Each
161 160 Sl No 113 : MCB SPN 240 V, 5 to 30 Amps complete all as specified. BI01010001010000000000000515BI0100001270 3 Each
162 161 Sl No 114 : Transformer step down 11/0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continuous rating of 630 kVA indoor type conforming to IS 2026 with and including the following:- \n(a) Lifting lugs/hooks for transformer and tank \n(b) Earthing terminal rating and diagram plate.\n(c) Air release device.\n(d) Oil filling inlet pipe with plug\n(e) Drain outlet pipe with brass gate valve with dummy plug\n(f) Conservator with level gauge\n(g) Silica gel breather\n(h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335\n(j) Type of connection : Delta/Star\n(k) Type of cooling : ONAN\n\n\n\n\n\n\n\n\n\n\n BI01010001010000000000000515BI0100001271 2 Each
163 162 (l) Vector Group : DYN 11\n(m) Type of connecting arrangement : Cable termination boxes on both HT and LT side\n(n) Temperature rise over an ambient of 50 degree centigrade maximum\n(o) Provision of thermometer with pocket\n(p) In addition to the above all standard fittings shall be provided as per IS norms \n\n BI01010001010000000000000515BI0100001272
164 163 Sl No 115 : Electro rubber mat 1000 x 2000 x 10mm all as specified. BI01010001010000000000000515BI0100001273 2 Each
165 164 Sl No 116 : Electro rubber mat 1000 x 2000 x 19mm all as specified. BI01010001010000000000000515BI0100001274 15 Each
166 165 Sl No 117 : Fire extinguisher DCP 5 Kg capacity BI01010001010000000000000515BI0100001275 2 Each
167 166 Sl No 118 : Fire buckets 10 ltrs capacity BI01010001010000000000000515BI0100001276 4 Each
168 167 Sl No 119 : Shock treatment chart board as per standard norms BI01010001010000000000000515BI0100001277 1 Each
169 168 Sl No 220 : Extra over rendering or plastering for arch elevation work in CM 1:2 50mm wide and 50mm thick all as directed. BI01010001010000000000000515BI0100001278 291 Running Meter
170 169 Sl No 221 : Extra over rendering or plastering for arch elevation work in CM 1:2 25mm wide and 25mm thick all as directed. BI01010001010000000000000515BI0100001279 156 Running Meter
171 170 Sl No 222 : Removal of 1300 bags of cement (unfit for onstruction activities) from the work site and disposal of the same outside MOD land or Coast Guard land complying the instructions of the local civil authorities in the matter all as directed. BI01010001010000000000000515BI0100001280 1 One Job
172 171 Schedule "A" Part - XVI (DEFECTIVE/PARTIALLY COMPLETED E/M ITEMS)\nNOTE:- The contractor who has undertaken the work under CA No CA No : CE(Navy)/Viz/14 of 2013-14 has not executed the items of work, given below , as per the scope given in the contract for the respective item of the work and has left it incomplete / partially executed. The contractor bidding now shall inspect the site of work and make themselves fully familiar about the quantum of work required to be done for successful completion of the respective item as per CA for its functional suitability, and quote their rates accordingly. The payment to the contractor now undertaking this work will be restricted to the rate/amount now quoted and nothing extra is admissible to them on pretext of any misunderstanding. Bidders are advised to go through Annexure 'H' , in addition to the site visit, before quoting their rates. BI01010001010000000000000515BI0100001281
173 172 Sl No 1 : Point wiring with 1.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral and earth continuity) drawn in concealed conduit including Provision of 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, electronic fan regulators and connecting the earth wire to common earth dolly for one light point controlled by one switch.\n(Serial item No 1 of Sch A Pt XV) BI01010001010000000000000515BI0100001282 365 Point
174 173 Sl No 2 : All as per Sl No.1 hereinbefore but one fan point controlled by one switch and regulator.\n(Serial item No 2 of Sch A Pt XV) BI01010001010000000000000515BI0100001283 114 Point
175 174 Sl No 3 : All as per Sl No.1 hereinbefore but for one exhaust fan point controlled by one switch.\n(Serial item No 3 of Sch A Pt XV) BI01010001010000000000000515BI0100001284 72 Point
176 175 Sl No 4 : All as per item No 1 hereinbefore but for 5 amps socket outlet on independent board.\n(Serial item No 5 of Sch A Pt XV) BI01010001010000000000000515BI0100001285 123 Point
177 176 Sl No 5 : Point wiring with 2.5 Sqmm (Nominal area) PVC insulated Unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral )and 1.5 sq mm cable for earth continuity) drawn in concealed conduit including Provision of 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches, electronic fan regulators and connecting the earth wire to common earth dolly for one 15 Amps power point on independent board.\n(Serial item No 7 of Sch A Pt XV) \n BI01010001010000000000000515BI0100001286 36 Point
178 177 Sl No 6 : Submain wiring in concealed PVC conduit with two runs of 2.5 sq mm and one run of 1.5 sqmm for earth continuity, 1100 v grade PVC insulated, unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS-694) drawn through and including 20 mm dia PVC rigid conduit heavy grade ISI marked (IS-9537, Part-III) including accessories such as bends, supports etc all as specified for building security lights. (Note: 2 runs of 2.5 sq mm cable and one run of 1.5 sq mm cable and 1 run of PVC conduit shall be measured as one unit). \n(Serial item No 12 of Sch A Pt XV) \n\n BI01010001010000000000000515BI0100001287 878.3 Running Meter
179 178 Sl No 7 : MCB DB SPN 8 way with 200 amps 240 V rated copper busbar in sheet steel enclosure double door type complete all as specified.\n(Serial item No 21 of Sch A Pt XV).\n\n BI01010001010000000000000515BI0100001288 35 Each
180 179 Schedule "A" Part - XVII (DEFECTS RECTIFICATION B/R ITEMS)\nNOTE:- The contractor who has undertaken the work under CA No CA No : CE(Navy)/Viz/14 of 2013-14 has executed the items of work, given below , but defects have cropped up due to poor workmanship for the respective item of the work. The contractor bidding now shall inspect the site of work and make themselves fully familiar about the quantum of work required to be done for successful completion of the respective item as per CA for its functional suitability, and quote their rates accordingly. The payment to the contractor now undertaking this work will be restricted to the rate/amount now quoted and nothing extra is admissible to them on pretext of any misunderstanding. BI01010001010000000000000515BI0100001289
181 180 Sl No 1 : PVC waste pipe found broken at certain places need to be replaced to the satisfaction of Engr-in-Charge. \n(Block No 1 of Type II & III) BI01010001010000000000000515BI0100001290 2 Nos
182 181 Sl No 2 : Hair line cracks found in plaster at 04 different locations need to be corrected to the satisfaction of Engr-in-Charge.\n(Block No 1 of Type II & III, Block No 2 of Type II and Near substation and Pump house area) BI01010001010000000000000515BI0100001291 9 Square meter
183 182 Sl No 3 : Rebates of door frame not finished properly and required to be done to the satisfaction of Engr-in-Charge.\n(Block No 1 of Type II & III) BI01010001010000000000000515BI0100001292 3 Nos
184 183 Sl No 4 : Honey combing in RCC parapet wall at certain places needs to be rectified to the satisfaction of Engr-in-Charge. \n(Block No 2 of Type II) BI01010001010000000000000515BI0100001293 2 Square meter
185 184 Sl No 5 : Surface of RCC work not finished properly at certain places needs to be rectified to the satisfaction of Engr-in-Charge.\n(Block No 2 of Type II) \n BI01010001010000000000000515BI0100001294 3 Square meter
186 185 Sl No 6 : Welding of the gate not done properly and needs to be rectified to the satisfaction of Engr-in-Charge.\n(Near substation and Pump house area) \n\n BI01010001010000000000000515BI0100001295 1 Job
187 186 Sl No 7 : Rolling shutter not painted needs to be painted as per Sch of finishes to the satisfaction of Engr-in-Charge.\n(Near substation and Pump house area) \n\n. BI01010001010000000000000515BI0100001296 1 Job
188 187 Sl No 8 : Plinth protection found damaged/broken needs to be rectified to the satisfaction of Engr-in-Charge. \n(Near substation and Pump house area) BI01010001010000000000000515BI0100001297 1 Square meter
189 188 Sl No 9 : Joints in plinth protection not filled properly with filler, needs to be rectified to the satisfaction of Engr-in-Charge.\n(Near substation and Pump house area) BI01010001010000000000000515BI0100001298 15 Running Meter
190 189 Sl No 10 : Edges of RCC slab of UG Sumps (2 Nos) found broken at places, needs to be rectified to the satisfaction of Engr-in-Charge.\n(Near substation and Pump house area) BI01010001010000000000000515BI0100001299 2 Running Meter
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail