Repair And Replacement Of Internal Electrification In Jco/Or Md Accn At Shikargarh Enclave Under Ge Shikargarh In Army Area Jodhpur, GE SHIKARGARH-Rajasthan

Military Engineer Services-MES has published Repair And Replacement Of Internal Electrification In Jco/Or Md Accn At Shikargarh Enclave Under Ge Shikargarh In Army Area Jodhpur. Submission Date for this Tender is 22-08-2020. Electrification Work Tenders in GE SHIKARGARH Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

25116951
Repair And Replacement Of Internal Electrification In Jco/Or Md Accn At Shikargarh Enclave Under Ge Shikargarh In Army Area Jodhpur
Open Tender
Indian
Rajasthan
GE SHIKARGARH
22-08-2020

Tender Details

Repair And Replacement Of Internal Electrification In Jco/Or Md Accn At Shikargarh Enclave Under Ge Shikargarh In Army Area Jodhpur

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work: REPAIR AND REPLACEMENT OF INTERNAL ELECTRIFICATION IN JCO/OR MD ACCN AT SHIKARGARH ENCLAVE UNDER GE SHIKARGARH IN ARMY AREA JODHPUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down carefully existing unserviceable aluminum/copper point wiring of any description & in any position with and including taking out and removing existing wooden battens/conduits /casing caping fixed on surface and all fittings including unserviceable sunken/surface boxes & terminal/junction boxes of any description, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including taking out and removing serviceable fittings/fixtures for reuse at site or depositing to MES store and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed 2230 Each point
2 2 M&L for point wiring for one light/fan/bell point controlled by one one way switch complete with multistrnaded copper conductor 1.5 sqmm size PVC insulated FRLS unsheathed cable 1100 volt grade, conforming IS 694 & color code in PVC casing caping suitable capacity (minimum size 25 mm) in pressed steel terminal boxes of required size not less than 1.6 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multistranded conductor copper 1.5 sqmm size multistranded PVC insulated unshethed cable as earth wire to common earth and connected to earth dolly drawn in same casing capping complete all as specified. Make of wire : Finolex/Havells/KEI/Polycab, Make of PVC casing caping : Finolex/Precision/Polycab/Presto-Plast. 1406 Each point
3 2.1 ditto but for One 3 Pin 5 Amps socket outlet on same board 260 Each point
4 2.2 ditto but for One 3 Pin 5 Amps socket outlet on independent board. 380 Each point
5 2.3 ditto but for One light point controlled by two,two way switches 24 Each point
6 3 All as per item No 2 above but using 4.0 Sqmm PVC insulated, unsheathed cable for one 3 Pin socket outlet 15 Amps on independent board. 160 Each point
7 4 Supply and fixing switch piano, flush type ,single pole one way 5/6 Amps 240 Volts, AC circuit complete all as specified and directed. \nMake : Anchor Penta / Cona /SSK 1406 Each
8 5 Supply and fixing switch piano, flush type ,single pole two way 5/6 Amps 240 Volts, AC circuit complete all as specified and directed. \nMake : Anchor Penta / Cona /SSK 48 Each
9 6 Supply and fixing switch piano, flush type ,single pole one way 15/16 Amps 240 Volts, AC circuit complete all as specified and directed. \nMake : Anchor Penta / Cona /SSK 160 Each
10 7 S/F Socket outlet 2 in 1, 3 pin, 5A universal flush shuttered type ISI mark complete all as specified and directed. \nMake : Anchor Penta / Cona /SSK 640 Each
11 8 S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush shuttered type ISI mark complete all as specified and directed. \nMake : Anchor Penta / Cona /SSK 160 Each
12 9 S&F Bell Switch 5 Amps flush type Single pole 240 volts ISI marked complete all as specified and directed. \nMake : Anchor Penta / Cona /SSK 20 Each
13 10 S/F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed. \nMake : Anchor Penta / Cona /SSK 1430 Each
14 11 Supply and fix door Bell Ding Dong type complete all as specified and directed. \nMake : Anchor Penta /Cona/SSK. 60 Each
15 12 S&F fan regulator electronic, deluxe rotary step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed. \nMake : Anchor Penta /Cona/SSK. 180 Each
16 13 M&L for Sub main wiring with PVC insulated but unsheathed 2x6 sqmm multi stranded copper conductor cable passing through and incl PVC casing caping on wall (by means of screw incl making good existing ) ISI marked and casing caping accessries fixed on surface of wall, ceiling etc, making good the disturbed surface with and incl 1x6 sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire (green colour) including taking down old one. Note:- Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of PVC casing caping will be measured as one length including making good the disturbed surfaces. Make of wire : Finolex/Havells/KEI/Polycab, Make of PVC casing caping : Finolex/Precision/Polycab/Presto-Plast. 800 RM
17 14 All as above item No 13 but using 2x4 Sqmm cable single core copper with 4 Sqmm copper conductor as earth lead. \nMake of wire : Finolex/Havells/KEI/Polycab, Make of PVC casing caping : Finolex/Precision/Polycab/Presto-Plast. 320 RM
18 15 All as above item No 13 but using 3x10 Sqmm cable single core copper with 1 x10 Sqmm copper conductor as earth lead.\nMake of wire : Finolex/Havells/KEI/Polycab, Make of PVC casing caping : Finolex/Precision/Polycab/Presto-Plast. 80 RM
19 16 S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified Make:Legrand cat No 5078 11 or equivalent ABB/Scheinder. 20 Each
20 17 Fixing only LED light 22/20/18 watt including taking down old one all as specified and directed. \nNote : LED lights shall be issued under Sch 'B' free for fixing only\n 750 Each
21 18 Fixing only LED light 10/12 watt including taking down old one all as specified and directed. \nNote : LED lights shall be issued under Sch 'B' free for fixing only\n 240 Each
22 19 S&F 05 Watt LED Batten with extruded aluminium housing in 1 Feet Length with in Built LED strip, LED shall be having 400 system lumens, 3 stage CCCV driver with voltage range of 150-270 AC and DC output operating voltage of driver should be complied to SELV norms not exceeding 72 DC only including taking down old one complete all as specified and directed. Make :- CG / Wipro / Philips. 100 Each
23 20 Taking down carefully UNSV main switch and DB's including MCBs of any size, make, type and capacity removing materials to store for keeping in safe custody for re-use at site/Sch of credit and making good disturbed surface of walls, floors, etc.all as directed. 61 Each
24 21 S&F sheet metal enclosure triple pole and neutral 415 Volts 4 way (TPN) with 100 Amps rated coper busbar and MCB for double door having IP 43 protection flush mounting MCB shall be measured separately complete all as specified and directed Make: Legrand Cat No- 5076 70 or equivalent ABB/Scheinder/L&T. 20 Each
25 22 S&F Distribution boards 415 V ,8 way SPN with 100 Amps rated coper busbar and MCB for double door having IP 43 protection flush mounting MCB shall be measured separately complete all as specified and directed . Cat No- 507611 Make: Legrand or equivalent ABB/Scheinder/L&T. 30 Each
26 23 S&F MCB SP 6 to 32 Amps 10 KA, 240 V, C curve complete all as specified and directed . Make: Legrand Cat No 4085 90 or equivalent ABB/Scheinder/L&T. 360 Each
27 24 S&F MCB SPN 32 amps 10 KA, 240 V, C curve complete all as specified and directed . Make: Legrand Cat No 4086 17 or equivalent ABB/Scheinder/L&T. 96 Each
28 25 S&F MCB TPN 63 amps 10 KA, 415 V,C curve complete all as specified and directed . Make: Legrand Cat No 4086 83 or equivalent ABB/Scheinder/L&T. 32 Each
29 26 S & F of MCCB 3 Pole 100 Amps 36 KA All as directed by EIC. Make: Legrand or equivalent ABB/Scheinder/L&T. 1 Each
30 27 S& F sheet metal enclosure triple pole and neutral 415 Volts 4 way (TPN) with 250 Amps rated coper busbar with MCCB 160 A, TPN 415 V as incommer with door cover having IP 43 protection flush mounting MCB shall be measured separately complete all as specified and directed . Make: Legrand Cat No- 5077 45 or equivalent ABB/Scheinder/L&T. 1 Each
31 28 Earthing complete with GI steel earth plate eletrode 60 cm X 60 cm X 6.0 mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metres below level ground,connected to Gl iron or steel earth wire 4 mm dia (8 SWG) by means of nuts,bolts checks nuts and washers made of Gl iron or steel earth wire protected by Gl iron pipe 15 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6:) type C1, pre-cast RCC coverslab 30 cm X30 cm X 10 cm with one lifting handle made of 8 mm dia ms bar funnel wire mesh,20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges,necessary excavation and earth work in any type of soil complete all as shownin electrical plate No 3 of MES schedule part-I and testing after completion. 30 Each set
32 29 M/L for cutting of PCC/Kota stone floor/plinth /wall/road etc for insertion of GI pipe for protection of GI wire of earthing including making good disturbed surface. 18 RM
33 30 Taking down existing unserviceable static meter and Fixing only AC single phase static energy meter all as specified and as directed by Engr-in-Charge. Note 1 :- Energy Meters shall be issued under Sch 'B' free for fixing only. Note 2 :- Unserviceable meter will be deposted to MES store yard. 150 Each
34 31 Fixing only LED Street light 45/60/90 watt including taking down old one complete all as specified and directed by Engr in Charge. Note : LED lights shall be issued under Sch 'B' free for fixing only\n 100 Each
35 32 S&F of GI pipe bracket 40 mm dia light grade pipe 1.5 mtr long bent to shapeas directed including nut,bolts,washers and clamp etc and necessary 1.5 Sqmm 3 core sheathed copper PVC cable for connection including taking down old one complete all as specified and directed by Engr in Charge. 60 Each