External Repairs , Rehabilitation And Painting Of Civil Structures Of Php Building , At Rcf Thal . , RCF LTD THAL-Maharashtra

Rashtriya Chemicals And Fertilizers Limited-RCF has published External Repairs , Rehabilitation And Painting Of Civil Structures Of Php Building , At Rcf Thal . . Submission Date for this Tender is 03-10-2020. Coats and Jackets Tenders in RCF LTD THAL Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

25484273
External Repairs , Rehabilitation And Painting Of Civil Structures Of Php Building , At Rcf Thal .
Open Tender
Indian
Maharashtra
RCF LTD THAL
03-10-2020

Tender Details

External Repairs , Rehabilitation And Painting Of Civil Structures Of Php Building , At Rcf Thal . , Item Description , Exposing Existing Rcc Columns , Beams , Slabs , Chajjas , R . C . C . Fins , Lintels , Pardis Etc . Including Plaster Upto 6Mm Beyond Main Reinforcement Carefully By Means Of Chisel And Hammer Or Mechanically Including Necessary Double Scaffolding , Erecting Platforms At Working Levels To Collect The Debris As Directed Stacking The Debris In The Compound As Directed And Carting Away The Same Upto Dumping Yard Within The Premises Etc . Complete , Removing Existing Corrosion Manually/ Mechanically In M . S . /Tor Bars By Means Of Suitable Light Taping , Wire Brushing Mechanical Grinder , Washing And Drying Exposed Surfaces , Providing And Applying 2 Coats Of Approved Rust Passivator To Exposed Bar , Scrapping Reinforcing Bars Again And Applying `Polyalk Fixoprime Or Other Approved Brand Including Scaffolding Etc . Complete ( Measurement Shall Be Given For Exposed Area Of Concrete ) . , Repairing Of Damaged Rcc Members Like Columns , Slabs , Chajjas , Fins , Lintels , Pardis , Beams By Polymer Modified Mortar Including Applying Bonding Coat Of Polyalk Ep Or Equivalent Brand In Required Proportion ( As Per Manufacturers Recommendations ) In Layers For Built Up Thickness Of 15Mm To 25Mm . The Rates Shall Be Inclusive Of Necessary Scaffolding , Mixing Polymer Mortar In Mixers , Compacting Mortars By Hand Held Vibrators , Curing Etc . Complete . ( Use Pmm: Cement: Kharsaliya Sand In 1:5:15 Proportion ) , Dismantling Of Damaged Internal/External Cement Plaster Over Concrete & Masonry Work With All Leads , Lifts Including Necessary Scaffolding Without Causing Inconvenience To The Plant Operations & Disposal Of Debris With In The Factory Premises As Directed By Eic . , Providing Internal Cement Plaster 20Mm Thick In A Two Coat , In Cement Mortar Using Kharsaliya Sand 1:4 Without Neeru Finish To Concrete Or Brick Surface In All Position Including Racking Out Joints , Scaffolding And Curing Etc . Complete . , Providing External Sand Faced Cement Plaster In Cement Sand Mortar Using Kharsaliya Sand ( 1:4 ) In Two Layers Including Providing Base Coat Of 15 Mm Thick Mixing Approved Water Proofing Compound To The First Coat Of Plaster And Keeping Base Coat Rough To Receive Sand Faced Treatment Of 8 Mm Thick Including Scaffolding , Curing Etc . Complete . , Providing And Applying Polymer Modified Ready Mix Cement Micro Concrete Of Any Thickness Beyond 30 Mm As Per Site Requirement Of Approved Brand Including Curing Etc . As Per Manufacturers Specifications Or As Per Instructions Of Engineer In-Charge ( The Items Shall Be Paid On Actual Consumption Of Ready Mix Quantity Only ) . Bond Coat Etc . As Directed By Eic And Including Necessary M . S . Pipe Scaffolding . , Providing And Constructing Second Class Burnt Brick Masonry In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Including Striking Joints , Watreing , Scaffolding Etc . In Superstructure & Foundation At All Heights Etc . Complete . , Providing And Applying Waterproof Cement Paint Of Approved Colour , Shade And Quality To Old/New Plastered Internal Surface At All Heights In Two Coats Over One Coat Of Primer Including Water Washing , Cleaning , Preparing The Surfaces & Curing And Including Necessary Scaffolding As Directed By Eic . , Providing And Applying Waterproof Cement Paint Of Approved Colour , Shade And Quality To Old/New Plastered External/ Internal Surface At All Heights In Two Coats Over One Coat Of Primer Including Water Washing , Cleaning , Preparing The Surfaces & Curing And Including Necessary Scaffolding As Directed By Eic . ( Item May Vary As Per The Sutaibility And As Directed By Eic ) , Providing And Applying Semi Acrylic Exterior Emulsion Paint Of Approved Make And Shade ( Ace Of Asian Paint / Walmasta Of Berger Paint / Suraksha Plus Nerolac Paint Or Equivalent ) In Two Or More Coats Over One Coat Of Compatible Primer Including Scrapping , Cleaning , Washing And M . S . Pipe Scaffolding Etc . Complete As Directed By Eic . ( Item May Vary As Per The Sutaibility And As Directed By Eic ) , Providing And Applying 100% Acrylic Exterior Emulsion Paint Of Approved Make And Shade ( Apex Of Asian Paint / Weather Coat Of Berger Paint / Excel Of Nerolac Paint Or Equivalent ) In Two Or More Coats Over One Coat Of Compatible Primer Including Scrapping , Cleaning , Washing And M . S . Pipe Scaffolding Etc . Complete As Directed By Eic . ( Itemmay Vary As Per The Sutaibility And As Directed By Eic ) , Dismantling Carefully The Existing/ Damaged Structure Of Brick/Block/Stone Masonry In Cement Or Lime Mortar With All Leads & Lifts , Including Sorting Out Serviceable Materials And Stacking The Dismantled Material Neatly Including Necessary Scaffolding & Disposal Of Debris Up To 50 M Lead With In The Factory Premises As Directed By Eic . , Providing Fixing Cement Grill As Per Existing Pattern Using Cement Concrete M-25 With Nominal Sttel Reinforcement Including Dismantling Carefully The Existing/ Damaged Window Grill Structure With All Leads & Lifts , Including Sorting Out Serviceable Materials And Stacking The Dismantled Material Neatly Including Necessary Scaffolding & Disposal Of Debris Up To 50 M Lead With In The Factory Premises As Directed By Eic . , Providing Fixing New Window Frame Gi Coated Structural Steel Work In Rolled Sections Joists , Channels , Angles , Tees , Plates , Purlins , Rafters , Bottom Bracings And Nut-Bolts . As Per Detailed Design And Drawings Or As Directed By Eic , With Gi Coating With Hot Dipped Galvanized Coating Of 86 Micron , Including M . S . Pipe Scaffolding , Cutting , Fabricating , Hoisting , Erecting , Fixing In Position Making Riveted / Bolted / Welded Connections With Connecting Plates , Braces Etc . Complete . ( Of Make Tata/Sail/Rinl/Jsw Or Equivalent As Approved By Eic ) , Providing Fixing Frp ( Fibre- Reinforced Plastic ) Sheets 4Mm Thickness For Window Lowers Of Minimum Width 200Mm Including All Tools , Tackles And Fixtures And Fasteners Fixing In Position Making Riveted/Bolted Connections With Connecting Frame , Braces Etc , M . S . Pipe Scaffolding Etc As Directed By Eic Complete , Providing Fixing Frp ( Fibre- Reinforced Plastic ) Sheets 4Mm Thickness For Window Lowers Of Minimum Width 150Mm Including All Tools , Tackles And Fixtures And Fasteners Fixing In Position Making Riveted/Bolted Connections With Connecting Frame , Braces Etc , M . S . Pipe Scaffolding Etc As Directed By Eic Complete , Providing Making Arrangement Including All Tools And Tackels With Steam / Hot Water For Cleaning The Surface In Two Reperations Of Plaster / Brick Work / Concrete With Specialized Water Steamer Techniques , Followed Up By Gentle Brushing With Soft Nylon Brushes And For Removal Of Urea From Plaster / Brick Work / Concrete Ingress Into The Surface Also Removing Dirt , Dust , Grease , Oil , Algae , Fungus Etc Inclusive Of All Equipment , Materials , Labours , Scaffolding Etc As Directed By Eic Complete , Providing & Making Cement Vatta Along The Junction Of Wall And Sheet Of 300Mm Width For Restricting The Ingress Of Water Through Joints With Min 75 Mm Average With Base Layer Of Birck Bat Cement Mortor 1:3 Including Approved Water Proofing Compound Of Min . 1Kg Per Cement Bag Or As Per Manufacturers Specifications And Finish Cement Plaster Layer Of 12 Mm With Cement Mortor / Plaster 1:3 Including Approved Water Proofing Compound Of Min . 1Kg Per Cement Bag Or As Per Manufacturers Specifications And Neat Cement Finish And Curing Etc Complete As Specified And Directed By Eic . , Removing Of Roofing Sheets From Perifial Shed Of Transfer Towers For Approaching The Site Using Scaffolding For Repairing And Painting Work And Refixing The Same Sheets Along With Hooks Aft

Key Value

Document Fees
Refer document
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: EXTERNAL REPAIRS, REHABILITATION AND PAINTING OF CIVIL STRUCTURES OF PHP BUILDING AT RCF THAL.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Item Description
2 1.01 EXPOSING EXISTING RCC COLUMNS, BEAMS, SLABS, CHAJJAS, R.C.C. FINS, LINTELS, PARDIS ETC. INCLUDING PLASTER UPTO 6MM BEYOND MAIN REINFORCEMENT CAREFULLY BY MEANS OF CHISEL AND HAMMER OR MECHANICALLY INCLUDING NECESSARY DOUBLE SCAFFOLDING, ERECTING PLATFORMS AT WORKING LEVELS TO COLLECT THE DEBRIS AS DIRECTED STACKING THE DEBRIS IN THE COMPOUND AS DIRECTED AND CARTING AWAY THE SAME UPTO DUMPING YARD WITHIN THE PREMISES ETC. COMPLETE 2500 SQM
3 1.02 REMOVING EXISTING CORROSION MANUALLY/ MECHANICALLY IN M.S./TOR BARS BY MEANS OF SUITABLE LIGHT TAPING, WIRE BRUSHING MECHANICAL GRINDER, WASHING AND DRYING EXPOSED SURFACES, PROVIDING AND APPLYING 2 COATS OF APPROVED RUST PASSIVATOR TO EXPOSED BAR, SCRAPPING REINFORCING BARS AGAIN AND APPLYING `POLYALK FIXOPRIME" OR OTHER APPROVED BRAND INCLUDING SCAFFOLDING ETC. COMPLETE (MEASUREMENT SHALL BE GIVEN FOR EXPOSED AREA OF CONCRETE). 2500 SQM
4 1.03 REPAIRING OF DAMAGED RCC MEMBERS LIKE COLUMNS, SLABS, CHAJJAS, FINS, LINTELS, PARDIS, BEAMS BY "POLYMER MODIFIED MORTAR" INCLUDING APPLYING BONDING COAT OF "POLYALK EP OR EQUIVALENT BRAND IN REQUIRED PROPORTION (AS PER MANUFACTURER'S RECOMMENDATIONS) IN LAYERS FOR BUILT UP THICKNESS OF 15MM TO 25MM. THE RATES SHALL BE INCLUSIVE OF NECESSARY SCAFFOLDING, MIXING POLYMER MORTAR IN MIXERS, COMPACTING MORTARS BY HAND HELD VIBRATORS, CURING ETC. COMPLETE. (USE PMM: CEMENT: KHARSALIYA SAND IN 1:5:15 PROPORTION) 2500 SQM
5 1.04 DISMANTLING OF DAMAGED INTERNAL/EXTERNAL CEMENT PLASTER OVER CONCRETE & MASONRY WORK WITH ALL LEADS, LIFTS INCLUDING NECESSARY SCAFFOLDING WITHOUT CAUSING INCONVENIENCE TO THE PLANT OPERATIONS & DISPOSAL OF DEBRIS WITH IN THE FACTORY PREMISES AS DIRECTED BY EIC. 4500 SQM
6 1.05 PROVIDING INTERNAL CEMENT PLASTER 20MM THICK IN A TWO COAT, IN CEMENT MORTAR USING KHARSALIYA SAND 1:4 WITHOUT NEERU FINISH TO CONCRETE OR BRICK SURFACE IN ALL POSITION INCLUDING RACKING OUT JOINTS, SCAFFOLDING AND CURING ETC. COMPLETE. 1500 SQM
7 1.06 PROVIDING EXTERNAL SAND FACED CEMENT PLASTER IN CEMENT SAND MORTAR USING KHARSALIYA SAND (1:4) IN TWO LAYERS INCLUDING PROVIDING BASE COAT OF 15 MM THICK MIXING APPROVED WATER PROOFING COMPOUND TO THE FIRST COAT OF PLASTER AND KEEPING BASE COAT ROUGH TO RECEIVE SAND FACED TREATMENT OF 8 MM THICK INCLUDING SCAFFOLDING,CURING ETC. COMPLETE. 3000 SQM
8 1.07 PROVIDING AND APPLYING POLYMER MODIFIED READY MIX CEMENT MICRO CONCRETE OF ANY THICKNESS BEYOND 30 MM AS PER SITE REQUIREMENT OF APPROVED BRAND INCLUDING CURING ETC. AS PER MANUFACTURER'S SPECIFICATIONS OR AS PER INSTRUCTIONS OF ENGINEER IN-CHARGE (THE ITEMS SHALL BE PAID ON ACTUAL CONSUMPTION OF READY MIX QUANTITY ONLY). BOND COAT ETC. AS DIRECTED BY EIC AND INCLUDING NECESSARY M.S. PIPE SCAFFOLDING. 3 M.T.
9 1.08 PROVIDING AND CONSTRUCTING SECOND CLASS BURNT BRICK MASONRY IN CEMENT MORTAR 1:6 (1 CEMENT : 6 COARSE SAND) INCLUDING STRIKING JOINTS, WATREING, SCAFFOLDING ETC.IN SUPERSTRUCTURE & FOUNDATION AT ALL HEIGHTS ETC. COMPLETE. 100 Cu.M
10 1.09 PROVIDING AND APPLYING WATERPROOF CEMENT PAINT OF APPROVED COLOUR, SHADE AND QUALITY TO OLD/NEW PLASTERED INTERNAL SURFACE AT ALL HEIGHTS IN TWO COATS OVER ONE COAT OF PRIMER INCLUDING WATER WASHING, CLEANING, PREPARING THE SURFACES & CURING AND INCLUDING NECESSARY SCAFFOLDING AS DIRECTED BY EIC. 1650 SQM
11 1.1 PROVIDING AND APPLYING WATERPROOF CEMENT PAINT OF APPROVED COLOUR, SHADE AND QUALITY TO OLD/NEW PLASTERED EXTERNAL/ INTERNAL SURFACE AT ALL HEIGHTS IN TWO COATS OVER ONE COAT OF PRIMER INCLUDING WATER WASHING, CLEANING, PREPARING THE SURFACES & CURING AND INCLUDING NECESSARY SCAFFOLDING AS DIRECTED BY EIC. (ITEM MAY VARY AS PER THE SUTAIBILITY AND AS DIRECTED BY EIC) 7000 SQM
12 1.11 PROVIDING AND APPLYING SEMI ACRYLIC EXTERIOR EMULSION PAINT OF APPROVED MAKE AND SHADE (ACE OF ASIAN PAINT / WALMASTA OF BERGER PAINT / SURAKSHA PLUS NEROLAC PAINT OR EQUIVALENT) IN TWO OR MORE COATS OVER ONE COAT OF COMPATIBLE PRIMER INCLUDING SCRAPPING, CLEANING, WASHING AND M.S. PIPE SCAFFOLDING ETC. COMPLETE AS DIRECTED BY EIC. (ITEM MAY VARY AS PER THE SUTAIBILITY AND AS DIRECTED BY EIC) 7000 SQM
13 1.12 PROVIDING AND APPLYING 100% ACRYLIC EXTERIOR EMULSION PAINT OF APPROVED MAKE AND SHADE ( APEX OF ASIAN PAINT / WEATHER COAT OF BERGER PAINT / EXCEL OF NEROLAC PAINT OR EQUIVALENT) IN TWO OR MORE COATS OVER ONE COAT OF COMPATIBLE PRIMER INCLUDING SCRAPPING, CLEANING, WASHING AND M.S. PIPE SCAFFOLDING ETC. COMPLETE AS DIRECTED BY EIC. (ITEMMAY VARY AS PER THE SUTAIBILITY AND AS DIRECTED BY EIC) 12000 SQM
14 1.13 DISMANTLING CAREFULLY THE EXISTING/ DAMAGED STRUCTURE OF BRICK/BLOCK/STONE MASONRY IN CEMENT OR LIME MORTAR WITH ALL LEADS & LIFTS, INCLUDING SORTING OUT SERVICEABLE MATERIALS AND STACKING THE DISMANTLED MATERIAL NEATLY INCLUDING NECESSARY SCAFFOLDING & DISPOSAL OF DEBRIS UP TO 50 M LEAD WITH IN THE FACTORY PREMISES AS DIRECTED BY EIC. 100 Cu.M
15 1.14 PROVIDING FIXING CEMENT GRILL AS PER EXISTING PATTERN USING CEMENT CONCRETE M-25 WITH NOMINAL STTEL REINFORCEMENT INCLUDING DISMANTLING CAREFULLY THE EXISTING/ DAMAGED WINDOW GRILL STRUCTURE WITH ALL LEADS & LIFTS, INCLUDING SORTING OUT SERVICEABLE MATERIALS AND STACKING THE DISMANTLED MATERIAL NEATLY INCLUDING NECESSARY SCAFFOLDING & DISPOSAL OF DEBRIS UP TO 50 M LEAD WITH IN THE FACTORY PREMISES AS DIRECTED BY EIC. 400 SQM
16 1.15 PROVIDING FIXING NEW WINDOW FRAME GI COATED STRUCTURAL STEEL WORK IN ROLLED SECTIONS JOISTS, CHANNELS, ANGLES, TEES, PLATES, PURLINS, RAFTERS, BOTTOM BRACINGS AND NUT-BOLTS. AS PER DETAILED DESIGN AND DRAWINGS OR AS DIRECTED BY EIC, WITH GI COATING WITH HOT DIPPED GALVANIZED COATING OF 86 MICRON, INCLUDING M.S. PIPE SCAFFOLDING, CUTTING, FABRICATING, HOISTING, ERECTING, FIXING IN POSITION MAKING RIVETED / BOLTED / WELDED CONNECTIONS WITH CONNECTING PLATES, BRACES ETC. COMPLETE. (OF MAKE TATA/SAIL/RINL/JSW OR EQUIVALENT AS APPROVED BY EIC) 6 MT
17 1.16 PROVIDING FIXING FRP (FIBRE- REINFORCED PLASTIC) SHEETS 4MM THICKNESS FOR WINDOW LOWERS OF MINIMUM WIDTH 200MM INCLUDING ALL TOOLS, TACKLES AND FIXTURES AND FASTENERS FIXING IN POSITION MAKING RIVETED/BOLTED CONNECTIONS WITH CONNECTING FRAME, BRACES ETC, M.S. PIPE SCAFFOLDING ETC AS DIRECTED BY EIC COMPLETE 1920 RMT
18 1.17 PROVIDING FIXING FRP (FIBRE- REINFORCED PLASTIC) SHEETS 4MM THICKNESS FOR WINDOW LOWERS OF MINIMUM WIDTH 150MM INCLUDING ALL TOOLS, TACKLES AND FIXTURES AND FASTENERS FIXING IN POSITION MAKING RIVETED/BOLTED CONNECTIONS WITH CONNECTING FRAME, BRACES ETC, M.S. PIPE SCAFFOLDING ETC AS DIRECTED BY EIC COMPLETE 580 RMT
19 1.18 PROVIDING MAKING ARRANGEMENT INCLUDING ALL TOOLS AND TACKELS WITH STEAM / HOT WATER FOR CLEANING THE SURFACE IN TWO REPERATIONS OF PLASTER / BRICK WORK / CONCRETE WITH SPECIALIZED WATER STEAMER TECHNIQUES, FOLLOWED UP BY GENTLE BRUSHING WITH SOFT NYLON BRUSHES AND FOR REMOVAL OF UREA FROM PLASTER / BRICK WORK / CONCRETE INGRESS INTO THE SURFACE ALSO REMOVING DIRT, DUST, GREASE, OIL, ALGAE, FUNGUS ETC INCLUSIVE OF ALL EQUIPMENT, MATERIALS, LABOURS, SCAFFOLDING ETC AS DIRECTED BY EIC COMPLETE 7000 SQM
20 1.19 PROVIDING & MAKING CEMENT VATTA ALONG THE JUNCTION OF WALL AND SHEET OF 300MM WIDTH FOR RESTRICTING THE INGRESS OF WATER THROUGH JOINTS WITH MIN 75 MM AVERAGE WITH BASE LAYER OF BIRCK BAT CEMENT MORTOR 1:3 INCLUDING APPROVED WATER PROOFING COMPOUND OF MIN. 1KG PER CEMENT BAG OR AS PER MANUFACTURERS SPECIFICATIONS AND FINISH CEMENT PLASTER LAYER OF 12 MM WITH CEMENT MORTOR / PLASTER 1:3 INCLUDING APPROVED WATER PROOFING COMPOUND OF MIN. 1KG PER CEMENT BAG OR AS PER MANUFACTURERS SPECIFICATIONS AND NEAT CEMENT FINISH AND CURING ETC COMPLETE AS SPECIFIED AND DIRECTED BY EIC. 370 SQM
21 1.2 REMOVING OF ROOFING SHEETS FROM PERIFIAL SHED OF TRANSFER TOWERS FOR APPROACHING THE SITE USING SCAFFOLDING FOR REPAIRING AND PAINTING WORK AND REFIXING THE SAME SHEETS ALONG WITH HOOKS AFTER COMPLETION OF REPAIRING , PAINTING JOB 1344 SQM
22 1.21 APPLICATION OF CORROSION INHIBITOR: PROVIDING & APPLYING ONE COAT OFCONCRETE PENETRATING CORROSION INHIBITOR (SURFACE APPLIED) WHICH WORKS ON BIPOLAR INHIBITION MECHANISM ON ENTIRE CONCRETE SURFACE TO BE REPAIRED BY USING BRUSH OR SPRAY SPECIFICATION AND PRIOR TO APPLICATION OF FIRST COAT OF ANTI-CORROSIVE COATING TO REINFORCEMENT. 1400 SQM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail