Military Engineer Services-MES has published Provision Of Covered Accn With Hard Standing For A Vehicle At Adwance Work Shop Detachment Of 812 Fd Work Shop Coy Eme At Mil Stn Jasai Under Ge Army Barmer. Submission Date for this Tender is 24-08-2020. Mechanical engineering Service Tenders in GE ARMY BARMER Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work : PROVISION OF COVERED ACCN WITH HARD STANDING FOR "A'' VEHICLE AT ADWANCE WORK SHOP DETACHMENT OF 812 FD WORK SHOP COY EME AT MIL STN JASAI UNDER GE(A) BARMER | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in hard / dense soil complete all as specified and as directed. | 530 | SQM | |
2 | 2 | Excavating in post holes or similar holes each not n exc 0.50 cu.m,getting out in hard rock by chiselling,returning,fillig in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm complete all as specified and as directed. | 12 | EACH | |
3 | 3 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft / loose soil complete all as specified and directed. | 10 | CUM | |
4 | 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated rock complete all as specified and as directed. | 6 | CUM | |
5 | 5 | Removal of excavated material [soils] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. | 4 | CUM | |
6 | 6 | M&L PCC 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concerete including necessary form work complete all as specified and as directed. | 5.5 | CUM | |
7 | 7 | M&L rolled mild steel joist, channel, angle, or tee sections, confirming to Fe410 - W(Grade E-250) quality A, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed. | 3300 | KG | |
8 | 8 | Preparation of new or previously untreated steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified and as directed. | 40 | SQM | |
9 | 9 | M&L prepainted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. | 180 | SQM | |
10 | 10 | Prepainted Galvalume aluminium zinc coating GI based pain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in ridges etc.,fixed with self tapping screws complete all as specified and as directed. | 15 | SQM | |
11 | 11 | M&L hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. | 79.5 | CUM | |
12 | 12 | M&L 100 mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate for sub base as in floor including necessary form work complete all as specified and as directed . | 530 | SQM | |
13 | 13 | M&L PCC 100mm thick,1:2:4 type B2 by using 40 mm graded crushed stone aggregate including necessary form work and finishing the surface even and fair without using extra cement complete all as specified and as directed. | 530 | SQM | |
14 | 14 | Stone sett flooring with stone setts of size 200 to 250mm long,150 to 200mm wide and 150mm deep and sides dressed, bedded in cement mortar 1:3, joints 20mm thick, grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as specified and directed. | 530 | SQM | |
15 | 15 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removing rubbish to out side MD land complete all as specified and as directed. | 50 | CUM | |
16 | 16 | M & L walling of random rubble masonry,well bonded ,bedded and solidly hearted built in cement mortar 1:6 and brought up to course complete all as specified and directed. | 45 | CUM | |
17 | 17 | M & L walling of random rubble masonry,well bonded ,bedded and solidly hearted built in cement mortar 1:6 and brought up to course except stone complete all as specified and directed. | 5 | CUM | |
18 | 18 | Extra over for stone walling for hammer dressing to face stones and dressing of the face beds and joints as speciifed of random rubble walling, brought upto course with max depression on face from straight edge held against the dressed surface n. exc 20 mm complete all as specified and as directed. | 80 | SQM | |
19 | 19 | M & L PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and as directed. | 2 | CUM | |
20 | 20 | M&L rendering 15mm thick in CM 1:4 on stone masonry wall surfaces, finished even and smooth without using extra cement complete all as specified and directed. | 80 | SQM | |
21 | 21 | Preparation of new plastered or unplastered surfaces and applying three coats of white wash on walls complete all as specified and as directed. | 80 | SQM | |
22 | 22 | M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty drawn through and including PVC casing & caping with all accessories and terminated to and including provision of sunken 1.6mm thick pressed steel terminal boxes with 3mm thick hylam sheet cover on top for fixing switches, sockets / regulators etc.,, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light point controlled by one, one way switch complete all as specified and directed . | 15 | POINT | |
23 | 23 | All as per Item No. 22.00 above but for 15 Amps socket point on independent board with 4 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire,complete all as specified and as directed. | 2 | POINT | |
24 | 24 | M&L factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 8 way, 240V for fixing MCB's complete all as specified and as directed. | 1 | EACH | |
25 | 25 | M&L MCB SPN ‘C’ Curve 10KA , 40 amps 230V complete all as specified and as directed . | 1 | EACH | |
26 | 26 | M&L MCB SP ‘C’ Curve 10KA , 6-30 amps 230V complete all as specified and as directed . | 6 | EACH | |
27 | 27 | M&L switch piano type 5 Amps, single pole, flush type, one way, complete all as specified and as directed. | 15 | EACH | |
28 | 28 | M&L switch piano type 15 Amps, single pole, flush type, one way, complete all as specified and as directed. | 2 | EACH | |
29 | 29 | M&L socket outlet combination 5A/15A, 5 in 1, flush type complete all as specified and as directed . | 2 | EACH | |
30 | 30 | M&L ceiling rose, 3 phase / PVC / Polycarbonate, isolated bodycomplete all as specified and as directed. | 12 | EACH | |
31 | 31 | S&F LED light fitting 1X10W bulk head luminaries, with lamp holders including 10 W LED bulb complete all as specified and as directed \nMake : Havells/ Bajaj/Philips/CG | 2 | EACH | |
32 | 32 | S&F lamp holder, PVC / polycarbonate type suitable for LED bulb including LED lamp 9W 230 volts complete all as specified and as directed . | 3 | EACH | |
33 | 33 | S & F surface and wall mounted 20 W tube light fitting LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electroinc driver including tube rod and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.\nMake :- Model No. LHEWEBP7IN1W020 of Havells or techno commercially equivalent make in Bajaj / CG / Philips | 10 | EACH | |
34 | 34 | S&F LED 25 W street light fitting of new generation energy saving and environmental friendly long life, pressure die cast aluminimu housing with high efficient LED as lighting source and PC cover having TOP opening separate driver compartment with IP-66 protection and impact resistance of IK 07 including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.\nMake :- Havells Model No. ENDURAPEARLSL25WLED757SASYTOPCMP or techno commercially equivalent make in Bajaj / CG / Philips | 2 | EACH | |
35 | 35 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and as directed.NOTE :(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-( ii) Item includes the cost of GI pipe up to 7.5m for protection of earth wire. any variation in length beyond 7.50 m shall be measured separately.(iii) Item includes cost of lead wire up to 7.5 m Any variation in length beyond 7.50 m shall be measured separately.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. | 1 | EACH SET | |
36 | 36 | Supply, laying, jointing, testing and commissioning 1100 volt grade heavy duty XLPE insulated LT under ground cable, sheathed, as per IS- 7098 (Part I) 1988, galvanized steel strip armoured heavy duty multi stranded aluminum conductor laid in trenches / passed through pipe/duct road crossing, fixed on poles/ wall with clamps made out of mild steel flat iron including fixing accessories like brass cable glands double compression type, lugs, nuts, bolts, washers etc of size 2 core 10 sqmm complete all as specified and directed | 43 | RM | |
37 | 37 | Supply and spreading clean dry sand ( tibba sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed .\nNote :- Punned thickness shall be measured for the purpose of payment. | 3 | CUM | |
38 | 38 | Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed. | 10 | SQM | |
39 | 39 | S&F GI tubing 40mm bore light grade with all fittings and laid in trenches/ fixed on walls/ poles or laid under road / paving with clampetc., for protection of cable complete all as specified and as directed. | 6 | RM |