Military Engineer Services-MES has published Repair Replacement Of Internal Wiring Of Md Accn , Repair Of Geyser , Ceiling Fan , Exhaust Fan And Repair To Solar Water Heater And Other Misc Repair Work At Mil Stn Bikaner. Submission Date for this Tender is 02-11-2020. Electrification Work Tenders in GE (N) Bikaner Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: Repair/Replacement of internal wiring of Md Accn, repair of Geyser, ceiling fan, exhaust fan & repair to solar water heater and other Misc repair work at Mil Stn Bikaner. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down carefully existing unserviceable Copper/aluminum batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engr-in-Charge. | 1055 | Per Point | |
2 | 2 | Taking down of unserviceable DBs/switch fuses/changeover in sheet steel enclosure complete with MCBs/Fuse/grips any capacity and removing from site and making good disturbed surface of wall, floor etc. Taking after disconnecting all cable complete all as specified and as directed by the Engr-in-Charge. | 5 | Each | |
3 | 3 | M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including surface PVC conduit Medium class 20mm dia ISI marked with all fittings such as tees, bends etc terminating in and including sunken box covered with and including 3 mm thick bakelite laminated sheet top cover ‘Hylam’ for one fan or light or 5Amps socket or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.Make of cables :Havell's/Paragon/Nicco/L&T.Make of PVC Conduit : Polycab/Supreme/Modi/Finolex/Prince/Precision | 330 | Per Point | |
4 | 4 | M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including PVC caping casing Medium class 20mm dia ISI marked with all fittings such as tees, bends etc terminating in and including sunken box covered with and including 3 mm thick bakelite laminated sheet top cover ‘Hylam’ for one fan or light or 5Amps socket or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.Make of cables :Havell's/Paragon/Nicco/L&T.Make of PVC casing capping : Polycab/Supreme/Modi/Finolex/Prince/Precision | 330 | Per Point | |
5 | 5 | All as per item No 3 here-in-before but socket point on the independent board with other switches complete as specifed as directed by Engineer - In - Charge | 180 | Per Point | |
6 | 6 | All as per item No 3 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge | 140 | Per Point | |
7 | 7 | All as per item No 3 here-in-before but cable of 2.5 Sq mm for 15 Amp switch socket outlet on independent board including provision of 2.5 Sqmm PVC insulated unshethed multistranded copper conductor as earth wire | 130 | Per Point | |
8 | 8 | All as per item No 3 here-in-before but for one light point control by two way switch complete all as specified and as directed by Engineer-in-Charge. | 15 | Per Point | |
9 | 9 | M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including surface in existing PVC conduit Medium class 20mm dia ISI marked with all fittings such as tees, bends etc terminating in and including sunken box covered with and including 3 mm thick bakelite laminated sheet top cover ‘Hylam’ for one fan or light or 5Amps socket or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.Make of cables :Havell's/Paragon/Nicco/L&T.Make of PVC Conduit : Polycab/Supreme/Modi/Finolex/Prince/Precision | 180 | Per Point | |
10 | 10 | All as per item No 8 here-in-before but in existing conduit cable of 2.5 Sq mm for 15 Amp switch socket outlet on independent board | 70 | Per Point | |
11 | 11 | Supply & fixing LED T8 Tube light rod ( Retro Fit ) ingress protection IP20 18W in make CG/Havells/Phillips/polycab with complete all as specified and directed by engineer-in-charge. | 70 | Each | |
12 | 12 | Supply & fixing Connecting fixture for T8 tube light 1*18w/20w 4 Ft in make CG / Havells/Phillips/ploycab. complete all as specified and directed by engineer-in-charge. | 70 | Each | |
13 | 13 | S&F in replacement LED T5 Batten lightening fixture, energy efficent 18/20 Watt ( 4 feet) complete all as specified and directed by engineer-in-charge make:-CG/ Havells/Phillips | 675 | Each | |
14 | 14 | S&F in replacement Decorative ultra slim linear LED T5 Batten lightening fixture, Eco friendly energy efficent 10/12Watt (2 Feet) complete all as specified and directed by engineer-in-charge make :-Havells/Phillips/CG | 150 | Each | |
15 | 15 | Supply & fix in replacement LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished complete all as specified and directed by Engineer-in-charge. Make:-CG / havell's / Phillips. | 40 | Each | |
16 | 16 | S&F in replacement lamp holder PVC/Poly carbonate body with back plate with LED Bulb complete all as specified and as directed by Engineer-in-Charge.Make - Havells. Cona, SSK, wipro, Legrand | 190 | Each | |
17 | 17 | S&F in replacement Switch piano Single pole 5 Amps, two way, complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 70 | Each | |
18 | 18 | S&F in replacement switch piano flush type, Single pole 5 Amps, one way, complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 1600 | Each | |
19 | 19 | S&F in replacement of switch piano flush type, Single pole 15 Amps, one way, complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 150 | Each | |
20 | 20 | S&F in replacement of socket outlet flush type, 3/5 pin, 5/15 Amps, complete all as specified and as directed by Engineer-in-Charge. Make - Havells. Cona, SSK, wipro, Legrand | 150 | Each | |
21 | 21 | S&F in replacement of socket outlet flush type, 3 pin, 5 Amps, complete all as specified and as directed by Engineer-in-Charge. Make - Havells. Cona, SSK, wipro, Legrand | 150 | Each | |
22 | 22 | S&F in replacement of ceiling fan regulator electronic type, 230 Volt, 150 Watt with 5 step of control including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed by Engineer-in-Charge. | 90 | Each | |
23 | 23 | S&F in replacement of ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge | 200 | Each | |
24 | 24 | S&F in replacment PLS Lamp two pin 9W Make :Crompton Greaves/Philips/Wipro | 40 | Each | |
25 | 25 | S&F in replacement Recessed mounting LED 2x2 luminaire type BCTBLR 36W ZTN NW in make Bajaj or equivelent in CG / Phillips / GE / Wipro / Havell's | 15 | Each | |
26 | 26 | Supply and Fixing in replacement MCB single pole, 240 volts of rating 6-32 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make :- Legrand,ABB,Schneider | 150 | Each | |
27 | 27 | Supply and Fixing in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply C Curve single pole and neutral(SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- ABB,Legrand,Schneider | 80 | Each | |
28 | 28 | Supply and Fixing in replacement MCB 63 Amps, 440 Volt AC supply Triple pole with neutral(TPN) C curve with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ABB/Schneider | 10 | Each | |
29 | 29 | S&F blank cover for MCB DBs | 20 | Each | |
30 | 30 | S&F in replacement Bell Ding dong AC single pole 230volts Make : Havells,Cona,SSK,wipro, Legrand | 100 | Each | |
31 | 31 | S&F in replacement Bell push button Piano flush type single pole 5Amps make : Havells,Cona,SSK,wipro, Legrand | 100 | Each | |
32 | 32 | S&F in replacement sub main wiring in PVC casing and capping with 2 single core 10 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 10 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC Cassing and Capping all as specified and as directed by Engineer-in-Charge.(Note two run of 10 sqmm and one run of 10 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells | 70 | RM | |
33 | 33 | All as per item No 32 above but of size 6 sqmm and earth wire of 6 sqmm | 80 | RM | |
34 | 34 | All as per item No 32 above but of size 4 sqmm and earth wire of 4 sqmm | 80 | RM | |
35 | 35 | All as per item No 32 above but in existing conduit with cable of size 10 sqmm and earth wire of 10 sqmm | 80 | RM | |
36 | 36 | All as per item No 32 above but in existing conduit with cable of size 6 sqmm and earth wire of 6 sqmm | 105 | RM | |
37 | 37 | All as per item No 32 above but in existing conduit with cable of size 4 sqmm and earth wire of 4 sqmm | 110 | RM | |
38 | 38 | S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 8 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate | 15 | Each | |
39 | 39 | Ditto item -38 but for 4 way SPN | 5 | Each | |
40 | 40 | S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,TPN 4 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate | 5 | Each | |
41 | 41 | S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 230 volts with 200 Amps rated bus bar, load line DB's are fittied with bus bar nutural links blank plates TPN vertical load line 4 ways suitable for TP/FP 'A' frame MCCB,includeing 100 Amps MCCB -01Nos ,MCB SPN 32 -04 Nos and MCB SP 04 Nos, complete all as specified and as directed by Engineer-in-Charge. Make - Havells or equivelent Legrand/ GE/Seimens/L&T/Schneider/Indo Asian/C & S/ABB/BCH/HPL Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate | 2 | Each | |
42 | 42 | S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 20Amps capacity complete all as specified and directed by Engr-in-charge Cat Part No 607841 in Make Legrand or equivalent in schneider/Seimens/L&T | 40 | Each | |
43 | 43 | S & F in replacement LED Bulb 0.5W as approval by G.E (in different colors) complete all as specified and as directed by engr-in-charge Make : Havell's/CG/Phillips. | 100 | Each | |
44 | 44 | S&F in replacement bad side fitting with suitable LED bulb complete all as specified and directed by Engr-in-charge. Sample approved by Engr-in-charge and GE . | 20 | Each | |
45 | 45 | S&F in replacement Decorative wall / surface light fixture made up of Polycarbonate, suitable for retrofit 9/11 W LED lamp Complete all as specified and directed by Engr-in-charge. Sample as approved by Engr-in-charge | 50 | Each | |
46 | 46 | S&F in replacement Modular switch 1 way 6A, 1 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 140 | Each | |
47 | 47 | S&F in replacement Modular switch 1 way 16A, 1 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 40 | Each | |
48 | 48 | S&F in replacement Socket, 6A - 2/3 pin combined 2 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 140 | Each | |
49 | 49 | S&F in replacement Socket, 16A - 2/3 pin combined 2 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 40 | Each | |
50 | 50 | S&F in replacement Fan step regulator, 120W - 2 module complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 25 | Each | |
51 | 51 | S&F in replacement White cover plate with frame, 1 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 10 | Each | |
52 | 52 | S&F in replacement White cover plate with frame, 2 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 10 | Each | |
53 | 53 | S&F in replacement White cover plate with frame, 3 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 10 | Each | |
54 | 54 | S&F in replacement White cover plate with frame, 4 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 10 | Each | |
55 | 55 | S&F in replacement White cover plate with frame, 6 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 10 | Each | |
56 | 56 | S&F in replacement White cover plate with frame, 8 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand | 10 | Each | |
57 | 57 | REPAIR TO FAN :- \n Taking down ceiling fan for repair/serviceing (i.e. winding/ greasing/oiling etc.), 1200/1400 mm sweep of any make and any type model, sealing cable end with tape, dismantling the blades , removing fan and deposite the blades/motor to store for repairing/serviceing complete all as specefied and as directed by Engineer in charge. | 1200 | Each Job | |
58 | 58 | Hanging only ceiling fan and connection up the point including provision of cable from ceiling rose to fan complete all as specefied and as directed by Engineer in charge. (Note: For the purpose of payment, the wire using ceiling rose to fan for connection shall be measured and paid seperate in appropriate item and nothing extra pay for this item) | 1200 | Each Job | |
59 | 59 | Re-winding of ceiling fan of size 1200 mm sweep with super enameled copper winding wire of gauge as per existing size /No. of turns confirming to IS, including varnishing the motor windings with best quality varnish complete all as specefied and as directed by Engineer in charge. (Make:Milan/Atlas/Chetak) | 1050 | Each | |
60 | 60 | Ditto all as per item No 48. here in above but new model ceiling fan of size 1400 mm sweep complete all as specefied and as directed by Engineer in charge. | 150 | Each | |
61 | 61 | S&F in replacement of ball bearing of size/No. 6201 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NBC/SKF) | 250 | Each | |
62 | 62 | S&F in replacement of ball bearing of size/No. 6202 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NBC/SKF) | 250 | Each | |
63 | 63 | S&F in replacement of ball bearing of size/No. 6203 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NBC/SKF) | 250 | Each | |
64 | 64 | S&F in replacement of brass bush suitable for ceiling fan of any make and model confirming to IS complete all as specefied and as directed by Engineer in charge. | 500 | Each | |
65 | 65 | S&F in replacement of broken bottom cover (bowl) of PVC suitable for ceiling fan of any make and model as per existing size and shape complete all as specefied and as directed by Engineer in charge. | 20 | Each | |
66 | 66 | S&F in replacement of shaft for ceiling fan as per existing size and shape complete all as specefied and as directed by Engineer in charge. | 90 | Each | |
67 | 67 | S&F in replacement down rod made out of 15mm dia MS Pipe medium Duty 60 cm long duly painted including nut, bolt & washer etc and including drilling holles on top and bottom fan fixing with fan hooks and ceiling fan respectively as reuired suitable for 1200/1400mm sweep of ceiling fan complete all as specified and directed by Engineer-in-charge . | 150 | Each | |
68 | 68 | S&F in replacement D Clamp with nuts, bolts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed by Engineer in charge. | 500 | Each | |
69 | 69 | S&F PVC Canopies (Set of two) as required at site and complete all as specefied and as directed by Engineer in charge | 25 | Each | |
70 | 70 | S&F condenser 2.5 MFD confirming to IS complete all as specefied and as directed by Engineer in charge. | 1200 | Each | |
71 | 71 | S&F of flexible wire of size 23/0.0076 stranded copper conductor complete all as specefied and as directed by Engineer in charge. | 430 | RM | |
72 | 72 | M & L in replacement fan blade (set of three) set suitable for 1200mm sweep ceiling fan of any make complete all as specefied and as directed by Engineer in charge. | 10 | Set(Set of 3) | |
73 | 73 | M & L in replacement fan blade(set of three) set suitable for 1400mm sweep ceiling fan of any make complete all as specefied and as directed by Engineer in charge. | 10 | Set(Set of 3) | |
74 | 74 | Cleaning and preparation of old surface of the ceiling fan complete of size 1200/1400mm sweep and spray coat painting with synthetic enameled paint complete all as specified as directed by Engineer-in-Charge. | 300 | Each Job | |
75 | 75 | REPAIR TO EXHAUST FAN \nTaking down and dismantling of exhaust fan 225mm/300mm/375mm/450mm sweep of any make and model, opening the cover, separating the rotor and stator assembly, locating the fault and making the fan fully serviceable condition including replacing the defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same and testing complete to the satisfaction of Engineer in charge. | 160 | Each Job | |
76 | 76 | Fixing only Exhaust fan and connection up the point including cable from ceiling rose to fan complete all as specefied and as directed by Engineer in charge. | 160 | Each | |
77 | 77 | Re-winding of exhaust fan 225mm sweep with super enameled copper winding wire as per existing size confirming to IS including varnishing the motor windings with best quality varnish complete all as specefied and as directed by Engineer in charge. (Make:Milan/Atlas/Chetak) | 30 | Each Job | |
78 | 78 | Ditto all as per item No 77 here in above but of size 300mm sweep complete all as specefied and as directed by Engineer in charge. | 30 | Each Job | |
79 | 79 | Ditto all as per item No 77 here in above but of size 375mm sweep complete all as specefied and as directed by Engineer in charge. | 50 | Each Job | |
80 | 80 | Ditto all as per item No 77 here in above but of size 450mm sweep complete all as specefied and as directed by Engineer in charge. | 50 | Each Job | |
81 | 81 | S&F in replacement of blades for size of exhaust fan 225mm dully approved by GE complete all as specefied and as directed by Engineer in charge. | 10 | Each | |
82 | 82 | Ditto all as per item No 81 here in above but size of exhuast fan 300mm sweep complete all as specefied and as directed by Engineer in charge. | 10 | Each | |
83 | 83 | Ditto all as per item No 81 here in above but size of exhuast fan 375mm sweep complete all as specefied and as directed by Engineer in charge. | 10 | Each | |
84 | 84 | Ditto all as per item No 81 here in above but size of exhuast fan 450mm sweep complete all as specefied and as directed by Engineer in charge. | 10 | Each | |
85 | 85 | S & F in replacement of condenser 04 MFD confirming to IS complete all as specefied and as directed by Engineer in charge. | 150 | Each | |
86 | 86 | S & F in replacement of MS shaft for exhaust fan as per existing size and shape complete all as specefied and as directed by Engineer in charge. | 10 | Each | |
87 | 87 | S&F in replacement of MS back side cover for Exhaust fan of any sweep, size and make complete all as specefied and as directed by Engineer in charge. | 10 | Each | |
88 | 88 | S&F in replacement exhuast fan louver shutters of size( 225/300/375/450 mm ) and make complete all as specified and as directed by engineer-in-charge. | 10 | Each | |
89 | 89 | Cleaning and preparation of old surface of the Exhuast fan complete of size ( 225/300/375/450mm) and Spray painting with synthetic enameled paint complete all as specified as directed by Engineer-in-Charge. Make of paint : Asian/berger/nerolac. | 30 | Each Job | |
90 | 90 | REPAIR TO GEYSER \nTaking down and opening of the geysers 25/35/50 ltrs capacity any make complete for inspection descaling by chemical treatment of internal parts such as steel inner tank, siphon assembly, heating element, etc re-assembling and refixing the same to its original position after testing on pressure complete all as directed by the Engineer-in-charge. Note :- Items such as glass wool, steel inner tank, siphon assembly etc if found unserviceable under above item will be measured and paid for separately under its relevant item. | 2000 | Each Job | |
91 | 91 | Supply and fixing in replacement steel inner tank for capacity of geyser 25 ltrs as per existing size and shape. | 200 | Each | |
92 | 92 | Supply and fixing in replacement glass lined inner tank for capacity of geyser 25 ltrs as per existing size and shape. Make : Bajaj/Marc or equivalent | 20 | Each | |
93 | 93 | Supply and fixing in replacement siphon assembly suitable for 25 ltrs Geysers, with rubber washer of suitable size.Make : Marc/Bajaj/Polar or equivalent | 400 | Each | |
94 | 94 | Supply and fixing in replacement glass wool insulation material | 30 | Kg | |
95 | 95 | S&F in repair hot water pipe 15 mm bore 60 cm long with brass unions one(Chromium plated) one on each side. Pipe shall be as per I.S for 15 mm bore of pipe for 25/35/ 50 ltrs capacity Geysers. | 300 | Each | |
96 | 96 | Supply and fixing in replacement steel inner tank for capacity of geyser 35/50 ltrs as per existing size and shape. | 75 | Each | |
97 | 97 | Supply and fixing in replacement siphon assembly suitable for 35/50 ltrs Geysers, with rubber washer of suitable size. | 50 | Each | |
98 | 98 | S&F in repair Thermostat switch I.S.I marked, to Geysers 25/35/50 ltrs of any make / size and shape as per site requirement | 800 | Each | |
99 | 99 | S&F Low density polythene pipe (LDPE) connection arrangement with pipe of pressure rating 2.5 kgf/cm2 , 15 mm bore 30 cm to 45 cm long with brass unions one(Chromium plated) one on each side in repair to Geysers 25/50 ltrs. Pipe shall be as per I.S.I | 250 | Each | |
100 | 100 | Supply and fix in replacement heating element of rating 1.5 KW capacity including washers for 25/35 ltrs capacity Geysers.Make :- “Marc/THETA/ ALERT” | 1800 | Each | |
101 | 101 | Supply and fix in replacement heating element of rating 2.0 KW capacity including washers for 50 ltrs capacity Geysers.Make :- “Marc/THETA/ ALERT” | 350 | Each | |
102 | 102 | Supply and fix in replacement Indicator lamps as per existing type having red or green coloured reflector all as specified and directed by Engineer-in-Charge | 100 | Each | |
103 | 103 | Supply and fixing in replacement flexible, 3 core PVC insulated copper conductor cable of size 40/0.0076 with over all PVC insulation ISI marked Make “ PARAGON/ PLAZA/ INCAB/ FINOLEX” | 200 | RM | |
104 | 104 | Supply and fixing in replacement plug top, 3 pin 15 Amps, including making necessary connections Make :- ANCHOR/ LEADER/ legrand / HAVELLS”, ISI marked. | 100 | Each | |
105 | 105 | Supply and fixing in replacement pressure release valve suitable for 15 mm bore of pipe for 25/ 35/50 ltrs capacity Geysers. | 40 | Each | |
106 | 106 | Supply & fixing in replacement bib cock cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified Make :- GMP/NETA/JINDAL for 15 mm bore pipe ) | 40 | Each | |
107 | 107 | Supply and fixing in replacement stop cock cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified.Make :- GMP/ NETA/ JINDAL for 15 mm bore pipe. | 40 | Each | |
108 | 108 | Lagging to pipes used in hot water supply or plumbing all around with 25mm thick, bounded mineral wool performed 'SNAP ON' pipe sections of density 144 Kg/Cum confirming to IS 9842 on outer side of hot water pipe line of 20mm bore including bend with 0.1 mm aluminium foil complete all as specified and directed. | 40 | RM | |
109 | 109 | Lagging to pipes used in hot water supply or plumbing all around with 25mm thick, bounded mineral wool performed 'SNAP ON' pipe sections of density 144 Kg/Cum confirming to IS 9842 on outer side of hot water pipe line of 15mm bore including bend with 0.1 mm aluminium complete all as specified and directed. | 45 | RM | |
110 | 110 | Lagging to pipes used in hot water supply or plumbing all around with 25mm thick, bounded mineral wool performed 'SNAP ON' pipe sections of density 144 Kg/Cum confirming to IS 9842 on outer side of hot water pipe line of 25mm bore including bend with 0.1 mm aluminium complete all as specified and directed. | 40 | RM | |
111 | 111 | Supply & filling distilled water inside solar water storage tank as heat exchanger agent and solar water battery complete all as specified and directed | 90 | Ltr | |
112 | 112 | S & F in replacement borosilicate glass tube for solar water heater 3.3 with high impact resistance to hail strom evacuated tube of length 1500mm, out tube dia 47mm, inner tube dia 37mm and glass thickness 1.6 ± 0.15 and weight 1.3 Kg single tube complete all as specified and directed. | 80 | Each | |
113 | 113 | Removing of broken / cracked unserviceable solar flat plate collector cover plate made of toughened glass,including supply and fixing new solar flat plate collector cover plate made of toughened glass of size 3.2mm to 4.06 mm thick of suitable make for existing solar water heating system of capacity any capacity as per site requiment and sample approved by Enginer q-in-charge and GE also | 25 | Each | |
114 | 114 | S&F Tubes in replacement, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors of pipe 15mm bore. | 90 | RM | |
115 | 115 | All as per item No 113 but 20mm bore pipe | 90 | RM | |
116 | 116 | All as per item No 113 but 25mm bore pipe | 90 | RM | |
117 | 117 | S&F in replacement stop valve, cast copper alloy, screwed down high pressure with crutch or butter fly handle screwed both ends for 20mm bore GI pipe or for unions complete all as specified and directed by EIC. | 40 | Each | |
118 | 118 | All as per item no. 105 but in size 25mm. | 25 | Each | |
119 | 119 | S&F in replacement Rotational moulded polyethylene water storage tanks of 1000 Litres capacity triple layers ISI marked , (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed by Engr-in-Charge. | 1 | Each | |
120 | 120 | All as per item No. 118 here in before but 500 litre capacity. | 1 | Each | |
121 | 121 | S&F in replacement Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) complete all as specified and as directed by EIC. Make : PRAYAG/ POLYTUF / SHAKTI. | 50 | Each | |
122 | 122 | M & L in replacement heating element of rating 3.0 KW suitable for solar water heater make : Theta/Alert. | 10 | Each | |
123 | 123 | S & F in replacement metal clad two pin and earth plug top make : legrand/indo asian/ L&T / standard | 40 | Each | |
124 | 124 | Dismantling and cleaning of solar panel by removing all the bird disposal, dust and other migrated disposal deposited on panel both inside and outside with suitable detergent including renewal of all the nut bolts, screw, union complete all as per specified and directed | 25 | Each | |
125 | 125 | Removing of unserviceable stainless steel insulated hot water storage tank and supply and fixing new stainless steel insulated hot water storage tank duly fitted with heat exchanger suitable make and size for existing solar heater system of capacity 500 LPD. | 2 | Each | |
126 | 126 | Removing of unserviceable stainless steel insulated hot water storage tank and supply and fixing new stainless steel insulated hot water storage tank duly fitted with heat exchanger suitable make and size for existing solar heater system of capacity 300 LPD. | 2 | Each | |
127 | 127 | Removing of unserviceable stainless steel insulated hot water storage tank and supply and fixing new stainless steel insulated hot water storage tank duly fitted with heat exchanger suitable make and size for existing solar heater system of capacity 200 LPD. | 2 | Each | |
128 | 128 | Removing of unserviceable stainless steel insulated hot water storage tank and supply and fixing new stainless steel insulated hot water storage tank duly fitted with heat exchanger suitable make and size for existing solar heater system of capacity 100 LPD. | 2 | Each | |
129 | 129 | S & F in repair bib tap PVC high density of 15mm dia complete all as specified and directed. | 10 | Each | |
130 | 130 | Replacement of PVC hose connection heavy duty 20mm dia both ended fitted with union and check nut complete all as specified and directed | 30 | Each |