Electrification Of 32 Persons Hostel/Barrack And 1 No . Deliberation Room At Thana Barla District Aligarh, Aligarh-Uttar Pradesh

Public Works Department-PWD has published Electrification Of 32 Persons Hostel/Barrack And 1 No . Deliberation Room At Thana Barla District Aligarh. Submission Date for this Tender is 26-10-2020. Electrification Work Tenders in Aligarh Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25709430
Corrigendum : Electrification Of 32 Persons Hostel/Barrack And 1 No . Deliberation Room At Thana Barla District Aligarh
Open Tender
Indian
Uttar Pradesh
Aligarh
26-10-2020

Tender Details

Electrification Of 32 Persons Hostel/Barrack And 1 No . Deliberation Room At Thana Barla District Aligarh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Oct-2020 SUDDHI PATRA Date 26-10-2020

Key Value

Document Fees
INR 766 /-
EMD
INR 101000.0 /-
Tender Value
INR 10.08 Lakhs /-

BOQ Items

Name of Work: Electrification of 32 Persons Hostel/Barrack and 1 No. Deliberation room at Thana Barla District Aligarh
Sl. No. Item Description Item Code / Make Quantity Units
1 1 PART-A (HOSTEL/BARRACK)\n\nWiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete. and 1.5 sq. mm.PVC insulated core copper conductor cable as earthwire drawn inside the conduit.,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. 137 Nos.
2 2 Wiring point for two way light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete. and 1.5 sq. mm.PVC insulated core copper conductor cable as earthwire drawn inside the conduit.,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. 6 Nos.
3 3 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete. and 1.5 sq. mm.PVC insulated core copper conductor cable as earthwire drawn inside the conduit.,,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. 59 Nos.
4 4 Wiring point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete. and 1.5 sq. mm.PVC insulated core copper conductor cable as earthwire drawn inside the conduit., and piano type switch and socket etc., complete in all respect including matching colour wash. 62 Nos.
5 5 Wiring point for exhaust fan with 2.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete and 1.5 sq. mm.PVC insulated core copper conductor cable as earthwire drawn inside the conduit,GP Box , 15A piano type switch & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect including matching colour wash. 2 Nos.
6 6 Supply and wiring of submain 2.5 Sqmm with two number 20mm dia. heavy duty (2mm thick) PVC conduit with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit. 315 Mtr.
7 7 S/wiring of sub main with 2 no 4 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 20 mm dia heavy duty PVC conduit concealded in wall withone no 2.5 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cableas earth complete in all respect 335 Mtr.
8 8 S/wiring of sub main with 4 no 16 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 25 mm dia heavy duty PVC conduit concealded in wall withone no 6.0 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cableas earth complete in all respect 128 Mtr.
9 9 S/F of LED tube light with batten suitable for up to 1x22 watt. LED tube light complete includng tube etc on surface complete in all respect with 3year warranty 58 Nos.
10 10 Supply and fixing of 2' x 2' 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling Powder coated CRCA housing body diffuser of Special Polycarbonate meterial and driver set complete in all respect. 1 Nos.
11 11 S/F of LED Street Light Fitting having die cost Aluminium body and diffuser/Reflector with driver set suitable for 75 to 90 watt confirmong to I P 66 Degree of protection Complete in all respect with 3year warranty 4 Nos.
12 12 S/F of Power plug with 15A/250Volts flush type switch and 5 pin 15A/250Volts flush typeSocket complete 34 Nos.
13 13 S/O LED Bulb 15 Watt 82 Nos.
14 14 S/Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 volt grade at a depth of 750 mm below ground level/on surface the cable run shall be fixed on M S Clamp etc of following size
15 14.1 35 sq.mm x 3½ core cable 50 Mtr.
16 15 S/F Brass nikil plated comression glands as under
17 15.1 35 sq.mm x 3½ core cable 20 Nos.
18 16 S/F of plain or pin type copper tin plated cable socket (Lugs)
19 16.1 4 sq.mm 28 Nos.
20 16.2 16 sq.mm 62 Nos.
21 17 S/Burying of 600x600x6mm GI plate 3 mtr below ground level with 20 mm dia G I pipe for watering etc complete in all respect 2 Nos.
22 18 Supply and laying of 25mm x 3mm GI strip from earth electrode directly in the ground as required complete in all respect. 27 Mtr.
23 19 Supply & Errection of factory fabricated & wired metal clad dust and vermin proof floor mounting M.S. channel base with bottom and top cable entries electrical control pannel with TPN Fuse complete 100 Amp TPN 01 Nos Incoming and outgoing 32 Amp TPN 03 Nos 1 Nos.
24 20 S & F surface/Flush mounting 4ways V TPN distribution board with additional Door without DPX3 160 MCCB complete in all respect, as directed at site by Engineer in charge. 8 Nos.
25 21 S/F of 100 Amp four pole change over switch on 40 mm x 40mmx6mm angle iron frame including cost of labour T&P 1 Nos.
26 22 S&F of 100 Amp 4 pole MCCB (25 KA) Thermal Magnetic release 8 Nos.
27 23 S/F 6 Amp to 32 Amp SPMCB (10 KA) 52 Nos.
28 24 S/F of Rubber matting1800x900x12 mm tested and chequred 1 Nos.
29 25 S/F of shock Treatmemt Chart (prescribed under IE rules) 1 Nos.
30 26 Erection and testing of ceiling fan and regulator etc Excluding S/o down rod complete in all respect. 43 Nos.
31 27 S/F hexagonal G.P fan box of approved make 43 Nos.
32 28 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 4 Nos.
33 29 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 1 Nos.
34 30 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 4 Nos.
35 31 S/F of Electronic fan regulator 120-280 Volts ISI Marked 43 Nos.
36 32 S/F of Ceiling Fan 1200mm 43 Nos.
37 33 S/F of Fresh Air Fan 300mm 16 Nos.
38 34 S/F of Exhaust fan 300mm 2 Nos.
39 35 PART-B (VIVECHNA ROOM)\n\nWiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete. and 1.5 sq. mm.PVC insulated core copper conductor cable as earthwire drawn inside the conduit.,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. 22 Nos.
40 36 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete. and 1.5 sq. mm.PVC insulated core copper conductor cable as earthwire drawn inside the conduit.,,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. 8 Nos.
41 37 Wiring point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete. and 1.5 sq. mm.PVC insulated core copper conductor cable as earthwire drawn inside the conduit., and piano type switch and socket etc., complete in all respect including matching colour wash. 16 Nos.
42 38 Supply and wiring of submain 2.5 Sqmm with two number 20mm dia. heavy duty (2mm thick) PVC conduit with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit. 55 Mtr.
43 39 S/wiring of sub main with 2 no 4 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 20 mm dia heavy duty PVC conduit concealded in wall withone no 2.5 sq.mm FR PVC insulated 1100 Volt Grade multi strand single core copper conductor cableas earth complete in all respect 28 Mtr.
44 40 S/F Surface/Flush mounting 12way SPN Distribution board witout MCB with additional metel door complete in all respect 1 Nos.
45 41 S/F of LED tube light with batten suitable for up to 1x22 watt. LED tube light complete includng tube etc on surface complete in all respect 8 Nos.
46 42 S/F of LED Street Light Fitting having die cost Aluminium body and diffuser/Reflector with driver set suitable for 85 to 90 watt confirmong to I P 66 Degree of protection Complete in all respect 4 Nos.
47 43 S/F of10 Watt LED bulkhead fitting wth driver set confirmong to I P 65 Degree of protection Complete in all respect 4 Nos.
48 44 S/F of Power plug with 15A/250Volts flush type switch and 5 pin 15A/250Volts flush typeSocket complete 4 Nos.
49 45 S/O LED Bulb 15 Watt 6 Nos.
50 46 S/Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 volt grade at a depth of 750 mm below ground level/on surface the cable run shall be fixed on M S Clampetc of following size
51 46.1 10 sq.mm x 2 core cable 30 Mtr.
52 47 S/F Brass nikil plated comression glands as under
53 47.1 10 sq.mm x 2 core cable 10 Nos.
54 48 S/F of plain or pin type copper tin plated cable socket (Lugs)
55 48.1 4 sq.mm 25 Nos.
56 48.2 10 sq.mm 6 Nos.
57 49 S/Burying of 600x600x6 mm G I earth plate 3 mtr below ground level with 20 mm dia G I pipe for watring etc complete in all respect 1 Nos.
58 50 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. 10 Mtr.
59 51 S/F 6 Amp to 32 Amp DPMCB (10 KA) 1 Nos.
60 52 S/F 6 Amp to 32 Amp SPMCB (10 KA) 8 Nos.
61 53 S&F of 16 Amp. 240V metal clad DP rewireable type switch fuse unit complete on MDFEG/Teak wood board complete 1 Nos.
62 54 S/F of shock Treatmemt Chart (prescribed under IE rules) 1 Nos.
63 55 Erection and testing of ceiling fan and regulator etc Excluding S/o down rod 6 Nos.
64 56 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 1 Nos.
65 57 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 2 Nos.
66 58 S/F of Electronic fan regulator 120-280 Volts ISI Marked 6 Nos.
67 59 S/F of Ceiling Fan 1200mm 6 Nos.
68 60 S/F of Fresh Air Fan 300mm 2 Nos.
69 61 S/F hexagonal G.P fan box of approved make 6 Nos.
Disclaimer :