Assam State Co-operative Housing Federation Limited has published Construction Of Common Service Centre At Nilip , Karbi Anglong. Submission Date for this Tender is 22-08-2020. Building Work Tenders in Nilip, Karbi Anglong Assam. Bidders can get complete Tender details and download the document.
Name of Work: Construction of common serivice centre at Nilip, Karbi Anglong | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level\n(a) In Ordinary Soil. | 473.7 | m3 | |
2 | 2 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\nWith river sand or silt (predominantly non plastic ) by truck carriage including loading plastic ) by truck carriage including loading and unloading. | 342.22 | m3 | |
3 | 3 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1 cement : 4 sand : 8 coarse aggregate by volume | 20.01 | m3 | |
4 | 4 | Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). Using admixture, plasticizer etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.\nM20 or Prop 1:1.5:3. (Using Mixture Machine )\n(A) In sub structure up to plinth level.\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nUsing admixture, plasticizer etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.\n | 104.88 | m3 | |
5 | 5 | (B)(i) In super structure ::\nM20 or Prop 1:1.5:3. (Using Mixture Machine ) \n (a) Plinth lev to 1st floor level \nColumns, pillars, posts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of nosing.\nUsing admixture, plasticizer etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.\n | 61.5 | m3 | |
6 | 6 | (b) 1st floor to 2nd floor level \nColumns, pillars, posts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of nosing.\nUsing admixture, plasticizer etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. | 18.59 | m3 | |
7 | 7 | (c) 2nd to Roof level \nColumns, pillars, posts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of nosing.\nUsing admixture, plasticizer etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. | 15.98 | m3 | |
8 | 8 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | 85.84 | m2 | |
9 | 9 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)\n(a) From Primary Producer : TATA / SAIL/ Esser Steel/ Jindal Steel/ Shyam Steel/ RINL\nA. Upto 1st floor level | 244.52 | Qntl. | |
10 | 10 | B. 1st to 2nd floor level | 39.82 | Qntl. | |
11 | 11 | C. 2nd floor to Roof level | 28.723 | Qntl. | |
12 | 12 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc, height of propping and centering below supporting floor to ceiling not exceeding 4.0m. and removal of the same for in-situ reinforced concrete and plain concrete work in: Using 38mm thick plank\n3.1.1.1:Foundation, footing, bases of columns, pile cap, raft and mass concrete works etc. | 274.12 | m2 | |
13 | 13 | 3.1.1.2:Sides of tie beams, plinth beams, grade beams etc. at or below plinth level | 245.43 | m2 | |
14 | 14 | 3.1.1.3: (a) Columns, pillars, posts & strut Square, Rectangular, Polygonal in plan or any shape like\nTee/L etc. having plan vertical face. Using 38mm thick plank\n(a). Plinth to Ist Floor Level | 248.16 | m2 | |
15 | 15 | (b). Ist to 2nd floor Level | 93.72 | m2 | |
16 | 16 | (c). 2nd to Roof Level | 72.42 | m2 | |
17 | 17 | 3.1.1.3: (b) Circular or curved in plan (Using 38mm thick plank)\n(a). Plinth to Ist Floor Level | 3.11 | m2 | |
18 | 18 | 3.1.1.4: Sides and soffits of beams, lintels and horizontal ties for depth not exceeding 1.0M \nUsing 38mm thick plank\n(a). Plinth to Ist Floor Level | 304.32 | m2 | |
19 | 19 | (b). Ist to 2nd floor Level | 56.29 | m2 | |
20 | 20 | (c). 2nd to Roof Level | 56.27 | m2 | |
21 | 21 | 3.1.1.5: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconies and the like.\n(a) Floors etc. upto 200mm in thickness. Using 38mm plank.\n(a). Plinth to Ist Floor Level | 7.88 | m2 | |
22 | 22 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a) Brick on Flat soling | 826.48 | m2 | |
23 | 23 | Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed. In Sub-structure upto plinth level including dewatering if necessary\n (a) In proportion 1:4 | 64.38 | m3 | |
24 | 24 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embedded in cement mortar and will be measured and paid separately)\n112mm thick brick wall In prop 1:4.\n(a). Plinth to Ist Floor Level | 702.55 | m2 | |
25 | 25 | (b). Ist to 2nd floor Level | 150.69 | m2 | |
26 | 26 | (c). 2nd to Roof Level | 94.63 | m2 | |
27 | 27 | 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square meter of floor area) including curing etc. complete as directed. | 197.5 | m2 | |
28 | 28 | Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. 20 mm thick. | 29.55 | m2 | |
29 | 29 | Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirting's, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\na) Normal range : Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Makeof size 400mmx400mm and above | 405.283 | m2 | |
30 | 30 | Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirting's over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).\niii) Of size 300mmx450mm and above | 69.49 | m2 | |
31 | 31 | Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.\nCERAMIC : Executive range-1 (Sizes 400 mm x 400mm and above) \nSomany made- VC Shield (Group- 25) (405x405) mm. (a) Deluxe -VC | 328.68 | m2 | |
32 | 32 | Providing, fitting and fixing anodized aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately).\na) Side hung and Top hung windows and ventilators with 5mm frosted glass. | 3.25 | m2 | |
33 | 33 | Providing, fitting and fixing anodized aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(a) 2 Track sliding window with 5mm frosted glass. | 8.7 | m2 | |
34 | 34 | (b)3 Track sliding window. with 5mm frosted glass. | 38.04 | m2 | |
35 | 35 | Providing and fixing anodized aluminium framed double leaf doors of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48 mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mm x15mm x1.2mm complete with automatic floor mounted door closure, butterfly type handles, special cylindrical lock, concealed type aluminium tower bolt, neoprene dryset rubber gasket, door felt gasket, etc.complete as directed by the Department at all levels. \n(a) Double leaf doors\n(i)5mm thick frosted glass and 12mm thick prelaminated particle board | 26.64 | m2 | |
36 | 36 | Providing and fixing anodized aluminium framed single leaf door of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48 mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mmx15mmx1.2mm complete with automatic hydraulic floor mounted door closure, butterfly type handles, special cylindrical locks, concealed type tower bolt, neoprene dryset rubber gusket, etc.complete as directed by the Department at all levels. \n(i)5mm thick frosted glass and 12mm thick prelaminated particle board | 13.23 | m2 | |
37 | 37 | (v) Prelaminated Board | 34.34 | m2 | |
38 | 38 | 20 mm thick Cement plaster in two coats on single or half brick walls for exterior plastering including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed.\nA) On rough side (backing coat 15 mm and finishing coat 5mm thick). In cement mortar 1:4 \n(a). Up to Ist Floor Level | 422.51 | m2 | |
39 | 39 | (b). Ist to 2nd floor Level | 100.24 | m2 | |
40 | 40 | (c). 2nd to Roof Level | 77.46 | m2 | |
41 | 41 | 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nA) On rough side (backing coat 15 mm and finishing coat 5mm thick). In cement mortar 1:4\n(a). Up to Ist Floor Level | 430.45 | m2 | |
42 | 42 | B) On fair side (backing coat 10 mm and finishing coat 10mm thick). In cement mortar 1:4\nIn cement mortar 1:4\n(a). Up to Ist Floor Level | 852.95 | m2 | |
43 | 43 | (b). Ist Floor to 2nd floor Level | 100.24 | m2 | |
44 | 44 | (b). Ist Floor to 2nd floor Level | 77.46 | m2 | |
45 | 45 | Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\nThickness = 1.5 mm thick | 2061.29 | m2 | |
46 | 46 | Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after thoroughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | 1461.09 | m2 | |
47 | 47 | Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. | 600.2 | m2 | |
48 | 48 | Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after thoroughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. | 600.2 | m2 | |
49 | 49 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) \nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Department\n0.60 mm thick | 778.75 | m2 | |
50 | 50 | Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) (Dyna roof /Sathyam/ Durakolor/Century Wells) at all levels including fitting and fixing self drilling, self tapping screws complete complete.\n0.60 mm thick | 46.1 | m | |
51 | 51 | Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). (ii) 12.5mm thick. \n\n | 570.37 | m2 | |
52 | 52 | Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. \na) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997 | 100.63 | Qntl | |
53 | 53 | Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution. | 371.06 | m2 | |
54 | 54 | Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution. | 159.24 | m2 | |
55 | 55 | Pre construction anti - termite treatment by applying in the entire leveled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution. | 570.37 | m2 | |
56 | 56 | Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution. | 125.04 | m | |
57 | 57 | Providing plinth protection with bricks laid on edge and grouted with cement mortar 1:4 and finishing with cement pointing in prop. 1:1 complete. | 69.6 | m2 | |
58 | 58 | Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. | 1500 | Metre. | |
59 | 59 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including earth continuity in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system .\nWith 3 x 10 sq. mm. + earth continuity with2x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | 80 | Metre. | |
60 | 60 | Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete\n Medium point up to 6.00 metre. Length. | 200 | Each | |
61 | 61 | Long point up to 10.00 metre. Length. | 54 | Each | |
62 | 62 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.\n Long point up to 10.00 metre. Length. | 3 | Each | |
63 | 63 | Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required: | 200 | Metre | |
64 | 64 | Supply and fixing 32 mm mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required: | 80 | Metre | |
65 | 65 | Supply and fixing 19 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required: | 40 | Metre | |
66 | 66 | Supply and fixing 25 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required: | 40 | Metre | |
67 | 67 | Supply and fixing 32 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required: | 30 | Metre | |
68 | 68 | Supply and fixing 38 mmdia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required: | 25 | Metre | |
69 | 69 | Supplying and fixing 18 S.W.G sheet steel metal boxes of the following sizes in surface Wiring system with suitable size of 3 mm thickness phenolic laminated sheet cover on the front face of the boxes including painting etc. as required and specified by the department.\n 250 mm x 300 mm x 60 mm deep (Nominal size | 16 | Each | |
70 | 70 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting vertical TPN MCB DB incorporated with bas-bar 125A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make)\n 4 way TPN (8+12) double door | 1 | Each | |
71 | 71 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting vertical TPN MCB DB incorporated with bas-bar 125A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \n8 Way SPN Double door | 3 | Each | |
72 | 72 | Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nB Series\n(Schneider MG, legrand, Hager make)\n6 to 32A | 3 | Each | |
73 | 73 | Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nB Series\n(Schneider MG, legrand, Hager make)\n6 to 32A | 36 | Each | |
74 | 74 | C Series\n(Schneider MG, legrand, Hager make)\n6 to 32A | 6 | Each | |
75 | 75 | Supplying with fitting and fixing Panel mounting open execution 25 KA ,415V 50Hz 4P MCB(Ics=Icu,adjustable Ir setting 0.7) without enclosure )of the following capacity complete with making necessary connection as approved specified and directeted by the deptttion as approved, specified and directed by the deptt.\n25KA 415 V,50Hz 4P MCCB(Schneider,Legrand,Siemens,Indo Asian make)\n100A | 1 | Each | |
76 | 76 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n63A | 3 | Each | |
77 | 77 | Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nABB, Schneider, legrand, L&T make)\n100A | 1 | Each | |
78 | 78 | Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | 10 | Each | |
79 | 79 | Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.\n120 watt electronic modular 5 step speed control 2 - module | 26 | Each | |
80 | 80 | Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. | 22 | Each | |
81 | 81 | Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. | 254 | Each | |
82 | 82 | Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.\n3 module type Metal | 12 | Each | |
83 | 83 | 4-5 module type Metal | 6 | Each | |
84 | 84 | 8 Module type Metal | 9 | Each | |
85 | 85 | 24 module type Metal | 4 | Each | |
86 | 86 | Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.\n3 module | 3 | Each | |
87 | 87 | 4 module | 6 | Each | |
88 | 88 | 8 Module | 9 | Each | |
89 | 89 | 24 module | 4 | Each | |
90 | 90 | Supplying and fixing of batten holder including 11 W CFL lamp and connection as approved by the Deptt.)as required. | 22 | Each | |
91 | 91 | Supplying extra down rod of 10 cm long G.I. pipe 20 mm dia heavy gauge including painting etc. as required | 18 | Each | |
92 | 92 | Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)\nEnergy efficient 5-star 1200 mm sweep Fusion 5 star (Havells or equivalent make) | 25 | Each | |
93 | 93 | Compact and Sleek Channel type CFL luminaries in white epoxy power coated finish and Decorative click fit end caps and Electronic ballast with 1 X 36 W CFL(Crompton Greaves make Model- TAK 36 EB e-AKTIV or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make). | 52 | Each | |
94 | 94 | LHFD01130674 30 W LED 6K Havells or equivalent make JETA 30 LED Asymmetrical floodlight used for sports lighting, area lighting, security lighting, signage lighting& facade lighting. Luminaries housing & Control gear Box is of cast aluminium with heat sink for better heat transmission& toughened glass cover which provides IP 65 Degree of protection. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ WIPRO/ BAJAJ/ CROMPTON / HPL/ SOLAR/ JAQUAR make). | 8 | Each | |
95 | 95 | FBH 250 2 X PL-T/ 4P 32 W HF , 240V Phillip make Space recess mounted high performance down light with high reflectivity reflector and with remote gearbox, suitable for high ceilings including lamp. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent WIPRO/ JAQUAR make). | 17 | Each | |
96 | 96 | 42/60W, BBG 150/151 LED 50/ NW PSU 220-240 V IP 67. or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent WIPRO/ JAQUAR make). | 6 | Each | |
97 | 97 | Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED round fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. \nLED Round Light,12W | 12 | Each | |
98 | 98 | Supplying and fitting fixing of electric storage water heater [Geyser] of AOS-Jaquar make) including necessary connection etc. as required complete and as directed by the Department. \n 15 Litre Capacity (Digital model) | 1 | Each | |
99 | 99 | Supply including installation ,connection as approved by the Deptt.testing and commissioning of Openwell submerssible Pump set Complete with Submerssible cable etc.as directed and specified by the Deptt.\n1.5 HP Single phase open well submersible monoblock watercooled pumpSet(Crompton Greaves/Aquatic/CRI/V-Guardmake)220V,50Hz,2900RPM with control panel | 1 | Each | |
100 | 100 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . \n 4 Core A2XWY A2XFY \n 16.00 Sq. mm.4 Core armoured U.G. cable | 70 | Metre | |
101 | 101 | Supply with installation & commissioning of readymade maintenance free CPRI approved technology G.I. CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt. | 2 | Each | |
102 | 102 | Supplying & laying of 8 SWG Copper earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. | 80 | Metre. | |
103 | 103 | Furniture Including GST, Bed without box 1500mmx2000mm | 2 | Each | |
104 | 104 | Table 800mmx450mm | 2 | Each | |
105 | 105 | Chair with arm | 2 | Each | |
106 | 106 | Almirah 2-door with mirror | 2 | Each | |
107 | 107 | Sofa | 3 | Each | |
108 | 108 | Centre table | 1 | Each | |
109 | 109 | Side table | 2 | Each | |
110 | 110 | Office executive table | 1 | Each | |
111 | 111 | Chair (high back) | 1 | Each | |
112 | 112 | Chair (Visitor) | 5 | Each | |
113 | 113 | Dining table 8-seater | 2 | Each | |
114 | 114 | Chair (dining) | 16 | Each | |
115 | 115 | Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately)\nIndian type Orissa pattern of size 500mm\na) White (Jaguar make) | 12 | Each | |
116 | 116 | Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)\nA) Parryware make\n(a) White(v) Water closet SLICK "P(Cat.No.20011) (inclusive of seat cover) | 3 | Each | |
117 | 117 | Providing fitting and fixing Vitreous china wall hung water closet (European type W.C pan 400mm high) with seat and lead, CP brass hinges and rubber buffers , CI/MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)\ni) Parryware make\n(a) White\n(iv) Deluxe Dual Flush (Cat No.C8110) | 15 | Each | |
118 | 118 | Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.\n(B) Hindware Make\n(a) White\n(i) New Magnum (Cat. No.C0575) | 9 | Each | |
119 | 119 | Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\n PEDESTAL BASIN (with pedestal)\n(B) Hindware make\n(a) White\n(xi) Opal 670 x 510 (Cat. No.10082/11032) | 14 | Each | |
120 | 120 | Providing fitting and fixing Wall Mounted Mirror complete as directed and specified.\n(A) Parryware Make\n(b) Size 600mm x 450mm | 4 | Each | |
121 | 121 | Providing fitting and fixing Glass Shelf complete as directed and specified.\nGlass shelf with C.P. guard rail\n (i) Agmeco make (a) Cubin (Cat. No.CB-00104) | 4 | Each | |
122 | 122 | Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified.\n(A) Parryware Make\n(i) Recess SP & SG dish (Cat.No. C9935) | 10 | Each | |
123 | 123 | Providing, fitting and fixing CP towel rail complete as directed and specified.\n(b) Sona make\n(x) Towel rail with hook 900mm long (Cat.No.TR-0606) | 5 | Each | |
124 | 124 | Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings, cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately\n(A) Parryware Make\n(i) Single Bowl with Veg Bowl & Drain Board (400 x 200) Flat Edge- Glossy (Cat.No.C8545) | 1 | Each | |
125 | 125 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified.\nConcealed by chiselling or breaking brick wall/ c.c./ R.c.c. and making good to the damages.\ni) 110mm dia. | 239 | Each | |
126 | 126 | ii) 75mm dia. | 219 | Each | |
127 | 127 | Supply fitting and fixing 45 degree PVC bend of (Supreme/ prince) or other ISI approved including joining, fitting and fixing with long screw fitting, H.W. clamps etc. completed at all levels including bellow G.L. as directed and specified.\nConcealed by chiselling or breaking brick wall/ c.c./ R.c.c. and making good to the damages.\nii) 75mm dia. | 10 | Each | |
128 | 128 | Supplying, fitting and fixing H.C.I bend with door including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified.\nIn exposed surfaces or trenches\nii) 100mm dia. | 10 | Each | |
129 | 129 | Supply fitting and fixing PVC plain single tee of (Supreme/ prince) or other ISI approved including joining, fitting and fixing with long screw fitting, H.W. clamps etc. completed at all levels including bellow G.L. as directed and specified.\nConcealed by chiselling or breaking brick wall/ c.c./ R.c.c. and making good to the damages. \nii) 110mm dia. | 10 | Each | |
130 | 130 | Supply fitting and fixing PVC single tee with door of (Supreme/ prince) or other ISI approved including joining, fitting and fixing with long screw fitting, H.W. clamps etc. completed at all levels including bellow G.L. as directed and specified.\nConcealed by chiselling or breaking brick wall/ c.c./ R.c.c. and making good to the damages.\nii) 110mm dia. | 4 | Each | |
131 | 131 | Supplying, fitting and fixing Kitchen chimney including water proof ply board, plain sheet, decorative prelaminated sheet, nail, fevicol, dendrite, wooden beading etc.as required complete as specified and directed by the department. | 1 | Each | |
132 | 132 | Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. \n100 Users | 1 | Each | |
133 | 133 | Providing fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified | 2 | Each | |
134 | 134 | Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. | 7.16 | Cum | |
135 | 135 | Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. | 1 | Each | |
136 | 136 | Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified.\n(B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.\nd) 25 mm dia (Medium)\ni) Using Tata make | 314 | R.m | |
137 | 137 | f) 15 mm dia (Medium)\ni) Using Tata make | 485.37 | R.m | |
138 | 138 | Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately)\nAgmeco brand \n(iii) Bib Cock Long spout with Flange CAT No.CC 00205/CAT No.CN 0020 | 14 | Each | |
139 | 139 | Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately)\nAgmeco brand \n(a) 15mm dia(Male/ Female ) | 14 | Each | |
140 | 140 | Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. \n(I) Jaquar\n(a) Continental | 14 | Each | |
141 | 141 | Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) \nCrabtree Frattini brand\na) Maestro (i) Sink cock with swinging regular spout | 1 | Each | |
142 | 142 | Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately)\nJaquar make\na) Continental\n(iii) Pressure adjustable shower with revolving joint | 4 | Each | |
143 | 143 | Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed \nvi) 50mm diameter | 110 | R.m. | |
144 | 144 | Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. | 110 | R.m. | |
145 | 145 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. | 110 | R.m. | |
146 | 146 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. | 1 | Each | |
147 | 147 | Supplying fitting and fixing check valve (non return valve) including thread to pipes. | 2 | Each | |
148 | 148 | Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes\n(I) 2000 Lt capacity\n(b) Polycon make | 1 | Each | |
149 | 149 | Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of DOLPHIN make with all necessary fittings such as valve,bib cock,pipe connection etc.with a free maintanance period of six monthhs\n(II) 2000 Lt capacity\n(a) 4 mm thick Vessel | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy