}

Appointment Of Implementation Agency For Implementation Of Adms In Varanasi City Of Puvvnl Discom Appointment Of Implementation Agency For Implementation OfAdms In Varanasi City Of Puvvnl Discom, Varanasi-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Appointment Of Implementation Agency For Implementation Of Adms In Varanasi City Of Puvvnl Discom Appointment Of Implementation Agency For Implementation OfAdms In Varanasi City Of Puvvnl Discom. Submission Date for this Tender is 03-11-2020. Consultancy Service Tenders in Varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24861048
Corrigendum : Appointment Of Implementation Agency For Implementation Of Adms In Varanasi City Of Puvvnl Discom Appointment Of Implementation Agency For Implementation OfAdms In Varanasi City Of Puvvnl Discom
Open Tender
Indian
Uttar Pradesh
Varanasi
03-11-2020

Tender Details

Appointment Of Implementation Agency For Implementation Of Adms In Varanasi City Of Puvvnl Discom Appointment Of Implementation Agency For Implementation Of Adms In Varanasi City Of Puvvnl Discom

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Aug-2020 Corrigendum Against GCC of PuVVNL Other 04-09-2020
2 23-Sep-2020 Tender Opening Date Extended11 Date 07-10-2020
3 08-Oct-2020 Tender Opening Date Extended12 Date 03-11-2020

Key Value

Document Fees
INR 29500 /-
EMD
INR 7000000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Appointment of Implementation Agency for Implementation of ADMS in Varanasi City of PuVVNL Discom
Sl. No. Item Description Item Code / Make Quantity Units
1 1 ADMS Field Equipment
2 1.1 Substation Modernization
3 1.2 Replacement of 11 KV old VCB or Motorisation and upgradation of old VCB item1 20 Set
4 1.3 Grid Sub Station
5 1.4 24VDC operated RTU with 80 DIs, 20 DOs, 16 AI I/Os in Panel item3 11 Set
6 1.5 CMR item4 550 Nos.
7 1.6 Interposing Relays item5 220 Nos.
8 1.7 MFT item6 110 Nos.
9 1.8 Earthing improvement ( electrical+electronic ) item7 11 Set
10 1.9 12 Port Switch compliant to 61850 item8 11 Set
11 2 Router Cum Firewall item9 11 Set
12 2.1 LDMS PC with Software item10 11 Set
13 2.2 UPS 1KVA with 1 hr Backup item11 11 Set
14 2.3 USB Based B/W Laserjet A4 size Printer item12 11 Nos.
15 2.4 Smart IIOT Based Condition Monitoring of Substation Transformer ( R,Y,B, N Lug temp, Oil Level & Temp) with controller on Modbus and integration with SS RTU item13 40 Set
16 2.5 Mandatory spare of RTU
17 2.6 DI Module item15 3 Nos.
18 2.7 DO Module item16 3 Nos.
19 2.8 CPU item17 3 Nos.
20 2.9 Power supply item18 3 Nos.
21 3 MFT item19 10 Nos.
22 3.1 CMR item20 20 Nos.
23 3.2 Interposing Relays item21 15 Nos.
24 3.3 24VDC DCPS for RTU with 4 hrs Backup(Wherever Require) item22 4 Set
25 3.4 Sub total (Substation Modernization)
26 3.5 Field Automation Part
27 3.6 Auto reclosure 11 KV/Sectionlizer 11 KV item25 60 Set
28 3.7 11KV RMU
29 3.8 3 WAY RMU with 3VMFT item27 260 Set
30 3.9 4 WAY RMU with 4 MFT item28 10 Set
31 4 XLPE Cable (400 Sqmm Almunium) item29 14000 Meters
32 4.1 Jointing Kit item30 1920 Set
33 4.2 FPI item31 160 Set
34 4.3 FRTU( including modem) at Field Devices with 10 DIs and 5 DOs item32 330 Set
35 4.4 48VDC DCPS for FRTU with 4 hrs Backup item33 330 Set
36 4.5 Sub total (Field Automation Part)
37 4.6 Communication Charges for 5 years
38 4.7 Network Connectivity Charges(1 Mbps) for MPLS of 11 SS to Both CC for 5years\n item36 5 Peryear
39 4.8 GPRS Charges for 330 FRTU for 5 years item37 5 Peryear
40 4.9 Sub total (Communication)
41 5 IT Hardware & Software
42 5.1 Hardware( Main Redundant and Backup Non Redundant)
43 5.2 SCADA/DMS server item41 3 Nos.
44 5.3 OMS server item42 3 Nos.
45 5.4 FEP server with interface switches item43 3 Nos.
46 5.5 Web server item44 3 Nos.
47 5.6 ISR/Historian server item45 3 Nos.
48 5.7 Development & Testing( One at Each CC) item46 2 Nos.
49 5.8 Developmental console with one TFT( One at Each CC) item47 2 Nos.
50 5.9 NMS & Image Backup server item48 3 No.
51 6 UA and Patch Management item49 3 Nos.
52 6.1 ICCP Server item50 3 Nos.
53 6.2 Firewall with Network IPS/UTM External item51 3 Nos.
54 6.3 Firewall(Internal) item52 3 Nos.
55 6.4 Router for CFE side( Redundant in Main and single at Backup) item53 3 Nos.
56 6.5 Router for Externalworld item54 2 Nos.
57 6.6 GPS & time display system item55 2 Nos.
58 6.7 Laser based Video Projection system with 2X3 Module configuration with each module at least 70" diagonal at Main CC only item56 1 Nos.
59 6.8 40kVA Redundant UPS & Single Batteries bank for 60 minutes backup with ACDB for Main control centre item57 1 Nos.
60 6.9 30kVA Redundant UPS & Single Batteries bank for 60 minutes backup with ACDB for Backup control centre item58 1 Nos.
61 7 Storage , Backup Devices
62 7.1 External RAID Mass storage device( 30TB) item60 2 Nos.
63 7.2 HIS Storage( 20TB) item61 2 Nos.
64 7.3 Switches
65 7.4 Layer III switch (SCADA/DMS LAN)-48 ports item63 2 Nos.
66 7.5 Layer III switch (External system LAN )-24ports item64 2 Nos.
67 7.6 Workstation Printer
68 7.7 Workstation Console with dual TFTs monitors item66 5 Nos.
69 7.8 Workstation Console with single TFT monitor item67 1 Nos.
70 7.9 MFT Color laser Jet A3 size Printer at Main only item68 1 Nos.
71 8 A4 Colour laserjet Printer ( Main and Backup) item69 2 Nos.
72 8.1 Weather Station Sensor
73 8.2 Weather transducer - wind speed item71 1 Set
74 8.3 Weather transducer - rainfall item72 1 Set
75 8.4 Weather transducer - Humidity item73 1 Set
76 8.5 Weather transducer -Temperature item74 1 Set
77 8.6 Weather transducer -Wind Direction item75 1 Set
78 8.7 RTU Test Kit
79 8.8 RTU Database Configuration & Maintenance Software tool item77 2 No.
80 8.9 Master Station cum RTU Simulator & Protocol analyser software tool item78 2 No.
81 9 Laptop PC for above software tools along with interfacing hardware including Hub item79 2 No.
82 9.1 FRTU Test Kit
83 9.2 FRTU Database Configuration & Maintenance Software tool item81 1 No.
84 9.3 Master Station cum FRTU Simulator & Protocol analyser software tool item82 1 No.
85 9.4 Laptop PC for above software tools along with interfacing hardware including Hub item83 1 No.
86 9.5 GPRS Gateway at CC
87 9.6 M2M Gateway for GPRS item85 2 No.
88 9.7 Sub Total (Hardware)
89 9.8 Software
90 9.9 SCADA software( License , Erection Charges) item88 1 Nos.
91 10 Historian Software ( License , Erection Charges) item89 1 Nos.
92 10.1 DMS software ( License , Erection Charges) item90 1 Nos.
93 10.2 OMS software ( License , Erection Charges) item91 1 Nos.
94 10.3 UA and PM software ( License , Erection Charges) item92 1 Nos.
95 10.4 Developmental software ( License , Erection Charges) item93 1 Nos.
96 10.5 ICCP software ( License , Erection Charges) item94 1 Nos.
97 10.6 Network Management & Image backup Software ( License , Erection Charges) item95 1 Nos.
98 10.7 WEB /Network security software ( License , Erection Charges) item96 1 Nos.
99 10.8 GIS Software Update /Customisation for DMS item97 1 Lot
100 10.9 GIS Adaptor/Engine for importing data from GIS item98 1 Nos.
101 11 Sub total (Software)
102 11.1 Sub Total (IT Hardware and Software )
103 11.2 Civil works
104 11.3 All civil & architectural works Internal & external electrifications Special electronic earthing for server system Precision air conditioning & ventilation Fire fighting system & access control system required for any office,Furniture , Lift , Two floors Main CC as per Technical Specs item102 2200 SQM
105 11.4 All civil & architectural works Internal & external electrifications Special electronic earthing for server system Precision air conditioning & ventilation Fire fighting system & access control system required for any office,Furniture , Lift , Two floors Backup CC as per Technical Specs item103 2200 SQM
106 11.5 ADMS Services
107 11.6 Door to door survey of consumers associated with all 11 substations of scope, indentifying the gap and required changes in the consumer indexing and its mapping with pole/DT and update the same in Existing Unified GIS Solution of Utility. Integration of ADMS with GIS for OMS upto Consumer. item105 1 Lot
108 11.7 Annual Maintenance Contract for 5 years after one year warranty item106 5 Per year
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail