Work In Deposit Scheme In The Area Of Edsd-Majhola Under Edd-1 Moradabad, MORADABAD-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Work In Deposit Scheme In The Area Of Edsd-Majhola Under Edd-1 Moradabad. Submission Date for this Tender is 28-09-2020. Nuts Supply Tenders in MORADABAD Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25437096
Work In Deposit Scheme In The Area Of Edsd-Majhola Under Edd-1 Moradabad
Open Tender
Indian
Uttar Pradesh
MORADABAD
28-09-2020

Tender Details

Work In Deposit Scheme In The Area Of Edsd-Majhola Under Edd-1 Moradabad-1 Safe Carriage Of The Following Material From Store Centre Majhola / Jes Store To Work Site Including Loading And Unloading At Both Ends :- 2 13 Mtr. / 11 Mtr. / 9 Mtr. / 8.5 Mtr. Long Pcc / St Poles. 3 Acsr Weasel / Dog Conductor. 4 11 / 0.4 10 Kva Transformers. 5 11 / 0.4 25 Kva Transformers. 6 11 / 0.4 63 Kva Transformers. 7 11 / 0.4 100 Kva Transformers. 8 Lt A.B.C. Cable. 9 11 Kv Xlpe Cable Of Size 3X70 Sq.Mm. / 3X120 Sq.Mm. / 3X180 Sq.Mm. Etc. 10 Line Material Such As Cross-Arms, Pin Insulators, Guarding Angles, Guarding Wire, Disc Insulators And Cable Jointing Kits Etc. 11 Ct / Pt Unit 12 11 Kv Pilfer Proof Metering Cubical. 13 Dismantling Of The Line By :- 14 Removing Of Acsr Weasel / Dog Conductor From All Phases On Line, Making Bundle And Stacking At A Safe Place. 15 Uprooting Of 13 Mtr. / 11 Mtr. / 9 Mtr. / 8.5 Mtr. Long Pcc / St Poles. 16 For 11 Kv Line, Single Support 13 / 11 / 9 / 8.5 Mtr. Long St / Pcc Poles :- Excavation Of Foundation Pit In Size Of 75X45 Cm. Having Depth Of 1 / 6Th Of The Full Length Of The Support ( Pole ) , Providing And Laying Of Stone Pad ( 300X300x75mm. ) In The Bottom Of The Pit. Erection Of Support ( Pole ) Complete With Fixing Of 11 Kv V-Type Cross-Arms And All Other Accessories By Providing Stone Pad, Cross Arms, Holding Clamps, F-Bracket And Nuts & Bolts Etc. As Per Respo Norms. 17 For 11 Kv Line, Double Pole Structure With 13 / 11 / 9 / 8.5 Mtr. Long St / Pcc Poles :- Excavation Of Foundation Pit In Size Of 75X45 Cm. Having Depth Of 1 / 6Th Of The Full Length Of The Support ( Pole ) . Erection Of Support ( Pole ) Complete Work By Fixing Of D.P. Clamps And All Other Accessories. The Work Includes Fabrication Work And Fixing Of Cross Bracing Sets, Cutting Holes Complete Work As Per Respo Norms. 18 Construction Of Tri-Pole Structure On St Poles Including Fabrication Of Ms Angle Channel, Cross Bracing Etc. With Proving And Fitting Of All Type Of Clamps Made Of Ms Flat Of Size 65X8mm. With Nuts, Bolts & Washer, Grouting Of Pole In Size Of 220X45x45 Cm. With Cement, Sand And Brick Ballast In The Ratio Of 1:4:8, As Per Respo Norms. 19 Grouting Of Poles Single Line Support :- Grouting Of Support In Cc 1:4:6 ( Cement, Sand And 40 Mm. Brick Ballast ) Grouting Will Be Done In The Block Of Size 45Cm X 45Cm X 1 / 6Th Of Full Length Of The Support Upto Ground Level As Per Respo Norms. 20 Grouting Of Stay Rods ( 20X1800mm. ) Including All Works Of Excavation, Cement Concrete In Size Of ( 0.60X0.60X0.30 ) M In The Ratio Of 1:4:6 ( Cement, Sand And 40 Mm. Brick Ballast ) Including Back Filling Of Soil And Proper Ramming Etc. 21 Fixing, Tightening And Nozelling Of Stay Wire With Stay Rod And Stay Insulators With The Pole Of Required Tension By Providing Stay Clamps, Nuts, Bolts Etc. 22 Earthing Of Support With Ms Earth Rod Of ( 20X2500 ) Mm. Long Including Excavation Of Pit And Driving Ms Rod 3.0M Apart From Support And 0.5M Below The Ground Level And Connecting Below The Earth Electrodes With The Help Of G.I. Wire No.6 Swg Tightening With Nuts And Bolts. 23 Laying, Sagging, Stringing And Binding Of Acsr Weasel / Dog Conductor With All Other Accessories On Pole As Per Respo Norms. 24 Laying, Sagging, Stringing And Binding Of Abc Conductor With All Other Accessories On Pole As Per Respo Norms. 25 Laying Of 11 Kv Xlpe Cable Of Size 3X70 Sq.Mm. / 3X120 Sq.Mm. / 3X180 Sq.Mm. And Making Connections As Per Respo Norms. 26 Filling And Fixing Of 11 Kv Outdoor / Indoor Type Cable Jointing Kits As Per Respo Norms. 27 Construction Of 11 Kv Underground Line :- 28 Digging Of Cable Trench In Size Of 0.45Mtr.X1.05 Mtr. 29 Laying Of 11 Kv 3X70 / 120 / 185 Sq.Mm. Cable In The Trench. 30 Providing 150 Mm. Sand Cushion Beneath And 150 Mm. Above The Cable. The Cable Shall Be Duly Protected By 1St Class Bricks, Two On Either Side And Third On Top Of The Cable, Laid In The Series One After The Other. 31 Refilling And Ramming Of The Left Out Soil, Closing And Trench And Levelling. Spare Cable Shall Be Left In The Loop Shape At Both Ends, Including Providing Of All Required Material And T&P. 32 Providing And Fixing Of Danger Board With Clamp, Nut And Bolts. 33 Providing And Fixing Of Number Plate With Clamp, Nut And Bolts. 34 Providing And Wrapping Of Barbed Wire On 11 Kv Pcc Poles At A Height Of 2.75 Mtr. From The Ground Level As Per Respo Norms. 35 Fitting Of 11 Kv Pilfer Proof Metering Cubical Including Making Proper Connections. 36 Guarding Of 11 Kv Line With G.I. Wire As Per Respo Norms. 37 Mounting And Fixing Of 11 Kv Ct / Pt Unit On Double Pole Including Making Proper Connections. 38 Fixing Of 11 Kv 3Ph-4W Tvm Meter At Double Pole Including Making Proper Connections. 39 Mounting And Fixing Of 10 Kva Transformer On Pole Including Making Proper Connections. 40 Mounting And Fixing Of 25 Kva Transformer On Double Pole Including Making Proper Connections. 41 Mounting And Fixing Of 63 Kva Transformer On Double Pole Including Making Proper Connections. 42 Mounting And Fixing Of 100 Kva Transformer On Double Pole Including Making Proper Connections. 43 Providing G.I. Pipe 6” Dia For Inserting 11 Kv Xlpe Cable For Safety Of Cable On Single / Double Pole By Providing And Fixing Of Ms Clamp, Nuts And Bolts. 44 Fixing And Fitting Of Single / Three Phase Distribution Box On Pole For Making Consumers Cable Connection Complete Work. 45 Carriage Of Following From Work Site To Store Centre Majhola Including Loading And Unloading At Both Ends :- 46 13 Mtr. / 11 Mtr. / 9 Mtr. Long St Poles. 47 Acsr Weasel / Dog Conductor / M.S. Scrap. 48 Ct / Pt Unit. 49 11 Kv Pilfer Proof Metering Cubical.

Key Value

Document Fees
INR 590 /-
EMD
INR 2000.0 /-
Tender Value
INR 2 Lakhs /-

BOQ Items

Name of Work: Work in deposite scheme in the area of EDSD-Majhola under EDD-1 Moradabad.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Safe carriage of the following material from Store Centre Majhola/JE's store to work site including loading and unloading at both ends :- BI01010001010000000000000515BI0100001112
2 1.01 13 Mtr./11 Mtr./9 Mtr./8.5 Mtr. Long PCC/ST Poles. BI01010001010000000000000515BI0100001113 1 Nos
3 1.02 ACSR Weasel/Dog Conductor. BI01010001010000000000000515BI0100001114 1 Mtr
4 1.03 11/0.4 10 KVA Transformers. BI01010001010000000000000515BI0100001115 1 Nos.
5 1.04 11/0.4 25 KVA Transformers. BI01010001010000000000000515BI0100001116 1 Nos.
6 1.05 11/0.4 63 KVA Transformers. BI01010001010000000000000515BI0100001117 1 Nos.
7 1.06 11/0.4 100 KVA Transformers. BI01010001010000000000000515BI0100001118 1 Nos.
8 1.07 LT A.B.C. Cable. BI01010001010000000000000515BI0100001119 1 Mtr
9 1.08 11 KV XLPE cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x180 sq.mm. etc. BI01010001010000000000000515BI0100001120 1 Mtr
10 1.09 Line material such as Cross-Arms, Pin Insulators, Guarding Angles, Guarding Wire, Disc Insulators and Cable Jointing Kits etc. BI01010001010000000000000515BI0100001121 1 Qtl
11 1.1 CT/PT Unit BI01010001010000000000000515BI0100001122 1 Nos
12 1.11 11 KV pilfer proof metering cubical. BI01010001010000000000000515BI0100001123 1 Nos
13 2 Dismantling of the line by :- BI01010001010000000000000515BI0100001124
14 2.01 Removing of ACSR Weasel/Dog conductor from all phases on line, making bundle and stacking at a safe place. BI01010001010000000000000515BI0100001125 1 Mtr
15 2.02 Uprooting of 13 Mtr./11 Mtr./9 Mtr./8.5 Mtr. Long PCC/ST Poles. BI01010001010000000000000515BI0100001126 1 Nos
16 3 For 11 KV Line, Single support 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) complete with fixing of 11 KV V-Type cross-arms and all other accessories by providing stone pad, cross arms, holding clamps, f-bracket and nuts & bolts etc. as per RESPO Norms. BI01010001010000000000000515BI0100001127 1 Nos
17 4 For 11 KV Line, Double Pole structure with 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of D.P. Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms. BI01010001010000000000000515BI0100001128 1 Nos
18 5 Construction of Tri-Pole Structure on ST Poles including fabrication of MS Angle Channel, Cross Bracing etc. with proving and fitting of all type of clamps made of MS Flat of size 65x8mm. with Nuts, Bolts & washer, grouting of pole in size of 220x45x45 cm. with Cement, Sand and Brick Ballast in the ratio of 1:4:8, as per RESPO Norms. BI01010001010000000000000515BI0100001129 1 Nos
19 6 Grouting of Poles Single line support :- Grouting of support in CC 1:4:6 (cement, sand and 40 mm. brick ballast) Grouting will be done in the block of size 45cm x 45cm x 1/6th of full length of the support upto ground level as per RESPO Norms. BI01010001010000000000000515BI0100001130 1 Nos
20 7 Grouting of stay rods (20x1800mm.) including all works of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6 (cement, sand and 40 mm. brick ballast) including back filling of soil and proper ramming etc. BI01010001010000000000000515BI0100001131 1 Nos
21 8 Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, nuts, bolts etc. BI01010001010000000000000515BI0100001132 1 Nos
22 9 Earthing of support with MS Earth Rod of (20x2500)mm. long including excavation of pit and driving MS Rod 3.0M apart from support and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. Wire No.6 SWG tightening with nuts and bolts. BI01010001010000000000000515BI0100001133 1 Nos
23 10 Laying, sagging, stringing and binding of ACSR Weasel/ Dog Conductor with all other accessories on pole as per RESPO Norms. BI01010001010000000000000515BI0100001134 1 Mtr
24 11 Laying, sagging, stringing and binding of ABC Conductor with all other accessories on pole as per RESPO Norms. BI01010001010000000000000515BI0100001135 1 Mtr
25 12 Laying of 11 KV XLPE Cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x180 sq.mm. and making connections as per RESPO Norms. BI01010001010000000000000515BI0100001136 1 Mtr
26 13 Filling and fixing of 11 KV outdoor/indoor type cable jointing kits as per RESPO Norms. BI01010001010000000000000515BI0100001137 1 Nos
27 14 Construction of 11 KV Underground Line :- BI01010001010000000000000515BI0100001138
28 14.01 Digging of cable trench in size of 0.45Mtr.x1.05 Mtr. BI01010001010000000000000515BI0100001139 1 Mtr
29 14.02 Laying of 11 KV 3x70/120/185 sq.mm. cable in the trench. BI01010001010000000000000515BI0100001140 1 Mtr
30 14.03 Providing 150 mm. sand cushion beneath and 150 mm. above the cable. The cable shall be duly protected by 1st Class Bricks, two on either side and third on top of the cable, laid in the series one after the other. BI01010001010000000000000515BI0100001141 1 Mtr
31 14.04 Refilling and ramming of the left out soil, closing and trench and levelling. Spare cable shall be left in the loop shape at both ends, including providing of all required material and T&P. BI01010001010000000000000515BI0100001142 1 Mtr
32 15 Providing and fixing of Danger Board with clamp, nut and bolts. BI01010001010000000000000515BI0100001143 1 Nos
33 16 Providing and fixing of Number Plate with clamp, nut and bolts. BI01010001010000000000000515BI0100001144 1 Nos
34 17 Providing and wrapping of barbed wire on 11 KV PCC Poles at a height of 2.75 Mtr. from the ground level as per RESPO Norms. BI01010001010000000000000515BI0100001145 1 Nos
35 18 Fitting of 11 KV Pilfer proof metering cubical including making proper connections. BI01010001010000000000000515BI0100001146 1 Nos
36 19 Guarding of 11 KV Line with G.I. wire as per RESPO Norms. BI01010001010000000000000515BI0100001147 1 Span
37 20 Mounting and fixing of 11 KV CT/PT Unit on double pole including making proper connections. BI01010001010000000000000515BI0100001148 1 Nos
38 21 Fixing of 11 KV 3Ph-4W TVM Meter at double pole including making proper connections. BI01010001010000000000000515BI0100001149 1 Nos
39 22 Mounting and fixing of 10 KVA transformer on pole including making proper connections. BI01010001010000000000000515BI0100001150 1 Nos
40 23 Mounting and fixing of 25 KVA transformer on double pole including making proper connections. BI01010001010000000000000515BI0100001151 1 Nos
41 24 Mounting and fixing of 63 KVA transformer on double pole including making proper connections. BI01010001010000000000000515BI0100001152 1 Nos
42 25 Mounting and fixing of 100 KVA transformer on double pole including making proper connections. BI01010001010000000000000515BI0100001153 1 Nos
43 26 Providing G.I. Pipe 6” dia for inserting 11 KV XLPE cable for safety of cable on Single/Double Pole by providing and fixing of MS Clamp, Nuts and Bolts. BI01010001010000000000000515BI0100001154 1 Mtr
44 27 Fixing and fitting of single/three phase distribution box on pole for making consumers cable connection complete work. BI01010001010000000000000515BI0100001155 1 Nos
45 28 Carriage of following from work site to Store Centre Majhola including loading and unloading at both ends :- BI01010001010000000000000515BI0100001156
46 28.01 13 Mtr./11 Mtr./9 Mtr. Long ST Poles. BI01010001010000000000000515BI0100001157 1 Qtl
47 28.02 ACSR Weasel/Dog Conductor/M.S. Scrap. BI01010001010000000000000515BI0100001158 1 Qtl
48 28.03 CT/PT Unit. BI01010001010000000000000515BI0100001159 1 Nos
49 28.04 11 KV pilfer proof metering cubical. BI01010001010000000000000515BI0100001160 1 Nos
Disclaimer :