Military Engineer Services-MES has published Repairs To Chequered Tiles And Interlocking Tiles At Various Locations In Zone B At Arakkonam. Submission Date for this Tender is 24-08-2020. Tiles and Flagstones Tenders in GE M NAS ARAKKONAM Tamil Nadu. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Aug-2020 | Other Corrigendum | Other | 24-08-2020 |
2 | 14-Aug-2020 | Othercorrigendum1 | Other | 24-08-2020 |
Name of Work: REPAIRS TO CHEQUERED TILES AND INTERLOCKING TILES AT VARIOUS LOCATIONS IN ZONE 'B' AT ARAKKONAM (TENDER ID NO. 2020_MES_365277_1) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cms thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge. | 186 | Cum | |
2 | 2 | Material and labour for plain cement concrete type D-2, 1:4:8 (Using 40mm graded stone aggregates) as in sub base complete all as specified and as directed by Engr-in-charge. | 124 | Cum | |
3 | 3 | Material and labour for sand filling as a cushioning/ bedding complete all as specified and as directed by Engr-in-charge. | 75 | Cum | |
4 | 4 | Material and labour for chequered cement concrete tiles 300x300x20-22mm thick set, (with grey cement and pigment) jointed and pointed in neat cement slurry over 20mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed by Engr-in-charge. | 240 | Sqm | |
5 | 5 | Material and labour for PCC 1:2:4 type B 1 (Using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed by Engr-in-charge. | 2 | Cum | |
6 | 6 | Supply and fix 75mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engr-in-charge. | 50 | RM | |
7 | 7 | Demolition of brickwork or stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc., but excluding ashlars facings, dressed stonework complete all as specified and as directed by Engr-in-charge. | 27 | Cum | |
8 | 8 | Material and labour for walling random rubble, brought upto uncoursed well bonded, bedded and solidly hearted, built in CM 1:4 complete all as specified and as directed by Engr-in-charge. | 7 | Cum | |
9 | 9 | All as per item No.08 here-in-before but except stone. | 3 | Cum | |
10 | 10 | Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exc 40mm to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and as directed by Engr-in-charge. | 24 | Sqm | |
11 | 11 | Material and labour for racking out joints/ pointing to random rubble or polygonal rubble uncoursed or brought up to courses built in cement mortar complete all as specified and as directed by Engr-in-charge. | 80 | X Sqm | |
12 | 12 | Material and labour for flush pointing to random rubble mansonry, uncoursed or brought upto courses in CM 1:3 complete all as specified and as directed by Engr-in-charge. | 83 | X Sqm | |
13 | 13 | Material and labour for old size brick work with sub class 'B' bricks straight or curved on plan exc 6m mean redius built in CM 1:4 complete all as specified and as directed by Engr-in-charge. | 4 | Cum | |
14 | 14 | All as per item No.13 here-in-before but except bricks. | 2 | Cum | |
15 | 15 | Material and labour for old size brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed by Engr-in-charge. | 100 | Sqm | |
16 | 16 | Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. | 50 | Sqm | |
17 | 17 | Material and labour for three coat white wash on newly plastered surfaces of wall including preparation of surface complete all as specified and as directed by Engr-in-charge. | 50 | Sqm | |
18 | 18 | Material and labour for cement concrete type B-0, 1:2:4 (Using 12.5 mm graded stone aggregates) for edging/coping complete all as specified and as directed by Engr-in-charge.\n | 13 | Cum | |
19 | 19 | Demolition of cement concrete (reinforced) in ground floors and pavings not exc 15 cms thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge. | 6 | Cum | |
20 | 20 | Material and labour for precast reinforced cement concrete 1:2:4 type B1 (Using 20mm graded stone aggregate) as in cover slab for drain set in CM 1:6 complete all as specified and as directed by Engr-in-charge. | 6 | Cum | |
21 | 21 | Supply and fix for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-charge. | 667 | Kg | |
22 | 22 | Material and labour for machine pressed precast concrete interlocking paver block with pigment any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade complete all as specified and as directed by Engr-in-charge. | 1000 | Sqm | |
23 | 23 | Taking down rain water pipes (any size or pattern) including all fittings heads, shoes etc., including removal complete all as specified and as directed by Engr-in-charge.\nNote : The work shall be carried out upto Fifth storey buildings(18.00m). | 120 | RM | |
24 | 24 | Supply and fix for 75mm bore PVC (SWR) pipes single socket in any length with rubber ring jointed to fixed to wall using stack clamps complete all as specified and as directed by Engr-in-charge. | 70 | RM | |
25 | 25 | Supply and fix for 110mm bore PVC (SWR) pipes single socket in any length with rubber ring jointed to fixed to wall using stack clamps complete all as specified and as directed by Engr-in-charge. | 50 | RM | |
26 | 26 | Supply and fix for 75mm PVC (SWR) bends with access door any radius complete all as specified and as directed by Engr-in-charge. | 10 | Each | |
27 | 27 | Supply and fix for 110mm PVC (SWR) bends with access door any radius complete all as specified and as directed by Engr-in-charge. | 10 | Each | |
28 | 28 | Supply and fix in repairs 75mm dia bore PVC (SWR) junction single, (single T) equal or un equal with access door complete all as specified and as directed by Engr-in-charge. | 10 | Each | |
29 | 29 | Supply and fix in repairs 110mm dia bore PVC (SWR) junction single, (single T) equal or un equal with access door complete all as specified and as directed by Engr-in-charge. | 10 | Each | |
30 | 30 | Supply and fix in repairs stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm dia PVC pipes complete all as specified and as directed by Engr-in-charge. | 35 | Each | |
31 | 31 | Supply and fix in repairs stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110mm dia PVC pipes complete all as specified and as directed by Engr-in-charge. | 35 | Each | |
32 | 32 | Material and labour for providing post construction anti termite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engr-in-charge. | 200 | Sqm | |
33 | 33 | Material and labour for providing post construction anti termite treatment by treating the soil along with external periimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed by Engr-in-charge. | 223 | RM | |
34 | 34 | Material and labour for hardcore of gauge of using broken stone or boulders not exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-charge. | 15 | Cum | |
35 | 35 | Material and labour for 75mm thick PCC 1:3:6 type C-1 (Using 20mm graded stone aggregate) as in plinth protection, including finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. | 200 | Sqm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy