Welcome Maintenance / Repair To Electric Wiring / Fitting / Fixture In Otm And Md Accn At Arty Centre And Aop Area Under Ge Nasik Road Camp . As Per Tender Documents, Garrison Engineer Nasik Road-Maharashtra

Military Engineer Services-MES has published Welcome Maintenance / Repair To Electric Wiring / Fitting / Fixture In Otm And Md Accn At Arty Centre And Aop Area Under Ge Nasik Road Camp . As Per Tender Documents. Submission Date for this Tender is 28-08-2020. Electrification Work Tenders in Garrison Engineer Nasik Road Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

25112715
Welcome Maintenance / Repair To Electric Wiring / Fitting / Fixture In Otm And Md Accn At Arty Centre And Aop Area Under Ge Nasik Road Camp . As Per Tender Documents
Open Tender
Indian
Maharashtra
Garrison Engineer Nasik Road
28-08-2020

Tender Details

Welcome Maintenance / Repair To Electric Wiring / Fitting / Fixture In Otm And Md Accn At Arty Centre And Aop Area Under Ge Nasik Road Camp . As Per Tender Documents

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work : WELCOME MAINT / REPAIR TO ELECTRIC WIRING / FITTING / FIXTURE IN OTM AND MD ACCN AT ARTY CENTRE AND AOP AREA UNDER GE NASIK ROAD CAMP.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc\n( Note - old serviceable switch / socket / regulator / switch-socket / call bell / bell push shall be reused against apropriate items, all as specified and directed by Engr-in-Charge) 775 PER POINT
2 2 Taking down unserviceable/partly serviceable light fittings any type, tube light fitting and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing / distempering to match with existing wall / floor / ceiling finishes.\n(Note - old serviceable fitting shall be reused against apropriate items, all as specified and directed by Engr-in-Charge) 625 EACH
3 3 Taking down and hanging during point wiring of ceiling fan/exhaust fan of any size and sweep in proper manner and connecting up including provision of cable from ceiling rose or connector to fan all as per specified and directed by Engr-in-Charge 105 EACH
4 4 Dismantling unserviceable main switch / DBs with MCBs and wooden board including making good disturbed surface of wall. 22 EACH
5 5 Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces. 900 RM
6 6 Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified One light point controlled by one, one way switch.\nNote : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. 350 PER POINT
7 7 All as per Ser item No. 06 above, but One ceiling /exhaust fan point controlled by one switch and regulator 105 PER POINT
8 8 All as per Ser item No. 06 above, but One 3 pin 5 amp socket out point on the same board with other switches. 98 PER POINT
9 9 All as per Ser item No. 06 above, but One 3 pin 5 amps socket out let point on independent board 112 PER POINT
10 10 All as per Ser item No. 06 above, but One bell/buzzer point controlled by one bell push. 20 PER POINT
11 11 All as per same in item No 06 above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire. 90 PER POINT
12 12 S &F in repair Switch piano flush type single pole one way 5 amps. 670 EACH
13 13 S &F in repair Socket out let 2 in one, 5/3 pin 5Amp 160 EACH
14 14 S &F in repair Switch socket combination 5 Amps 5 pin flush type 180 EACH
15 15 S &F in repair Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal . 130 EACH
16 16 S &F in repair Ceiling rose, surface bakelite 65x50 mm three terminal 400 EACH
17 17 S &F in repair Call bell AC-230 Volt single pole ding dong 30 EACH
18 18 S &F in repair Bell push, flush type 5 Amps. 30 EACH
19 19 S &F in repair Electronic regulator 100/120 Watt step type 150 EACH
20 20 Supply and fixing in repair of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED bulb 9 watt. 240 EACH
21 21 S & F in repair 8W, 6000K surface mounted LED , including connecting up with twin core twisted flexible copper conductor cable with suitable size, 230V, 50Hz, complete all as specified. \n 30 EACH
22 22 Supply & fix LED down lighter,6 W including cutting of ceiling cutout and connecting up with twin core twisted flexible copper conductor cable of suitable size, 230V, 50Hz, complete all as specified and directed by Engr-in-Charge.\n 5 EACH
23 23 Supply & fix LED down lighter, 9W including cutting of ceiling cutout and connecting up with twin core twisted flexible copper conductor cable of suitable size, 230V, 50Hz, complete all as specified and directed by Engr-in-Charge.\n 5 EACH
24 24 S & F in repair for decorative wall light fixture made up of polycarbonate, suitable for 10W retrofit LED lamp (Spiral B-22 base) with suitable LED lamp of 10W including connecting up with twin core twisted flexible copper conductor cable with suitable size, 230V, 50Hz, complete all as specified.\n 20 EACH
25 25 S & F 20 Watt Batten (4 feet) suitable for LED T8 lamps including coneecting up with 2 core flexible coppper conductor cable and mounting clamps & PVC squre box 75x75mm - 2 Nos etc, all as specified and directed by Engr-in-Charge. 250 EACH
26 26 S & F 20 Watt LED Tube Light (4 feet) suitable for T8 Batten including provision of suitable type of bipin holders- 02 Nos for each fitting, internal wiring of old fitings/fixtures if required, all as specified and directed by Engr-in-Charge 550 EACH
27 27 S & F in repair for decorative wall light fixture made up of polycarbonate, suitable for 12W retrofit LED lamp (Spiral B-22 base) with suitable LED lamp of 10W including connecting up with twin core twisted flexible copper conductor cable with suitable size, 230V, 50Hz, complete all as specified.\n 20 EACH
28 28 S & F 18 Watt Batten (4 feet) suitable for LED T8 lamps including coneecting up with 2 core flexible coppper conductor cable and mounting clamps & PVC squre box 75x75mm - 2 Nos etc, all as specified and directed by Engr-in-Charge. . 200 EACH
29 29 S & F 18 Watt LED Tube Light (4 feet) suitable for T8 Batten including provision of suitable type of bipin holders- 02 Nos for each old fitting, internal wiring of old fitings/fixtures if required, all as specified and directed by Engr-in-Charge 450 EACH
30 30 Supply & fix LED down lighter, 12W including cutting of ceiling cutout and connecting up with twin core twisted flexible copper conductor cable of suitable size, 230V, 50Hz, complete all as specified and directed by Engr-in-Charge.\n 5 EACH
31 31 Supply & fix LED down lighter, 15W including cutting of ceiling cutout and connecting up with twin core twisted flexible copper conductor cable of suitable size, 230V, 50Hz, complete all as specified and directed by Engr-in-Charge.\n 5 EACH
32 32 S & F in repair Moon (Opal) decorative gate/garden light made up of high grade unbreakable polycarbonate material suitable for retrofit CFL / LED 8 W /14 W (TU) B22 base including connecting up with twin core twisted flexible copper conductor cable, 14W LED lamp, housing PVC pipe etc complete all as specified and directed. \n 40 EACH
33 33 Supply & fix LED tube light along with fixture,10 W, 2 Feet including coneecting up with 2 core flexible coppper conductor cable and mounting clamps & PVC squre box 75x75mm - 2 Nos etc, all as specified and directed by Engr-in-Charge . 20 EACH
34 34 Refixing of tube light from exisiting position to new position as required at site all as directed and specified.\n(Note:- The old serviceable fittings will be used as removed against item No-2 above) 140 EACH
35 35 Refixing of wooden/PVC rectangular block for mounting, switches, sockets,fan regulator, call bell, bell push etc. with 3 mm thick plastic laminated sheet cover/helum sheet of ISI mark as required on ground including casing capping /conduit of any size, all as specified and directed by Engr-in-Charge. \n(The old serviceable material will be used as removed against item No-1 above) 290 EACH
36 36 Refixing of DB's including MCB's of any size, all as specified and directed by Engr-in-Charge. \nNote:- The material shall be used as removed against item No 4. 20 EACH
37 37 Supply and fix LED security/street light 15 W IP 65 , including coneecting up with 2/3 core flexible coppper conductor cable , compete all as specified and directed by Engr-in-Charge. 25 EACH
38 38 Fabrication,supply & fixing of GI pipe bracket up to 40 mm dia- 0.9m long & 2 set of clamps made out of 30 x 5 mm ms flat & fixed with anchor bolt suitable for 12 / 15 w LED security light fitting 25 EACH
39 39 S & F in repair 1X9W LED PL-Lamp suited for installation in existing 2G11 lamp holders including connecting up with twin core twisted flexible copper conductor cable, holders with suitable size, internal wiring of fittings , 230V, 50Hz, complete all as specified.\n 70 EACH
40 40 S & F in repair 1X18W LED PL-Lamp suited for installation in existing 2G11 lamp holders including connecting up with twin core twisted flexible copper conductor cable, holders with suitable size, internal wiring of fittings , 230V, 50Hz, complete all as specified.\n 100 EACH
41 41 Supply and fix in repair electronic ballast ( T8 FTL) suitable for 1x36 watt, all as specified and directed by Engr-in-Charge. 500 EACH
42 42 Supply and fix in repair flourocent tubelight for 1x36 watt. 500 EACH
43 43 Supply and fix in repair 20A SP/SPN plug and socket enclosure in sheet steel inclosures without SP/SPN MCB complete all as specified and directed. 5 EACH
44 44 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC Casing Caping not less then 20mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.\nNotes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing and one run of PVC casing/caping shall be measured as one unit. 70 RM
45 45 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC conduit not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.\nNotes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing and one run of PVC conduit shall be measured as one unit. 50 RM
46 46 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through and including PVC Conduit not less then 25mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.\nNotes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing and one run of PVC Conduit shall be measured as one unit. 50 RM
47 47 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through and including PVC casing capping not less then 32mm dia medium Grade fixed on walls / roof / floors all as directed by Engineer in Charge.\nNotes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing and one run of PVC casing capping shall be measured as one unit. 270 RM
48 48 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC Conduit not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.\nNotes:- Two wires of 6 sqmm and one wire of 6 sqmm and one run of PVC Conduit shall be measured as one unit. 50 RM
49 49 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC Casing Caping not less then 32mm dia medium Grade fixed on walls / roof / floors all as directed by Engineer in Charge.\nNotes:- Two wires of 6 sqmm and one wire of 6 sqmm and one run of PVC casing capping shall be measured as one unit. 260 RM
50 50 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through exsisting steel conduit any make and type fixed on walls/roof/floors all as directed by Engineer in Charge.\nNotes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing shall be measured as one unit. 50 RM
51 51 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through exsisting steel conduit any make and type fixed on walls / roof / floors all as directed by Engineer in Charge.\nNotes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing shall be measured as one unit. 50 RM
52 52 Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through exsisting steel conduit any make and type fixed on walls/roof/floors all as directed by Engineer in Charge.\nNotes:- Two wires of 6 sqmm and one wire of 6 sqmm for earthing shall be measured as one unit. 50 RM
53 53 S & F 4 way MCCB powerline vertical DBs in double door suitable for TP / FP MCCB, bus bar with current rating capacity upto 160A, IP-43-IK09 protection grade complete all as specified and directed by Engr-in-Charge, 2 Each
54 54 S & F in repair for MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415 Volts TPN with 4 way Double door including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed 2 EACH
55 55 S&F in repair Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 12 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed. 4 EACH
56 56 S & F in repair, MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail , 240Volts SPN with 8 way Double door , IP-43-IK09 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed 6 EACH
57 57 S & F in repair MCB DB made of sheet steel enclosures with detachable gland plates for flush/surface mounting with bus bars, neutral links and earth bar (without mcbs) , 240Volts SPN with 6 way Double door , IP-42 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed 4 EACH
58 58 S & F in repair MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 240 Volts SPN with 4 way Double door IP-43-IK09 protection grade including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed 4 EACH
59 59 Supply and fix in repair for MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps 2 EACH
60 60 Supply and fix in repair for MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps 4 EACH
61 61 Supply and fix in repair for MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 32-40 Amps 14 EACH
62 62 Supply and fix in repair for MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating 154 EACH
63 63 S & F in repair MCCB TPN 63 Amps , 415Volts, 25KA ,4 pole. 1 EACH
64 64 S & F in repair MCCB TPN 100Amps , 415Volts, 25KA ,4 pole. 1 EACH
65 65 Taking down and fixing partly unserviceable LED security light fittings (building) of any make and type for necessary repair including ractifing any kind of electronic disorder / Circuit disorder / replacement of LED strip / all other accessories and make it serviceable , complete all specified and directed by Engr-in-Charge.\nNote: (1) Ladder to be provided by contractor.\n (2) Spare i.e driver shall be measured seperately. 30 EACH
66 66 S & F in repair electronic driver 12 / 15 Watt suitable for security light fittings new generation energy saving and environmental friendly long life LED street light/building security light of any make and type, all as specified and directed by Engr-in-Charge. 30 EACH
67 67 Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in gound (Earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earht strip protected by provision of GI light grade pipe 15 mm light grade bore including provision of pit in PCC (1:2:4) type B-1 using 20 mm graded of stone aggregate with PCC cover including 20mm bore pipe for wetering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal (not less than 40 Kgs, 80 Kgs each) filling with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electircal plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. 4 EACH
68 68 NOTE :- AMOUNT OF SCHEDULE OF CREDIT RS. 38,315.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.