Repair Maintenance Of Different Type Capacity Of Centrifugal Submersible Pump Sets And Starter Panels At Af Stn Naliya, GE (AF) Naliya NO 01-Gujarat

Military Engineer Services-MES has published Repair Maintenance Of Different Type Capacity Of Centrifugal Submersible Pump Sets And Starter Panels At Af Stn Naliya. Submission Date for this Tender is 04-11-2020. Starter Tenders in GE (AF) Naliya NO 01 Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

25720100
Repair Maintenance Of Different Type Capacity Of Centrifugal Submersible Pump Sets And Starter Panels At Af Stn Naliya
Open Tender
Indian
Gujarat
GE (AF) Naliya NO 01
04-11-2020

Tender Details

Repair Maintenance Of Different Type Capacity Of Centrifugal Submersible Pump Sets And Starter Panels At Af Stn Naliya

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work : Repair/maintenance of different type/capacity of centrifugal/submersible pump sets and starter panels at AF stn Naliya.
Sl. No. Description of work Item Code / Make No. Or Qty Units
1 1 Disconnect the existing 60 HP, 3 Phase capacity the electric / water connections and removing centrifugal motor from base plate of pumpset and transporting motor to workshop to carryout repairs including replacement of any parts which are damaged and required to be replaced and bringing back after repair, servicing etc and refixing in its original position, testing and commissioning complete all as specified and as directed 4 Each Job
2 2 All as per Item No. 1 above but 35 to 40 HP , 3 Phase capacity 6 Each Job
3 3 All as per Item No.1 above but 15 HP , 3 Phase capacity 1 Each Job
4 4 All as per Item No.1 above but 10 HP , 3 Phase capacity 2 Each Job
5 5 Disconnect the existing 5 HP, 3 Phase capacity electric /water connections and removing centrifugal monoblock pumpset from any type existing location, and transporting motor to workshop to carryout repairs including replacement of any parts which are damaged and required to be replaced and bringing back after repair, servicing etc and refixing in its original position, testing and commissioning complete all as specified and as directed. 3 Each Job
6 6 All as per Item No.5 above but 2 HP, 1 Phase capacity 3 Each Job
7 7 All as per Item No.5 above but 1 HP, 1 Phase capacity 4 Each Job
8 8 All as per Item No.5 above but 0.25 to 0.50 HP , 1 Phase capacity\nNote for Item No. 1 to 8 : - The parts, winding etc replaced if any shall be measured and paid separately as supply only under relevant item. 4 Each Job
9 9 M & L in repairs for rewinding of induction motor of 60 HP , 3 Phase capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size / turns, varnishing with class 'B' insulation assembling the motor complete testing at workshop complete all as specified and as directed. 4 Each Job
10 10 All as per Item No.9 above but 35 to 40 HP , 3 Phase capacity 4 Each Job
11 11 All as per Item No.9 above but 15 HP , 3 Phase capacity 1 Each Job
12 12 All as per Item No.9 above but 10 HP , 3 Phase capacity 4 Each Job
13 13 M & L in repairs for rewinding of centrifugal monoblock pumpset of 5 HP, 3 Phase capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size/turns, varnishing with class 'B' insulation assembling the motor complete testing at workshop complete all as specified and as directed. 3 Each Job
14 14 All as per Item No.13 above but 2 HP, 1 Phase capacity 3 Each Job
15 15 All as per Item No.13 above but 1 HP, 1 Phase capacity 4 Each Job
16 16 All as per Item No.13 above but 0.25 to 0.50 HP , 1 Phase capacity 4 Each Job
17 17 S & F in repairs ball bearing in centrifugal motor of 60 HP , 3 Phase capacity after taking out broken/wear and tear unserviceable baering complete all as specified and as directed 6 Each Job
18 18 All as per Item No.17 above but 35 to 40 HP , 3 Phase capacity 6 Each Job
19 19 All as per Item No.17 above but 15 HP , 3 Phase capacity 2 Each Job
20 20 All as per Item No.17 above but 10 HP , 3 Phase capacity 6 Each Job
21 21 S & F in repairs ball bearing in centrifugal monoblock pump sets of 5 HP, 3 Phase capacity after taking out broken/wear and tear unserviceable bearing complete all as specified and as directed 3 Each Job
22 22 All as per Item No.21 above but 2 HP, 1 Phase capacity 3 Each Job
23 23 All as per Item No.21 above but 1 HP, 1 Phase capacity 4 Each Job
24 24 All as per Item No.21 above but 0.25 to 0.50 HP , 1 Phase capacity 4 Each Job
25 25 Supply and fix of CI sleeve in bearing housing of 60 HP , 3 Phase capacity centrifugal motor complete all as specified and as directed 2 Each
26 26 All as per Item No.25 above but 35 to 40 HP , 3 Phase capacity 2 Each
27 27 All as per Item No.25 above but 15 HP , 3 Phase capacity 2 Each
28 28 All as per Item No.25 above but 10 HP , 3 Phase capacity 1 Each
29 29 Supply and fixing of terminal connection plate for 60 HP , 3 Phase capacity C/F Motor complete all as specified and as directed 3 Each
30 30 All as per Item No.29 above but 35 to 40 HP , 3 Phase capacity 2 Each
31 31 All as per Item No.29 above but 15 HP , 3 Phase capacity 2 Each
32 32 All as per Item No.29 above but 10 HP , 3 Phase capacity 1 Each
33 33 Supply and fix of terminal box for 60 HP , 3 Phase capacity C/F Motor complete all as specified and as directed 3 Each
34 34 All as per Item No.33 above but 35 to 40 HP , 3 Phase capacity 2 Each
35 35 All as per Item No.33 above but 15 HP , 3 Phase capacity 2 Each
36 36 All as per Item No.33 above but 10 HP , 3 Phase capacity 1 Each
37 37 Supply and fix bearing plate & bolt of bearing plate size 8 x 100 mm complete all as specified and as directed 50 Nos
38 38 Disconnecting electric/water connection and removing centrifugal pump 60 HP , 3 Phase capacity from base plate of pumpset and transporting pump to workshop to carry out repair and bringing back after carrying out repair, servicing etc and refixing in its original position , testing and commissioning complete all as specified and as directed 4 Each Job
39 39 All as per Item No.38 above but 35 to 40 HP , 3 Phase capacity 4 Each Job
40 40 All as per Item No.38 above but 15 HP , 3 Phase capacity 1 Each Job
41 41 All as per Item No.38 above but 10 HP , 3 Phase capacity 2 Each Job
42 42 Supply and fix,coupling flexible cushion I/C making bore and key way complete Set with tyre, nut bolts etc,type TC/P/011, 2 Each Set
43 43 All as per Item No.42 above but type TC/P/013 2 Each Set
44 44 All as per Item No.42 above but type TC/P/014 4 Each Set
45 45 All as per Item No.42 above but type TC/P/015 4 Each Set
46 46 All as per Item No.42 above but type TC/P/017 4 Each Set
47 47 All as per Item No.42 above but type TC/P/018 4 Each Set
48 48 Supply and fix spare tyre for coupling Type TC/P/011 to TC/P/017 all as per existing size and make required at site , complete all as specified and directed. 10 Each
49 49 S & F in repair stainless steel shaft of centrifugal pump of 60 HP , 3 Phase capacity after taking out broken/wear and tear unserviceable shaft as per the sample and existing type and size complete all as specified and as directed. 2 Each Job
50 50 All as per Item No.49 above but 35 to 40 HP , 3 Phase capacity 4 Each Job
51 51 All as per Item No.49 above but 15 HP , 3 Phase capacity 1 Each Job
52 52 All as per Item No.49 above but 10 HP , 3 Phase capacity 1 Each Job
53 53 S & F in repairs ball bearing in centrifugal pump of 60 HP , 3 Phase capacity after taking out broken/wear and tear unserviceable baering complete all as specified and as directed. 10 Each Job
54 54 All as per Item No.53 above but 35 to 40 HP , 3 Phase capacity 6 Each Job
55 55 All as per Item No.53 above but 15 HP , 3 Phase capacity 3 Each Job
56 56 All as per Item No.53 above but 10 HP , 3 Phase capacity 3 Each Job
57 57 S & F in repairs impeller in centrifugal pump of 60 HP , 3 Phase capacity after taking out broken/wear and tear unserviceable impeller as per the sample and existing size complete all as specified and as directed. 2 Each Job
58 58 All as per Item No.57 above but 35 to 40 HP , 3 Phase capacity 2 Each Job
59 59 All as per Item No.57 above but 15 HP , 3 Phase capacity 1 Each Job
60 60 All as per Item No.57 above but 10 HP , 3 Phase capacity 1 Each Job
61 61 Supply only CI casing wear ring DE/NDE spare part for centrifugal pump set of 35 to 60 HP 4 Each
62 62 All as per Item No.61 above but CI Interstage Ring 4 Each
63 63 All as per Item No.61 above but CI stuffing box bush 4 Each
64 64 All as per Item No.61 above but CI gland plate 4 Nos
65 65 All as per Item No.61 above but Lentern Ring 6 Each
66 66 All as per Item No.61 above but Eye bolt with Nut 10 Each
67 67 All as per Item No.61 above but CI shaft sleeve 6 Each
68 68 All as per Item No.61 above but Gasket packing sheet 4 Set
69 69 All as per Item No.61 above but Gland packing champion 6 Set
70 70 All as per Item No.61 above but Remetling of pump shaft turning and balancing 4 Job
71 71 All as per Item No.61 above but Impeller Key 4 Nos
72 72 All as per Item No.61 above but Coupling Key 4 Nos
73 73 All as per Item No.61 above but Water liquid Defletor 8 Nos
74 74 All as per Item No.61 above but CI bearing cartiage DE/NDE 4 Nos
75 75 All as per Item No.61 above but CI bearing Plate 4 Nos
76 76 All as per Item No.61 above but Coupling nut 4 Nos
77 77 All as per Item No.61 above but MS stud with nut 24 Nos
78 78 All as per Item No.61 above but G.M Impeller nut 4 Nos
79 79 Taking out of any capacity submersible pump set carefully from bore well alongwith existing submersible cable MS/GI/HDPE, Column pipe of dia 80mm/ 100mm , flanged type , 3 meters each length (depth of submersible pump is 80 m to 115 m) and shifting column pipe , pumpset and submersible cable aside for reuse and lowering into bore well after repair work including of submersible cable jointing initial pump set testing binding of submersible cable with column pipe by using aluminium wire complete and final testing complete all as specified and as directed.\nNote :- (i) The quoted rate deemed to be included the cost of rubber gaskets, nuts, bolts , washers aluminium wire etc.\n(ii) Any damage to pump set column pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GE's decision shall be final and binding in this regard. 16 Each Job
80 80 Complete opening of submersible bore well pump set of 40 HP/30 HP/27.5 HP capacity for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc , including re-assembling and testing complete all as specified and as directed.\nNote :- (i) Cost of transportation of pump set from site to workshop and back to site after repair is deemed to be included in the quoted rate.\n(ii) Repair/replacement of parts/winding shall be measured and paid separately. 12 Each Job
81 81 M & L in repairs for rewinding of submersible bore well motor of 40 HP capacity by means of cutting and removing existing burnt out winding completely , cleaning and repair of slots and rewinding with new copper wire of existing gauge and size /turns, varnishing assembling the motor complete testing at workshop complete all as specified and as directed 5 Each Job
82 82 All as per Item No.81 above but 30 HP capacity 3 Each Job
83 83 All as per Item No.81 above but 27.5/25 HP capacity 2 Each Job
84 84 Supply only Bearing bush for submersible Pump set of capacity 25 HP to 40 HP. 8 Nos
85 85 All as per Item No.84 above but Rotar Sleeve 8 Nos
86 86 All as per Item No.84 above but Water seal and cable seal 10 Nos
87 87 All as per Item No.84 above but Thrust bearing 10 Nos
88 88 All as per Item No.84 above but Revolving Disc 4 Nos
89 89 All as per Item No.84 above but CI Connection piece 4 Nos
90 90 All as per Item No.84 above but Motor sand guard 4 Nos
91 91 All as per Item No.84 above but Sealing ring 4 Nos
92 92 All as per Item No.84 above but CI upper housing 6 Nos
93 93 All as per Item No.84 above but CI Lower housing 6 Nos
94 94 All as per Item No.84 above but Rotar Sleeve turming and polishing 4 Job
95 95 All as per Item No.84 above but Remetling of Rotar end turming and making key way 4 Job
96 96 All as per Item No.84 above but Repairing of starter stamping 4 Job
97 97 All as per Item No.84 above but Seal bush 4 Nos
98 98 All as per Item No.84 above but CI Motor Base 4 Nos
99 99 All as per Item No.84 above but Thrust plate 6 Nos
100 100 All as per Item No.84 above but S.S coupling 4 Nos
101 101 All as per Item No.84 above but Key for S.S coupling 4 Nos
102 102 All as per Item No.84 above but Stud and nut for connection piece 8 Nos
103 103 All as per Item No.84 above but Balancing of Rotar 6 Job
104 104 All as per Item No.84 above but T-Bolt with nut 20 Nos
105 105 All as per Item No.84 above but LNK Bolt S.S 20 Nos
106 106 All as per Item No.84 above but Submersible cable jointing 8 Nos
107 107 All as per Item No.84 above but CI Suction chamber 4 Nos
108 108 All as per Item No.84 above but CI stage bowl 12 Nos
109 109 All as per Item No.84 above but GM Impeller 12 Nos
110 110 All as per Item No.84 above but Guid Bush 12 Nos
111 111 All as per Item No.84 above but DOL Bush 6 Nos
112 112 All as per Item No.84 above but S.S DOL Sleeve 6 Nos
113 113 All as per Item No.84 above but Inter Ring 6 Nos
114 114 All as per Item No.84 above but CI DOL Piece 2 Nos
115 115 All as per Item No.84 above but CI NRV Body 2 Nos
116 116 All as per Item No.84 above but Impeller Key 12 Nos
117 117 All as per Item No.84 above but S.S Pump shaft single stage 8 Nos
118 118 All as per Item No.84 above but Remetling of G.M Impeller and turming 10 Nos
119 119 All as per Item No.84 above but Pump sand guard 4 Nos
120 120 All as per Item No.84 above but S.S Distance sleeve 12 Nos
121 121 All as per Item No.84 above but G.M Neck Ring 12 Nos
122 122 All as per Item No.84 above but M.S Stud with nut 40 Nos
123 123 All as per Item No.84 above but Coise mesh 4 Nos
124 124 All as per Item No.84 above but Drain Plug 10 Nos
125 125 Taking out submersible 15 HP/10HP/5 HP/3 HP Non-clog sewage pumpset from sewage well/STP pump duly disconnecting electric /sewage connections along with existing submersible cable , pipe etc and shifting pump set cable and pipe aside for reuse and lowering into sewage well after repair works including initial testing water proof cable jointing/sewage line connecting , final testing etc complete all as specified and as directed 6 Each Job
126 126 Taking out of horizontal submersible 40 HP/20 HP/ 15 HP/7.5 HP pump set from open well UG sump duly disconnecting electric /water connections , alongwith existing submersible cable pipe etc and shifting pump set cable and pipe aside for reuse and lowering into sewage well after repair works including initial testing water proof cable jointing water line connecting final testing etc complete all as specified all as directed by Engr-in-Charge.\nNote for item No 125 & 126 :- (i) The quoted rate deemed to be included the cost of rubber gaskets, nuts bolts, washers etc.\n(ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GE's decision shall be final and binding in this regard. 6 Each Job
127 127 Complete opening of 15 HP/ 10 HP capacity submersible non-clog sewage pump set for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed 1 Each Job
128 128 All as per Item No.127 above but 5 HP/3 HP 4 Each Job
129 129 Complete opening of horizontal submersible 40 HP / 20HP/ 15 HP/7.5 HP pump set for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed by Engr-in-Charge.\nNote :- (i) Cost of transportation of pump set from from site to workshop and back to site after repair is deemed to be included in the quoted rate. \n(ii) Repairs/replacement of parts/winding shall be measured and paid separetly. 6 Each Job
130 130 S & F in repairs impeller for 15 HP capacity Submersible non clog sewage pump set submersible Non-Clog sewage pump set all as provided by the original manufacturer complete all as specified and as directed 1 Each Job
131 131 All as per Item No.130 above but 10 HP Submersible non clog sewage pump set 2 Each Job
132 132 All as per Item No.130 above but 5 HP/3 HP Submersible non clog sewage pump set 4 Each Job
133 133 S & F in repairs impeller for 40 HP capacity Horizontal Submersible pump set horizontal submersible pump set all as provided by the original manufacturer complete all as specified and as directed by Engr-in-Charge. 2 Each Job
134 134 All as per Item No.133 above but 20 HP Horizontal Submersible pump set 1 Each Job
135 135 All as per Item No.133 above but 15 HP Horizontal Submersible pump set 1 Each Job
136 136 All as per Item No.133 above but 7.5 HP Horizontal Submersible pump set 1 Each Job
137 137 S & F in repairs ball bearing for 15 HP capacity Submersible non clog sewage pump set submersible Non-Clog sewage pump set all as provided by the original manufacturer complete all as specified and as directed 1 Each Job
138 138 All as per Item No.137 above but 10 HP Submersible non clog sewage pump set 2 Each Job
139 139 All as per Item No.137 above but 5 HP/ 3 HP Submersible non clog sewage pump set 3 Each Job
140 140 S & F in repairs ball bearing for 40 HP capacity Horizontal Submersible pump set horizontal submersible pump set all as provided by the original manufacturer complete all as specified and as directed by Engr-in-Charge. 3 Each Job
141 141 All as per Item No.140 above but 20 HP Horizontal Submersible pump set 1 Each Job
142 142 All as per Item No.140 above but 15 HP Horizontal Submersible pump set 1 Each Job
143 143 All as per Item No.140 above but 7.5 HP Horizontal Submersible pump set 1 Each Job
144 144 M & L in repairs for rewinding for 15 HP capacity Submersible non clog sewage pump set submersible non-clog sewage pump set motor by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size/turns, varnishing, assembling the motor complete testing at workshop complete all as specified and as directed 1 Each Job
145 145 All as per Item No.144 above but 10 HP Submersible non clog sewage pump set 4 Each Job
146 146 All as per Item No.144 above but 5 HP/ 3 HP Submersible non clog sewage pump set 4 Each Job
147 147 M & L in repairs for rewinding for 40 HP capacity Horizontal Submersible pump set horizontal submersible pump set motor by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size/turns, varnishing, assembling the motor complete testing at workshop complete all as specified and as directed 2 Each Job
148 148 All as per Item No.147 above but 20 HP Horizontal Submersible pump set 1 Each Job
149 149 All as per Item No.147 above but 15 HP Horizontal Submersible pump set 1 Each Job
150 150 All as per Item No.147 above but 7.5 HP Horizontal Submersible pump set 1 Each Job
151 151 S & F in repairs PVC insulated 3 core 10 Sqmm copper multistranded PVC sheathed submersible flexible cable ISI marked and conforming to IS : 694 and connecting to submersible pump and to LT panel after taking out old unserviceable cable complete all as specified and as directed. 300 RM
152 152 All as per Item No.151 above but 3 core 16 Sqmm 550 RM
153 153 S & F in repairs GI pipe light grade of 50 mm dia for cable protection complete all as specified and as directed. 48 RM
154 154 Supply, fix, jointing and testing of Cast iron Non Return valve 100 mm bore without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed\nNote:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. 8 Each
155 155 All as per Item No.154 above but 150 mm bore 2 Each
156 156 Supply and fix CI foot valve of size 100mm bore, flanged ends, swing type opration with rubber sheet, as per IS : 4038. Complete including taking out unserviceable foot valve all as specified and directed \nNote:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. 4 Each
157 157 All as per Item No.156 above but above but size 150 mm bore. 1 Each
158 158 All as per Item No.156 above but size 80 mm bore. 1 Each
159 159 All as per Item No.156 above but size 50 mm bore. 1 Each
160 160 S& F in repair MCCB 3 pole , 415 volts , fixed thermal and fixed magnetic setting 100 Amps with braking capacity 16 KA complete all as specified and as directed . \n 2 Each
161 161 All as per Item No.160 above but 160 Amps , with braking capacity 25 KA. 2 Each
162 162 All as per Item No.160 above but 250 Amps , with braking capacity 35 KA. 1 Each
163 163 S& F in repair MCCB 4 pole , 415 volts , fixed thermal and fixed magnetic setting 250 Amps with braking capacity 35 KA complete all as specified and as directed . 1 Each
164 164 S & F in repairs electronic timer for star-delta time delay 3 to 30 seconds all as per existing sample complete all as specified and as directed. 8 Each
165 165 S& F in repairs 3 pole power contactor type ML-1.5 , range 25 Amps , AC -3 complete all as specified and directed. 1 Each
166 166 All as per item No. 165 herein-before but type ML-2, 32 Amps 415Volts, 50 Hz. 1 Each
167 167 All as per item No 165 herein-before but type ML-3, 40 Amps 415Volts, 50 Hz. 1 Each
168 168 All as per item No 165 herein-before but type ML-4, 70 Amps 415Volts, 50 Hz. 2 Each
169 169 All as per item No 165 herein-before but type ML-6, 110 Amps 415Volts, 50 Hz. 4 Each
170 170 Supply and fix in replacement overload relay type MN-2 relay range 14-23 Amps complete all as specified and directed. 2 Each
171 171 All as per item No 170 here-in-before but type ML 2/3 Range 28-42 Amps . 2 Each
172 172 All as per item No 170 here-in-before but type ML 5 Range 45-75 Amps . 2 Each
173 173 All as per item No 170 here-in-before but type ML 5 Range 66-110 Amps . 4 Each
174 174 S&F in repairs DOL starter in sheet metal enclosure max motor output at 415 Volt, 3 phase, 5 HP, relay range 7-10 Amps complete all as specified and as directed.\n 2 Each
175 175 S&F in repairs star delta starter max motor output at 415 Volt, 3 phase, relay range 45-75 in sheet metal enclosure type ML-4 for 3 phase induction motor complete all as specified and as directed. 1 Each
176 176 S&F in repairs star delta starter max motor output at 415 Volt, 3 phase, relay range 28-42 in sheet metal enclosure type ML-3 for 3 phase induction motor complete all as specified and as directed. 1 Each
177 177 S&F in repairs star delta starter max motor output at 415 Volt, 3 phase relay range 20-32 in sheet metal enclosure type ML-2 for 3 phase induction motor complete all as specified and as directed. \n 1 Each
178 178 S&F in repairs star delta starter max motor output at 415 Volt, 3 phase relay range 9--14 Amps in sheet metal enclosure type MK-1 for 3 phase induction motor complete all as specified and as directed. 1 Each
179 179 S&F in repairs Single Phasing Preventer Relay type VSP-II, 415V complete all as specified and as directed. 4 Each
180 180 S&F in repair ammeter 415 volt, 3 phase 0 to 120 Amps rating, analogue type complete all as specified and as directed. 4 Each
181 181 S&F in repair voltmeter 415 volt,3 phase 0 to 500 volts rating, analogue type complete all as specified and as directed. 4 Each
182 182 Supply and fix of terminal strip 100 Amps 6 way complete all as specified and as directed. 2 Nos
183 183 Supply and fix of Digital Amp meter 96 x 96 Sqmm analogue type 0 to 100 amps complete all as specified and as directed. 2 Nos
184 184 Supply and fix in replacement of current transformer ratio 100/5 complete all as specified and as directed. 2 Nos
185 185 Supply and fix in replacement of current transformer ratio 60/5 complete all as specified and as directed 2 Nos
186 186 Supply and fix in replacement PVC insulated multristranded copper conductor wire 1100 volts, single core of size 10.00 Sqmm complete all as specified and as directed. 100 RM
187 187 All as per item No. 186 here-in-before but of size 16.00 Sqmm 100 RM
188 188 All as per item No 186 here-in-before but of size 25.00 Sqmm 150 RM
189 189 All as per item No 186 here-in-before but of size 35.00 Sqmm 200 RM
190 190 M&L for servicing of 30 KVA DG set Engine situated/ installed at site at different locations, including replacement of fuel filters, oil filters, air filters, air filter element, changing lubricating oil, cleaning of fuel lines, checking leakage if any, repair the leakage replacement of exhaust main fold gasket etc complete all as specified and as directed. \nNote:- (i) Lubrication oil shall be supplied free under Sch.'B'.\n(ii) Spare parts required for maintenance shall be measured and paid separately under relevant item. 1 Each
191 191 All as per item No 190 here-in-before but 125 KVA 1 Each
192 192 All as per item No 190 here-in-before but 160 KVA 1 Each
193 193 All as per Item No.190 here-in-before but 200/ 250 KVA 2 Each
194 194 All as per Item No. 190 but for Non -clog sewage Diesel Engine driven pump set 5 HP capacity 3 Each
195 195 Supply only diesel filter with gasket for 30 KVA capacity DG sets complete all as specified and as directed. 1 Each
196 196 All as per Item No.195 above but 125 KVA 1 Each
197 197 All as per Item No.195 above but 160 KVA 1 Each
198 198 All as per Item No.195 above but 200/ 250 KVA 2 Each
199 199 All as per Item No. 195 but for Non -clog sewage Diesel Engine driven pump set 5 HP 3 Each
200 200 Supply only engine oil filter with gasket for 30 KVA capacity DG sets complete all as specified and directed. 1 Each
201 201 All as per Item No.200 above but 125 KVA 1 Each
202 202 All as per Item No.200 above but 160 KVA 1 Each
203 203 All as per Item No.200 above but 200/ 250 KVA 2 Each
204 204 All as per Item No.200 above but for Non -clog sewage Diesel Engine driven pump set 5 HP 3 Each
205 205 Supply only high pressure fuel line with end coupler complete from FIP to injector complete all as specified and directed. 2 Each Job
206 206 Supply only flexible fuel pipe set all as per existing sample complete all as specified and directed. 2 Each Job
207 207 Supply only water hose pipes all as per existing sample complete all as specified and directed. 2 Each
208 208 Supply only Thermostat element all as per existing sample complete all as specified and directed. 2 Each
209 209 Replace the rubber coupling bush consist of rubber ring of suitable size and model (plate/ cup) with nuts bolts complete all as specified and directed. 2 Each Set
210 210 Supply only anti vibration pads of suitable size complete all as specified and directed. 2 Each
211 211 Supply and fill coolant of standard specification for top up in radiator of Diesel Engine of any size complete all as specified and directed. 50 Litre
212 212 S&F in repair Automatic Voltage Regulator (AVR) complete all as specified and as directed. \n 1 Each
213 213 S&F in repair stop solenoid switch complete all as specified and directed. 1 Each Set
214 214 S&F in repair copper terminal heavy duty for battery (length 1.5 mtr) connection with suitable size of copper lugs on one side brass lead on other end complete all as specified and as directed. 4 Each
215 215 M&L for complete removal and preparation of old painted surfaces of centrifugal pump set of 60 HP 3 phase capacity and applying two coats of synthetic enamel paint over a coat of red oxide primer complete and writing of MES/ SM No. complete all as specified and as directed 6 Each Job
216 216 All as per Item No.215 above but 40 HP 3 phase capacity 4 Each Job
217 217 All as per Item No.215 above but 15 HP 3 phase capacity 2 Each Job
218 218 All as per Item No.215 above but 10 HP 3 phase capacity 3 Each Job
219 219 M & L for providing gland packing as per existing size and make/model, of 60 HP 3 phase capacity C/F Motor Pump, complete all as specified and as directed 10 Each Job
220 220 All as per Item No.219 above but 40 HP 3 phase capacity 8 Each Job
221 221 All as per Item No.219 above but 15 HP 3 phase capacity 4 Each Job
222 222 All as per Item No.219 above but 10 HP 3 phase capacity 4 Each Job
223 223 Supply only greasing for bearing of centrifugal Pumps complete all as specified and as directed. \n 100 Kg
224 224 Clear site of from all rubbish, cut down shrubs, under growth and small trees not exceeding 600mm girth, grub up roots and burn or remove from site complete all as specified and as directed. 400 Sqm
225 225 Surface dressing of uneven surfaces of the natural ground, rough excavated surfaces and filled area where ordered shall be trimed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site, depth of cutting not exceeding 15 cm complete all as specified and as directed. 400 Sqm
226 226 S&F in repair off-load change over switch of rating 400 Amps, in sheet metal enclosure, 415V, AC, 50 Hz, side handle complete all as specified and as directed. 1 Each
227 227 All as per Item No.226 above but of capacity 250 Amps , 415 Volts, AC 50 Hz. 1 Each
228 228 All as per Item No.226 above but of capacity 200 Amps , 415 Volts, AC 50 Hz. 1 Each
229 229 All as per Item No.226 above but of capacity 100 Amps , 415 Volts, AC 50 Hz. 1 Each
230 230 Supply and fix in replacemenet of MS base channel for foundation as per existing size including cutting, welding, making hole, and paint (two coat of synthatic enamel paint over a coat of red oxide) complete all as specified and as directed. 300 Kg
231 231 Supply and fix of all type of MS foundation bolt with nut and washers of size 20 x 450 mm complete all as specified and as directed. 32 Nos
232 232 Supply and fix of Indicating light LED type R,Y,B complete all as specified and as directed. 12 Nos
233 233 Labour only for attending of Electric compliants of existing water supply Pump house panels /Borewells LT Panels/CF Motors/Subemrsible moters/Non-clog motors/Horizontal submesible , including connecting electrical accessories / spares of water supply installation, electrical fitting & short circuits in Pump house panel/CF Motors/Submersible motors/ Panels complete all as specified and as directed. \nNote :- (i) Any material required for attending complaints shall be measured & paid separately under respectvie item \n(ii) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician as applicable assisted with adequate No of helpers as directed by Enginner-in-charge.\n(iii) The rectifiable complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complaint. Time required to complete the defect shll be intimated to Engineer in chrge well in advance \n(iv) All machinery, T & P required for attending the complaints shall be arranged by the contracor on his own. \n(v) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site. 50 Each Job
234 234 Supply and fix clamps in MS flat 100 mm x 6 mm with two Nos of MS nut bolts for 100 mm dia column pipe complete all as specified and as directed. 6 Nos
235 235 Supply and fix in replacement of Pully V Belt SPB-1800 in STP Compressor (blower), twin lobe positive displacement type and pressure rating upto 0.8Kg/cm2 of exisitng make and model complete all as specified and as directed. 1 Nos
236 236 All as per Item No.235 above but Ball Bearing 6311/C3 Make-SKF/ZKL 2 Nos
237 237 All as per Item No.235 above but Roller bearing 3213A 2 Nos
238 238 All as per Item No.235 above but Piston ring 4 Nos
239 239 All as per Item No.235 above but Set of Gasket 4 Nos
240 240 All as per Item No.235 above but Gear set 1 Each set
241 241 All as per Item No.235 above but Oil seal 3 Nos
242 242 All as per Item No.235 above but Oil level glass 2 Nos
243 243 All as per Item No.235 above but Suction air filter 2 Each
244 244 All as per Item No.235 above but Air compressor shaft werlding , turning , grinding 2 Job
245 245 All as per Item No.235 above but Bearing tapper bush for roller bearing 22213 EK/C3 1 Each
246 246 All as per Item No.235 above but Outer distance bush 1 Nos
247 247 All as per Item No.235 above but Pressure ring 4 Nos
248 248 All as per Item No.235 above but Asbestos graphite packing(casing cover) 2 Nos
249 249 All as per Item No.235 above but Asbestos graphite packing(stuffing box) 2 Nos
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail