Madhyanchal Vidut Vitran Nigam Limited has published Running Contract Of Carriage Of Pcc/Stp Poles , Abc Cable 3X50/3X95/11Kv Transformers 10/16/25/63/100 Kva Etc Material From Store Byebagh To Various Work Sites And Erection , Earthing In Full Deposite Head Under Edd-Tilhar Under Edc Shahjahanpur. Submission Date for this Tender is 27-10-2020. Electrification Work Tenders in SHAHJAHANPUR Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 14-Oct-2020 | CORR1410 | Date | 20-10-2020 |
2 | 20-Oct-2020 | CORR2010 | Date | 27-10-2020 |
Name of Work: RUNNING CONTRACT FOR EXECUTION OF VARIOUS WORK OF CARRIAGE OF PCC/STP POLES, ABC CABLE 3*50/3*95/11KV , TRANSFORMERS 10/16/25/63/100 KVA ETC MATERIAL FROM STORE BYEBAGH TO VARIOUS WORK SITES AND ERECTION, EARTHING IN FULL DEPOSITE HEAD UNDER EDD-TILHAR UNDER EDC SHAHJAHANPUR (MVVNL) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | The work of safe carriage of the following material from Byebagh store center to work site under the jurisdiction of EDD-TILHAR,Shahjahanpur. Approx. distance upto 80 Km. Including safe loading and unloading. | |||
2 | 1.1 | PCC Pole 8.5 meter long. | 150 | Nos. | |
3 | 1.2 | STP 11 Mtr Long | 20 | Nos. | |
4 | 1.3 | Line material i.e., cross arm/ conductor/ pin insulater/stay/earthing rod/Disc Fitting/Disc Insulators/11 KV XLPE Cable etc | 100 | Qtl | |
5 | 1.4 | 11/0.4 KV 1 Phase 10/16 KVA T/F | 6 | Nos. | |
6 | 1.5 | 11/0.4 KV 3 Phase 25 KVA T/F | 18 | Nos. | |
7 | 1.6 | 11/0.4 KV 3 Phase 63 KVA T/F | 11 | Nos. | |
8 | 1.7 | 11/0.4 KV 3 Phase 100 KVA T/F | 4 | Nos. | |
9 | 1.8 | 11 KV Pilfer proof Metering cubical and CT PT Unit | 1 | Nos. | |
10 | 2 | Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms | |||
11 | 2.1 | PCC Pole 8.5 Mtr Long Single Pole | 130 | Nos. | |
12 | 2.2 | PCC Pole 8.5 Mtr Long Double Pole | 10 | Nos. | |
13 | 2.3 | ST Pole 11 Mtr Long Single Pole. | 10 | Nos. | |
14 | 2.4 | ST Pole 11 Mtr Long Double Pole. | 5 | Nos. | |
15 | 3 | Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms | |||
16 | 3.1 | PCC Pole 8.5 Mtr Long Single Pole | 100 | Nos. | |
17 | 3.2 | PCC Pole 8.5 Mtr Long Double Pole | 50 | Nos. | |
18 | 3.3 | ST Pole 11 Mtr Long Single Pole. | 10 | Nos. | |
19 | 3.4 | ST Pole 11 Mtr Long Double Pole. | 5 | Nos. | |
20 | 3.5 | The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms | 50 | Nos. | |
21 | 4 | Laying, Stringing & Sagging of Following Conductor complete in all respect | |||
22 | 4.1 | ACSR Weasal Conductor | 5 | Km. | |
23 | 4.2 | ACSR Dog Conductor | 0.5 | Km. | |
24 | 4.3 | 3 Phase Arial Bunched Conductor | 1 | Km. | |
25 | 4.4 | 1 Phase Arial Bunched Conductor | 0.5 | Km. | |
26 | 4.5 | Mounting of CT PT unit on double pole | 1 | Job | |
27 | 5 | Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides. Alongwith filling of 04 nos cable jointing kits | |||
28 | 5.1 | 11 KV XLPE Cable Size 3x70 sqmm | 20 | Mtr | |
29 | 5.2 | 11 KV XLPE Cable Size 3x120 sqmm | 20 | Mtr | |
30 | 5.3 | 11 KV XLPE Cable all except above | 20 | Mtr | |
31 | 6 | Under ground laying of Following cable in Single circuit by drill method to Double pole situated at both sides of NH/SH/Railway Crossing complete in all respect. Alongwith filling of 04 nos cable jointing kits | |||
32 | 6.1 | 11 KV XLPE Cable Size 3x70 sqmm | 20 | Mtr | |
33 | 6.2 | 11 KV XLPE Cable Size 3x120 sqmm | 20 | Mtr | |
34 | 6.3 | 11 KV XLPE Cable Size 3x185 sqmm | 20 | Mtr | |
35 | 6.4 | 33 KV XLPE Cable all Size except above | 20 | Mtr | |
36 | 7 | Construction of plinth | 1 | Nos. | |
37 | 8 | Fencing of Plinth | 1 | Nos. | |
38 | 9 | The work of digging of pits, erection of Stay Clamp, Insulator etc. | 50 | Nos. | |
39 | 10 | Installation of X arm | 47 | Nos. | |
40 | 11 | Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect | 1 | Nos. | |
41 | 12 | Mounting of Following Capacity Transformers as per norms complete in all respect - | |||
42 | 12.1 | 10/16 KVA T/F | 6 | Nos. | |
43 | 12.2 | 25 KVA T/F | 18 | Nos. | |
44 | 12.3 | 63 KVA T/F | 11 | Nos. | |
45 | 12.4 | 100 KVA T/F | 4 | Nos. | |
46 | 13 | Fixing of Distribution Box complete in all respect | 10 | Nos. | |
47 | 14 | Guarding at road crossing complete in all respect | 10 | Nos. | |
48 | 15 | Dismantling of Lines | 1 | Km. | |
49 | 16 | Safe back carriage of Scrap (if any) from work site to Byebagh store Shahjahanpur approx distance upto 80 Km including safe loading & unloading. | 5 | Qtl | |
50 | 17 | Fabrication work | 100 | Nos. | |
51 | 18 | Dismantling of T/F 16 KVA/25KVA/63KVA/100KVA | 1 | Nos. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy