Providinglift Irrigation Scheme Jaree Bradha In Tehsil Bhunter Distt. Kullu H.P. (Sh:- C/O Wire Crate Embankment, C/O Water Intake Structure, C/O Main Pump House & Chowkidar Quarter, C/O Toiltet, C/O Deselting Tank Cum Clear Water Tank, Providing And Layi, Manikaran-Himachal Pradesh

Irrigation And Public Health Department has published Providinglift Irrigation Scheme Jaree Bradha In Tehsil Bhunter Distt. Kullu H.P. (Sh:- C/O Wire Crate Embankment, C/O Water Intake Structure, C/O Main Pump House & Chowkidar Quarter, C/O Toiltet, C/O Deselting Tank Cum Clear Water Tank, Providing And Layi. Submission Date for this Tender is 19-08-2020. Crates Tenders in Manikaran Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25074469
Corrigendum : Providinglift Irrigation Scheme Jaree Bradha In Tehsil Bhunter Distt. Kullu H.P. (Sh:- C/O Wire Crate Embankment, C/O Water Intake Structure, C/O Main Pump House & Chowkidar Quarter, C/O Toiltet, C/O Deselting Tank Cum Clear Water Tank, Providing And Layi
Open Tender
Indian
Himachal Pradesh
Manikaran
19-08-2020

Tender Details

ProvidingLift irrigation scheme Jaree Bradha in Tehsil bhunter Distt. Kullu H.P. (SH:- C/O Wire crate embankment, C/O water intake structure, C/O main pump house & chowkidar quarter, C/O Toiltet, C/O Deselting tank cum clear water tank, Providing and laying of rising main and C/O thrust block, Supply and erection of pumping machinery, Instalation of electrical fitting in pump house, Laying of distribution system, C/O outlet and C/O delivery tank

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Aug-2020 Added New Conditions Other 19-08-2020

Key Value

Document Fees
INR 2500 /-
EMD
INR 455680.0 /-
Tender Value
INR 4.43 Crore /-

BOQ Items

Name of Work:ProvidingLift irrigation scheme Jaree Bradha in Tehsil bhunter Distt. Kullu H.P. (SH:- C/O Wire crate embankment, C/O water intake structure, C/O main pump house & chowkidar quarter, C/O Toiltet, C/O Deselting tank cum clear water tank, Providing and laying of rising main and C/O thrust block, Supply and erection of pumping machinery, Instalation of electrical fitting in pump house, Laying of distribution system, C/O outlet and C/O delivery tank ) Estimated Cost :- 44317077/- EMD :- 455680/- Time :- 9 Months
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in foundation trenches etc. in earth work lift up to 1.5 mtrs. Stacking the excavated soil not more than 3 meters away from the edge of excavation and then returing the stacked soil in 15 cm layers when required in to plinth and sides of foundations, consolidating each deposited layer by raming, watering and then disposing of all surplus excavated earth as directed with in a lead of 20 meteers in pick jumper work BI01010001010000000000000515BI0100001114 11594.7 Cum
2 2 Wire crates made of G.I.wire filled with boulders with square cut faces against the wire, (Boulder filling to be measured and paid for separately) G.I.Wire 5mm thick corresponding to SWG-6(15Cmx15cm.Mesh) within all leads and lifts and as directed by Engineer in charge BI01010001010000000000000515BI0100001115 2812.5 Sqm
3 3 Wire crate made of G.I wire filled with boulders with square cut faces against the wire (Wire crate to be measured and paid for separately)in all leads and lifts as per the direction of Engineer-in-Charge. BI01010001010000000000000515BI0100001116 703.13 Cum
4 4 Providing and laying cement concrete 1:6:12 (1cement: 6 sand: 12 graded crushed stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts . BI01010001010000000000000515BI0100001117 9.74 Cum
5 5 Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in all leads and fifts:- BI01010001010000000000000515BI0100001118
6 5.01 Foundation, footings basis of columns etc. and mass concrete. BI01010001010000000000000515BI0100001119 1260.47 Sqm
7 5.02 Vertical surfaces such as wall(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like - BI01010001010000000000000515BI0100001120 1492.66 Sqm
8 5.03 Flat surfaces such as soffits of suspended floors roofs landings and the like floors etc. up to 200 mm in thickness with in all leads and lifts. BI01010001010000000000000515BI0100001121 108.17 Sqm
9 5.04 Beam cantiliver girders and lintels Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 Mtr. in depth in all heights from floor. BI01010001010000000000000515BI0100001122 38.58 Sqm
10 5.05 Sides and Soffits of beams, beam haunchings, contiliver girders, bressumers and lintels not exceeding 1 Metre in depth in all heights from floor complete in all respect with in all leads and lifts. BI01010001010000000000000515BI0100001123 7.93 Sqm
11 6 Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in: - BI01010001010000000000000515BI0100001124
12 6.01 Foundation footing bases of columns and like mass concrete BI01010001010000000000000515BI0100001125 310.58 Cum
13 6.02 Wall ( any thickness but not less than 0.10 mtrs. Thickness) including attached pillasters buttresses, plinth and string courses etc. from top of foundation level upto floor two level. BI01010001010000000000000515BI0100001126 124.24 Cum
14 6.03 Beam cantiliver girders and lintels Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 Mtr. in depth in all heights from floor. BI01010001010000000000000515BI0100001127 3.85 cum
15 7 Providing wood work in frames of doors, wndows, clerestory windows and other frames wrouhgt, frramed and fixed in position in 2nd class Deodar wood within all leads and lifts as per direction & satisfaction of Engineer-in-charge. BI01010001010000000000000515BI0100001128 0.56 Cum
16 8 Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows i/c bright finished black enammeled iron hinges with necessary screws: 2nd class deodar wood 40mm thick including entire carriage of material as per satisfaction of Engineer-in-charge. BI01010001010000000000000515BI0100001129 13.61 Sqm
17 9 Providing and fixing wire gauge shutters using galvanised M.S.wire gauge of I.S gauge designation 8SG with wire of dia 0.56mm for doors windows and clerestory windowsincluding bright finished black enamelled iron hinges with necessary screws 30mm thick 2nd class deodar wood with in all leads and lift complete in all respect BI01010001010000000000000515BI0100001130 14.34 Sqm
18 10 Providing Tor steel reinforcement for RCC work including bending, binding & placing in position complete upto floor two level i.c cost of binding wire with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. BI01010001010000000000000515BI0100001131 26935.5 Kg
19 11 Random rubble masonry/polygonal rubble masonry (uncoursed/brought to courses) with hard stones of approved quality in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level in Cement Mortar 1:6(1 cement:6 sand) BI01010001010000000000000515BI0100001132 22.74 Cum
20 12 20 mm cement plaster in single coat on rough side of brick/stone//concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand) with in all leads and lifts BI01010001010000000000000515BI0100001133 15.79 Sqm
21 13 15 mm cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand) with in all leads and lifts BI01010001010000000000000515BI0100001134 109.77 Sqm
22 14 6mm thick cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) with in all leads and lift complete in all respect BI01010001010000000000000515BI0100001135 104.87 Sqm
23 15 Providing and fixing M.S. grills of require pattern in wooden frames of windows etc. with M.S. Flats, square or round bars with round headed bolts and nuts or by screws with in all leads and lift complete in all respect BI01010001010000000000000515BI0100001136 71.5 Kg
24 16 Boulder filling behind retaining wall under floor with in all leads and lifts complete in all respects. BI01010001010000000000000515BI0100001137 14.36 Cum
25 17 White washing with lime on undecorated wall surfaces(two coats) to give an even shade including thoroughly brooming the surface to remove all dust dirt & other foreign matter with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. BI01010001010000000000000515BI0100001138 130.61 Sqm
26 18 Distempering with dry distemper of approved brand and manufacturer (two coats) and of required shade on un-decorated wall surface to give an even shade over and including priming coat of whiting after througly brushing the surface free from mortar and other foreign matters with in all leads and lifts complete in all respect. in all leads and lifts. BI01010001010000000000000515BI0100001139 84.03 Sqm
27 19 Finshing wall with watr proofing cement paint of approved brand and manufacture (two coats) brushing to give an even shade i/c cleaning of oil, dirt, dust and other foreign matters, sand papering and knotting etc. in all leads and lifts complete in all respect BI01010001010000000000000515BI0100001140 15.79 Sqm
28 20 Applying priming coat on new wood and wood based surfaces with ready mixed paint and brushing to give an even shade including cleaning of all dirt,dust and other foreign matter with in all leads and lifts complete in all respect. BI01010001010000000000000515BI0100001141 27.22 Sqm
29 21 Painting two coats (excluding priming coat) on new wood and wood based surfaces,with enamel paint to give an even shade including cleaningthe surface of dirt ,dust and other foreign matters sand papering and stopping with readymade paint other than white with in all leads and lifts.. BI01010001010000000000000515BI0100001142 27.22 Sqm
30 22 Precast terrazzo tiles hydraulic compressed 20 mm thick with marble chips of specified sizes laid in floors treads of steps and landings on a bed of 25 mm average thickness of cement mortar 1:6 (1 cement :6 sand) jointed with neat cement slurry mixed with pigment to match the\nshade of tiles(wherever required) incliding rubbing and polishing complete with tiles with in all leads and lifts.. BI01010001010000000000000515BI0100001143 53.04 Sqm
31 23 Providing and fixing angle iron door,window,clerestory window frame manufactured from steel iron section of 40X40X6 mm,thickness including hinges jamb,lock jamb,beed and if required angle thrashold ofmild steel angle 50X25 mm welded or rigidly fixed by mechanical means,lugs with split end tails to each jamb including steel but thinges 2.5 mm thick with provision for locking arrangement and shock absorber as specified and applying a coat of approved steel primer after preteatment of the surface as directed by Engineer-in- Charge. BI01010001010000000000000515BI0100001144 6.45 Rmt
32 24 Providing and fixing aluminium tower bolts(barrel type)anodized transparent or dyed to required shade and colour with screws etc.complete BI01010001010000000000000515BI0100001145
33 24.01 200x10mm. BI01010001010000000000000515BI0100001146 30 each
34 24.02 150x10mm. BI01010001010000000000000515BI0100001147 3 each
35 25 Providing and fixing aluminium handles anodized transparent or dyed to required colour or shade with necessary screws etc. complete with in all leads and lifts 125mm BI01010001010000000000000515BI0100001148 23 each
36 26 Providing and fixing anodized alumnium sliding door bolt anodized transparent or dyed to required colour and shade with bolts and nuts and screw complete with in all leads and lift BI01010001010000000000000515BI0100001149
37 26.01 300x16mm BI01010001010000000000000515BI0100001150 2 Each
38 26.02 250x16mm BI01010001010000000000000515BI0100001151 1 Each
39 27 Cement concrete flooring 1:2:4(1cement 2sand 4 graded stone agg.20mm nominal size ) laid in a single layer finished with a floating coat of neat cement within all leads and lifts.40mm thick BI01010001010000000000000515BI0100001152 1.44 Sqm
40 28 Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement: 3sand: 6 graded stone aggregate 20mm nominal size). with in all leads and lifts BI01010001010000000000000515BI0100001153 16.61 Sqm
41 29 Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size will rammed and consolidated and grouted with fine sand including preparation of ground. BI01010001010000000000000515BI0100001154 16.61 Sqm
42 30 Providing 40x3mm flat iron hold fast 40cm long i.e fixing to from with 10mm dia bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm 1:3:6 ( 1cement 3 sand 6 graded stone agg. 40mm nominal size) BI01010001010000000000000515BI0100001155 30 Each
43 31 Brick work using common burnt clay building bricks in super structure above Ground level to 1st floor level in cement mortar 1:6(1cement:6sand) of 2nd class bricks complete in all respect with in all leads and lifts. BI01010001010000000000000515BI0100001156 24.82 Cum
44 32 Brick work using common burnt clay building bricks in foundation and plinth in 1std class bricks cement mortar 1:6(1cement:6sand) with in all leads and lifts. BI01010001010000000000000515BI0100001157 3.59 Cum
45 33 Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded crushed stone aggregate 40mm nominal size )and curing complete excluding cost of form work in foundation and plinth with in all leads & lifts as per the entire satisfaction & direction of Engineer - in - charge. BI01010001010000000000000515BI0100001158 97.08 Cum
46 34 Half brick masonary in common burnt clay buildings bricks in super structure above 1st floor level in cement mortar 1:4(1cement:4sand) 2nd class bricks with in all leads and lifts. BI01010001010000000000000515BI0100001159 5.33 Sqm
47 35 Pointing on brick work with cement mortar 1:3 (1 cement:3 sand) with in all leads and lifts complete in all respect Raised and cut BI01010001010000000000000515BI0100001160 112.84 Sqm
48 36 Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 (1 cement :3 sand) over a 12 mm layer of cement mortar 1:3 (1 cement :3 sand ) and finished neat with in all leads and lifts complete in all respect. BI01010001010000000000000515BI0100001161 12.48 Sqm
49 37 Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in:- BI01010001010000000000000515BI0100001162
50 38 Foundation, footing and base of coloumn and like mass concrete with in all leads and lifts complete in all respect/ BI01010001010000000000000515BI0100001163 818.67 Cum
51 39 Suspended Floor roofs, landing and shelves and their support balconies,beams,girders,bressumers and contilever upto floor two level BI01010001010000000000000515BI0100001164 12.72 Cum
52 40 Providing and laying cement concrete 1:3:6(1 Cement :3 Sand : 6 graded stone aggregate 20mm nominal size)and curing complete excluding the cost of form work in foundation and plinth including all carriage of materials upto all leads and lifts complete in all respects. BI01010001010000000000000515BI0100001165 33.43 Cum
53 41 P/L and jointing of HDPE pipe 110mm for scouring arrangement, PE-80, 4Kg./Sqcm BI01010001010000000000000515BI0100001166 50 Mtrs
54 42 Providing and fixing Cast iron sluice valve of approved make 100mm dia BI01010001010000000000000515BI0100001167 122 Each
55 43 Steel work welded in bulit up sactions, trusses and framed work i/c cutting, hoisting, fixing in position and applying priming coat of red lead paint in :- Gratting, framed guard, bars, ladders and similar work BI01010001010000000000000515BI0100001168 276.75 Kg.
56 44 Providing and fixing to wall ceiling and floor galvanised mild steel tubes (MG) including fitting and clamps including making good the wall deiling and floor complete in all rspect in all leads and lifts and to the entire satisfactionof Engineer in charge 15mm nominal size BI01010001010000000000000515BI0100001169 12 Rmt
57 45 Providing and placing (at all heights) polyethylee water storage tank ISI:12701 marked indicating the BIS license no. with cover and suitable locking arrangment and making necessary holes for inlet, outlet and overflow pipes, including all fittings and float valve excluding the base support for tank (Sintex, electroplast, Star, Lotus or equivalent having ISI lience). 300 lts. capacity BI01010001010000000000000515BI0100001170 1 Each
58 46 Providing and fixing vitreous china wash, down water closet (European type WC pan) with integral 'P' or 'S' trap including jointing the trap with soil pipe in cement mortar 1:1. Seat and cover to be measured and paid for seperately. Anglo indian universal closet BI01010001010000000000000515BI0100001171 1 Each
59 47 Providing and fixing plastic seat and cover for wash down water closet with C.P. brass hinges and rubber buffers: white plastic seat and cover, solid type BI01010001010000000000000515BI0100001172 1 Each
60 48 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) confirmin to IS:7231, with all fitting and fixtures complete. 10 litre capacity-white BI01010001010000000000000515BI0100001173 1 Each
61 49 Providing and fixing PVC/GI inlet connection for flushing pipe connecting with W.C. pan BI01010001010000000000000515BI0100001174 1 Each
62 50 Providing and fixing C.P. brass stop cock(concealed) of standard design and of approved make confirming to IS:8931. 15mm nominal bore BI01010001010000000000000515BI0100001175 1 Each
63 51 Providing and fixing C.P. brass angle valve of standard design and of approved make 15mm nominal bore BI01010001010000000000000515BI0100001176 1 Each
64 52 Providing and fixing C.P. water jet including connection pipe with check nut complete in all respect BI01010001010000000000000515BI0100001177 1 Each
65 53 Providing and fixing PVC pipes of 10 kg f/Sq.cm working pressure including fitting as per requirement at site complete in all respect in all leads and lift. 110mm OD BI01010001010000000000000515BI0100001178 10 Rmtr.
66 54 Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group-C BI01010001010000000000000515BI0100001179 22 Each
67 55 Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. BI01010001010000000000000515BI0100001180
68 55.01 2x1.5 Sq. mm. BI01010001010000000000000515BI0100001181 210 Mtrs.
69 55.02 2x4.0 Sq. mm. BI01010001010000000000000515BI0100001182 120 Mtrs.
70 56 Supply and fixing 3 pin 5/6 amps. Socket outlet on the exists switch box/covers including connections etc. as required BI01010001010000000000000515BI0100001183 3 Each
71 57 Supply and fixing 2 pin 5/6 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connection etc. as required. BI01010001010000000000000515BI0100001184 3 Each
72 58 Supplying and fixing 3 pin 15/16 amps. Socket outlet on the exists switch box/covers including connection etc. as required. BI01010001010000000000000515BI0100001185 3 Each
73 59 Supply and fixing 15/16 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connection etc. as required. BI01010001010000000000000515BI0100001186 3 Each
74 60 Supplying and fixing woodern box of following size (nominal) on surface or recess with suitable size of phenolic laminated sheet cover of in front as required BI01010001010000000000000515BI0100001187
75 60.01 a) 229mm x102mmx60mm deep BI01010001010000000000000515BI0100001188 3 Each
76 60.02 b) 203mmx152mmx60mm deep BI01010001010000000000000515BI0100001189 3 Each
77 61 Supplying and fixing ceiling rose on existing junction box/wooden block including connections etc. as required. BI01010001010000000000000515BI0100001190 9 Each
78 62 Supplying and fixing plain pandent with 16/20mm twin twisted, flexible PVC insulated copper cable and backlite pendant holder including connection etc as required. BI01010001010000000000000515BI0100001191 3 Each
79 63 Supplying and fixing 5 Amps to 32 Amps rating, 240 volts, L series miniature circuit breaker of following poles in the existing MCB Db complete with connection testing and commissioning etc. as required Cat-A (single pole) BI01010001010000000000000515BI0100001192 6 Each
80 64 Supplying and fixing of following way, single pole and netural, sheet steel, MCB distribution board, 240 volts on surface/recess, complete with tinned copper busbar, netural link, earthbar, dibnbar, detachable gland plates, inter connections, i/c painting, earthing etc. as required busbar 8 way BI01010001010000000000000515BI0100001193 1 Each
81 65 Supplying and fixing following rating, double pole, 240volts, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required 63Amp Cat-A BI01010001010000000000000515BI0100001194 1 Each
82 66 Providing, installing, testing and commissioning of ceilling fan and regulator i/c wiring the down rod of standard length (upto 30cm with 1.5 sqmm PVC insulated copper conductor single core cable etc. as required. Ceiling fan 1400mm sweep Cat.-A BI01010001010000000000000515BI0100001195 2 Each
83 67 Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snap-on installers, suitable for 28watt FTL (T5), complete with all accessories (including one no. T-5 tube), connections, testing and commissioning etc. as required. 1x28 watt-FTL (T5) Category-A BI01010001010000000000000515BI0100001196 4 Each
84 68 Providing and fixing following type of surface mounting decorative mirror optics luminaire with powder coated CRCA sheet steel housing, low glare aluminium mirror reflector, pre-wired with 110 V starter & 36/40 w copper ballast for housing CFL (but excluding the cost of CFL), complete with all accessories, connections, testing and commissioning etc. as required. 2 x36 watt-CFL Philips make (Category-A) BI01010001010000000000000515BI0100001197 2 Each
85 69 Providing and fixing two core service wire 6sqmm thick in all leads and lifts BI01010001010000000000000515BI0100001198 45 Mtrs.
86 70 Providing , laying, fixing, jointing and testing in trenches MEERW pipe of following dia meters confirming to ISO 3183-2007, pipe grade-L290 or X-42 having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). BI01010001010000000000000515BI0100001199
87 70.01 Submersible Stage BI01010001010000000000000515BI0100001200
88 70.02 300mm dia MSERW pipe, Wall thickness 4.40 mm, Flange table-5 BI01010001010000000000000515BI0100001201 60 Rmtr.
89 70.03 1st stage BI01010001010000000000000515BI0100001202
90 70.04 300mm dia MSERW pipe, wall thickness 5.6mm, flange table-34 BI01010001010000000000000515BI0100001203 55 Rmtr.
91 70.05 300mm dia MSERW pipe, wall thickness 4.40mm, flange table-28 BI01010001010000000000000515BI0100001204 50 Rmtr.
92 71 Providing , laying, jointing ( by way of circumfrential butt welded joints by electrical arc welding) and testing of MSREW pipe of following dia meters confirming to ISO:3183-2007, pipe grade-L290 or X-42 (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in random length of 4 to 7 meters, including manufacturing reducers/tapers, all short pieces, bends, reducers, tees etc.as per site requirement made from parent tube. The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respect to the satisfation of the engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). BI01010001010000000000000515BI0100001205
93 71.01 300mm dia MSERW pipe wall thickness 5.60mm BI01010001010000000000000515BI0100001206 1045 Rmtr.
94 71.02 300mm dia MSERW pipe wall thickness 4.40 mm BI01010001010000000000000515BI0100001207 950 Rmtr.
95 72 Raw water stage: -Providing and installation of suitable raw water submersible pumpset type KRT capable of handling 6000 PPM turbidity of KSB make conforming to latest BIS code. The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft . The impeller of pump shall be directly mounted on extended submersible sq cage motor shaft conf to BIS 9238-1979 with up to date amendments of 1450(N) RPM, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear,It should be fitted with device to take up expanion of water on heating of motor & suitable for operation on 415 +/- 10% volts 3 Phase 50 C/S AC supply. The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standard accessories as supplied by the manufacturers complete, suitable for fulfilling the following requirements:- BI01010001010000000000000515BI0100001208 3 Set
96 72.01 Total head: 14.94 mtrs. BI01010001010000000000000515BI0100001209
97 72.02 Discharge: 73.90LPS BI01010001010000000000000515BI0100001210
98 72.03 Dia of rising main: 300mm BI01010001010000000000000515BI0100001211
99 72.04 Length of rising main: 60 mtrs. BI01010001010000000000000515BI0100001212
100 72.05 Static Head: 9 mtr. BI01010001010000000000000515BI0100001213
101 72.06 Pumping Hours: 20 hours BI01010001010000000000000515BI0100001214
102 72.07 Altitude above MSL: 950Mtr BI01010001010000000000000515BI0100001215
103 72.08 (Note:- three sets will run in parllel to lift 73.90 LPS discharge) BI01010001010000000000000515BI0100001216
104 73 Providing and installation of control panel as per KSB specifications and having protection of motor on occurance of faults (triping on occurance of fault(s) i.e. Moisture, high motor temperature, dry running, reverse rotation, single phasing, voltage imbalance, overload and short circuit) and indiation thereof by glowing fault lamp, for motors above 30KW another protection of Mechanical seal failure shall also be provided in addition to above protections, fitted with required accessories as per manufacturer standard practice. BI01010001010000000000000515BI0100001217 3 Set
105 74 Providing and fixing Double flanged Mechneil/Leader/Pelican/Bhel/Gled/Kirloskar/Kartar make Cast iron sluice valve in delivery side confirming to class IS:780 PN 1.0, one size higher than delivery outlet size of pump BI01010001010000000000000515BI0100001218 3 Each
106 75 Providing and fixing Double flanged Mechneil/Leader/Pelican/Bhel/Gled/Kirloskar/Kartar make Cast iron swing check type reflux valve in delivery side confirming to class IS:5312 PN 1.0, one size higher than delivery outlet size of pump BI01010001010000000000000515BI0100001219 3 Each
107 76 Providing and laying PVC insulated armoured copper conductor cable Siemens/Gloster/IEC/ICC/EICO/National/Grandly make of suitable size and suitable for motor offered under item no.72 complete with flexible pipe and couplers from HPSEB meter to panel, switch, starter complete job. The type and size shall be subject to approval of Electrical authorities and in case of its non acceptance the same shall be replaced free of cost by the tenderer Supply side:_____________mm² Motor side:_____________mm² BI01010001010000000000000515BI0100001220 1 Job
108 77 Providing and fixing Double flanged Mechneil/Leader/Pelican/Bhel/Gled/Kirloskar/Kartar make Cast iron swing check type reflux valve in delivery side confirming to class IS:5312 PN 1.0, equal to dia of rising main i.e. 300mm dia BI01010001010000000000000515BI0100001221 1 Each
109 78 Providing and laying PVC insulated round copper conducter cable of suitable size suitable for motor offered under item no. 72 complete having suitable cores to fulfill requirement of star delta starter and protection /controls from panel to motor 10 mtrs. cable per set shall be supplied free of cost ( cost inclusive in cost of pump set) additional lehgth shall be measured to and paid seperately. cost to be quoted for additional length over and above free cable of 10 mtr/pumpset BI01010001010000000000000515BI0100001222 20 Mtr.
110 79 Providing and fixing 100mm dial pressure guage of Fiebig/Bourden make having range 0-7Kg/cm² with copper tubing, stop cock and allied accessories as per IS:3624-1987 latest with upto date amendments BI01010001010000000000000515BI0100001223 3 Each
111 80 Providing and fixing MS/MSERW pipe of suitable size as detailed here under for delivery and common header complete in all respects with all specials like bends, tees, reducers, increasers, companion flanges including rubber/asbestos gaskets of minimum 3mm thickness as per IS 1364-1983. The pipes shall be as per relevant IS code, the flanges shall be compatible with pumps, valvs etc. and sutable for withstanding 1.5 times the working pressure likely to be induced as stipulated against item no. 72 above. Delivery side: pipe of one step higher than delivery of pump (3x10 Rmtr.) Common header 300mm dia (5 rmtr.) BI01010001010000000000000515BI0100001224 1 Job
112 81 Providing and fixing of L&T/Havells make shunt capacitor of suitable rating confirming to IS:2834-1986 latest with upto date amendments to raise power factor at site from 0.85 to 0.95, complete with required cable for direct connection to control panel and fittings. BI01010001010000000000000515BI0100001225 3 Each
113 82 Providing and fixing of cable for water level guard, supporting clamps, cable clips of required size. BI01010001010000000000000515BI0100001226 1 Job
114 83 1st Stage:- Providing horizontal spindle, horizontal radial split casing/end suction (back out arrangment) single/double/multistage centrifugal pump or combination of pump in seris/parallel of recommended pumps such as Mather and Platt/KSB/Beacon/L&T/Kirloskar/Jyoti as per BIS 1520-1980 with upto date amendments, read with IS 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling and common MS/Cast steel base plateform ( base plate to be from the manufactturer of pumping unit only) to slip ring/screen protented drip proof induction motor.motors of standard make such as Kirloskar/BHEL/Compton/NGEF/GEC/Siemens/Jyoti/ABB and suitable for operation on 400(+/-) 10% volts, 50cycles/second, 3 phase AC electric supply. The power of electric motor/motors should be designed +10% in excess of the maximum power required by the p[ump/pumps inthe operation rangeof (+) 10% and (-) 25% of duty point head. The motor.motors a per IS 325-1978 with uo to date amendments read with IS 900-1972. It should include cost of bearing nuts, bolts and painting etc. and should meet the following requirement: BI01010001010000000000000515BI0100001227 3 Set
115 83.01 Discharge: 73.90LPS (24.63 LPS for each pump) BI01010001010000000000000515BI0100001228
116 83.02 Total Dynamic head: 419.00mtrs. BI01010001010000000000000515BI0100001229
117 83.03 a) LWL in sump well: 1001.25 mtrs. BI01010001010000000000000515BI0100001230
118 83.04 b) Shaft level: 1000.00 mtrs. BI01010001010000000000000515BI0100001231
119 83.05 c) Level at discharge point: 1401 mtrs. BI01010001010000000000000515BI0100001232
120 83.06 d) Suction lift : +ve mtrs. BI01010001010000000000000515BI0100001233
121 83.07 e) Discharge head: 401.00 mtrs. BI01010001010000000000000515BI0100001234
122 83.08 f) Static head: 401.00 mtrs. BI01010001010000000000000515BI0100001235
123 83.09 Rising main: a) Length 2100 mtrs 300mm dia BI01010001010000000000000515BI0100001236
124 83.1 Pumping hours: 20 Hours BI01010001010000000000000515BI0100001237
125 83.11 Altitude of installation above MSL: 950 mtrs. BI01010001010000000000000515BI0100001238
126 83.12 Characteristics of water: Raw water with turbidity up to 3000 PPM BI01010001010000000000000515BI0100001239
127 83.13 Temprature : 20 degree centigrade. BI01010001010000000000000515BI0100001240
128 84 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments, immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001241 3 Set
129 85 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.83 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001242 3 Each
130 85.01 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001243 3 Each
131 85.02 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001244 3 Each
132 85.03 c) The voltage monitor relay of AE/MEI/L&T/Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482 (latest edition)\n BI01010001010000000000000515BI0100001245 3 Each
133 85.04 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001246 1 Each
134 85.05 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001247 1 Each
135 85.06 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001248 1 Each
136 85.07 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001249 3 Set
137 85.08 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001250 3 Set
138 85.09 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001251 3 Set
139 85.1 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001252 3 Set
140 85.11 k) Capacitor of Crompton/L&T/NGEP/Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001253 3 Each
141 85.12 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001254 3 Each
142 85.13 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001255 3 Each
143 85.14 n) Providing antivibration pads under the pumps and motors of suitablesize for the above pumping machinery as per IS:6337:1971.\n BI01010001010000000000000515BI0100001256 3 Each
144 86 Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments\n BI01010001010000000000000515BI0100001257 3 Each
145 87 Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses make for one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standard with upto date ammdnements\n BI01010001010000000000000515BI0100001258 3 Each
146 88 Providing double flanged swing type cast steel valves class ASA-300 of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as perBIS standards with upto date ammendments.\n BI01010001010000000000000515BI0100001259 3 Each
147 89 Providing double flanged cast steel reflux valves class ASA-300 of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make and of 300mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.\n BI01010001010000000000000515BI0100001260 1 Each
148 90 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001261 3 Each
149 91 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001262 1 Each
150 92 Installation of all the items apparing at serial No.83 to 91 as per the systematic drawing \n BI01010001010000000000000515BI0100001263 1 Job
151 93 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thickness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.83. The size of the various components to be as under:\n BI01010001010000000000000515BI0100001264
152 93.01 Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n BI01010001010000000000000515BI0100001265 10 Rmtr.
153 93.02 Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001266 10 Rmtr.
154 93.03 Common header :One dia higher then delivery of pump x300 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed\n BI01010001010000000000000515BI0100001267 5 Rmtr.
155 94 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor\n BI01010001010000000000000515BI0100001268
156 94.01 (a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001269 10 Mtr.
157 94.02 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001270 10 Mtr.
158 95 Providing and fixing double loop earth with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect(for raw water stage & 1st stage).\n BI01010001010000000000000515BI0100001271 1 Job
159 96 Laying, jointing and testing HDPE pipe complete in all respects with in all leads and lifts as per direction of the Engineer in charge (L.R.) BI01010001010000000000000515BI0100001272
160 96.01 75mm,PN 4,PE-80 BI01010001010000000000000515BI0100001273 805 Rmtr.
161 96.02 75mm,PN 6,PE-80 BI01010001010000000000000515BI0100001274 1080 Rmtr.
162 96.03 75mm,PN 8,PE-80 BI01010001010000000000000515BI0100001275 1400 Rmtr.
163 96.04 75mm,PN 10,PE-80 BI01010001010000000000000515BI0100001276 1345 Rmtr.
164 96.05 90mm,PN4,PE-80 BI01010001010000000000000515BI0100001277 1575 Rmtr.
165 96.06 90mm,PN6,PE-80 BI01010001010000000000000515BI0100001278 3215 Rmtr.
166 96.07 90mm,PN8,PE-80 BI01010001010000000000000515BI0100001279 1655 Rmtr.
167 96.08 90mm,PN10,PE-80 BI01010001010000000000000515BI0100001280 780 Rmtr.
168 96.09 110mm,PN4,PE-80 BI01010001010000000000000515BI0100001281 1510 Rmtr.
169 96.1 110mm,PN6,PE-80 BI01010001010000000000000515BI0100001282 1920 Rmtr.
170 96.11 110mm,PN8,PE-80 BI01010001010000000000000515BI0100001283 750 Rmtr.
171 96.12 110mm,PN10,PE-80 BI01010001010000000000000515BI0100001284 800 Rmtr.
172 96.13 125mm,PN4,PE-80 BI01010001010000000000000515BI0100001285 250 Rmtr.
173 96.14 140mm,PN4,PE-80 BI01010001010000000000000515BI0100001286 385 Rmtr.
174 96.15 160mm,PN4,PE-80 BI01010001010000000000000515BI0100001287 290 Rmtr.
175 96.16 200mm,PN4,PE-80 BI01010001010000000000000515BI0100001288 890 Rmtr.
176 96.17 250mm,PN4,PE-80 BI01010001010000000000000515BI0100001289 1425 Rmtr.
Disclaimer :