Cleaning Of Oh Tank Ug Sump And Other Misc Work At Different Pump Houses And Repair/Replacement Of Safety Measures Including Water Level Indicator In The Area Of Age E/M Ext ( Ws ) Under Ge E/M Lucknow, Lucknow-Uttar Pradesh

Military Engineer Services-MES has published Cleaning Of Oh Tank Ug Sump And Other Misc Work At Different Pump Houses And Repair/Replacement Of Safety Measures Including Water Level Indicator In The Area Of Age E/M Ext ( Ws ) Under Ge E/M Lucknow. Submission Date for this Tender is 26-10-2020. Indicators and Reagents Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25649881
Cleaning Of Oh Tank Ug Sump And Other Misc Work At Different Pump Houses And Repair/Replacement Of Safety Measures Including Water Level Indicator In The Area Of Age E/M Ext ( Ws ) Under Ge E/M Lucknow
Open Tender
Indian
Uttar Pradesh
Lucknow
26-10-2020

Tender Details

Cleaning Of Oh Tank Ug Sump And Other Misc Work At Different Pump Houses And Repair/Replacement Of Safety Measures Including Water Level Indicator In The Area Of Age E/M Ext ( Ws ) Under Ge E/M Lucknow

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : CLEANING OF OH TANK UG SUMP AND OTHER MISC WORK AT DIFFERENT PUMP HOUSES AND REPAIR/REPLACEMENT OF SAFETY MEASURES IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Wash out complete water by pumping set /manually of existing underground sump/ static water tank up to 50000 gallons capacity including removing deposited sand from inside the tank, scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus deposits stains using wire brush, filling of cavaties inside of tank with CM 1:1 with quick setting cement and applying two coat of white wash inside & writing date of cleaning , complete all as specified and as directed by Engineer- in- Charge. Note:-\n1.All type of T & P, Labour & pumping set etc shall be arranged by the contractor and rate for the same will be deemed to be included in the quoted rate. \n2.Contractor will dispose off the material taken out from the sump at a distance upto 50 Mtr as ddirected by Engieneer-in-Charge. \n3.Contractor will clean the surroundings of tank upto 3 mtr around the plinth of the tank. 3 Each Job
2 2 All as serial item No. 01 above but cap upto 100000 GLNS , complete all as specified and as directed by Engineer- in- Charge. 2 Each Job
3 3 All as serial item No. 01 above but cap upto 200000 GLNS , complete all as specified and as directed by Engineer- in- Charge. 1 Each Job
4 4 All as serial item No. 01 above but cap upto 400000 GLNS complete all as specified and as directed by Engineer- in- Charge. 1 Each Job
5 5 Cleaning inside RCC OH reservoirs capacity 400000 gallons at 22 metre staging including removing deposit sand from inside the tank scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus deposits starins using wire brush filling of cavaties inside of tank with cm 1:1 with quick cement and applying one coat of white wash inside including dome & writing date of cleaning complete all as specified and directed including repair to wash out system if required for proper flushing of over head tank , complete all as specified and as directed by Engineer- in- Charge.\nNote :-\n1. All type of T&P and Labour etc shall be arranged by the contractor and rate for the same will be deemed to be included in the quoted rate. \n2. Contractor will dispose off the material taken out from the tank at a distance upto 50 Mtr as directed by Engieneer-in-Charge. \n3. Contractor will clean the surroundings of Tank upto 5 mtr around from the plinth of the tank. 1 Each Job
6 6 All as per serial item No 05 above but of tank capacity 200000 gallons , complete all as specified and as directed by Engineer- in- Charge. 3 Each Job
7 7 All as per serial item No 05 above but tank capacity 100000 gallons , complete all as specified and as directed by Engineer- in- Charge. 20 Each Job
8 8 All as per serial item No 05 above but capacity up to 50000 gallons. , complete all as specified and as directed by Engineer- in- Charge. 10 Each Job
9 9 Taking out monoblock Pump set / Horizontal submersible pumping set upto 5 HP for FOUNTAIN at varrious location in Lucknow Cantt with connected item such as suction pipe cable etc including disconnecting mechanically and electrically , complete all as specified and as directed by Engineer- in- Charge. 8 Each Job
10 10 Transportation of monoblock Pump set / Horizontal submersible pumping set upto 5 HP from site (Lucknow Cantt) to contractor workshop and vice versa, complete all as specified and as directed by Engineer- in- Charge. 8 Each Job
11 11 Dismantling monoblock Pump set / Horizontal submersible pumping set upto 5 HP for repair and reassembling after repair , complete all as specified and as directed by Engineer- in- Charge. 8 Each Job
12 12 Rewinding of monoblock Pump set / Horizontal submersible motor capacity 5 HP with Copper wire /PVC insulated copper wire of appropriate size, packing material etc including removal of unserviceable winding cleaning slots etc , complete all as specified and as directed by Engineer- in- Charge. 2 Each Job
13 13 All as serial item No. 12 above but cap 3 HP , complete all as specified and as directed by Engineer- in- Charge. 2 Each Job
14 14 All as serial item No. 12 above but cap 2 HP , complete all as specified and as directed by Engineer- in- Charge. 2 Each Job
15 15 All as serial item No. 12 above but cap 1 HP , complete all as specified and as directed by Engineer- in- Charge. 2 Each Job
16 16 PVC insulated three core submersible cable 2.5 Sqmm fixed as in replacement , complete all as specified and as directed by Engineer- in- Charge. 200 RM
17 17 PVC insulated three core submersible cable 4.0 Sqmm fixed as in replacement , complete all as specified and as directed by Engineer- in- Charge. 250 RM
18 18 DOL starter for single phase motor, 220 V upto 3 HP Motor as in replacement , complete all as specified and as directed by Engineer- in- Charge. 2 Each
19 19 DOL starter for single phase motor, 220 V 5 HP Motor as in replacement , complete all as specified and as directed by Engineer- in- Charge. 1 Each
20 20 Brickwork with sub class 'B' , straight or curved on plan exceeding 6.0 m mean radius built in cement sand mortar 1:6 in and including demolition of brickwork or stone boulder masonary built in cement mortar ,complete all as specified and as directed by Engineer -in-Charge 10 Cum
21 21 Plain cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping on supporting pillar for pipe wall etc ,complete all as specified and as directed by Engineer -in-Charge 4 Cum
22 22 Plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) in surface channel & drain etc , complete all as specified and as directed by Engineer- in- Charge. 4 Cum
23 23 Rendering 10mm thick on other than fair faces of brick wall or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement ,complete all as specified and directed by Engineer-in- Charge. 300 Sqm
24 24 GI nut, bolts each with 01 Nut and two Nos washers of any size and length , complete all as specified and as directed by Engineer- in- Charge. 35 Kg
25 25 Terminal plate 3 phase six wire bakelite, star/delta connection as required at site with brass studs three nuts and two washers size 6 to 8 mm as per site requirement , complete all as specified and as directed by Engineer- in- Charge. 4 Each
26 26 PVC fibre blades with split pin suitable for cooling system of motor to match with the fan cover as required at site for 3 HP to 5 HP motor , complete all as specified and as directed by Engineer- in- Charge. 3 Each
27 27 Cutting and threading MS column pipe 150/100/80 mm threading upto 75mm length or , complete all as specified and as directed by Engineer- in- Charge. 7 Each Job
28 28 Ball/roller/thurst bearing of electric motor/pump sets including turning, polishing and greasing etc for Thurst bearing No. 6220/6218 sizes , complete all as specified and as directed by Engineer- in- Charge \nMake of bearing - SKF/NMC. 10 Each
29 29 All as per serial item No 28 above but Ball bearing No. 6314, 6315 ,6316. 10 Each
30 30 All as per serial item No 28 above but Ball bearing No. 6311, 6312 ,6313. 10 Each
31 31 All as per serial item No 28 above but Ball bearing No. 6308, 6309 ,6310. 10 Each
32 32 All as per serial item No 28 above but Ball bearing No. 6201, 6202, 6203. 10 Each
33 33 All as per serial item No 28 above but Ball bearing No. 6204, 6205, 6206. 10 Each
34 34 Gun metal bush bearing Upto 3 HP sizes of induction motor/pump including turning, polishing, greasing and remetaling of shaft etc ixed as in replacement , complete all as specified and as directed by Engineer- in- Charge. 8 Each Job
35 35 All as per serial item No 34 above but 5/7.5 HP 8 Each Job
36 36 All as per serial item No 34 above but 10 HP & above 10 Each Job
37 37 Cast iron non return valve PN-1 flanged ends suitable for 150 mm bore including jointing material ixed as in replacement , complete all as specified and as directed by Engineer- in- Charge. 10 Each
38 38 Cast iron non return valve PN-1 flanged ends suitable for 200 mm bore including jointing material ixed as in replacement , complete all as specified and as directed by Engineer- in- Charge. 2 Each
39 39 Painting of pipe lines with two coat of synthetic enamel paint as per colour code after cleaning and removing existing dust and dirt on existing painted surfaces complete all as specified and directed of 200 mm bore vertical with over head tanks from GL upto 21 Mtr above GL sizes , complete all as specified and as directed by Engineer- in- Charge.:-\nNote:- The rate for scafolding etc deemed to be included in the quoted rates. 800 RM
40 40 All as per serial item No 39 above but 150/100mm bore vertical with over head tanks from GL upto 21 Mtr above GL 3000 RM
41 41 All as per serial item No 39 above but 150/200 mm bore horizontal/vertical pipe along with Sluice valve/ NRV at GL for header/inside/Outside of Pump House 450 RM
42 42 All as per serial item No 39 above but 100/80 mm bore horizontal/vertical pipe along with Sluice valve/ NRV at GL for header/inside/Outside of Pump House 350 RM
43 43 Sign writing on pipe/pillar/electrical control panel/DG Set & marking of indication for water supply installation Size of letter upto 25mm , complete all as specified and as directed by Engineer- in- Charge. 2000 Per letter
44 44 All as per serial item No 43 above but size of letter above 25mm upto 50mm 1000 Per letter
45 45 All as per serial item No 43 above but size of letter above 50mm upto 75mm 1000 Per letter
46 46 All as per serial item No 43 above but size of letter above 75mm upto 100mm 750 Per letter
47 47 All as per serial item No 43 above but size of letter above 100mm upto 200mm 500 Per letter
48 48 Repair to pipe line inside the RCC OH reservoir at an approx height 25 Mtr above the normal GL complete all as specified and directed for the cutting in position 150 mm bore CI /DI pipe class 'B' /K-9 , complete all as specified and as directed by Engineer- in- Charge. 25 Each Job
49 49 DI pipe 150mm bore class K-9 in (as per existing) True vertical position in any length , complete all as specified and as directed by Engineer- in- Charge. 260 RM
50 50 Flanged joint for DI pipe 150mm bore , complete all as specified and as directed by Engineer- in- Charge. 50 Each
51 51 Cast iron specials 'ISI marked' for pressure water mains up to 150 mm bore spigot and socket Tee,pieces, single or double branch connection or collar etc. in and including taking down old unservicable C I specials, complete all as specified and directed by Engineer-in-Charge.\nNote - Excavation and earth work and joints shall be measured and paid for separately. 600 Kg
52 52 Cutting in position 200 mm bore CI /DI pipe class 'B' /K-9 , complete all as specified and as directed by Engineer- in- Charge. 5 Each Job
53 53 DI pipe 200 mm bore class K-9 (as per existing) in true vertical position in any length , complete all as specified and as directed by Engineer- in- Charge. 70 RM
54 54 Flanged joint for DI pipe 200mm bore , complete all as specified and as directed by Engineer- in- Charge. 20 Each
55 55 Water level indicator of OHT 21 head and 90 mtr apart from the tubewell complete kit in all manners as approved by E-in-C's Br, AHQ including taking down of old unserviceable water level indicator , complete all as specified and as directed by Engineer- in- Charge.\nMake : IE Co or equivalent of Servel/ Surya Electronics & Control 15 EACH JOB
56 56 Cable joint kit suitable for 0.5 Sq mm 10 pairs of copper wire cable of water level indicator , complete all as specified and as directed by Engineer- in- Charge. 10 EACH JOB
57 57 Supplying, laying or fixing, jointing and testing solid PVC insulated , 10 pairs, individual shielded for interference rejection, armoured PVC sheathed 1100 Volts garde 0.5 sqmm instruemental cable ISI-5608 marked ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. including taking out unserviceable cable , complete all as specified and as directed by Engineer- in- Charge. \nNote :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items.\n\n\n 250 RM
58 58 Star delta starter fully automatic oil cooled with auto transformer and first filiing of transformer oil complete with suitable size of cable for connection between starter to auto tranformer suitable for 7.5 to 15 HP, 3 Phase, 415 V electric motar including necessary connection and fixed on stand made out of angle iron 40 X 40 X 4 mm size including taking out unserviceable cable , complete all as specified and as directed by Engineer- in- Charge. \nMake: Bharat Cutler Hammer/Maxwell /JSL. 2 Each Job
59 59 All as per serial item No 58 above but of the capacity 20 to 25 HP. 3 Each Job
60 60 All as per serial item No 58 above but of the capacity 25 to 30 HP. 3 Each Job
61 61 All as per serial item No 58 above but of the capacity 30 to 50 HP. 3 Each Job
62 62 Contactor ML-2, 3 pole, 415 Volt, 32Amps rating including taking out unserviceable contractor , complete all as specified and as directed by Engineer- in- Charge. 3 Each Job
63 63 Contactor ML-3, 3 pole, 415 Volt, 40Amps rating ncluding taking out unserviceable contractor , complete all as specified and as directed by Engineer- in- Charge. 3 Each Job
64 64 Single phase preventor to prevent against single phasing, reverse phasing with wiring & testing including taking out unserviceable single phase preventor , complete all as specified and as directed by Engineer- in- Charge. 20 Each Job
65 65 Submersible Flat copper stranded Cable 1100 V grade of size 10 Sqmm, 3 core including taking out unserviceable cable , complete all as specified and as directed by Engineer- in- Charge. 100 RM
66 66 Submersible Flat copper stranded Cable 1100 V grade of size 16 Sqmm, 3 core including taking out unserviceable cable , complete all as specified and as directed by Engineer- in- Charge. 100 RM
67 67 Servicing of motorised Butterfly Valve-80 mm /100 mm i.e. removing , cleaning , checking for wear & tear , refixing,testing ,installing, comissioning as specified & directed by the Engineer- in-Charge. \nNote:- Spares shall be measured and paid separately if needed. 2 Each\n Job
68 68 Servicing of motorised Butterfly Valve-150/200/250 mm i.e. removing , cleaning , checking for wear & tear , refixing, testing,installing ,comissioning as specified & directed by the Engineer - in-Charge. \nNote:- Spares shall be measured and paid separately if needed. 4 Each\n Job
69 69 Capacitor for Actuator suitable for 80mm / 150mm / 250mm Butterfly valve including taking out unserviceable cable , complete all as specified and as directed by Engineer- in- Charge. 4 Each
70 70 Actuator Adoptor for 150 mm dia butterfly Valve with key , including taking out unserviceable cable , complete all as specified and as directed by Engineer- in- Charge. \nMake:-Ritetork/Hasse hofener. 4 Each
71 71 Supply only Electric motor suitable for Actuator for 100 mm dia butterfly Valve , complete all as specified and as directed by Engineer- in- Charge. \nMake:- SD Tork / Emtork / Hassel / SM Instrumentation. 3 Each
72 72 Supply only Electric motor suitable for Actuator for 150 mm dia butterfly Valve , complete all as specified and as directed by Engineer- in- Charge. .\nMake:- SD Tork / Emtork / Hassel / SM Instrumentation. 3 Each
73 73 Supply only Electric motor suitable for Actuator for 200 mm dia butterfly Valve , complete all as specified and as directed by Engineer- in- Charge. .\nMake:- SD Tork / Emtork / Hassel / SM Instrumentation. 3 Each
74 74 Supply only Electric motor suitable for Actuator for 250 mm dia butterfly Valve , complete all as specified and as directed by Engineer- in- Charge. \nMake:- SD Tork / Emtork / Hassel / SM Instrumentation. 3 Each
75 75 Copper conductor cables ,6 core ,1.5 sqmm nominal cross sectional area multistranded armoured , 1100 volts grade heavy duty cable PVC insulated and PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc including taking down of old unservicable cable , complete all as specified and as directed by Engineer- in- Charge. . 1000 RM
76 76 Collecting sample of water in sample bottle and Testing of water samples of 1 bore wells located in different pockets of cantonment area Lucknow required to be tested for the following parameters. Necessary action may please be taken to get it tested from state public health laboratory or NABL Accredited Lab , complete all as specified and as directed by Engineer- in- Charge. .\nNote : The Parameter to be tested as per IS : 10500-2012: Colour, odour, taste, turbidity, PH, Total dissolved solids, Aluminum Ammonia, Anionic detergents,barium,boron,calcium, chloramines,chloride,copper,fluoride,free residual chlorine, iron, magnesium, manganese, mineral oil, nitrate ,selenium, phenolic compounds, silver, sulphate, sulphide, total alkalinity, total hardness, zinc ,cadmium, cyanide, lead, mercury, nickel, molybdenum, polychlorinated biphenyl, polynuclear aromatic hydro carbonates, total arsenic, total chromium, broomcorn, dibromochloromethane, bromodichloromethane chloroform, pesticides, E.coil, coli form. \n 200 Each Job
77 77 Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil , complete all as specified and as directed by Engineer- in- Charge.\n 120 Cum
78 78 Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil , complete all as specified and as directed by Engineer- in- Charge.\n 90 Cum
79 79 Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.\n 30 Cum
80 80 Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling , complete all as specified and as directed by Engineer- in- Charge. \nNote :- Punned thickness shall only be considered for payment\n 48 Cum
81 81 M&L laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.\n\n 6000 Each
82 82 S&F in repair 5.4mm thick MS black column pipe ( conforming to IS-4270 ) 80mm dia , 3.00 long consisting 02 N0s MS flange heavy duty screwed and drilled, fiange welded inside and outside surfaces of column pipe, including providing and welded FI 25x5 mm-4 Nos covering 50mm on pipe and flange and applying two coats of synthetic enamel paint over one coat of primer , complete all as specified and as directed by Engineer- in- Charge. 90 Each pipe
83 83 S&F in repairs 5.4mm thick MS black column pipe ( conforming to IS-4270 ) 100mm dia , 3.00 long consisting 02 N0s MS flange heavy duty screwed and drilled, fiange welded inside and outside surfaces of column pipe ,including providing and welded FI 25x5 mm-4 Nos covering 50mm on pipe and flange and applying two coats of synthetic enamel paint over one coat of primer , complete all as specified and as directed by Engineer- in- Charge. . 25 Each pipe
84 84 Supply & installion in repairs chequered rubber mat of size 2000 mm x 1000 mm x 12.5 mm ISI Marked , complete all as specified and as directed by Engineer- in- Charge. \nMake : Jyoti. 10 Each
85 85 Dismantling and taking out unservicable off load change over switch and Supplying and fixing on walls with suitable size Mild Steel Clamps, new off load changeover 4 Pole, 100 Amps with sheet metal enclosure, side handle operated including making connections and testing , ISI Marked , complete all as specified and as directed by Engineer- in- Charge. .\n\n 5 Each Job
86 86 S&F water pressure gauge 0-150 Lbs /10.6 Kg complete with and including brass stop cock , in repairs , complete all as specified and as directed by Engineer- in- Charge. 20 Each
87 87 S & F in repair and testing reflux valve (non return valve) swing type single door pattern CI suitable for 150 mm bore pipe heavy duty both end flanged confirming to IS-5312 of 1969 ,PN 1 complete with Neoprene rubber gasket, nuts, bolts and washers etc. , complete all as specified and as directed by Engineer- in- Charge. 2 Each Job
88 88 Taking out of submersible pump of any capacity at any depth from the borewell with the help of chain pulley block including disconnecting the motor electricty & keeping aside safely & lowering the pump & motor assembly after development of the borewell & connecting the pump electricaaly & testing for smooth functioning all as speified and directed as EIC. Note :- Cost of Gaskets, U/S nuts and bolts, consumable & T&P are included in the quoted rates , complete all as specified and as directed by Engineer- in- Charge. 10 Each Job
89 89 Developing tubewell by compressed air with minimum pressure of 10Kg/Sq cm to 30 Kg / Sqcm and minimum 450 CFM all as specified in IS 11189-1985, para 4.3 and directed by Enigineer-in-Charge. \nNote :- (i). Compressor, pump, pipe and other allied items shall be arranged by the contractor and nothing extra shall be admissible on this account.\n(ii). Draining shall be approved by the GE. 100 Per Hour
90 90 Developing tube well by over pumping for tube well complete after development by compressor and water shall be used only after receipt of satisfactory test result as per IS, all as specified and directed. \nNote :- Over pumping will be carried out by pumping the water at higher capacity i.e. not less than 50% above the yield of bore well. Cost of arranging pump and compressor is deemed to be included in the unit rate quoted complete all as specified and directed. 300 Per Hour
91 91 M&L for pea gravel of 2 mm to 4 mm size of approved quality as ordered to pack around the casing during development by compressor/by over pumping through pipes in bore well in annular space between well assembly and borehole wall the pea gravel should be thoroughly washed before sorrounding in the well and treated, with suitable amount of sodium hexa-metaphosphate for 24 hrs before developing by compressed air complete all as specified and directed. 60 Cum
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail