Military Engineer Services-MES has published Repair And Maintenance Of Internal Electrification , Acs , Geysers , Ceiling Fan , Refrigerator , Deep Freezers And Other Allied Works At Jakli Rtc Dhansal Under Ge Army Dhar Road. Submission Date for this Tender is 27-08-2020. Electrification Work Tenders in JAKLI DHANSAL under GE Army Dhar Road Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, ACs, GEYSERS, CEILING FAN, REFRIGERATOR, DEEP FREEZERS AND OTHER ALLIED WORKS AT JAKLI RTC DHANSAL UNDER GE ARMY DHAR ROAD | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. | 1320 | Point | |
2 | 2 | M & L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:- Make of wire-Havells/Finolex/Polycab and Make of pipe- plaza, kalinga, AKG | |||
3 | 2.1 | One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole. | 800 | Point | |
4 | 2.2 | One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. | 100 | Point | |
5 | 2.3 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. | 300 | Point | |
6 | 3 | All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. | 120 | Point | |
7 | 4 | S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed. Make : Anchor/Havells/Cona | 1185 | Each | |
8 | 5 | S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.Make : Anchor/Havells/Cona | 120 | Each | |
9 | 6 | S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed. Make : Anchor/Havells/Cona | 400 | Each | |
10 | 7 | S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed Make : Anchor/Havells/Cona | 120 | Each | |
11 | 8 | S&F bell push 5/6 Amps SP flush type complete all as specified and as directed. Make : Anchor/Havells/Cona | 15 | Each | |
12 | 9 | S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. Make : Anchor/Havells/Cona | 500 | Each | |
13 | 10 | S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed.Make : Anchor/Havells/Cona | 200 | Each | |
14 | 11 | S&F Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and as directed. Make : Anchor/Havells/Cona | 15 | Each | |
15 | 12 | Supply & Fixing medium step type fan regulator , 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed. \n make Cona / Anchor/Havells/Crabtree | 100 | Each | |
16 | 13 | M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in PVC rigid conduit not less than 20 mm dia ISI marked medium grade incl fitting like bends, elbow, junstion box, reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated and PVC conduit pipe with fitting shall be measured and paid as one unit length. Make of wire-Havells/Finolex/Polycab and Make of pipe- plaza, kalinga, AKG | 1200 | RM | |
17 | 14 | M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in PVC rigid conduit not less than 20 mm dia ISI marked medium grade incl fitting like bends, elbow, junstion box, reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated and PVC conduit pipe with fitting shall be measured and paid as one unit length. Make of wire-Havells/Finolex/Polycab and Make of Pipe Plaza, Kalinga, AKG | 1000 | RM | |
18 | 15 | S & F service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable with GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete. Make : Plaza /Polycab/Havells/finolex | 1000 | RM | |
19 | 16 | S & F service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable with GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete. Make : Plaza/Polycab/Havells/finolex | 1000 | RM | |
20 | 17 | Supply & Fixing in replacement of old unserviceavle DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed.\nCat No. 507610 of make legrand or equivalents of Schneider (Electric)/L & T . | 20 | Each | |
21 | 18 | Supply & Fixing in replacement of old unserviceable DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed.\nCat No. 507601 of make legrand or equivalents Schneider (Electric)/L & T . | 20 | Each | |
22 | 19 | Supply & Fixing in replacement of old unserviceable DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way, confirming to IS 13032 & 8623 complete all as specified and directed.\nCat No. 507602 of make legrand or equivalents Schneider (Electric)/L & T . | 10 | Each | |
23 | 20 | Supply and fixing in replacement of old unserviceable DB by TPN Distribution Box double door of protection grade IP 43, in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.\ncat no 507782 of make legrand or equivalents of Schneider Electric/L & T\n | 5 | Each | |
24 | 21 | Supply & fixing in replacement of AC box by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket complete with one single pole MCB, 240 volt, 20 Amps , 'C' series of suitable rating complete all as specified and directed . cat no 507811 of make legrand or equivalents of Schneider Electric/L & T. | 5 | Each | |
25 | 22 | Supply & Fixing MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. \nCat no 408617 of make legrand or equivalents of Schneider Electric/L & T | 50 | Each | |
26 | 23 | Supply & Fixing MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. \nCat no 408618 to 408620 of make legrand or equivalents of Schneider Electric/L & T | 25 | Each | |
27 | 24 | Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. \nCat no 408586 to 408595 of legrand or equivalents of Schneider Electric/L & T. | 200 | Each | |
28 | 25 | Supply only MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. \nCat no 408683 of legrand or equivalents of Schneider Electric/L & T. | 5 | Each | |
29 | 26 | S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling taking down unsv FTL fitting T8 type any type complete all as specified and directed. Make: Crompton Cat Part No LDL-20-CDL or equivalent in Philips/WIPRO | 300 | Each | |
30 | 27 | S&F Wall mounted Mirror light LED fitting, 10 Watt, 2 Feet long incl integrated electronic driver including dismantling taking down unsv sketch fitting any type complete all as specified and directed. Make: Crompton Cat Part No LDL-10-CDL or equivalent in Philips/wipro | 100 | Each | |
31 | 28 | S&F LED building security light 20 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. Make-CROMPTON cat no LST-20-CDL-M or equivalent in WIPRO/Philips | 50 | Each | |
32 | 29 | Supply only LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb. Make - Philips/wipro/Havells/crompton | 400 | Each | |
33 | 30 | Supply and fixing in replacement of Mirror optic fitting by recess mounted mirror optic LED luminaire fitting not less than 100 lumen/watt , 30 watt, dimention 600mm x 600mm fitting for grid type ceiling including control driver and other accessories complete all as specified and directed. cat no LCTLRNE-30-FO-CDL OF MAKE CROMPTON OR EQUIVALENTS OF Philips/wipro/Havells | 20 | Each | |
34 | 31 | Supply and fixing in replacement of Mirror optic fitting by Surface mounted mirror optic LED luminaire fitting not less than 100 lumen/watt , 30 watt, dimention 600mm x 600mm fitting for grid type ceiling including control driver and other accessories complete all as specified and directed. cat no LCTLSNE-30-FO-CDL OF MAKE CROMPTON OR EQUIVALENTS OF Philips/wipro/Havells | 12 | Each | |
35 | 32 | M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).\n | 40 | Each \nSet | |
36 | 33 | Ceiling & Exhaust Fan\nTaking down and refixing after recify the defects carefully of ceiling fan any size and any sweep including dismantling of blades, down rods fan for recognize defects at site or deposit to store complete all as directed by Engineer-in-Charge. | 100 | Each | |
37 | 34 | Taking down and refixing after recify the defects carefully of exhaust fan any size and any sweep including dismantling of blades, for recognize defects at site or deposit to store complete all as directed by Engineer-in-Charge. | 40 | Each | |
38 | 35 | Labour work for overhauling, opening and inspection of ceiling fan any Make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, sockets rebber real, clamps and minor repairing works and items etc. reassembling and testing on completion all as directed. Note :- Winding works will be taken seperatly . Other items will be measured and paid seperatly. | 100 | Each | |
39 | 36 | All as specified in item No.31 here-in-before but for exhaust fan/wall fan/fresh air fan etc of any Make and any size. | 40 | Each | |
40 | 37 | Painting of ceiling fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No ceiling fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed | 70 | Each | |
41 | 38 | Painting of Exhaust fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No Exhaust fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed | 20 | Each | |
42 | 39 | Removing the burnt copper winding of ceiling fan ,cleaning to cores and rewinding of ceiling fans with copper enameled wire of suitable size including film paper, sleaving and varnishing , 48” (1200mm) complete any make any type as directed by Engr-in- Charge . | 70 | Each | |
43 | 40 | All as per item No 7 above but exhaust fan 18” sweep 450mm complete any make all as directed by Engr-in- Charge | 15 | Each | |
44 | 41 | All as per item No 7 but exhaust fan 12” sweep(300 mm) dia complete | 10 | Each | |
45 | 42 | All as per item No but Wall fan 12'' /15" (300 mm/350 mm) dia complete | 10 | Each | |
46 | 43 | supply of ball bearing suitable size where required and as directed Make SKF/NBC :- | |||
47 | 43.1 | (a) 6201ZZ \n\n | 50 | Each | |
48 | 43.2 | (b) 6202ZZ | 50 | Each | |
49 | 43.3 | (c) 6203ZZ | 50 | Each | |
50 | 44 | supply of condensor 2.5 MFD where required and directed for ceiling fan | 100 | Each | |
51 | 45 | Supply of condensor 4.00 MFD for exhaust fan where reqd and directed | 30 | Each | |
52 | 46 | Supply of Gun metal bush where required as directed for ceiling fan or exhaust fan all as directed. | 10 | Each | |
53 | 47 | Renewal of shaft suitable for any make of ceiling fans and exhaust fans all as directed. | 10 | Each | |
54 | 48 | Replacement of existing ceiling fan down rod with medium grade galvanized iron/ stove enameled pipe 20mm / 15 mm dia including threading both side or MS conduit heavy duty including both end hole with clamp with rubber real and split pin cable entry hole and check nuts including 3 core copper conductor 23/76, PVC insulated wire complete all as specified and directed | 50 | RM | |
55 | 49 | VOLATAGE STABLIZER\nDismantling of voltage stabilizer 5/4 KVA capacity for repairs and re-fixing back to its original position after repair, cleaning, testing, complete all as directed ( Parts to be replaced will be measured and paid separately under relevant items ). | 12 | Each Job | |
56 | 50 | Supply only the following parts for voltage stabilizer 4/5 KVA capacity :- | |||
57 | 50.1 | (a) Main printed circuit board | 12 | Each | |
58 | 50.2 | (b) Auxilary printed board | 10 | Each | |
59 | 50.3 | (c ) Main transformer | 10 | Each | |
60 | 50.4 | (d) Auxilary transformer | 12 | Each | |
61 | 50.5 | (e) High/low cut off relay | 10 | Each | |
62 | 50.6 | (f) Time delay relay | 10 | Each | |
63 | 50.7 | (g) Volt meter 0-300 volt range AC round/square shape, | 10 | Each | |
64 | 50.8 | (h) Push button/switch for volt meter. | 10 | Each | |
65 | 50.9 | (j) Indicator lamp. | 10 | Each | |
66 | 51 | Geyser \nSupply and fixed heating element 1500 watt push/screw/ triangular type suitable for 25 ltrs capacity geysers ISI marked complete all as directed by Engr-in-Charge. | 25 | Each | |
67 | 52 | Supply and fixed thermostat switch suitable for 25/50 Ltrs capacity geyser of any make/ type with temperature range adjustable from 25 to 90 degree centigrade superior quality 20 Amp rating 220 volt AC supply complete. | 25 | Each | |
68 | 53 | Supply and fixed PVC flexible connection with two brass adopter as per existing samples/ suitable of carrying hot water fixed one end at geyser inlet / outlet water supply point complete . | 40 | Each | |
69 | 54 | Supply and fixing geyser 25 Ltrs inner tank copper moulded alongwith all connection complete all as specified and directed | 10 | Each | |
70 | 55 | Supply and fixing geyser assembly any type including packing and gasket materials as per existing any type 25/50 Ltrs Geyser all as specified and directed. | 10 | Each | |
71 | 56 | RO water purification \nRepair and maint of RO water purification system of any make complete with replacement of unserviceable parts and making the system serviceablr as per manufacturers accessories Note :- New parts will be measured and paid seperatly under respective item under supply only . labour charge will be deemed in quoted rate . | 10 | Each Job | |
72 | 56.1 | Supply only micro spun 20 Make Renuka RWI 107 | 10 | Each | |
73 | 56.2 | supply only CTO 20 Make Renuka RWI 109 | 10 | Each | |
74 | 56.3 | Supply only membrane housing 50 Make Renuka RWI 125 | 10 | Each | |
75 | 56.4 | Supply only UV system 100 Make Renuka RWI 137 | 10 | Each | |
76 | 56.5 | Supply only flow restrictor adjuster Make Renuka RWI 134 | 10 | Each | |
77 | 56.6 | Supply only micronic membrane 50 Make Renuka RWI 127 | 10 | Each | |
78 | 56.7 | Supply only connecting pipe PVC | 40 | RM | |
79 | 56.8 | Supply only sedimentation filter | 10 | Each | |
80 | 56.9 | Supply only Motor and pump for RO | 10 | Each | |
81 | 57 | Air Conditioner\nSupply and fixing in replacement of compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection and shall confirm to IS 10617, making all existing connection complete all as directed for 1.5/2.0 ton Window type/split type Air conditioners all as directed . | 5 | Each Job | |
82 | 58 | Charging of refrigerant Gas F 22/ R-134A in the sealed system of of Window type Air conditioners/split type ACs 1.5 /2Ton capacity after checking leakage /pressure vacumising flushing the sealed unit in satisfactory working condition all as specified. | 14 | Kg | |
83 | 59 | Taking down for servicing of window/Split AC 1.5 ton/2.0 Ton capacity and cleaning /serviceing of AC, overhauling of cooling coil, air filters/plasma filters etc (indoor ) condenssors , fan motors etc (outdoor unit) with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted. | 4 | Each | |
84 | 60 | Supply only the following defective spares parts of split /window AC unit of 1.5/2.00 TR against above item ;- | |||
85 | 60.1 | (a) Blower motor 1/6 HP with base/ rubber bush complete Make AUE/GE | 3 | Each | |
86 | 60.2 | (b) Condensor fan motor 1/5 HP make AUE/GE as per sample. | 3 | Each | |
87 | 60.3 | (c) Condensor fan blade. | 3 | Each | |
88 | 60.4 | (d) Drum type blower fan PVC type | 3 | Each | |
89 | 60.5 | (e) Running capacitor 36 mfd make EPCOS. | 3 | Each | |
90 | 60.6 | (f) Running capacitor 45 mfd make EPCOS. | 3 | Each | |
91 | 60.7 | (g) Starting capacitor 100 to 120 mf Make : "TESLA" | 2 | Each | |
92 | 60.8 | (h) Selector switch. | 2 | Each | |
93 | 60.9 | (j) Thermostate make Indfoss. | 2 | Each | |
94 | 60.91 | (k) Starting relay make Ranutrol. | 3 | Each | |
95 | 60.92 | (l) Cooling coil assembly. | 3 | Each | |
96 | 60.93 | (m) Condensor coil assembly. | 3 | Each | |
97 | 60.94 | (n) Wiring kit. | 3 | Each | |
98 | 60.95 | (o) Capacitor 6 mfd | 3 | Each | |
99 | 60.96 | (p) Blower motor 1/30 HP for in door unit split type AC. | 3 | Each | |
100 | 60.97 | q) Main printing circuit board (PCB) with electric accessores and sensors suitable for split AC cap 1.5/2 TR | 3 | Each | |
101 | 61 | M&L for detecting the leakage of gas of split/window type AC 1.5/2 TR from any location and rectified /stoped the leakage by gas weilding or any other materials and made it functioning as directed . | 3 | Each job | |
102 | 62 | WATER COOLERS\nDisconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from water cooler of any make ,replacing the defective compressor with repaired old serviceable compressor from any of the authorised repair workshop /manufacturer, refixing the repaired compressor in the original position of the water cooler making all existing connection for for any capacitiesas directed | 10 | Each Job | |
103 | 63 | Supply and fix in replacement of new compressor hermetically sealed type with suitable rated capacity electric motor and shall be equipped with over load protection, 230 volt, 50 HZ, single phase suitable for water cooler any capacity incl warrenty as per menufacturers | 4 | Each Job | |
104 | 64 | M&L for gas refrigent F-22/R-134A in the sealed system of water cooler any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capilary Tube, Gas filter all as directed. | 20 | Kg | |
105 | 65 | Dismantling and supply and fixing the blower moter of water cooler 1/32 HP, 1250 RPM capacity, 230 volts single phase and taking out burnt out copper winding wire from moter and M&L for rewinding the electric motor with super enameled copper winding wire of same size and gauge including insulation material, varnish and reassemble and refixing the motor complete including replacement of unserviceable spares all as directed. | 5 | Each Job | |
106 | 66 | Disconnection from mains for servicing of water cooler of cap upto 180 Ltrs and cleaning /serviceing , overhauling of cooling coil with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted. | 5 | Each Job | |
107 | 67 | Supply only the following defective spares parts of water cooler any cap against above item ;- | |||
108 | 67.1 | Supply of thermostat switch for water cooler. | 8 | Each | |
109 | 67.2 | Supply of starting relay for water cooler. | 6 | Each | |
110 | 67.3 | Supply of starting capacitor 40-60 mfd ,230 volt ,50Hz, confirming to IS 2993 for water cooler. | 6 | Each | |
111 | 67.4 | Supply of starting capacitor capacity 60-80 MFD. | 6 | Each | |
112 | 67.5 | Supply of Running capacitor 15 Mfd , 415volt,50Hz . | 6 | Each | |
113 | 67.6 | Supply of Running capacitor 10 Mfd , 415volt,50Hz . | 6 | Each | |
114 | 67.7 | Supply of Running capacitor 6 Mfd , 415volt,50Hz . | 6 | Each | |
115 | 67.8 | Supply of Running capacitor 36 Mfd , 415volt,50Hz . | 7 | Each | |
116 | 68 | Supply PVC float valve with rod and plastic ball suitable for 1/2" bore of watercooler for blue star fittings | 4 | Each | |
117 | 69 | Supply of over load protector (OLP) for water cooler of any capacity complete all as specified and directed. | 4 | Each | |
118 | 70 | Supply of self closing Push cock 15mm bore chromium plated brass heavy duty longthread ( As per sample). | 3 | Each | |
119 | 71 | Supply of aluminium blade for blower motor of water cooler 40/60/120 Ltrs | 3 | Each | |
120 | 72 | Supply blower motor 1/32 HP 230 volt suitable for water cooler complete with base frame/and rubber bush make AUE/GE. | 3 | Each | |
121 | 73 | Supply of water tank gasket for water cooler 40/80 ltr cap. | 3 | Each | |
122 | 74 | Supply of wiring kit complete for water cooler. | 3 | Each | |
123 | 75 | Supply of PVC pipe low density 25 mm dia flexible pipe with two clamp complete & all as specified. | 10 | RM | |
124 | 76 | Supply and fixing in replacement PVC connection pipe with brass union of 15 mm bore in both end suitable for water cooler connection of length not less than 600 mm long. | 6 | Each | |
125 | 77 | Supply and fixing PVC pipe flexible type 40 mm dia for drain system and connection all as directed. | 20 | RM | |
126 | 78 | Refrigerator /Deep Freezer\nDisconnection from mains for servicing of Refrigerator/Deep freezer of cap 165 to 310 Ltrs and cleaning /serviceing , overhauling of cooling coil with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted. | 10 | Each Job | |
127 | 79 | Supply only the following defective spares parts of Refrigerator/ Deep freezer any cap against above item ;- | |||
128 | 79.1 | Supply of thermostat switch | 5 | Each | |
129 | 79.2 | Supply of starting relay | 5 | Each | |
130 | 79.3 | Supply of starting capacitor 40-60 mfd ,230 volt ,50Hz, confirming to IS 2993 for water cooler. | 5 | Each | |
131 | 79.4 | Supply of Running capacitor 15 Mfd , 415volt,50Hz . | 8 | Each | |
132 | 79.5 | Copper filter single capillary pencile type | 8 | Each | |
133 | 80 | Disconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from water cooler of any make ,replacing the defective compressor with repaired old serviceable compressor from any of the authorised repair workshop /manufacturer, refixing the repaired compressor in the original position of the Refrigerator /Deep freezer making all existing connection for any capacities. | 5 | Each Job | |
134 | 81 | Supply and fix in replacement of new compressor hermetically sealed type with suitable rated capacity refrigerator of any make and type and providing and fixing new compressor suitable for 165 to 310 ltr refrigerator and testing the same with gurantee as per manufacturers incl charging of the refrigent gas F-12m R-134 A and all other copper tubes capillary and filter and put in working condition all as directed | 4 | Each Job | |
135 | 82 | M&L for gas refrigent F-22/R-134A in the sealed system of Refrigerator / Deep frezeer any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capilary Tube, Gas filter all as directed. | 12 | Kg |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy