Repairs Of External Electric Supply Installation , Water Supply Installation , Solar Lights System , Street Lights And Area Lighting And Internal Electrification , Ac Units And Essential Em Works At Shibpur, Port Blair-Andaman And Nicobar Islands

Military Engineer Services-MES has published Repairs Of External Electric Supply Installation , Water Supply Installation , Solar Lights System , Street Lights And Area Lighting And Internal Electrification , Ac Units And Essential Em Works At Shibpur. Submission Date for this Tender is 26-08-2020. Electrical Maintenance Tenders in Port Blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

25111986
Repairs Of External Electric Supply Installation , Water Supply Installation , Solar Lights System , Street Lights And Area Lighting And Internal Electrification , Ac Units And Essential Em Works At Shibpur
Open Tender
Indian
Andaman And Nicobar Islands
Port Blair
26-08-2020

Tender Details

Repairs Of External Electric Supply Installation , Water Supply Installation , Solar Lights System , Street Lights And Area Lighting And Internal Electrification , Ac Units And Essential Em Works At Shibpur

Key Value

Document Fees
INR 500 /-
EMD
INR 68000.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work: REPAIRS OF EXTERNAL ELECTRIC SUPPLY INSTALLATION, WATER SUPPLY INSTALLATION, SOLAR LIGHTS SYSTEM, STREET LIGHTS AND AREA LIGHTING AND INTERNAL ELECTRIFICATION, AC UNITS AND ESSENTIAL E&M WORKS AT SHIBPUR File No. 8803/E8
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep and getting it out in soft/loose soil including forming bottom surface to required level for laying pipes/ cables and water pipe lines all as specified and as directed. 270 Cubic Metre
2 2 Returning, filling in excavated soil including spreading, leveling, watering, well ramming in layers not exceeding 25cm all as specified and as directed. 210 Cubic Metre
3 3 Removing the surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above starting point all as specified and as directed. 60 Cubic Metre
4 4 Disconnecting and taking down the existing burnt out LT UG cable of size 2 x 6 Sqmm. 100 Running Metre
5 5 Disconnecting and taking down the existing burnt out LT UG cable of size 2 x 10 Sqmm. 100 Running Metre
6 6 Disconnecting and taking down the existing burnt out LT UG cable of size 3.5x 35 Sqmm. 100 Running Metre
7 7 Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 x 50 Sqmm. 100 Running Metre
8 8 Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 x 70 Sqmm. 150 Running Metre
9 9 Disconnecting and taking down the existing burnt out LT UG cable of size 3.5 x 95 Sqmm. 80 Running Metre
10 10 Supply, lay and testing XLPE insulated, extruded, PVC outersheathed and innersheated galvanised steel, armoured heavy duty LT UG electric cable with aluminium conductor, 1100 Volts grade, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 2 core 6 Sqmm all as specified and as directed. 100 Running Metre
11 11 Supply, lay and testing XLPE insulated, extruded, PVC outersheathed and innersheated galvanised steel, armoured heavy duty LT UG electric cable with aluminium conductor, 1100 Volts grade, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 2 core 10 Sqmm all as specified and as directed. 100 Running Metre
12 12 Supply, lay and testing XLPE insulated, extruded, PVC outersheathed and innersheated galvanised steel, armoured heavy duty LT UG electric cable with aluminium conductor, 1100 Volts grade, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 35 Sqmm all as specified and as directed. 100 Running Metre
13 13 Supply, lay and testing XLPE insulated, extruded, PVC outersheathed and innersheated galvanised steel, armoured heavy duty LT UG electric cable with aluminium conductor, 1100 Volts grade, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 50 Sqmm all as specified and as directed. 100 Running Metre
14 14 Supply, lay and testing XLPE insulated, extruded, PVC outersheathed and innersheated galvanised steel, armoured heavy duty LT UG electric cable with aluminium conductor, 1100 Volts grade, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 70 Sqmm all as specified and as directed. 150 Running Metre
15 15 Supply, lay and testing XLPE insulated, extruded, PVC outersheathed and innersheated galvanised steel, armoured heavy duty LT UG electric cable with aluminium conductor, 1100 Volts grade, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.5 core 95 Sqmm all as specified and as directed. 80 Running Metre
16 16 S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 25 to 50 Sqmm, indoor/ outdoor type. all as specified and as directed. 3 Each
17 17 S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 70 to 95 Sqmm, outdoor type all as specified and as directed.. 3 Each
18 18 Supply and laying of DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 50mm and inner dia 38mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed. Make: Telerex 300 Running Metre
19 19 Supply and laying of DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 90mm and inner dia 76mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed. 250 Running Metre
20 20 Supply and laying of DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 145mm and inner dia 126mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed. 80 Running Metre
21 21 M&L for painting of street light poles, by removing of old paint and applying one coat of red oxide metal primer and two coats of approved aluminium paint to steel tubular swaged pole, cross arm and service brackets complete all as specified and directed. 20 Each Job
22 22 Taking down LED street light fittings for repair/ replacement of burnt / worn out accessories and refixing the same after all repair work complete.\nNote: Spares shall be measured and paid separately. 10 Each
23 23 S&F new generation energy saving and environmental friendly 45 Watts street light fitting long life versatile pressure die cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver, including taking down old light fitting complete all as specified and directed. Make: Crompton Cat No LSTS-45-CDL or equivalent in Bajaj/ Wipro/ Philips. 10 Each
24 24 S&F driver suitable for 40 Watt LEDs security light fitting long life versatile pressure die cast aluminium IP66 road, including taking down old driver complete all as specified and directed. 6 Each
25 25 S&F driver suitable forn 45 Watt LEDs street light fitting long life versatile pressure die cast aluminium IP66 road, including taking down old driver complete all as specified and directed. 6 Each
26 26 Servicing of solar power generating PV modules for security lighting system, mounted on poles of approx height 5.0M, by cleaning the photo voltaic panel using soft cloth and cleaning agent, adjusting to the proper direction, replacing only the defective parts/components required will be measured and paid separately under relevant items as "supply only", and preparation of old painted surfaces of Galvanized iron pole of solar power generating system, approx 5.0 metres long and painting with two coats of aluminium paint on poles and on all iron surfaces/ steel surfaces complete all as specified. 7 Each Job
27 27 Supply only tubular acid lead battery 12V, 100 AH, Make: EXIDE 'OR' equivalent in TATA solar power suitable for existing solar power modules of make "Crompton". 5 Each
28 28 Supply only PVC insulated copper cable, 3 core of size 1.50 Sqmm. Make: Finolex/ Havells/ Standard suitable for existing solar power modules of make: "Crompton". 30 Running Metre
29 29 S&F to existing 24 Watts LED based solar street lighting system in built Dusk to Dawn MPPT type electronic charge controller with inverter circuit, over charging/ over current/ under voltage protection suitable for 24 W solar LED light fitting. 2 Each
30 30 Supply, fixing, connecting and testing ON LOAD change over switch, 4 pole, 415 Volt, AC, with SS enclosure, side handle operated including necessary electrical connection of 400 Amps capacity complete all as specified and directed. 1 Each
31 31 S&F double door compression copper stainless steel gland for fixing armoured cable of size 25 to 35 Sqmm. 5 Each
32 32 M&L for GI pipe light grade 50mm dia from ground to street light Junction box including fixing with suitable size of clamps, nut and bolts on RCC poles complete all as specified and directed. 40 Running Metre
33 33 M&L for wiring with 1100 volt grade, 2 runs of 1.50 Sqmm single core FRLS PVC insulated unsheathed multi stranded copper conductor cable drawn through rigid PVC conduit from street light in box/ looping box to street light fitting along with 1.5 sqmm single core FRLS PVC multi stranded copper conductor cable green in colour as continuous earth wire complete all as specified and as directed. 135 Running Metre
34 34 M&L for earthing complete with galvanised steel earth plate electrod 60cm x 60cm x 6mm thick buried directly in ground (each pit not less than 2.25 mtr below ground level) with Top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of galvanised earth strip 32x6 mm connected by means of bolts, nuts, check nuts and washers of galvanised iron steel, provision of 40mm dia GI pipes medium grade for earth wire protection connected from earth plate electrode to main switch board, provision of 15 mm dia GI pipe perforated medium grade for watering arrangement and PCC 1:3:6 type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 for earth pit. Cover with 6 No's 8 mm dia high strength deformed steel TMT bars on both ways, including test terminal block made of gun metal or phosphorous bronze 75x75x25 mm and drilled and screwed including 3 nos 8 mm dia, 25 mm long at hex head screw also necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance not exceeding 50 mtr, provision of char coal and salt complete all as shown in electrical plate No. 3 of schedule Part-I 2009 all as specified, directed and Testing on completion. 6 Each Set
35 35 Disconnecting and taking down the old unserviceable MCCBs / MCBs from existing Feeder pillar box. 5 Each
36 36 S&F MCCB TPN 250 Amp, 415 Volt, 4 pole, 16 kA, rating complete all as specified and directed. 1 Each
37 37 S&F MCCB TPN 125 Amp, 415 Volt, 4 pole, 16 kA, rating complete all as specified and directed. 2 Each
38 38 S&F MCCB TPN 250 Amp, 415 Volt, 4 pole, 16 kA, rating complete all as specified and directed. 1 Each
39 39 S&F MCCB TPN 400 Amp, 415 Volt, 4 pole, 25 kA, rating complete all as specified and directed. 1 Each
40 40 S&F LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 139 x 119 x 70mm (internal dimensions) comprising aluminium busbar of adequate capacity and MCB SP 6 Amps, 10 kA - 01 No, Bakelite base neutral link, and 01 no earthing terminal bolt and nut and connecting up with 2 runs of PVC sheathed cable, multistranded of size 2.5 sq mm in GI tubing 15 mm light grade with aluminium terminal lugs including suitable size MS clamps, all as directed. 8 Each
41 41 S&F post top fitting LED type of size 1x10 Watts with IP 65 protection, resistant to impact and corrosion, moon light effect and efficient light distribution complete all as specified and directed. Make: Crompton Cat No. LBLSN-10-CDL or equivalent in Bajaj / Havells 10 Each
42 42 M&L PCC 1:2:4, type B1 (using 20 mm graded crushed granite stone aggregate) as in coping complete all as specified and directed. 1 Cubic Metre
43 43 M&L PCC 1:2:4, type B2 (using 40 mm graded crushed granite stone aggregate) as in foundation filling mass concrete complete all as specified and directed. 1 Cubic Metre
44 44 S&F flood light 150 Watts LED type energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting complete all as specified and directed. 3 Each
45 45 S&F street Light fitting GI bracket suitable for fixing of street light fitting by fabricating the size of 32mm dia Light grade GI pipe of length 1.5 mtr and suitable bend complete all as specified and directed by Engineer in charge. 6 Each
46 46 S&F LED Bollard Light of system wattage 1x14 watt with IP 65 protection of neutral white colour in die cast housing and Polycarbonate diffuser cover on base plate mounting with operating voltage 140-270 V, AC, 50 Hz, complete all as specified and directed. Make: Philips Cat No: City cube bollard P BCP400 LED 05 P CW PSU GR S1OR equivalent to Bajaj/ LG. 6 Each
47 47 Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 20 dia mm all as specified and as directed. 160 Running Metre
48 48 Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 25 dia mm all as specified and as directed. 100 Running Metre
49 49 Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 40 dia mm all as specified and as directed. 100 Running Metre
50 50 Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 50 dia mm all as specified and as directed. 100 Running Metre
51 51 Taking up or down steel tubing and connections, including cleaning for refixing or removal of size 80 dia mm all as specified and as directed. 80 Running Metre
52 52 S&F 20 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed. 160 Running Metre
53 53 S&F 25 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed. 100 Running Metre
54 54 S&F 40 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed. 100 Running Metre
55 55 S&F 50 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed. 100 Running Metre
56 56 S&F 80 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground all as specified and directed. 80 Running Metre
57 57 S&F 20 mm bore dia. Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve all as specified and directed. 8 Each
58 58 S&F 25 mm bore dia. Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve all as specified and directed. 4 Each
59 59 S&F 40 mm bore dia. Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve all as specified and directed. 3 Each
60 60 S&F 50 mm bore dia. Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve all as specified and directed. 3 Each
61 61 S&F 20 mm bore PTMT ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed of following sizes including taking down existing old ball valve all as specified and directed. 10 Each
62 62 S&F 25 mm bore PTMT ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed of following sizes including taking down existing old ball valve all as specified and directed. 10 Each
63 63 Taking down existing pipes and fittings and refixing 20 mm bore dia old steel tubing and connections in new or old position (walls, ceiling, floors etc) complete all as specified. 60 Running Metre
64 64 Taking down existing pipes and fittings and refixing 25 mm bore dia old steel tubing and connections in new or old position (walls, ceiling, floors etc) complete all as specified. 80 Running Metre
65 65 Taking down existing pipes and fittings and refixing 40 mm bore dia old steel tubing and connections in new or old position (walls, ceiling, floors etc) complete all as specified. 40 Running Metre
66 66 M&L for cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes of tank capacity 500 ltrs complete all as specified. 10 Each Job
67 67 M&L for cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes of tank capacity 1000 ltrs complete all as specified. 10 Each Job
68 68 M&L for cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes of tank capacity 2000 ltrs complete all as specified. 2 Each Job
69 69 Cleaning of semi underground water storage sump of capacity not exceeding 20000 ltrs by removing mud, silt, cutting of grass and roots and pumping out waste water, spreading bleaching powder, drying of tank and refilling fresh water including repairs to the opening door and outside painting to semi UG Sump as per existing colour scheme complete all as directed.\n 2 Each Job
70 70 S&F brass foot valve of size 50mm including removing the existing unserviceable foot valve all as specified and as directed.\n 2 Each
71 71 S&F Rotational moulded polyethylene three layered Water storage Tank of capacity 500 Ltr (Cylindrical Vertical with closed top) hoisted and fixed in position all as specified and directed. \n 2 Each
72 72 S&F Rotational moulded polyethylene three layered Water storage Tank of capacity 1000 Ltr (Cylindrical Vertical with closed top) hoisted and fixed in position all as specified and directed. \n 2 Each
73 73 S&F Rotational moulded polyethylene three layered Water storage Tank of capacity 2000 Ltr (Cylindrical Vertical with closed top) hoisted and fixed in position all as specified and directed. \n 2 Each
74 74 Supplying and laying of Cast iron Pipes of 100 mm bore with spigot and socket ends centrifugally cast. Class LA, in any length, laid in trenches complete all as specified.\n 25 Running Metre
75 75 M&L fittings for CI pipe like bends (any type, radius and angle) Tees any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces, angle branch "Y" junction, double branch (all socket or socket and spigot) Collars, caps, end plug of size upto 150 mm bore. 150 Kilogram
76 76 S&F of Cast iron Sluice valve 100mm dia ISI marked class PN 1.6 both ends flanged complete with iron wheel head and brass spindle including flange joints, nuts, bolts, washers and 3mm rubber gasket etc, complete all as specified. 2 Each
77 77 M&L for Run Lead joint for Pipe of size 100 mm dia all as specified and directed. 5 Each
78 78 Supplying and Laying of CPVC Pipes SDR 11 & plain CPVC SDR 11 fittings in trenches of 50mm outer dia complete all as specified. 30 Running Metre
79 79 Supplying and Laying of CPVC Pipes SDR 11 & plain CPVC SDR 11 fittings in trenches of 40mm outer dia complete all as specified. 30 Running Metre
80 80 Supplying and Laying of CPVC Pipes SDR 11 & plain CPVC SDR 11 fittings in trenches of 45mm outer dia complete all as specified. 30 Running Metre
81 81 Construction of masonry valve chamber, 100 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:4, 15mm thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth without using extra cement, 3.15mm thick MS sheet cover including 50mm x 50mm x 6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mm x 6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as specified and shown on drawing for internal size 600 x 600 x 600mm. 1 Each Job
82 82 Disconnecting and taking down carefully old unserviceable point wiring of any size of copper/ Aluminum (light/ fan / sockets/ power) complete with switches, sockets, ceiling roses, lamp holders, brackets, other fittings and fixtures connected, removing material and making good to disturbed surfaces as directed by Engineer-in-Charge. 196 Each Point
83 83 M&L for Point wiring with 1.50 Sq mm (Nominal area) PVC insulated multi stranded copper conductor FRLS 1100 volts grade single core in PVC casing and capping on wall/ roof/ floor including PVC terminal boxes ISI marked duly fabricated, mounting on the wall for mounting switches, switch/ socket combinations, fan regulators etc with earth wire complete with 1.50 Sq mm (Nominal area) PVC insulated multi stranded copper conductor green in colour for One light point / fan point controlled by one switch all as directed. 120 Each Point
84 84 M&L for Point wiring with 1.50 Sq mm (Nominal area) PVC insulated multi stranded copper conductor FRLS 1100 volts grade single core in PVC casing and capping on wall/ roof/ floor including PVC terminal boxes ISI marked duly fabricated, mounting on the wall for mounting switches, switch/ socket combinations, fan regulators etc with earth wire complete with 1.50 Sq mm (Nominal area) PVC insulated multi stranded copper conductor green in colour for One three pin socket outlet 5 Amps on the same board. 20 Each Point
85 85 M&L for Point wiring with 1.50 Sq mm (Nominal area) PVC insulated multi stranded copper conductor FRLS 1100 volts grade single core in PVC casing and capping on wall/ roof/ floor including PVC terminal boxes ISI marked duly fabricated, mounting on the wall for mounting switches, switch/ socket combinations, fan regulators etc with earth wire complete with 1.50 Sq mm (Nominal area) PVC insulated multi stranded copper conductor green in colour for One three pin socket outlet 5 Amps on the independent board. 6 Each Point
86 86 M&L for Point wiring with 2.50 Sq mm (Nominal area) PVC insulated multi stranded copper conductor FRLS 1100 volts grade single core in PVC casing and capping on wall/ roof/ floor including PVC terminal boxes ISI marked duly fabricated, mounting on the wall for mounting switches, switch/ socket combinations, fan regulators etc with earth wire complete with 4.00 Sq mm (Nominal area) PVC insulated multi stranded copper conductor green in colour for One three pin socket outlet 16 Amps on the independent board. 50 Each Point
87 87 S&F in repair socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. 26 Each
88 88 S&F in repair of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge. 50 Each
89 89 S&F in repair switch piano flush type 5/6 amps single pole one way all as specified. Make : Anchor Penta/ Havells Reo 146 Each
90 90 S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and directed. 50 Each
91 91 S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. 100 Each
92 92 M & L for lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed. 20 Each
93 93 Taking down sub main wiring of any type complete all as specified and directed. 220 Running Metre
94 94 M&L for sub main wiring with 3 run of 4.00 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. NOTE : (i) Three run of submain wiring cable alongwith 25 mm dia PVC conduit pipe shall be measured as one unit length. 120 Running Metre
95 95 M&L for sub main wiring with 3 run of 2.50 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. NOTE : (i) Three run of submain wiring cable alongwith 25 mm dia PVC conduit pipe shall be measured as one unit length. 100 Running Metre
96 96 Taking down old MCB DBs with MCBs/Main switches/wooden boards etc complete all specified and directed. 6 Each
97 97 S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs / lsolators with and including blanking plates complete all as specified and as directed. 2 Each
98 98 S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs / lsolators with and including blanking plates complete all as specified and as directed. 1 Each
99 99 S&F Sheet metal enclosure for 12 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs / lsolators with and including blanking plates complete all as specified and as directed. 1 Each
100 100 S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs / lsolators with and including blanking plates complete all as specified and as directed. 2 Each
101 101 S&F of MCB, Single pole and neutral 40 Amps, 240 volts, ‘C’ curve, 10KA all complete as specified and as directed. 10 Each
102 102 S&F MCB, Single pole, 5 to 32 Amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed. Make: Havells DHMGBSPF06-32 or Equivalent Make 20 Each
103 103 S&F MCB TPN 63 Amps, 415 Volt, 10 KA, 'C' Curve rating, complete all as specified and directed. 5 Each
104 104 S&F MCB TPN 40 Amps, 415 Volt, 10 KA, 'C' Curve rating, complete all as specified and directed. 5 Each
105 105 M&L in replacement of Earthing complete with galvanised steel plate electrode of size 60cmx60cmx6.30mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4 mm dia earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15mm bore (Light grade) for building LT wall panel all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soilwith and including taking down the old one complete all as shown in electrical plate No 3 of SSR Part I 2009 including testing on completion all as specified and directed. Note: The Rate for Taking down the old unserviceable Earthing shall be deemed to be included in the unit rate. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.50 mtr length shall be deemed to be included in the rate quoted for this item. 4 Each Set
106 106 S&F (in repair) Bell Ding dong AC 230 Volt complete all as specified 3 Each
107 107 S & F in repair/replacement energy efficient surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed. Make: Havells Cat No. ENDURALINEARNEOBS20WLED840SPCWH or equal to Bajaj/Wipro/Crompton. 60 Each
108 108 S & F in repair/replacement energy efficient LED linear 10 Watt fitting with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed. Make: Havells Cat No : NAKSHATRA/10W/W or equivalent in Bajaj/Crompton. 20 Each
109 109 S & F in repair/replacement energy efficient LED fitting 12 Watt Square in circle theme ceiling merging with luminaire. Make:Crompton Cat No : LCDRQ-12-CDL or equivalent in Bajaj/Philips 4 Each
110 110 S & F in repair/replacement energy efficient LED fitting 12 Watt Circular shape ceiling merging with luminaire. Make: Crompton Cat No :CDR-216-30-57-SL-NWH or equivalent in Bajaj/Philips 4 Each
111 111 S & F in repair/replacement energy efficient LED 2 ' X 2 ' fitting 30 Watt with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old light fitting complete all as specified and as directed. Make: Crompton Cat No : LCTLRP-30-FO-CDL or equivalent in Bajaj/Crompton. 8 Each
112 112 S & F in repair/replacement energy efficient LED 4' X 1 ' fitting 40 Watt with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old light fitting complete all as specified and as directed. Make:Crompton Cat No : LCTLRN-40-CDL-(1X4) 2 Each
113 113 S&F of Flame proof light fitting LED type 20 Watt complete with LED tube and all accessories all as specified. Make: Crompton Cat No : EXTN2LT8-16/20) 2 Each
114 114 S & F LED Lamp 1 X 09 Watts retrofit type Make Surya or equivalent 30 Each
115 115 Disconnecting of electric connection from ceiling rose and taking down the ceiling/exhaust fan any type sweep for carrying out repairs / rewinding/ replacement/cleaning etc and refixing the same in position after repairs incl fixing/ labour only for replacement of unserviceable parts , greasing, oiling etc and replacement of minor rubber parts, connectors, bolts, nuts etc including replacing of unserviceable flexible connection wire etc upto 1 metre length complete all as specified. \nNote :- The new parts required shall be supply only under relevant items herein after and shall be measured and paid separately) A BOO shall be conveyed for find out defective spares after opening the forms.\n 30 Each
116 116 M & L for rewinding of coils of ceiling fan of any make and sweep by following ways:- (i) Taking out complete coils from the rotor of ceiling fan (ii) Rewinding of ceiling fans of any sweep by using super enameled copper wire and turns as per existing gauge and approved quality including insulation paper ,varnishing, drying and refitting the ceiling fan and testing the speed complete all as directed as per Engr-in-Charge. 25 Each
117 117 Description all as per Item No.116, but of exhaust fan of sweep 250 mm to 450 mm complete all as specified. 10 Each
118 118 Supply only Gun metal bush bearing parts/components of ceiling fan as per existing make and size complete all as specified and as directed. (Note : Parts and components supplied under this item shall be fixed under items herein before) for 15 Each Set
119 119 Description all as per Item No. 118, but Ball bearing (Make : NBC/SKF/ABC/ANT) 30 Each
120 120 Description all as per Item No. 118, but Paper condenser 2.5 MFD (Make : USHA/SHARITTA/KELTRON /UNIVERSAL). 20 Each
121 121 Description all as per Item No. 118, but Paper condenser 3.0 MFD (Make : USHA/SHARITTA/KELTRON /UNIVERSAL). 5 Each
122 122 S&F (in repair) step type electronic fan regulator, AC, 230 volt complete all as specified 20 Each
123 123 Supply only Gun metal bush bearing parts/components of exhaust fan of existing make and size complete all as specified and as directed. 8 Each Set
124 124 Description all as per Item No. 123, but Ball bearing (Make : NBC/SKF/ARC/ANT) 10 Each
125 125 Description all as per Item No. 123, but Paper condenser 4 MFD (Make : USHA/SARDA/KELTRON/UNIVERSAL). 8 Each
126 126 Taking down the existing unserviceable storage type electric water heater (geyser)of any make/ capacity, installed at different location including disconnecting, taking down opening all parts/accessories for inspection, cleaning, descaling, refixing serviceable parts, replacing unserviceable parts installed at old location and reconnection, testing complete all as directed by Engineer-in-Charge for the following capacity :- 25 Ltr capacity 2 Each
127 127 Supply only heating element round type of geysers including rubber washer for the following capacity (Make : Racold / Bajaj) of 1500 Watt capacity 1 Each
128 128 Description all as per Item No.127, but 2000 Watt capacity 1 Each
129 129 Supply only PVC connection pipe with brass unions at both ends, 450mm long 15mm bore (for incoming cold water) all as specified and as directed. 2 Each
130 130 Supply only chromium plated copper connection pipe 450mm long with two brass adopters washers and connecting up complete all as specified and directed. 1 Each
131 131 Supply only apparatus plate suitable for 25 ltrs capacity geyser. (Make : Bajaj/Racold) 1 Each
132 132 Supply only thermostat (ISI Marked) for 25 Liters capacity Geyser. (Make: Elcon or Equivalent ISI marked) 1 Each
133 133 S&F Non-return valve, ISI marked, brass, 15mm bore after taking out defective/ unserviceable one complete all as specified and directed (Make : ZOLOTO/TATA/SCUD) 1 Each
134 134 S&F in replacement hole fastener 10 mm dia, 100 mm long including nut and washer complete all as specified. 1 Each
135 135 S&F in replacement rubber gas Kit suitable for 25 ltrs capacity geyser (as per sample) complete all as specified. 1 Each
136 136 Supply and fixing in repair/replacement Three phase Static Energy Meter of accuracy class 1.0,3 X 240 V 50 Hz with backlit LCD display, of rating , 10-60A, Box complete (Measures and display KWH, Volt, VI, KW, PF , HZ, Last month history of KWH and MD in KW with special features like TOD, tamper logging, optical communication port and display in absence of power Make-HPL Cat No TPPB1521130000ME01 1 Each
137 137 Supply and fixing in repair/replacement Single phase Static Energy Meter of accuracy class 1.0,1 X 240 V 50 Hz with backlit LCD display, Optical port and RS 234 port display of rating 5 to 30 amp with DMLS compliance as per IS 15959 of rating , 10-60A, 240 V, Box complete (Measures and display KWH, Volt, VI, KW, KVA, PF , HZ, Six month history of KWH and MD in KW with special features like TOD, tamper logging, optical communication port and display in absence of power. Make-HPL Cat No TPPB1521130000ME01 2 Each
138 138 WATER COOLERS \nTaking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R 134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of the following capacity water coolers (a) 40/80 Ltrs 3 Each
139 139 M&L for cleaning including cleaning the system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vaccumising, charging of R-12/R-22 gas, replacement of copper pipe, copper strainer, topping up compressor oil, testing & commissioning the water coolers of the following capacity :- (a) 40/80 Ltrs 2 Each
140 140 Supply and fix in replacement relay assembly suitable for water cooler of any capacity as per existing complete all as specified. (Make : Sriram/Sarada) 2 Each
141 141 Supply and fix in replacement thermostatic switch suitable for water cooler of any capacity as per existing complete all as specified. (Make :INDOFOSS/RANUTROL) 3 Each
142 142 Supply and fix in replacement capacitor suitable for water cooler of any capacity as per existing complete all as specified. (Make : SARADA/UNISTAR) 3 Each
143 143 Supply and fix in replacement overload protector suitable for water cooler of any capacity as per existing complete all as specified. (Make : SRIRAM/KIRLOSKAR) 2 Each
144 144 Supply and fix in replacement fan motor with fiber blade suitable for water cooler of any capacity complete all as specified. (Make : AUF/FREEFLOW) 2 Each
145 145 S&F in replacement PVC hose connections, for water out let pipes including fixing by proper clips complete all as specified. 2 Running Metre
146 146 S&F in replacement PVC float valve of 15mm bore (including ball)suitable for water cooler of any capacity as per existing complete all as specified. 2 Each
147 147 Supply and fix in replacement capillary tube 1/32" including brazing for water cooler of any capacity complete all as specified. 10 Running Metre
148 148 Supply and fix in replacement wiring kit for water cooler of any capacity complete all as specified. 1 Each
149 149 S&F inlet in replacement PVC water connection as main inlet connection suitable for water cooler of any capacity as per existing complete all as specified. 1 Each
150 150 S&F in replacement inlet /outlet rubber pipe suitable for water cooler size 1/2" complete all as specified. 5 Running Metre
151 151 REFRIGERATORS\nTaking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of the following capacity water coolers :- Make-LG/WHIRLPOOL/USHA(TECUMSHA) (a) 320 Ltr 1 Each
152 152 M&L for gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vaccumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil, including to and fro transportation of the unit to the work shop testing & commissioning the refrigerators of the following capacity (a) 165 to 210 Ltrs 1 Each
153 153 Supply and fix in replacement relay suitable for Refrigerator / deep freezer of any capacity as per existing model complete all as specified. (Make : Sriram/Indfoss/ Danfoss) 1 Each
154 154 Supply and fix in replacement overload protector suitable for Refrigerator/deep freezer of any capacity as per existing model complete all as specified. 1 Each
155 155 Supply and fix in replacement thermostatic switch of auto de-frost suitable for refrigerator any type and capacity and any model complete all as specified. 1 Each
156 156 SPLIT TYPE ACs\nCarrying out leak test on all joints of the tubing of ACs of any capacity by pressurizing the system by dry nitrogen gas, carrying out air purging by vacuum pumps, checking any leak with soap water and recharging with fresh refrigerant gas, testing and commissioning of ACs as per manufacturer's manual and as directed by Engineer-in-charge. 12 Each job
157 157 Taking down the AC unit of any capacity by disconnecting all electrical and piping connections and performing following maintenance tasks.\n(a) Removal of dust from the outer body with the help of a blower.\n(b) Cleaning the condenser coils with water and cleaning agent/soap solution and descaling it.\n(c) Painting the base tray with one coat of black enameled paint.\n(d) Cleaning of air filter of with vacuum cleaner or washing the filter in lukewarm water with detergent.\n(e) Cleaning of anti allergy and triple filter and drying the filter in direct sunlight for 2 hrs.\n(f) Cleaning of plasma filter with vacuum cleaner or washing the filter in lukewarm water with detergent and drying the filter in shade.\n(g) Cleaning of micro protection filter with vacuum cleaner only.\n(h) Cleaning of indoor unit with a soft, dry cotton cloth.\n(j) Checking all connections including functioning of relays, capacitors, overload protectors, thermostats, industrial socket (Metal clad) and circuit breaker.\n 12 Each Job
158 158 Taking down the AC Unit of any capacity (both indoor & outdoor units) by disconnecting electrical connections and piping, shifting to new location and reinstalling with necessary additions/alterations, fittings and fixtures, making good the disturbed surfaces complete all as directed by Engineer In Charge. 10 Each
159 159 S & F Copper pipe line heavy duty upto 5/8" dia with puff insulation and flair nuts from indoor to outdoor Split Type AC of 1.5/2 TR Capacity all as specified and directed by Engineer In Charge. 120 Running Metre
160 160 S&F (in repairs) of capacitor (confoming to IS:2993-1975) AC 230 Volts in plastic container 45/4.0 mfd all as specified and as directed. 12 Each
161 161 S&F (in repairs) of capacitor (confoming to IS:2993-1975) AC 230 Volts in plastic container 55/6.0 mfd all as specified and as directed. 12 Each
162 162 S&F (in repairs) condenser unit complete set suitable for 1.5 Ton split type AC unit including removing the existing unit complete all as specified. 8 Each
163 163 S&F(in repairs) Fan blade suitable for 1.5 Ton split AC all as specified and as directed \n 8 Each
164 164 S&F(in repairs) blower motor capacitor 6 MFD all as specified and as directed 8 Each
165 165 Repair/Replacement of remote control unit along with remote control holder suitable for Split type ACs complete all as directed and as per manufacturer's specifications. 6 Each
166 166 S&F in replacement of new swing motor as per existing Model/Make for split type AC 1.5/2 TR complete all as specified and directed by Engineer-in-charge. 6 Each
167 167 S&F in replacement of 3 core copper PVC insulated wire of size 70/.0076 complete all as specified and directed by Engineer-in-charge. 150 Running Metre
168 168 Disconnecting and taking down burnt compressor of capacity 1.5 TR from split AC unit and supply and install the new compressor 1.5 TR capacity duly filled with gas as per existing model and size and testing also complete all as specified and directed by Engineer-in-charge, Make:-LG / Voltas Note:- (1) Guarantee card with original purchase voucher of the original manufacturer shall be produced before payment.(2) Freon Gas measured and paid separately under the relevant item of Sch 'A' all as specified and directed by Engineer-in-Charge. 6 Each
169 169 All as per item No. 168 above, but split type AC 2 TR capacity complete all as specified and directed by Engineer in charge. 2 Each
170 170 S&F Voltage Stabilizer 4 KVA, 170-270 Volts, Model No: VG-400 suitable for 1.5 Ton split AC all as specified and as directed. Make: V-Guard. 1 Each
171 171 S&F Voltage Stabilizer 5 KVA, 170-270 Volt, Model No: VG-500 suitable for 1.5 Ton split AC all as specified and as directed Make: V-Guard. \n 1 Each
172 172 S&F Voltage Stabilizer 2 KVA, 150-280 Volt, Model No: VG-150 suitable for 40/80 Ltrs capacity of water cooler all as specified and as directed. Make: V-Guard. \n 2 Each
173 173 S&F of AC fixing bracket suitable for 2/1.5 Ton split AC all as specified and as directed. 5 Each set
174 174 S&F(in repairs) PCB Board suitable for 1.5 Ton split AC all as specified and as directed.\n 1 Each
175 175 S&F (in repairs) Remote sensor Board suitable for 1.5 Ton split AC all as specified and as directed.\n 2 Each
176 176 Supply & Charging of refrigerant gas R-22 in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed (Make : Mafron/Floron) 40 Kilogram
177 177 Supply & Charging of refrigerant gas R-134A in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed (Make : Mafron/Floron) 40 Kilogram
178 178 Supply & Charging of refrigerant gas R-32 in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed (Make : Mafron/Floron) 40 Kilogram
Disclaimer :