Repair Maintenance Of External Electric Supply System Replacement Of Unserviceable Lt Switchgears Panel Boards Cables Etc With Connected Works At Anand Parbat Mil Stn Under Ge North Delhi Cantt 10, GE (N) DELHI CANTT-10-Delhi

Military Engineer Services-MES has published Repair Maintenance Of External Electric Supply System Replacement Of Unserviceable Lt Switchgears Panel Boards Cables Etc With Connected Works At Anand Parbat Mil Stn Under Ge North Delhi Cantt 10. Submission Date for this Tender is 27-10-2020. Electrical Maintenance Tenders in GE (N) DELHI CANTT-10 Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

25658102
Repair Maintenance Of External Electric Supply System Replacement Of Unserviceable Lt Switchgears Panel Boards Cables Etc With Connected Works At Anand Parbat Mil Stn Under Ge North Delhi Cantt 10
Open Tender
Indian
Delhi
GE (N) DELHI CANTT-10
27-10-2020

Tender Details

Repair Maintenance Of External Electric Supply System Replacement Of Unserviceable Lt Switchgears Panel Boards Cables Etc With Connected Works At Anand Parbat Mil Stn Under Ge North Delhi Cantt 10

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: CA NO GE/NORTH- 54/2020-21 : REPAIR / MAINT OF EXTERNAL ELECTRIC SUPPLY SYSTEM, REPLACEMENT OF UNSERVICEABLE LT SWITCHGEARS, PANEL BOARDS, CABLES ETC WITH CONNECTED WORKS AT ANAND PARBAT MIL STN UNDER GE (NORTH) DELHI CANTT-10
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil all as specified and directed. 190 Cum
2 2 All as per above item but Hard/dense soil. 30 Cum
3 3 All as per above item but Soft/disintegrated rock. 20 Cum
4 4 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed. 145 Cum
5 5 Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. 95 Cum
6 6 M&L for sand cushioning for protection of cables with screen wash river sand and punning to proper required cover all as specified and directed. 90 Cum
7 7 M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed. 6560 Nos
8 8 Supplying and laying un-reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx l80mm x 40mm , as specified and directed 355 Nos
9 9 Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked,size of 185 sqmm 3 core suitable for HT 11 KV(E) system, laid in trenches,fixed to pole/wall incl taking down unsv complete all as specified nd directed. Note :- Earth work,cable protection,sand fillings,cable joint shall be measured and paid separately. 30 RM
10 10 All as per above item but size 120 sqmm 3 core 65 RM
11 11 All as per above item but size 95 sqmm 3 core 50 RM
12 12 Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors 10 sqmm 2 core laid in trenches, fixed to pole/wall incl taking down unsv complete any size,type&core complete all as specified and directed. Note:- Earth work,cable protection,sand fillings,cable joint shall be measured and paid separately. 100 RM
13 13 All as per above item but 16 Sqmm 4 Core. 225 RM
14 14 All as per above item but 25 Sqmm 3.5/4 Core. 450 RM
15 15 All as per above item but 35 Sqmm 3.5 Core. 120 RM
16 16 All as per above item but 50 Sqmm 3.5 Core. 75 RM
17 17 All as per above item but 70 Sqmm 3.5 Core. 85 RM
18 18 All as per above item but 95 Sqmm 3.5 Core. 50 RM
19 19 All as per above item but 150 Sqmm 3.5 Core. 35 RM
20 20 All as per above item but 185 Sqmm 3.5 Core. 65 RM
21 21 All as per above item but 240 Sqmm 3.5 Core. 25 RM
22 22 Laying only (Re routing) serviceable any type of cable up to 70 sqmm 2/3/ 3 ½ /4 core size all as specified and directed. (Note:- Excavation, sand, bricks and connected items shell be measured and paid separately). 75 RM
23 23 All as per above item but 95 sqmm to 240 sqmm. 45 RM
24 24 Laying only old bricks over the sand cushioning dry and flat for cable protection. (Note:- Bricks obtained from the removing of UNSV cable and re routing cable) 1950 Each
25 25 Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed.\nNote: (a) Excavation,earth work,cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (d) Material and labour for emergency maintenance work of HT/LT cable line during breakdown by deploying skilled labour and electricians at faulty site having gang of minimum 4 persons including transportation and other tools and plant required at site for fault rectification.(e) Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. In case the contractor or his rep shall not come to the site of breakdown and start attending breakdown within two hours, a penalty of Rs 600 per fault per hour shall be imposed over contractor and shall be deduct from his dues. 18 Each job
26 26 All as per above item but 1100 Volt LT cables\n 12 Each job
27 27 Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. \nNote: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. \n(b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks/PCC cable cover and sand required at site shall be measured and paid separately under respective items of BOQs.\n(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule. 14 Each job
28 28 All as per above item but 11000 Volt HT cables\n 5 Each job
29 29 Material and labour for disconnecting faulty/burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals with suitable size of thimbles and cable glands for Panel Boards for 25 Sqmm 3.5/4 core to 70 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed. 20 Each Job
30 30 Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade incl taking down unsv complete all as directed for the following sizes :- Make - Raychem/M-Seal/Denson
31 30.01 16-50 Sqmm x 3.5 core/ 4 core 6 Each
32 30.02 70-150 Sqmm x 3.5 core 4 Each
33 30.03 185 -240 Sqmm x 3.5 core 2 Each
34 31 Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 to 300 sqmm XLPE armoured aluminium conductor cable incl taking down unsv complete all as specified and directed.Make - Raychem/M-Seal/Denson 6 Each
35 32 All as per above item but out door termination complete. 2 Each
36 33 Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 to 300 sqmm XLPE armoured aluminium conductor cable incl taking down unsv complete all as specified and directed.Make - Raychem/M-Seal/Denson 4 Each
37 34 M&L for painting of transformer/voltage stabilizer of capacity 100 to 500 KVA with synthetic enamel paint (Two coats) of existing colour, with spraying machine, after cleaning, scrabing, preparation of outer surface of transformer including writing of SM No, MES and capacity of transformer complete all as specified and directed. 11 Each Job
38 35 S&F in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers, capacity upto 100 to 500 KVA complete all as specified and directed. 4 Each
39 36 S&F in repairs for temperature gauge for transformers 0-100 degree celsius complete all as specified and directed. 4 Each
40 37 M&L for ON load centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration achieve dielectric strength 50-60 KV complete all as specified and directed.\nNote :- 1. Deficient quantity of Transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule. 2. Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor. 4525 Ltrs
41 38 Supply & filling new transformer oil of having dielectric strength 60 KV to top up level complete all as specified and directed (Make- Powerlink/Powerzone/HP/apolo/indotech) 500 Ltrs
42 39 S&F in repair LT Porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 500 KVA complete 6 Each
43 40 S&F in repair HT 11 KV porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 500 KVA complete 6 Each
44 41 M & L for Hardcore of gauge n exc. 40 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. 1 Cum
45 42 M & L in repairs for duct cover Mild steel plates, chequered, 5mm thick in Fe 410-W (Gde E-250) quality-A with welding including lifting arengment of duct cover complet all as specified and directed. 50 KG
46 43 Servicing of ACBs by taking out Air circuit breaks of capacity 630 to 800 amps from LT panels cleaning all parts internally and externally checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contract, floating contacts, servicing of motor, and charging system and re-fixing it on its original position and testing including testing of control wiring of the respective ACBs by the authorised service engineer and shall submit necessary certificate for the same all as specified. 5 Each Job
47 44 S & F in repairs of shutter assembly suitable for 3 pole ACB upto 800 amps capacity complete with all accessories all as specified. 1 Each
48 45 S & F in repairs of arc chute (set of 3) suitble for 3 pole ACB up to 800 Amps capacity complete with all accessories all as specified. 1 Each
49 46 S & F in repairs of floating isolating contacts (set of 3) suitable for 3 pole ACB upto 800 Amps capacity complete with all accessories all as specified. 1 Each
50 47 Material and labour for servicing /testing of breaker/control panel of VCBs including CT, PT and relays in control panel of of capacity 630 Amps and rating 11 KV complete as details mentioned as under:- (a) Details of servicing of breaker :-\n(i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required .(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish .(xv) Replacement of Dashpot/shock absorbers .(xvi) Replacement of carbon brush of spring charging motor (b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay : - (i) Over current and earth fault relay (d) Testing of followig Aux relay:- (i) DC Supply supervision relay. (ii) Master trip relay Note:- Spares shall be measured and paid separately as catered in under respective items\n 15 Each Job
51 47.01 Isolate contact assembly 5 Each
52 47.02 Auxilary switch 2 Each
53 47.03 Earth contact assembly 1 Each
54 47.04 Closing push button 3 Each
55 47.05 Tripping push button 4 Each
56 47.06 Spring charged indicator 4 Each
57 47.07 ON/OFF indicator 8 Each
58 47.08 Plug & socket assembly 2 Each
59 47.09 Phase barrier (Set of 02 Nos with nuts & bolts) 4 Each
60 47.1 Flexible copper connector 3 Each
61 47.11 Support insulator suitable for ABB Vmax model VCB 8 Each
62 47.12 Manual spring charging handle 3 Each
63 47.13 Tripping coil assembly 3 Each
64 47.14 Closing coil assembly 3 Each
65 47.15 Limit switch 2 Each
66 47.16 Emergency tripping button 2 Each
67 47.17 Shutter assembly 1 Each
68 47.18 Opening lever for circuit breaker racking in/out 2 Each
69 47.19 Vacuum interrupter suitable for 630 amps 11 KV HT VCB, Make- ABB 2 Each
70 48 S&F in repairs of heater suitable for 11 KV HT panel all as specified. Make: As per sample 6 Each
71 49 S&F in repairs of thermostat suitable for 11 KV HT panel all as specified. Make: As per sample 6 Each
72 50 S & F in repairs of LED Lamp as per colour scheme suitable for 110 volt DC supply for mounting on HT Panel all as specified. Make: As per sample 6 Each
73 51 S & F in repairs of digital electronic three phase earth fault and over current relay panel mounting type, 3 phase,110 V ( L-L ), MC61A model of L&T, including necessary connection/modification with suitable and including copper cable and other connected accessories for mounting on existing HT panel, Cat pt No.MC61ANX2200 of L&T /C&S/ABB or Equivalent. 1 Each
74 52 S & F in repairs of power pack unit suitable for 220 volts AC input & 110 volts DC output complete with 12 volts, 7 Ah sealed lead acid batteries and suitable ammeter, voltmeter, switches etc suitable for operation of HT Panel all as specified and directed. Make: MMAXPOWER & Power Pack, Alan electronic systems or equivalent. 2 Each
75 53 S & F in repairs of 2X12V DC battery with Battery charger with suitable burden for motor operation with input voltage of 230 V AC and out put voltage of 24 V DC (make of Battery- Exide/HBL) 2 Each
76 54 S & F in repairs of digital Trivector meter for 11 KV HT Panel mounting type including necessary connection/modification with suitable and including copper cable and other connected accessories for mounting on existing HT panel. Make Conzerve EM 6400 or equivallant 1 Each
77 55 S & F in repairs of TNC switch suitable for operation of VCB 630 amp of ABB V max model make installed in HT panel 11 KV all as specified. Make - as per sample 1 Each
78 56 S & F in repairs of 11KV fuse tubular type, 11KV/1A suitable for operation of HT Panel all as specified and directed. Make: as per sample 12 Each
79 57 S & F in repairs of spout insulator/cable boots suitable for 630 amps HT VCB of ABB V max model make installed in 11 KV HT panel all as specified. 12 Each
80 58 S & F in repairs of motor gear assembly, suitable for ABB V max complete with necessary wiring and accessories all as specified and directed. 1 Each
81 59 Disconnection of all electric connection & taking out old/defective Current Transformer (CT) from 11 KV VCB panel and Supply, fixing, installation & testing of Current transformer, indoor, epoxy cast, 11000 Volts, 50 Hz, ratio 60-30/5A suitable for operation of HT Panel all as specified and directed. Make: STI or equivallent 3 Each
82 60 Labour for cutting and removing grass, vegetation bushes etc from surrounding HT installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed. 100 Sqm
83 61 Labour for trimming of tree branches around the street/security light poles (not less than 2 mtrs) to clear the vegetation including cleaning of nest of birds, creepers on poles and stays etc complete removing and disposed off from the site complete all as specified and directed. 150 Each job
84 62 Supply and laying in replacement of synthatic insulating mat of size 2m x 1m x 12 mm all as specified and directed. 2 Each
85 63 All as per above item but size 2m x 1m x 25 mm. 2 Each
86 64 M & L in repair for PCC root indicator made of PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate suitable for mounting on root of HT cable of width 45cm, depth 10cm & height 100cm overall embedded to the depth not less than 45cm below ground level complete all as specified & directed. 5 Each
87 65 M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme complete all as specified and directed. 80 Per 10 Nos (Per cm of height)
88 66 Removal of UNSV danger notice plate and M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size Complete all as specified and directed. . 10 Each
89 67 All as per above item No 71 but HT, 25x20cm. 15 Each
90 68 Removal of UNSV PCC/Steel pole and M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts, nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable pole with fittings etc complete.(Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items).Complete all as specified and directed. 8 Each
91 69 Demolition of cement concrete of any description and in any position complete all as specified and directed. 18.25 Cum
92 70 M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete Complete all as specified and directed. 8.5 Cum
93 71 M&L for PCC (1:3:6) type C1, (Using 20 mm graded aggregate) as in foundations, for coping, filling and mass concrete with cement plastering finishing all as specified and directed. 9.75 Cum
94 72 M&L for painting of LT electric pole, steel tubular swaged pole (9 mtr long) of any size, any pattern with one coat of aluminium paint over a coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (upto to 1.50 mtr length, 1.50 mtr height of PCC coping) alternatively including numbering the pole serially all as directed . 200 Each
95 73 M&L for two coats of synthetic enamel paint on plastered surfaces as specified colours complete all as specified and directed. 125 Sqm
96 74 M&L for high intensity retro reflective sheet 5cm width length up to 60 cm length as specified colours with heavy duty self adhesive tape for stick on electrical pole complete all as specified and directed. 600 Nos
97 75 M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique with out disturbing top surface of the road and necessary machine including HDPE pipe of 100 mm dia suitable for 0.6 mpa working pressure complete all as specified and directed. Note : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost. 18 RM
98 76 M & L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed. 0.7 Cum
99 77 M & L for steel tubes, light grade galvanised 100 mm bore laid in trenches/walls and spreading for cable cushioning/protection all as specified and directed. 12 RM
100 78 All as per above item but 80 mm bore. 10 RM
101 79 All as per above item but 50 mm bore. 80 RM
102 80 All as per above item but 32 mm bore. 20 RM
103 81 Material & Labour for repairs of cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as specified and directed. 50 Kg
104 82 M&L for street light bracket suitable for street/security light fittings upto 1.5 RM make out of GI pipe of light grade up to 40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed including taking down old corroded one all as directed and specified . 15 Each
105 83 M&L for repairs in PVC, sheathed copper cable of 2.5 sqmm, 3 core for street light connection including taking down unserviceable PVC insulated aluminium conductor cable from steel pole /PCC pole /Jn box all as specified and directed. 200 RM
106 84 S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 25 Watt including taking down old unserviceable one all specified and directed. (Make :Havells/Philips/Wipro) 12 Each
107 85 S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 45 Watt including taking down old unserviceable one all specified and directed (Make :Havells/Philips/Wipro) 22 Each
108 86 S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 60 Watt including taking down old unserviceable one all specified and directed . (Make :Havells/Philips/Wipro) 4 Each
109 87 S&F in repairs for large area flood lighting system LED type IP 66, pressure die cast housing, with heat resistant tempered glass for protection with surge protection system, 120 Watt including taking down old unserviceable one all specified and . (Make :Havells/Philips/Wipro) 10 Each
110 88 S&F in repairs for decorative LED post top fittings 25W Ruby Clear/Coral opal type IP 65 including with all accessories complete along with after taking down old unserviceable one all specified and Make :Halonix/Philips/Wipro) (Note: light grade GI pipe and necessary PCC works shall be measured and paid separately under relevant items) 4 Each
111 89 S&F in repairs for garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution including taking down old fitting, demoliton of brick/PCC work all as specified and directed. (Make :Crompton LBLSN 10 CDL or equivallant inHavells/Philips) (Note: Necessary PCC works shall be measured and paid separately under relevant items) 8 Each
112 90 S&F in repairs for LED type IP 66, bush light with die cast aluminium having with toughened glass 9 W incl fixing arrangements complete all as specified and directed. (Make :Havells/Polycab/Wipro) 6 Each
113 91 S&F in repairs for loop box out door type made out of Engineering plastic one piece moulding type,Bus bar rating 63 Amps 4 strips aluminium with bus bar mounting colour R,Y,B,N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colour, shock prrof, rust proof, fire retardant size 300x 200x 100mm with 10 Amps Kit kat fuse type, having front, opening and locking arrangement, duly fixed on the pole by MS clamp of suitable sizes, all as specified and directed. (Note:- Incoming and outgoing cables suitable size Lugs,Glands rate deemed to be included) 30 Each
114 92 All as per above item but Single phase system 2 strips aluminium bus bar size of 200x150x100mm all as specified and directed. 5 Each
115 93 S & F in replacement of MCCB, 4 pole, 415V AC, fixed type of following capacity; Make: Legrand/L & T /Indo asian/Havells
116 93.01 63Amps with breaking capacity 16kA 8 Each
117 93.02 100 Amps with breaking capacity 16kA 6 Each
118 93.03 125Amps with breaking capacity 16kA 5 Each
119 93.04 160 Amps with breaking capacity 25kA 3 Each
120 93.05 200Amps with breaking capacity 25kA 2 Each
121 93.06 250 Amps with breaking capacity 35kA 1 Each
122 93.07 400Amps with breaking capacity 36kA 1 Each
123 94 S & F in replacement of MCCB, three pole, 415V AC, fixed type of following capacity; Make: Legrand/L & T /Indo asian/Havells
124 94.01 100Amps with breaking capacity 16kA 1 Each
125 94.02 125Amps with breaking capacity 16kA 1 Each
126 94.03 200Amps with breaking capacity 36kA 1 Each
127 94.04 300Amps with breaking capacity 36kA 1 Each
128 95 S & F in replacement of onload changeover switch, four pole, 415V AC,of following capacity; Make: HPL/Havells/Standard
129 95.01 100Amps 1 Each
130 95.02 250Amps 1 Each
131 96 M&L for heavy duty capacitor, 415 Volt, 50Hz, 3 phase type including testing, commissioning after taking down old unserviceable capacitors of following rating. Make :- EPCOS / GE/ABB
132 96.01 1 KVAR 2 Each
133 96.02 3 KVAR 4 Each
134 96.03 5 KVAR 6 Each
135 96.04 10 KVAR 4 Each
136 96.05 15 KVAR 2 Each
137 96.06 25 KVAR 2 Each
138 96.07 50 KVAR 1 Each
139 97 S&F in replacement 4 pole power contactor MCX 23 type for Street light/APFC panel complete all as specified and directed. Make- L&T/C&S. 2 Each
140 98 All as per above item but 3 pole MNX 25 type complete. 1 Each
141 99 M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing feeder piller, removal of complete LT feeder piller with necessary T&P, breaking of plinth, shifting and fixing of same feeder piller at new location including necessary eath work and PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) work as directed, necessary welding work for opening doors, hinges and connecting of incoming and outgoing cables, inclusive of two coats synthetic enamel paint of existing colour over one coat of primer, incl testing & commissioning etc., complete all as directed. Note: The cost of Aluminium thimbles/lugs and cable gland etc., as reqd at site is included in quoted rate. 2 Each job
142 100 M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing LT feeder piller indoor/out door type, powder coated painting over a cleaning, scrabing with salt paper and removal of dust particles complete with necessary T&P, and refixing the same as incoming and outgoing cables as existing. 15 Each job
143 101 S & F in repairs of LT panel Voltmeter digital type for 415 Volts, 3 phase system, rating 0-500 V complete suitable for operation of LT Panel all as specified and directed. Make: AE or equivallant 2 Each
144 102 S & F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-200 A complete suitable for operation of LT Panel all as specified and directed. Make: AE or equivallant 1 Each
145 103 S & F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-400 A complete suitable for operation of LT Panel all as specified and directed. Make: AE or equivallant 2 Each
146 104 S&F in repairs for informatory/eqpt history sign boards of size not less than 900 x 600 mm rectangular type with 2mm thick MS sheet plain type made out of angle iron channels frame, back ground and epqt history details(i.e. Name, Make, Ser No,Capacity of eqpt, Vintage, SM/MES No etc.,) with high intensity retro reflective sheet letters as specified colours (blue and white) complete all as specified and directed. 4 Each Job
147 105 S&F in repairs for electrical shock and treatment and other safety charts,laminated and wall hanging type complete all as specified and directed. 6 Each
148 106 S&F in repairs for fire Extinguisher CO2 (ABC type) maximum capacity of 4.5 Kg. as per the IS 2878 complete all as specified and directed. 4 Each
149 107 S&F in repairs for lead acid batteries of 12 Volts, 150-180 AH, 22-28 plates,maintenance free type including accesories like terminal clamps, copper cable of required size and length, petroleum jelly and baterry initial charging all as specified and as directed. Make Exide/Amar Raja/Luminious/HBL 1 Each Job
150 108 Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed 15 Each\nJob
151 109 Supply, install, testing and commissioning of factory made LT panel of suitable size for 3 phase 415 Volts indoor type cubical compartmentalised dust,weather,vermin and water proof fabricated out of 2 mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, suitable for including 300 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panel and submit test certificate complete with following incoming/out going accessories:- (Make of panel- Adlec/SMS panels&switch gears/Tricolite, Make of ACB/MCCB/MCB- Havells/Indo asian,Make of accessories- L&T/AE) IN COMING - (a) MCCB 250 A, 4P, 50 KA - 02 Nos(I/C No 01 for Main supply,No 02 for DG supply incoming) (b) On load Change over switch 250 Amps - 01 No incl Handle with door interlock kit is integral part of the Changeover Switch. OUT GOINGS - (a) MCCB 4 Pole, 415 volts, 200 Amps 36 KA - 01 No (b) MCCB 4 Pole, 415 volts, 100 Amps 25 KA - 01 Nos (d) Suitable rating accessories Digital Volt meter(01 No), Digital Ammeter(01 No),MCB 6 Amps SP 10 KA(03Nos), C.T.s 0-300Amps (03 Nos), R,Y,B Indicating lights(03 Nos) etc., complete all specified and directed. 1 Each\nJob
152 110 Schdule of Credit - 55159.00
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail