Comprehensive Maintenance Of Modernized Water Supply System ( Scada ) Under Ge Dronachal, GE Dronachal-Madhya Pradesh

Military Engineer Services-MES has published Comprehensive Maintenance Of Modernized Water Supply System ( Scada ) Under Ge Dronachal. Submission Date for this Tender is 16-10-2020. Spare Part Tenders in GE Dronachal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25526605
Comprehensive Maintenance Of Modernized Water Supply System ( Scada ) Under Ge Dronachal
Open Tender
Indian
Madhya Pradesh
GE Dronachal
16-10-2020

Tender Details

Comprehensive Maintenance Of Modernized Water Supply System ( Scada ) Under Ge Dronachal , schedule a part-i ( scada works ) , operation and maintenance of scada based water supply system/management around the clock inclding sunday and holiday in three shift per day of 08 hours each ( 1st shift from 0600hrs to 1200hrs , 2nd shift from 1400hrs to 2200hrs and 3rd shift 2200hrs to 0600hrs ) by deplying experience and qualified skilled one pump operator in each shift for operation of scada as installed at dronachal base . the contractor will be responsible for repairing maintenance and servicing of all plc panels and all connected circuit/accessories required for motorised water supply system as described below :- ( a ) one trained technician iti qualified having three years experience in relevant field at scada room for attending monitoring the breakdown and preventative maintenance for plc panels and all connected circuits/ accessories in general shift ( upto 330 days ) and one company trained technician once in one month ( oem of plc panel ) and moterised valve for successful working system under ge dronachal . ( b ) servicing and maintenace /repair and replacement of defective components /spare parts with new one of the plc based control panels including all accessories modem , antenna etc . installed at various places , oht and master control station , mimic panel . , ( c ) repair/maintenance by disconnecting cleaning greasing for wear and tear complete servicing , refixing , lathing , installing and commissioning as directed by engr-in charge of all motorised and solenoid valve transmiter , ultrasonic and magnatic level sensor . ( d ) any changes to the programmable logic control ( plc ) in ladder logic of programme changes in operation timing ( limited to the scope of items covered under the contract ) . ( e ) any changes to scada software eg . change in report format , changes in operational screen , operation of soft keys etc . ( limited to the scope of items covered under the contract ) . ( f ) attending breakdown maintenance within three hours of reporting time and replacement of new one as reqd at site complete as specified and directed by engr-in-charge . ( g ) one helper to assist the operator shall be deployed by department/govt . for three shift around the clock including sunday/holiday . ( h ) the work shall be carried out by authorised representative of plc based company proof for the same shall be produced by contractor before commencement of work . , ( j ) the rate quoted by contractor for outsourcing shall not be less than minimum wage rate as noticed by govt . of india/state govt . /local body , whichever is higher . in case the rate quoted by the bidder are less than the prevelling minimum wages rate , the bid will be treated as non-bonafied/invalid and such bid/will not be considered for acceptance . in such case the lowest bidder shall be determined from amongst the valid/bonafied bids only . ( k ) the contractor shall quote the rates inclusive for cleaning of all installation/equipment/plants & mechinery for scada and to be kept in presentable condition at all time . he will be responsible for cutting of vegetation growth etc . by 6mtr radius from permisses of scada installation . ( l ) the contractor shall quote the rate inclusive of all the charges pertains to communication one number bsnl broadband connection with static ip at pump house and gprs enable data card use in all plc panel related to the scope of work . , rates required to be quoted for executing the work as described in srl no 1 . 10 , 1 . 20 & 1 . 30 here-in-before . , skilled workers wage per person as per existing rules , employees provident fund as mentioned in the tender documents , employees state insurance contribution as mentioned in the tender documents , contribution of bonus as mentioned in the tender documents , if applicable . , over head & profit on srl no 1 . 50 to 1 . 80 here-in-before . , gst as mentioned in the tender documents as per existng rules . , schedule a part-ii ( materials & labours ) , comprehensive maintenance for scada server system consisting of pc , printer , screen etc . as required at site including necessary updation suitable antivirus internet charges to upkeep the service for the entire period . , supply & fix single phase preventor model 1 : vsp d2 complete all as specified and directed . ( make : minilec or equivalent ) , supply & fix relay card single c/o 24 v dc complete all as specified and directed . ( make : leon/idec or equivalent ) , supply & fix relay card with base 4 c/o 240v ac complete all as specified and directed . ( make : leon/idec or equivalent ) , supply & fix led indicator colour/red /yellow/green/blue . ( make : esbee/teknic/tele meachnique or equivalent ) , supply & fix plc ( programmable logic controller ) complete all as specified and directed . ( make : mitushibishi , abb , siemens , pheonix contract , schneider ) , supply & fix i/o module for programmable logic controller . ( make : mitushibishi , pheonix contract , schneider or equivalent ) , supply & fix hmi ( homen machine interface ) for programmable logic controller . ( make : mitushibishi , abb , siemens , pheonix contract ) , supply & fix push button with led indicator - 240 v a . c . colour red /green complete all as specified and directed . ( make : esbee/siemens/teknic/tele meachnique or equivalent ) , supply & fix buzzer - 240 v a . ccomplete all as specified and directed . ( make : c&s , mimic or equivalent ) , supply & fix in repairs of flow switch alongwith all necessary parts as required at site . ( make : indfoss/ danfoss/switzer/rapid control ) , supply & fix of pressure switch ( make : indfoss/danfoss ) , supply & fix electric motor suitable for actuator of the following size complete all as specified and directed ( make : ritetork/universal switch gear co . or equivalent ) . , ( a ) 50/80 mm dia , ( b ) 100 mm dia , ( c ) 150 mm dia , ( d ) 200 mm dia , ( e ) 250 mm dia , supply & fix in repair for single phase moterised acuted butterfly valve for the following sizes ( make : audco/ virgo/l&t/hasel/hofner ) :- , ( a ) 50 mm dia , ( b ) 80 mm dia , ( c ) 100 mm dia , ( d ) 150 mm dia , ( e ) 200 mm dia , ( f ) 250 mm dia , supply & fix power capacitor for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix resistor for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix limit switch for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix smps input 230 v/ac , output 24v dc complete all as specified and directed . ( make : nhp/ telemehanique or equivalent ) , supply & fix ultrasonic level sensor range 0-5m make: banner ( make : banner or equivalent ) , supply & fix gprs modem complete all as specified and required at site . , supply & fix 9db antenna gprs modem complete all as specified and directed . , supply only ups battary for 12v 150 amp complete all as specified and directed . ( make : exide or eqivalent ) , supply & fix selector switch 2/3 pole suitable for auto/manual main power supply complete all as specified and directed . ( make : esbee/teknic/tele meachnique or equivalent ) , supply & fix 2kva inverter with sealed acid maintenance free battries for powering the panel upto the period minimum 06 hours . ( make : numeric/apc/tata/luminius ) , supply & fix mcb 3p 6a complete all as specified a

Key Value

Document Fees
INR 500 /-
EMD
INR 52400.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Comprehensive Maintenance of modernised water supply system (SCADA) under GE Dronachal.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCHEDULE 'A' PART-I (SCADA WORKS)
2 1.1 Operation and maintenance of SCADA based water supply system/management around the clock inclding Sunday and Holiday in three shift per day of 08 hours each (1st shift from 0600hrs to 1200hrs, 2nd shift from 1400hrs to 2200hrs and 3rd shift 2200hrs to 0600hrs) by deplying experience and qualified skilled one pump operator in each shift for operation of SCADA as installed at Dronachal Base. The contractor will be responsible for repairing maintenance and servicing of all PLC panels and all connected circuit/accessories required for motorised water supply system as described below :-\n(a) One trained technician ITI qualified having three years experience in relevant field at SCADA room for attending monitoring the breakdown and preventative maintenance for PLC panels and all connected circuits/ accessories in general shift (upto 330 days) and one company trained technician once in one month (OEM of PLC Panel) and moterised valve for successful working system under GE Dronachal.\n(b) Servicing and maintenace /repair and replacement of defective components /spare parts with new one of the PLC based control panels including all accessories modem, antenna etc. installed at various places, OHT and Master control station, Mimic panel. \n
3 1.2 (c) Repair/maintenance by disconnecting cleaning greasing for wear and tear complete servicing, refixing, lathing, installing and commissioning as directed by Engr-in Charge of all motorised and solenoid valve transmiter, Ultrasonic and magnatic level sensor.\n(d) Any changes to the programmable logic control (PLC) in ladder logic of programme changes in operation timing (limited to the scope of items covered under the contract).\n(e) Any changes to SCADA software eg. change in report format, changes in operational screen, operation of soft keys etc. (limited to the scope of items covered under the contract).\n(f) Attending breakdown maintenance within three hours of reporting time and replacement of new one as reqd at site complete as specified and directed by Engr-in-Charge.\n(g) One helper to assist the operator shall be deployed by Department/Govt. for three shift around the clock including Sunday/Holiday.\n(h) The work shall be carried out by authorised representative of PLC based company proof for the same shall be produced by contractor before commencement of work.
4 1.3 (j) The rate quoted by contractor for outsourcing shall not be less than minimum wage rate as noticed by Govt. of India/State Govt./local body, whichever is higher. In case the rate quoted by the bidder are less than the prevelling minimum wages rate, the bid will be treated as non-bonafied/invalid and such bid/will not be considered for acceptance. In such case the lowest bidder shall be determined from amongst the valid/bonafied bids only.\n(k) The contractor shall quote the rates inclusive for cleaning of all installation/equipment/plants & mechinery for SCADA and to be kept in presentable condition at all time. He will be responsible for cutting of vegetation growth etc. by 6mtr radius from permisses of SCADA installation.\n(l) The contractor shall quote the rate inclusive of all the charges pertains to communication one number BSNL Broadband connection with static IP at pump house and GPRS enable data card use in all PLC panel related to the scope of work.
5 1.4 Rates required to be quoted for executing the work as described in Srl No 1.10, 1.20 & 1.30 here-in-before.
6 1.5 Skilled worker's wage per person as per existing rules \n 990 Per Shift
7 1.6 Employees Provident Fund as mentioned in the tender documents 990 Per Shift
8 1.7 Employees State Insurance Contribution as mentioned in the tender documents\n 990 Per Shift
9 1.8 Contribution of Bonus as mentioned in the tender documents, if applicable.\n 990 Per Shift
10 1.9 Over head & Profit on srl No 1.50 to 1.80 here-in-before. 990 Per Shift
11 2 GST as mentioned in the tender documents as per existng rules. 990 Per Shift
12 3 SCHEDULE 'A' PART-II (MATERIALS & LABOURS)
13 3.1 Comprehensive maintenance for SCADA server system consisting of PC, printer, screen etc. as required at site including necessary updation suitable antivirus internet charges to upkeep the service for the entire period. 1 Job
14 4 Supply & Fix single phase Preventor Model 1 : VSP D2 complete all as specified and directed. (Make : MINILEC or equivalent)\n 6 Each
15 5 Supply & Fix Relay card single C/O 24 V DC complete all as specified and directed. (Make : LEON/IDEC or Equivalent) 60 Each
16 6 Supply & Fix Relay card with base 4 C/O 240V AC complete all as specified and directed.(Make : LEON/IDEC or Equivalent) 60 Each
17 7 Supply & Fix LED Indicator Colour/Red /yellow/Green/Blue. (Make : ESBEE/TEKNIC/TELE MEACHNIQUE or equivalent) 40 Each
18 8 Supply & Fix PLC (Programmable Logic Controller) complete all as specified and directed. (Make : MITUSHIBISHI, ABB, SIEMENS, PHEONIX CONTRACT, SCHNEIDER)\n 2 Each
19 9 Supply & Fix I/O module for Programmable Logic Controller. (Make : MITUSHIBISHI, PHEONIX CONTRACT, SCHNEIDER or equivalent)\n 4 Each
20 10 Supply & Fix HMI (Homen Machine Interface) for Programmable Logic Controller. (Make : MITUSHIBISHI, ABB, SIEMENS, PHEONIX CONTRACT)\n 2 Each
21 11 Supply & Fix push button with LED Indicator - 240 V A.C. Colour Red /Green complete all as specified and directed. (Make : ESBEE/SIEMENS/TEKNIC/TELE MEACHNIQUE or equivalent) 8 Each
22 12 Supply & Fix Buzzer - 240 V A.Ccomplete all as specified and directed. (MAKE : C&S, MIMIC or equivalent) 4 Each
23 13 Supply & Fix in repairs of Flow switch alongwith all necessary parts as required at site. (Make : INDFOSS/ DANFOSS/SWITZER/RAPID CONTROL) 1 Each
24 14 Supply & Fix of Pressure switch\n(Make : INDFOSS/DANFOSS) 2 Each
25 15 Supply & Fix Electric motor suitable for actuator of the following size complete all as specified and directed (Make : RITETORK/UNIVERSAL SWITCH GEAR CO. or equivalent). \n
26 15.1 (a) 50/80 mm dia 3 Each
27 15.2 (b) 100 mm dia 3 Each
28 15.3 (c) 150 mm dia 8 Each
29 15.4 (d) 200 mm dia 4 Each
30 15.5 (e) 250 mm dia 3 Each
31 16 Supply & Fix in repair for single phase moterised acuted butterfly valve for the following sizes (Make : AUDCO/ VIRGO/L&T/HASEL/HOFNER) :- \n
32 16.1 (a) 50 mm dia 2 Each
33 16.2 (b) 80 mm dia 3 Each
34 16.3 (c) 100 mm dia 2 Each
35 16.4 (d) 150 mm dia 8 Each
36 16.5 (e) 200 mm dia 3 Each
37 16.6 (f) 250 mm dia 3 Each
38 17 Supply & Fix Power Capacitor for Actuator suitable for 50/80/100/150 mm dia Motorized Butterfly Valve complete all as specified and directed. (Make : UNIVERSAL SWITCHGEAR CO. or equivalent) 5 Each
39 18 Supply & Fix Resistor for Actuator suitable for 50/80/100/150 mm dia motorized Butterfly Valve complete all as specified and directed. (Make : UNIVERSAL SWITCHGEAR CO. or equivalent) 5 Each
40 19 Supply & Fix Limit switch for Actuator suitable for 50/80/100/150 mm dia motorized Butterfly Valve complete all as specified and directed.(Make : UNIVERSAL SWITCHGEAR CO. or equivalent) 10 Each
41 20 Supply & Fix SMPS input 230 V/AC, Output 24V DC complete all as specified and directed. (Make : NHP/ TELEMEHANIQUE or equivalent) 1 Each
42 21 Supply & Fix Ultrasonic Level Sensor range 0-5M Make: Banner (Make : BANNER or equivalent) 1 Each
43 22 Supply & Fix GPRS Modem complete all as specified and required at site. 1 Each
44 23 Supply & Fix 9DB Antenna GPRS Modem complete all as specified and directed. 2 Each
45 24 Supply only UPS Battary for 12V 150 Amp complete all as specified and directed. (Make : EXIDE or eqivalent) 1 Each
46 25 Supply & Fix Selector switch 2/3 pole suitable for auto/manual main power supply complete all as specified and directed. (Make : ESBEE/TEKNIC/TELE MEACHNIQUE or equivalent) 1 Each
47 26 Supply & Fix 2KVA inverter with sealed acid maintenance free battries for powering the panel upto the period minimum 06 hours. (Make : NUMERIC/APC/TATA/LUMINIUS) 3 Each
48 27 Supply & Fix MCB 3P 6A complete all as specified and directed. 2 Each
49 28 Supply & Fix coil for solenoid valve 10mm dia 230 Volt AC brass or stainless steel body with suitable pressure of coil power 6 Watt. 3 Each
50 29 Ditto as per item No 28 above but for 25 mm dia. 3 Each
51 30 Supply & Fix motorized ball valve 25 mm complete all as specified and directed. (Make : UNIVERSAL SWITCHGEAR or equivalent) 3 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail