Military Engineer Services-MES has published Special Repair To Old Vintage Poles , Ug Cables And Oh Lines At Various Locs At Morar Cantt Gwalior Under Ge Gwalior. Submission Date for this Tender is 26-10-2020. LT Cable Tenders in GWALIOR Madhya Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: SPECIAL REPAIR TO OLD VINTAGE POLES, UG CABLES AND OH LINES AT VARIOUS LOCS AT MORAR CANTT GWALIOR UNDER GE GWALIOR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling steel/PCC pole any size and removing from site complete all as specified and as directed. | 30 | Each | |
2 | 2 | Dismantling ACSR conductors and removing from site complete all as specified and as directed. | 10 | Qtl | |
3 | 3 | Dismantling of cross- arms, clamps, danger plate of MS channel or angle sections etc.and removing from site complete all as specified and as directed. | 10 | Qtl | |
4 | 4 | Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc complete all as specified and as directed. | 12 | Each set | |
5 | 5 | Dismantling insulators any type, any size complete all as specified and as directed. | 60 | Each | |
6 | 6 | Taking down unserviceable LT/HT UG cable of any size complete all as specified and as directed. | 2000 | RM | |
7 | 7 | Dismantling stay assembly complete, (demoliton of concrete, etc. and excavation measured separately) complete all as specified and as directed. | 10 | Per Set | |
8 | 8 | M&L, Steel tublar swaged poles, complete with cast iron base plate, finials taper plug , bolts, nuts & screws as specified type 410 SP-55 (11.00 mtr long). \nNote : Earth work and PCC shall be measured & paid separately under respective items complete all as specified and as directed.\nMake :- National tubing compan Ltd Kanpur/Quality steel products Ltd/India electric Poles/P.S Steel tube Pvt Ltd | 15 | Each | |
9 | 9 | M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) complete all as specified and as directed.\nMake :- National tubing compan Ltd Kanpur/Quality steel products Ltd/India electric Poles/P.S Steel tube Pvt Ltd | 15 | Each | |
10 | 10 | M&L, ACSR conductor of any size for HT over head lines on poles including stringing,tightening & binding to insulators with aluminium wire making connections, jumpers etc including testing, commisioning complete all as specified and directed. | 10 | Qtl | |
11 | 11 | M & L for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms and complete all as specified and as directed. | 10 | Qtl | |
12 | 12 | M & L for switch air break gang operated triple pole out door type with drop out switch fuse unit on HT 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on insulators (12 insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement complete all as specified and as directed.\nMake :- Jaipuria Brothers/HEI/Southern Switch gear/Pactil/Mull & Co. | 12 | Each set of 3 | |
13 | 13 | M & L for lightening arresters expulsion type 11 KV grade complete with all fittings, transmission class, discharge capacity 65 Kilo Amps complete all as specified and as directed. \nMake :- Oblum/Bhel/Atlas/Jaipuria Brothers/Pactil/Raychem | 12 | Set of three | |
14 | 14 | Supply, laying, jointing and testing, XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of size 3.5 core 150 Sqmm complete all as specified and as directed.\nMake :- Finolex/Gloster/Polycab/Plaza/KEI | 100 | RM | |
15 | 15 | All as per item No 14 but 120 Sqmm 3.5 core complete all as specified and as directed. | 150 | RM | |
16 | 16 | All as per item No 14 but 95 Sqmm 3.5 core complete all as specified and as directed. | 200 | RM | |
17 | 17 | All as per item No 14 but 70 Sqmm 3.5 core complete all as specified and as directed. | 200 | RM | |
18 | 18 | All as per item No 14 but 50 Sqmm 3.5 core complete all as specified and as directed. | 225 | RM | |
19 | 19 | All as per item No 14 but 35 Sqmm 3.5 core complete all as specified and as directed. | 250 | RM | |
20 | 20 | All as per item No 14 but 25 Sqmm 4 core complete all as specified and as directed. | 250 | RM | |
21 | 21 | All as per item No 14 but 16 Sqmm 4 core complete all as specified and as directed. | 300 | RM | |
22 | 22 | Supplying, laying, jointing & testing 95 sqmm 3 core XLPE insulated & PVC sheathed armoured earthed HT cable, 11000 volts grade heavy duty with aluminium conductor laid in trenches/pipe/fixed on the wall etc .complete all as specified and directed. Make: Finolex/Gloster/Polycab/Plaza/KEI | 500 | RM | |
23 | 23 | Supply and fixing cable jointing kit for 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sqmm complete all as specified and as directed.\nMake :- Raychem/Denson/CCI/Birla-3M | 2 | Each | |
24 | 24 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and as directed.\nMake :- Raychem/Denson/CCI/Birla-3M | 10 | Each | |
25 | 25 | M&L for tubing light grade GI of 100 mm dia for protection of cable complete all as specified and as directed.\nMake :- Tata/Swastik/Jindal/Prakash//Utkarsh | 18 | RM | |
26 | 26 | M&L for tubing light grade GI of 80mm dia for protection of cable complete all as specified and as directed.\nMake :- Tata/Swastik/Jindal/Prakash//Utkarsh | 12 | RM | |
27 | 27 | M&L for 40 mm bore GI tubing light grade for protection of cable complete all as specified and as directed.\nMake :- Tata/Swastik/Jindal/Prakash//Utkarsh | 12 | RM | |
28 | 28 | Restringing and stretching of existing sagged ACSR conductor of any size on OH electric line of any length on existing poles after disconnection of binding wires (dismantling & taking down) service connection etc and making, binding and service connection complete all as specified and as directed. | 10 | Qtl | |
29 | 29 | M & L for galvanised steel wire 4mm dia as in cradle guard including dismantling old unserviceable cradle guard complete all as directed and as directed. | 3 | Qtl | |
30 | 30 | M & L for Disc type insulators, porcelain, vitreous 145 mm height, 255 mm dia and socket type whit brown and green, 11000 volts grade, single disc assembly with tension clamps for conductors after dismantling unserviceable one complete all as specified and as directed.\nMake :- Bhel/Jayshree/Jaipuria/Rashtria/ABB/Pactil | 25 | Each | |
31 | 31 | M & L for pin type , porcelain, vitreous brown insulator of size 150mm height, 50mm dia 11000 volts grade including one galvanized mild steel spindle with two galvanized iron washers and one galvanized iron nut complete all as specified and as directed.\nMake :- Bhel/Jayshree/Jaipuria/Rashtria/ABB/Pactil | 50 | Each | |
32 | 32 | S & F loop type insulator vitreous porcelain white or brown with over all dimension 140 mm with 25.5 mm clearance hole complete all as specified and as directed.\nMake :- Bhel/Jayshree/Jaipuria/Rashtria/ABB/Pactil | 10 | Each | |
33 | 33 | M & L for stay assembly complete with accessories as shown in elect plate No-1 dia to stay 20mm dia 180mm long including MS galvanized stay plate of size 300mm x 300mm x 6mm thick and galvanized thimble after dismantling of unserviceable stay set (above GL) complete all as specified and as directed.\nNote:- Loop type insulator, excavation in earth work, PCC foundation shall be measured and paid separately under appropriate item) | 10 | Per set | |
34 | 34 | M&L for Galvanised Stay strand (Grade 2) size 7/3.15mm complete all as specified and as directed. | 1 | Per Qtl | |
35 | 35 | M & L for overhead line spacers/separators complete fixing with insulators as per sample complete incl taking own old unsv one complete all as specified and as directed. | 200 | Each | |
36 | 36 | S & F Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to GI strip of size 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part-I connecting to earthing point and testing on completion with and including 40 mm bore light grade G.I. protection pipe (0.5 metre beyond pit to main switch), PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as specified and as directed. | 10 | Each Set | |
37 | 37 | Supply and fixing in repairs of street light automatic nature switch of caacity 5 KW single phase with high and low voltage and overload protection, degree of protection confirm to IP-55 AC, SP with MCB and power contactor fixed on pole with 25 x 3mmm MS strip clamp including provisiion of 6 Sqmm 3 Core cable for connection complete all as specified and directed. \nMake : Kakatiya Energy system Model SWADEEP -02 EC 5 KW 1P or equivalent | 5 | Each | |
38 | 38 | Trimming of trees exc 30 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance of exc 50 m and clearing site complete all as specified and as directed. | 50 | Each | |
39 | 39 | M & L one coat of Aluminium paint after preparation of old surface of electric poles surfaces of any description steel, iron etc exc 10cm in width or girth including pole fittings such as cross arms of any description anti climbing devices nut bolts etc including numbering of poles complete all as specified and as directed. | 100 | Per Job | |
40 | 40 | M & L for one coat of synthetic enamel paint after preparation of on external surface of poles above copping up to 600mm alternate layer of black, red & black in sequence exceeding 10cm in width girth complete all as specified and as directed. | 100 | Per Pole | |
41 | 41 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. | 25 | RM | |
42 | 42 | Taking down old rusted/damaged LT panel board incl dismantling of PCC complete all as specified and as directed | 2 | Each | |
43 | 43 | Supply, installing in replacement, LT panel board 440 Volts, 4 wire, 3 phase factory fabricated powder coated, cubical, weather and vermin proof outdoor kiosk type, front opening, floor mounted made out of 3.15 mm thick CRCA sheet of size suitable for mounting the its accessories with electrolyte copper bus bar of capacity 300 Amp mounted on hygroscopic insulators and necessary electric connection of the equipment / accesories to be fixed, cable glands, lugs, mounted on steel angles supports of suitable size with grouting 4 Nos supports in PCC 1:2:4 type B1 complete with separate compartment for housing with proper arrangement for air circulation and including the following accessories all as specified and directed\n(a) Electrolytic Copper bus bar 300 Amps in distant colour with epoxy supported insulators - 01 Job.\n(b) MCCB 4 pole, 200 Amps, 415 Volts, rupturing capacity 25 KA - 01 No (incoming).\n(c) MCCB 4 pole, 160 Amps, 415 Volts, rupturing capacity 25 KA - 02 No (outgoing).\n(d) MCCB 4 Pole, 63 Amps, 415 volts, rupturing capacity 16 KA - 03 Nos for outgoing)\n(e) MCCB 4 Pole, 32 Amps, 415 volts, rupturing capacity 10 KA - 02 Nos for outgoing)\n(f) Volt meter analog type 0 to 500 volts with selector switch - 01 nos\n(g ) Ammeter analog type 0 to 400 Amps with CTs & selector switch - 01 Nos\n(h) Phase indication lamp LED type ( set of three ) - 01 set\n(j) Capacitor 40 kvAR (10x 2 & 5x4 KVAR ) - 01 Nos\n(k) Provisioning of cubicle as per approved drawing suitable for accomodating MCCBs and meter modules with selector switches, RYB indicators, etc.\nMake:- Uma Panel/ MC Layers Bhopal/National Engg Works/Universal switch gear/Shalabh//Alstone | 2 | Each Job | |
44 | 44 | S&F Danger notice plate of 1.6mm thick mild steel sheet, viterous enamelled white, with letters, figures and conventional skull and bones in single red color and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and as directed.. | 30 | Each | |
45 | 45 | HT cable route indicator precast made from PCC 1:3:6 of size 600mm x 230mm x 100 including excavation PCC for foundation and painting and writing as "11 kv cable" incl preparation of surfaces both sides complete all as specified and as directed. | 20 | Each | |
46 | 46 | Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed. | 413.1 | Cum | |
47 | 47 | Excavation in trenches exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed. | 4.9 | Cum | |
48 | 48 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed. | 261 | Cum | |
49 | 49 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. | 152.09 | Cum | |
50 | 50 | M&L for sand cushioning in trenches for cable protection including consolidation complete all as specified and as directed. | 127.17 | Cum | |
51 | 51 | M&L for Sub class 'B' bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified and as directed. | 12.56 | Per \n1000\n Nos | |
52 | 52 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. | 1.5 | Cum | |
53 | 53 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directe. | 16.2 | Cum | |
54 | 54 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded BT stone aggregate as in bed block for hold fast or coping including necessary form work complete all as specified and directed. | 1.62 | Cum |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy