Repair And Maintenance Of Bunker No . 03 To 06 ( 04 Nos . ) At Nhpc Colony , Gingle, URI POWER STATION-Jammu And Kashmir

National Hydroelectric Power Corporation Limited has published Repair And Maintenance Of Bunker No . 03 To 06 ( 04 Nos . ) At Nhpc Colony , Gingle. Submission Date for this Tender is 27-10-2020. Bunker Tenders in URI POWER STATION Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25645494
Repair And Maintenance Of Bunker No . 03 To 06 ( 04 Nos . ) At Nhpc Colony , Gingle
Open Tender
Indian
Jammu And Kashmir
URI POWER STATION
27-10-2020

Tender Details

Repair And Maintenance Of Bunker No . 03 To 06 ( 04 Nos . ) At Nhpc Colony , Gingle

Key Value

Document Fees
INR 590 /-
EMD
INR 20000.0 /-
Tender Value
INR 9.89 Lakhs /-

BOQ Items

Name of Work: Repair and Maintenance of Bunker No. 03 to 06 (04 Nos.) at NHPC Colony, Gingle.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 72.6 sqm
2 2 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete: In colour such as White, Ivory, Grey, Fume Red Brown 29.56 sqm
3 3 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 239.52 sqm
4 4 Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) 6.24 sqm
5 5 Centering and shuttering including strutting, propping etc. and removal of form for: Shelves (cast-in-situ) 15.2 sqm
6 6 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 1.32 Cum
7 7 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. 244.96 kg
8 8 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 88.84 sqm
9 9 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) 251.28 sqm
10 10 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : of area of 3 sqm. and below 16 Each
11 11 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners: Second class kail wood 0.224 Cum
12 12 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws; 30mm thick 12.4 sqm
13 13 Providing and fixing factory made UPVC door frame made of UPVC extruded, section having an overall dimension, as below (tolerance+/-1mm with wall thickness 2.0mm +/-0.2mm, corners of the door frame to be joined with galvanized brackets and stainless steel screws, joint mitred and plastic welded. The hinges side vertical of the frames reinforced by galvanized MS tube of size 19x19mm and 1mm +/-0.1mm wall thickness and three numbers stainless steel hinges fixed to the frame complete as per manufacturers’ specifications and direction of engineer-in-charge): Extruded section profile size 42x50mm 45.6 metre
14 14 Providing and fixing to existing door frames: 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places 11.4 sqm
15 15 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm 32 Each
16 16 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete: 125mm 32 Each
17 17 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete: 1 mm thick 174.2 sqm
18 18 Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre, two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications 174.2 sqm
19 19 Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 33.85 sqm
20 20 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work 33.85 sqm
21 21 Finishing walls with water proofing cement paint of required shade: Old work (one or more coats applied @ 2.20 kg/10sqm) over priming coat of primer applied @ 0.80 liters/10sqm complete including cost of priming coat. 77.48 sqm
22 22 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with lSI marked white solid plastic seat and lid. 8 Each
23 23 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 16 Each
24 24 Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 8 Each
25 25 Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. 8 Each
26 26 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. (Internal work-Exposed on wall): 15 mm dia. nominal bore (Medium grade) 33.2 rm
27 27 Providing and fixing uplasticized PVC connection pipe with brass unions, 45 cm length: 15 mm nominal bore 16 each
28 28 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. 8 each
29 29 Providing and fixing soil, waste and vent pipes : :100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 19.2 metre
30 30 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 328.36 sqm
31 31 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A 32 Point
32 32 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 52 P/Mtr
33 33 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 76 P/Mtr
34 34 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required - 5/6 amps switch 4 each
35 35 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required - 3 pin 5/6 A socket outlet 4 each
36 36 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 8 each
37 37 Supplying and fixing brass batten/ angle holder including connection etc. as required. 16 each
38 38 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole 10 A 4 each
39 39 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. -Single pole 20A 4 each
40 40 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. -Double pole 32A 4 Each
41 41 Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door 4 Each
42 42 LED Tube Fitting, 18-20W, 4 Feet 8 Each
43 43 Exhaust Fan 8 Each
44 44 Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc Upto 450 mm sweep 8 Each
45 45 PVC insulated Aluminium conductor cable size 2*16 sqmm 120 mtr
46 46 GST@18% 59 1 Lot
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail