Provision Of Covered Cable Ducting And Cable Route Markers Between Mes Sub Stations And Special Repairs To Old Earthings To Covert Chemical Earthings , Solar Lights And Dfgt Set Batteries Into New At Various Locations In Cdm Secunderabad Under Ge Utility, SECUNDERABAD-Telangana

Military Engineer Services-MES has published Provision Of Covered Cable Ducting And Cable Route Markers Between Mes Sub Stations And Special Repairs To Old Earthings To Covert Chemical Earthings , Solar Lights And Dfgt Set Batteries Into New At Various Locations In Cdm Secunderabad Under Ge Utility. Submission Date for this Tender is 14-08-2020. Chemical Supply Tenders in SECUNDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

25004490
Provision Of Covered Cable Ducting And Cable Route Markers Between Mes Sub Stations And Special Repairs To Old Earthings To Covert Chemical Earthings , Solar Lights And Dfgt Set Batteries Into New At Various Locations In Cdm Secunderabad Under Ge Utility
Open Tender
Indian
Telangana
SECUNDERABAD
14-08-2020

Tender Details

Provision Of Covered Cable Ducting And Cable Route Markers Between Mes Sub Stations And Special Repairs To Old Earthings To Covert Chemical Earthings , Solar Lights And Dfgt Set Batteries Into New At Various Locations In Cdm Secunderabad Under Ge Utility

Key Value

Document Fees
INR 500 /-
EMD
INR 59900.0 /-
Tender Value
INR 28.95 Lakhs /-

BOQ Items

PROVN OF ELECTRIC METERS FOR SECOND AC IN DHRUVA ACCN AND SERVO STABILISERS, SECIAL REPAIRS FOR UPGRADATION OF LT CABLES AND PANELS IN DHRUVA COMPLEX AT CDM SECUNDERABAD UNDER GE UTILITY SECUNDERABAD
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, Install, Testing and Commissioning of AC single phase two wire, tamper proof, static meter of class 1.0, 240 V, 50 Hz, basis current 10-60 A, max continuous current 600% of basis current conforming to IS-13779 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in cyantech mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuits complete all as specified and directed.\nMake:- L&T/SECURE/SCHNEIDER ELECTRIC\n BI01010001010000000000000515BI0100001112 76 Each
2 2 Supply, Install, Testing and Commissioning IP 51 rated Data Concentrator Unit (DCU) compatible for remote Automatic Meter Reading (AMR) solution and capable of communicating with the static energy meter in the corresponding frequency band and with the data server through GPRS and shall have minimum data transfer rate of 9600 bps, internal memory to store data of 50 modules for 6 month period and shall be based on Cyantech Mesh network within 50 metre range complete all as specified and directed. Make:- L&T/Capital/Cyanconnode.\n BI01010001010000000000000515BI0100001113 3 Each
3 3 Supply, Install, Testing and Commissioning of IP 51 rated Repeater unit with inbuilt Low Power Radio Frequency (LPRF) Communication Facility and capable of communicating within Cyantech Mesh network with inbuilt AC power supply complete all as specified and directed. \nMake:- L&T/Capital/Cyanconnode.\n BI01010001010000000000000515BI0100001114 1 Each
4 4 Design, Supply, Install, Testing and Commissioning configuration of cloud hosted multi user web based Software with provision of following modules:-\n(a) Meter Data Management Module:- The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the following data:-\n(i) 30 minutes instantaneous data from all the meters for seven parameters i.e., Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency.\n(ii) The monthly and quarterly billing survey data for cumulative energy and maximum demand.\n(b) Billing Module:- The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to administative and end users.\n BI01010001010000000000000515BI0100001115 76 Each Meter
5 4.01 (c) Occupation and Vacation Module:- The system would support occupation / vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events.\n(d) Customer Portal:- The system would include a customer portal for the resident /occupant to login and view their own energy / billing data.\n(e) Energy Accounting Module:- The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available.\n(f) Communication Module:- The system would provide communication of energy data and bills via print, email and sms methods.\n(g) Meter Master Data:- The system would support meter master data repository and also would support meter replacement process.\n(h) Excel Export:- The system would support export of metering and billing data in excel format. \nMake:- Innologix/L&T/Capital.\n BI01010001010000000000000515BI0100001116
6 5 Supply and fix Voltage stabilizer for automatic operation , single phase naturally oil cooled indoor type & designed for input variation between 340 V to 480 V with Output voltage stabilizer at 415 V with accuracy of +/- 1% and capacity of 100 KVA as specified and directed BI01010001010000000000000515BI0100001117 1 Each Job
7 5.01 1. High Voltage Cut off 2. Low Voltage Cut off 3. Time delay of 3 sec. for Cut off. 4. Single Phase Prevention and cut off 5. Phase Reversal Protection and cut off 6. Surge & Spike Protection/Surge Arrester/RF Suppressor 7. Frequency cut off protection 8. Neutral failure protection 9. Earth neutral voltage cut off protection 10. Electronic over& under voltage trip with time delay for input & output \n11. Electronic overload protection and short circuit protection and the manual bypass is built in \n12. Fully Automatic / Manual Provision of stabilizer bypass mode switch Manual / Auto Reset with time delay and Programmable 13. Response Time : Less than 10mili second BI01010001010000000000000515BI0100001118
8 6 Supply and fix Voltage stabilizer for automatic operation , single phase naturally oil cooled indoor type & designed for input variation between 340 V to 480 V with Output voltage stabilizer at 415 V with accuracy of +/- 1% and capacity of 200 KVA as specified and directed BI01010001010000000000000515BI0100001119 1 Each Job
9 6.01 1. High Voltage Cut off 2. Low Voltage Cut off 3. Time delay of 3 sec. for Cut off. 4. Single Phase Prevention and cut off 5. Phase Reversal Protection and cut off 6. Surge & Spike Protection/Surge Arrester/RF Suppressor 7. Frequency cut off protection 8. Neutral failure protection 9. Earth neutral voltage cut off protection 10. Electronic over& under voltage trip with time delay for input & output \n 11. Electronic overload protection and short circuit protection and the manual bypass is built in \n12. Fully Automatic / Manual Provision of stabilizer bypass mode switch Manual / Auto Reset with time delay and Programmable 13. Response Time : Less than 10mili second BI01010001010000000000000515BI0100001120
10 7 Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of 150Sqmm sizes BI01010001010000000000000515BI0100001121 50 RM
11 8 Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.\n BI01010001010000000000000515BI0100001122 630 Cum
12 9 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed. BI01010001010000000000000515BI0100001123 360 Cum
13 10 Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. BI01010001010000000000000515BI0100001124 270 Cum
14 11 M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.\nNote :- Thickness of sand cushion after punning down shall be measured for payment. BI01010001010000000000000515BI0100001125 190 Cum
15 12 M&L brick protection with common burnt brick sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed by Engr-in-charge. BI01010001010000000000000515BI0100001126 40 1000Nos
16 13 S&F in repairs Weather proof outdoor / indoor panel box 750x750x300 mm, 3 mm thick CRCA sheet and aluminium bus bar 200 amps capacity for 3 phase and neutral 100 amps and along with all suitable internal Copper wiring from bus bar to meter and meter to 2 pole MCB and transparent glass to see the reading of 4 meters complete all as specified and directed. BI01010001010000000000000515BI0100001127 20 Each Job
17 14 Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes BI01010001010000000000000515BI0100001128
18 14.01 240 Sqmm 3.5 core. BI01010001010000000000000515BI0100001129 250 RM
19 14.02 150 Sqmm 3.5 core. BI01010001010000000000000515BI0100001130 250 RM
20 14.03 95 Sqmm 3.5 core. BI01010001010000000000000515BI0100001131 300 RM
21 14.04 35 Sqmm 3.5 core. BI01010001010000000000000515BI0100001132 2250 RM
22 15 M&L for PCC 1:3:6 type C1 using 20mm graded aggregate set in cement mortar 1:4 as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.\n BI01010001010000000000000515BI0100001133 2.5 Cum
23 16 M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed. BI01010001010000000000000515BI0100001134 1 Cum
24 17 M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed BI01010001010000000000000515BI0100001135 400 RM
25 18 Supply & lay Galvanised Iron tubing 40mm bore, light grade in protection of cable at road crossing/hard standing as per site requirement including taking down old unserviceable pipes complete all as specified and directed. BI01010001010000000000000515BI0100001136 350 RM
26 19 All as per item No 18 above but GI tubing 50 mm bore.\n BI01010001010000000000000515BI0100001137 50 RM
27 20 Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 400 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-\n (a)MCCB 4 pole adjustable, 200 Amp, 415 Volts 25KA - 01 No\n(b)MCCB 4 pole adjustable, 100 Amp, 415 Volts 16KA - 05 Nos(Including 1 No spare) \n(c) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)\n(d)Digital Voltmeter, Ammeter three phase class\n(e) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end terminaion lugs. \n BI01010001010000000000000515BI0100001138 2 Each
28 21 Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 600 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-\n(a)MCCB 4 pole adjustable, 400 Amp, 415 Volts 36KA - 01 No\n(b)MCCB 4 pole adjustable, 315 Amp, 415 Volts 36KA- 01 No \n(c)MCCB 4 pole adjustable, 100 Amp, 415 Volts 16KA- - 05 Nos (Including 1 No spares)\n(d) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)\n(e)Digital Voltmeter, Ammeter three phase class\n(f) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end terminaion lugs. BI01010001010000000000000515BI0100001139 1 Each
29 22 Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 400 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-\n(a)MCCB 4 pole adjustable, 315 Amp, 415 Volts 36KA - 01 No\n (b)MCCB 4 pole adjustable, 100 Amp, 415 Volts 16KA- - 07 Nos (Including 1 No spare) \n(c) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)\n(d)Digital Voltmeter, Ammeter three phase class\n(e) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end terminaion lugs. BI01010001010000000000000515BI0100001140 1 Each
30 23 Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 500 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-\n(a)MCCB 4 pole adjustable, 315 Amp, 415 Volts 36KA - 01 No\n(b)MCCB 4 pole adjustable, 200 Amp, 415 Volts 25KA- - 01 No\n(c)MCCB 4 pole adjustable, 100 Amp, 415 Volts 16KA- 05 Nos (Including 1 No spare) \n(d) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)\n(e)Digital Voltmeter, Ammeter three phase class\n(f) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end terminaion lugs. BI01010001010000000000000515BI0100001141 1 Each
31 24 S&F in repairs Weather proof outdoor bus bar chamber made out of 3mm thick MS sheet comprising 4 Nos aluminium strips each of 300Amps, 60cm long duly insulated mounted on insulators including 200 Amps MCCB with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers, cable glands at entry and outlet points and excavation, earth work, returning filling in and removal of surplus soils including taking out old unserviceable bus bar chamber complete all as specified and directed. BI01010001010000000000000515BI0100001142 1 Each Job
32 25 M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. \nNote :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate. BI01010001010000000000000515BI0100001143 5 Each Job