Repair Maintenance Of Lt Control Panels Acbs Mccbs Ug Cables At Af Stn Naliya, GE (AF) Naliya NO 01-Gujarat

Military Engineer Services-MES has published Repair Maintenance Of Lt Control Panels Acbs Mccbs Ug Cables At Af Stn Naliya. Submission Date for this Tender is 02-11-2020. Circuit Breakers Tenders in GE (AF) Naliya NO 01 Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

25720676
Repair Maintenance Of Lt Control Panels Acbs Mccbs Ug Cables At Af Stn Naliya
Open Tender
Indian
Gujarat
GE (AF) Naliya NO 01
02-11-2020

Tender Details

Repair Maintenance Of Lt Control Panels Acbs Mccbs Ug Cables At Af Stn Naliya

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: REPAIR/ REPLACEMENT OF LT UG CABLE/OH LINES, LT POLES, CONTROL PANELS BOARD, CHANGE OVER SWITCHES AND ALLIED ITEMS AT AF STN NALIYA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft / loose soil for laying of under ground electric cable, pipes etc complete all as specified and as directed.\nNote:(i) Authorised width & depth shall only be excavated. Measurements and payment shall be as specified in clause 3.2.3 of SSR part II 2010 and 19.74.1 of SSR part I for cable / pipe laying portion.\n(ii) Serviceable PCC / RCC cable covers,shall be taken up from the trench obtained during excavation shall be stacked separately carefully without any extra cost to the Deptt for re-use in the work.\n BI01010001010000000000000515BI0100001113 950.4 Cum
2 2 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and as directed. BI01010001010000000000000515BI0100001114 569.05 Cum
3 3 Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and as directed. BI01010001010000000000000515BI0100001115 381.35 Cum
4 4 M & L for river bed sand filling in trenches / ducts 15 cm above cable and 8 cm under the cable for cushioning / protection to cable including spreading, leveling and punned to get thickness upto 18cm by hand punning complete all as specified and as directed.\nNote: Punned thickness only shall be measured and paid. 285.12 Cum
5 5 Laying only serviceable un-reinforced precast concrete cable cover class LV, Type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over under cable for protection breadth of cable cover parallel to length of cable complete all as specified and as directed. 13200 Each
6 6 Supply & lay un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over under cable for protection breadth of cable cover parallel to length of cable complete all as specified and as directed. 8800 Each
7 7 M& L for cutting under the road / pavement / hard standing or in any other situation with the manual labour for crossing of U/G cable through it and making both the end good complete all as specified and as directed . 80 RM
8 8 Taking out old unserviceable LT cable of any size, any type from trench / duct / poles / roof / pipe etc and keeping aside for segregation of serviceability \nNote : Serviceable cable shall be re-laid at same place or other place as required at site and shall be measured and paid under relevant item including labour. 4400 RM
9 9 Supply and lay, connecting XLPE insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100V grade, of size 16 Sqmm 2 core with proper size of lugs and laid in trenches / ducts / through GI pipe / fixed to poles etc complete all as specified and as directed \nNote: Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately under relevant item. 200 RM
10 10 All as per item No. 9 above but of size 25 Sqmm 2 Core 200 RM
11 11 All as per item No. 9 above but of size 16 Sqmm 4 core 700 RM
12 12 All as per item No. 9 above but of size 25 Sqmm 4 core 600 RM
13 13 All as per item No. 9 above but of size 35 Sqmm 3.5 core 400 RM
14 14 All as per item No. 9 above but of size 50 Sqmm 3.5 core 300 RM
15 15 All as per item No. 9 above but of size 95 Sqmm 3.5 core 200 RM
16 16 Laying of old serviceable cable of up to 185 sqmm obtained from taking up vide items here in above complete all as specified and as directed. 800 RM
17 17 Laying only LT cable of 185/240/300Sqmm size obtained from taking up vide items here in above complete all as specified and as directed. 1000 RM
18 18 Supply & erect Prestressed concrete pole, 9.0 metre long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complete all as specified and as directed.\nNote : Excavation, earth work and PCC shall be measured and paid separately under relevant item. 5 Each
19 19 M&L for Cement concrete in pole foundations, coping, filling and mass concrete, in PCC 1:3:6 type C2 (by using 40mm graded stone aggregate) including dismantling old PCC etc complete all as specified and as difrected. 1 Cum
20 20 Taking down old ACSR conductor including guard wire, GI earth wire, Stay wire and insulators of any size from existing poles etc complete all as specified and as directed. 1.5 Qtl
21 21 Supply, fix and testing LT cable jointing kit straight through heat shrinkable type suitable for cable PVC / XLPE insulated armoured heavy duty aluminum conductor 1100V grade LT cable of size 3.5 / 4 core 35 to 50 sqmm complete all as specified and as directed. 10 Each
22 22 Supply, fix and test LT cable jointing kit straight through heat shrinkable type suitable for cable PVC / XLPE insulated armoured heavy duty aluminum conductor 1100V grade LT cable of size 3.5 / 4 core 70 to 120 sqmm complete all as speicified and as directed. 5 Each
23 23 Supply, fix and test LT cable jointing kit straight through heat shrinkable type suitable for cable PVC / XLPE insulated armoured heavy duty aluminum conductor 1100V grade LT cable of size 3.5 / 4 core 150 to 300 sqmm complete all as specified and as directed. 3 Each
24 24 Supply & fix of MS CRCA sheet enclosure of 2mm sheet thickness duly painted, fixing arrangement for housing MCCB including supply and fixing MCCB of capacity 63 Amps, 10KA 4 pole, 415 volts with fixed thermal & magnetic settings including & connections of cables with thimbles / lugs and to existing DB etc complete all as specified and as directed. 5 Each
25 25 Supply & fix of MS CRCA sheet enclosure of 2mm sheet thickness duly painted, fixing arrangement for housing MCCB including supply and fixing MCCB of capacity 100 Amps, 16KA 4 pole, 415 volts with fixed thermal & magnetic settings including & connections of cables with thimbles / lugs and to existing DB etc complete all as specified and as directed. directed. 3 Each
26 26 Supply & fix of MS CRCA sheet enclosure of 2mm sheet thickness duly painted, fixing arrangement for housing MCCB including supply and fixing MCCB of capacity 200 Amps, 25KA 4 pole, 415 volts with fixed thermal & magnetic settings including & connections of cables with thimbles / lugs and to existing DB etc complete all as specified and as directed 2 Each
27 27 M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth wire connected to Plant/equipment and protected by galvanized iron or steel pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover 40mm thick with 6mm MS rods @ 150mm c/c both directions and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronze size 75x75x25 mm complete . Note : On testing after completion of earthing if desired earth resistance below 5 ohms is not achieved , the earthing shall be redone by the contractor at no extra cost to deptt. 10 Each
28 28 All as per item No. 27 above but of using 4mm dia GI wire as earthing lead and 20mm bore GI pipe light grade for earth protection for pole earthing. 10 Each
29 29 S & F in replacement MCCB's, 63 Amps, 415 Volts, 4 pole, fixed thermal & fixed magnetic settings complete all as specified and as directed. 5 Each
30 30 All as per item No. 29 above but of capcity 100 Amps 10 kA 4 Pole 5 Each
31 31 All as per item No. 29 above but of capcity 160 Amps 16 kA 4 Pole 2 Each
32 32 All as per item No. 29 abvoe but of capcity 200 Amps 25 kA 4 Pole 2 Each
33 33 All as per item No. 29 above but of capcity 250 Amps 36 kA 4 Pole 1 Each
34 34 All as per item No. 29 above but of capcity 400 Amps 36 kA 4 Pole 1 Each
35 35 M&L for welding work for fixing of panel board door, hinges, angles or any other plant and machinery on site by bringing welding machine and other welding materials complete all as specified and as directed. \nNote : The cost of Materials required for welding and transporting of welding machine on site shall be deemed to be included in item rate. 10 Each Job
36 36 M&L for preparing old painted surface of LT Panel board of any size by thoroughly and completely, cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth, priming the surface with anti corrosive primers using suitable sprayers and applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and complete all as specified and as directed.\n 10 Each Job
37 37 S&F auto / manual street light timer nature switch weather proof enclosure made out of UV stabilized, FR grade special molding compound, rust proof, electric sock proof, vermin proof outdoor pole mountable with mounting bracket made out of GI and nut, bolts, washers including cable glands, openable door of capacity 08 kW load, three phase with Power contactors 3nos as incoming and outgoing with MEC rating of 32 Amps/phase and including circuit wiring complete all as specified and as directed \n 2 Each
38 38 Supply and lay GI water tubing of 80 mm bore, light grade, IS-1239 with all fittings IS marked and laid in trenches/under roads/in drains with suitable size flat iron/GI clamps, bolts, nuts and washers etc for cable protection, complete all as specified and as directed. 18 RM
39 39 Supply and lay GI water tubing of 50 mm bore, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads / in drains, fixed to poles / walls with suitable size flat iron / GI clamps, bolts, nuts and washers etc for cable protection, complete all as specified and as directed. 60 RM
40 40 Supply and lay GI water tubing of 40 mm bore, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads / in drains, fixed to poles / walls with suitable size flat iron / GI clamps, bolts, nuts and washers etc for cable protection, complete all as specified and as directed. 36 RM
41 41 M&L for Compression / crimping type sleeve joints for jointing conductors / jumper connections including treatment with conducting jelly including taking out old jumpers of ACSR conductor overhead lines by un-winding of conductor 4/6 wire on both sides, dusting out powdered aluminum complete all as specified and as directed. 285 Each Job
42 42 Supply fabricate, testing and commissioning of factory made LT outdoor distribution panel board (Junction box) double door including locking arrangement cubical type dust proof, weather proof, vermin proof aesthetical designed, IP 54 degree of ingress protection, CPRI approved, fabricated from 3mm thick CRCA sheet with front and rear opening including bus bar chamber, including bus bar chamber, 3 strips of aluminum bus bar of 100 Amps current carrying capacity insulated with colour sleeves, porcelain / epoxy insulators, rail channel, cable entry, danger notice plate of 1100 Volt made out of 14 gauge MS sheet over angle iron frame of size 40x40x5mm and 60cm grouted in ground and 60cm above GL including necessary excavation, foundation, PCC etc. complete duly powder coated of approved colour complete all as specified and as directed.\n 5 Each
43 43 S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 volts grade complete all as specified and as drected 40 Each
44 44 S&F Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, 1100 volt grade of size 75 mm height and 90mm dia complete all as specified and as directed. 36 Each
45 45 S&F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed. 200 Each
46 46 Dismantling and taking down fluorescent tube light single / double of any wattage or size / street light fittings for repair or replacement of burnt / worn out accessories and re-fixing for street light fitting, for 70 / 80 / 125 / 150 watt vapour or sodium /T5, after taking out from one place complete with ballast and capacitor comprising of cast aluminium housing, a pair of aluminium reflectors, a highly transparent clear acrylic cover hinged to the canopy at one end and fixed by means of single spring action at the other, suitable for mounting on 40mm or 50mm dia. G.I. bracket arms with pole fixing attachments complete all as specified and as directed. 60 Each
47 47 S&F spacers / separator PVC with clamping nut bolts suitable for 2 wire complete all as specified and as directed 100 Each
48 48 S&F spacers / separator PVC with clamping nut bolts suitable for 4 wire complete all as specified and as directed 400 Each
49 49 Supply and fix maintenance free solar deep cycle batteries designed for long time back up of capacitry 12 volt 60 AH in 3 yrs warranty. 5 Each
50 50 Supply and fix mono / polycrystalline MNRE approved solar panels for solar lights of capacity 20 watt 12 volts suitable for 20 watt solar lights complete all as specified and as directed. 3 Each
51 51 Supply and fix solar lights 20 watt with all accessories suitable for solar panels for solar panels of capacity 20 watt with white lights complete all as specified and as directed. 4 Each
52 52 Supply, install, test and commission, factory made and tested , LT feeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc :- (a) Aluminum bus bar four strips 400 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set Incoming\n(b) MCCB, 04 Pole, 250 Amps with ultimate breaking capacity Icu- 35/36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No. outgoing\n(c) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity 10/16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 Nos\n(d) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity 10/16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I - 03 Nos\n(e) Volt meter 0-500 volt with coil and selector switch - 1No.\n(f) Ammeter 0-500 Amps with CT coil and selector switch - 01 No \n(g) Indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set \n(h) Space for MCCB 100A - 01 No\n(j) Platform for the panel with PCC 1:4:8 type D-2 ( by using 40mm graded crushed stone aggregates ), 15 cm thick in foundation, cemented block / brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the ground level. 1 Each
53 53 All as per srl item No 52 here-in-before but comprising of following:-\n(a) Aluminum bus bar four strips 400 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set Incoming\n(b) MCCB, 04 Pole, 300/315 Amps with ultimate breaking capacity Icu- 35/36 KA at 415 volts ,with fixed thermal & magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No. Outgoing\n(c) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity 10/16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I - 03 Nos\n(d) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity 10/16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 Nos\n(e) Digital Volt meter 0-500 volt with coil and selector switch - 1 No.\n(f) Digital ammeter 0-500Amps with CT coil and selector switch - 01 No\n(g) Indication lamps R,Y,B LED type with 3 Nos – 1 set \n(h) Space for MCCB 100A - 01 N0\n(j) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.\n(k) Platform for the panel with PCC 1:4:8 type D-2 (by using 40mm graded crushed stone aggregates), 15 cm thick in foundation, cemented block/brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the ground level. 1 Each