Providing Of Additional Security Lights , Street Lights And Demolition Of 04 Nos Borewell Structures At Certain Units At Chandimandir Cantt, Chandimandir Cantt-Haryana

Military Engineer Services-MES has published Providing Of Additional Security Lights , Street Lights And Demolition Of 04 Nos Borewell Structures At Certain Units At Chandimandir Cantt. Submission Date for this Tender is 29-10-2020. Street Lighting Tenders in Chandimandir Cantt Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

25636991
Providing Of Additional Security Lights , Street Lights And Demolition Of 04 Nos Borewell Structures At Certain Units At Chandimandir Cantt
Open Tender
Indian
Haryana
Chandimandir Cantt
29-10-2020

Tender Details

Providing Of Additional Security Lights , Street Lights And Demolition Of 04 Nos Borewell Structures At Certain Units At Chandimandir Cantt

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : PROVN OF ADDITIONAL SECURITY LIGHTS, STREET LIGHTS AND DEMOLITION OF 04 NOS : BOREWELL STRUCTURES AT CERTAIN UNITS AT CHANDIMANDIR CANTTPROVN OF ADDITIONAL SECURITY LIGHTS FOR DARK PATHCES FROM 37 INF BDE TO COMD MARG IN CHANDIMANDIR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Demolition of brick work or stone / boulder masonry, built in cement or cement lime mortar in any position / any location and of any type above ground level, including cement concrete articles and removing rubbish / dismantled / demolished matrials outside to MoD land complete all as directed. 1 174 CuM
2 2 All as per the description of serial item no. 1 here-in-above but below ground level to a depth n.exceeding 1.50 metre including excavation, returning, filling in soils to make good dismantled / demolished and excavated areas and removing rubbish / dismantled / demoished materials outside the MoD land complete all as directed. 2 20 CuM
3 3 Demolition of unreinforced concrete of any position, any location and any thickness, below or above ground level and removing rubbish / dismantled / demolished materials outside the MoD land complete all as directed. 3 56 CuM
4 4 Demolition of reinforced cement concrete as in roof slabs, floor slabs, beams, stair cases , lendings, chajjas and similar works in any position, seperating steel reinforcement from concrete from measurement purpose and removing all rubbish / dismantled / demolished materials outside the MoD land complete all as directed. Note : Separating steel reinforcement and measuring quantity of steel reinforcement shall be paid for seperately. 4 46 CuM
5 5 Separating steel reinforcement from demolished reinforced cement concrete and stacking properly for measurement, complete all as directed 5 10 Quintal
6 6 Taking down steel windows with steel guard bars, each window exceeding 1.00 Sqm but not exceeding 1.50 Sqm and removing from site of work outside to MoD land complete all as directed 6 32 Each
7 7 Taking down chowkhats or frames (Steel or wooden) exceeding 1.50 Sqm but not exceeding 4.00 Sqm each and removing from site of work outside to MoD land complete all as directed 7 20 Each
8 8 Taking down steel rolling shutters or frames exceeding 5.00 Sqm but not exceeding 12.00 Sqm each and removing from site of work outside to MoD land complete all as directed 8 4 Each
9 9 Dismantling structural steel work including doors, gates but excluding framed trusses etc and removing from site of work outside to MoD and complete all as directed 9 2.2 Quintal
10 10 Dismantling brick tiles or terracing tiles on roofs including bedding mortar and removing from site of work outside to MoD and complete all as directed 10 390 SqM
11 11 Excavation in trenches for foundations, laying of pipes/cables, erecting of poles etc not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out, in any type of soil, complete all as specified and as directed. 11 244 CuM
12 12 All as per the description of serial item no. 11 here-in-above but depth exc 1.5 mtr and not exc 3 mtr. 12 2 CuM
13 13 Returning filling in soils including spreading leveling, watering and well ramming in layer not exceeding 25 cm thick at a level not exceeding 1.50m above the starting point or complete all as specified and as directed . 13 215 CuM
14 14 Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed as directed by the Engineer-in-charge in low lying areas. 14 31 CuM
15 15 Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in foundations, filling and mass concrete complete all as specified and as directed. 15 21.4 Cum
16 16 Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, benching, bed plates, bed blocks and the like including necessory formwork as required including finishing exposed surfaces of concrete even and smooth complete all as specified and as directed. 16 3.7 Cum
17 17 Supply, erection and fixing in position 9.00 metre long, Steel tubular swaged poles complete with mild steel base plate, flat top welded type 410, SP-31 IS 2713 marked, drilling of necessary holes including bolts, nuts and washers as requried and painted with two coats of Aluminium paint over a coat of red oxide primer on exposed surfaces of poles and two coats of black bituminous paint throughout internally and externally upto the planting depth including painting 30 cm wide strips upto 1.20 m height from ground level in yellow and black colour synthetic enamel paint in alternate and marking numbering of pole at height and pattern as directed complete all as specified and as directed. Note : Excavation and earth work and concrete work shall be measured and paid for seperately. 17 40 Each
18 18 Supply, laying, jointing, testing and commissioning LT underground electric cable XLPE insulated, PVC sheathed, armoured heavy duty 1100 volts grade heavy duty aluminium conductor of cross sectional area 25 sqmm 4 core laid in trenches/ducts/along poles/through pipe /on wall/under road etc complete all as specified and as directed. 18 1850 RM
19 19 Multi stranded copper cable PVC insulated unsheathed 1100 volts grade of size 2.5 sqmm 3 core for connection from junction box to light fitting and making connections and testing for functioning of light fitting complete all as specified and as directed.\n 19 360 RM
20 20 Supply and fixing of 90 watt with system efficacy (lm/w) not less than 100 lumens per watt total system lumens not less than 9000 lumens, LED Inverter Street Light with with inbuilt RTC (Real Time Clock) made of Pressure Dia Cast Aluminium Housing, TOP MAINTANABLE and with clear heat resistant toughened glass, should have secondary lens for better optics, should have LM 80 certified LED with contstant current RTC enabled electronic driver with 5KV SPD, IP 66 protection class, Street light shall have Li-ion battery with minimum 5200 mAh capacity and shall have >1.5 hrs battery backup in case of power failure, Efficacy>100LPW, CRI>70, THD<10%,PF>0.95, Cut off voltage at 300V+ 10% and suitable for 50mm mounting pipe. Notes:-\n1. Each luminaire should be printed on the luminaire fittings as "MES", CA No: GE(U)/CHM-24/2020-21. \n2. The contractor shall submit test report from manufacturer of the LED fittings giving detail of each parameter /specifications of led luminaire mentioned in the BOQ item to comply with minimum requirements mentioned therein. \n3. The contractor shall also submit LM-79 & LM-80 test report from any valid NABL accreditation laboratory. 4. The contractor shall submit warranty certificate from manufacturer for minimum 2 years. 20 30 Each
21 21 Street light mounting bracket siutable for LED fitting upto 1.5RM made out of light grade GI pipe of size 50mm bore not less than 1.5 m length, bent to shape (120 degree) hot or cold for fixing / fitting at angular position complete with two Nos GI clamps with GI nuts, bolts and washers of suitable size and shape for fixing on pole/ wall complete all as specified and as directed. 21 40 Each
22 22 Non metallic Junction box made out of PVC size not less than 24cm x13cm x11cm hinged with lockable arrangement incl aluminium bus bar TPN capacity 200 amps ,with one no MCB SP 2.5 amps 10 KA 'C' Curve with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and as directed. 22 40 Each
23 23 Earthing complete with galvanized steel plate electrode 60cmx60cmx6mm surrounded by charcoal & salt buried directly in a pit of depth not less than 2.25m below ground level with top edge of the earth plate at a depth of not less than 1.50m below ground level, connected to and including GI wire 4mm dia as earthing lead upto 7.5m length by means of bolts, nuts, check nuts & washers of galvanized iron, earth wire protected by and including galvanized steel pipe 15mm bore (light grade) & connected to earth test point/ main control board/ panel including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore GI pipe (medium grade) for watering, funnel, wiremesh, PCC chamber in cement concrete (1:3:6) type C-1, CI cover and frame complete all as indicated in electric plate No 3 of SSR 2009 Part I including testing complete all as specified and as directed. 23 2 Each
24 24 Double wallled corrugated HDPE duct pipe of 40mm outer dia conforming to IS 14930 Pt II with antirodent and non flame propegating properties of approved colour complete with fitting for cable protection, supplied and laid in trenches or under floors or through culverts complete all as specified and as directed. 24 1600 RM
25 25 Supply, installation testing and commissioning of street light panel in replacement with Group Control management system using GPRS / GSM technology suitable for total load of 63 amps, including sensor for anti-tampering of panel, fibre glass in front for display of connection indicator & display MF meter, external locking arrangement sheet enclosure to be used should be CPRI approved CRCA sheet with angle iron frame 50 x 50 x 6 mm size legs , 04 nos legs 600 mm long, PCC 1:2:4 type B-1 for grouting of base, suitable for 3 phase 415 volts 50 Hz 4 wire AC supply and earthing. Note : Quoted rate shall be deemed to be inclusive of 2G/3G SIM charges & one year charges of the SIM for data, the complete information to be displayed with provision of user id through an SSL encrypted web application and SMS alerts to selected mobile numbers complete all as specified and directed. Cloud data service & web application service to be provided for minimum 5 years without any extra cost to the department. An agreement to this effect will have be submitted by the contractor from service provider. The GUI shall able to measure Voltage, Current, power Factor, Active power, Apparent power, metering cumulative active energy, metering cumulative apparent energy. Time scheduling which could be defined from the GUI running locally in smart device. GPRS communication between panel and cloud server and an option in panel for RF communication between panel and individual street lights for futuristic expansion. Wireless local control for field staff to on/off panel in case of GSM failure. The panel should be capable of sening following alerts :- (a) Phase wise over current /short circuit. 25 1 Each
26 25.01 Contd Srl No 25. (b) Phase wise over voltage (c) Group failure of lights. (d) No output supply (e) Tampering of door (f) Over voltage and under voltage protection for contactors and smart device (g) Low power factor detection (h) Under load and over load detection (j) GSM network down alert (k) RTC and NVM failure. (I) In built astronomical timer. (m) MCB tripping to be monitored on web application. The GUI should also support Google Maps overlay for live status monitoring of panel. Support for COAT (Configuration over the air) and FOTA (firmware over the air), Live instaneous load update, Total monthly /weekly/daily power consumption, on time and saving info, Configuration for user hierarchy from the GUI, Configuration for SMS and email for alert and reporting complete all as specified and directed with and including the following :- (a) MCCB TPN 63 amps capacity 16 KA 415 volts - 01 No (Incoming) with separate SPD of 40 kV capacity. \n(b) Resin cast CT's 100/5A - Set of 3. \n(c) Multi-function digital meter cIass 1 accuracy feeding information to GPRS controller. \n(d) GPRS controller module for dual communication with additional power back up upto 48 Hrs. \n(e) GIC digital timer to handle as specified .\n(f) Switch 6 Amps capacity with operation between Automatic mode/Manual mode/Timer mode/Off mode. \n 26
27 25.02 Contd Srl No 25. (g) Line contactor, AC 3 duty, 3 phase, 415 Volts, 50 Hz, 32 Amps-02 No, (h) MCB TPN 32 AmpS capacity - 02 (Outgoings) (j) Terminal block suitable for 100A rating with brass contacts for INPUT/OUTPUT termination \n(k) Anti tampering micro switch-01 No. \n(l) Control wiring & control MCB of 6 Amps and power wiring of toggle switch, indicators/ protection circuits, contactors, gateway/relay with 1.5 Sqmm multi strand copper cable (for control wiring) and of appropriate size for power wiring, including and ferrules- 01 Job as per circuit design complete all as specified and directed \n(m) Indicators for automation mode, timer mode, on mode, phase indicators, bypass mode to be provided such that they are visible from outside. 27
28 26 Supply and fix high power LED street light fittings energy saving luminaire with lens, with system wattage 90 watt with system efficacy (lm/w) not less than 100 lumens per watt, total system lumen not less than 9000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5700K +300K, high pressure die cast aluminium alloy LM6 housing heat shrink for better heat transmission with epoxy powder coated IP-65/66 class 1 protection, toughened glass/UV stabilized polycarbonate cover, well designed thermal management system , driver efficiency > 85% with constant output of current and voltage against input voltage variation 100 to 270 volt at 50 Hz ( + 5%), THD< 10%. The driver should be potted with electrolytic capacitor of min 105 degrees ratings and must be with phase protection, external SPD should be of minimun 10 KV capacity, complete all as directed. \n Notes:-\n1. Each luminaire should be printed on the luminaire fittings as "MES", CA No: GE(U)/CHM- 24/2020-21. \n2. The contractor shall submit test report from manufacturer of the LED fittings giving detail of each parameter /specifications of led luminaire mentioned in the BOQ item to comply with minimum requirements mentioned therein. \n3. The contractor shall also submit LM-79 & LM-80 test report from any valid NABL accreditation laboratory. 4. The contractor shall submit warranty certificate from manufacturer for minimum 2 years. 28 10 Each
29 27 Supply and fixing of 63 amp automatic street light switch using infrared sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of Natural light. Sensor alongwith suitable power contactors and incoming – outgoing MCB should be enclosed in MCB and supported terminal should be enclosed in pole/wall mountable enclosure made of Rust proof, electric shock proof, terminal proof and FR grade special moulding compound conforming to IP 66 protection class 2 enclosure made of thermoplastic polycarbonate and protected against weather influences all as specified and directed. : - (a) Three phase load of 5KW with 3 Nos Contactors, 3 Nos incoming MCBS & 3 Nos outgoing MCBs of 16-20 Amps each & circuit wiring (Copper) of min 10 Sqmm. 29 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail