Steel Industrials Kerala Limited has published Supply And Installation Of 150W Led Street Light From Town Bank Auditorium To Town Hall In Thalassery Municipality Supply And Installation Of 150W Led Street Light From Town Bank Auditorium To Town Hall In Thalassery Municipality. Submission Date for this Tender is 22-07-2020. Street Lighting Tenders in Thalassery municipality Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 17-Jul-2020 | Date extension corrigendum | Date | 20-07-2020 |
2 | 21-Jul-2020 | Date Extension | Date | 22-07-2020 |
Name of Work: SUPPLY AND INSTALLATION OF 20 NO.S OF 150W LED STREET LIGHT AT THALASSERY MUNICIPALITY Location :Town Bank Auditorium to Town Hall in Thalassery municipality | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply , conveyance, erection testing and commissioning of Octagonal pole Height 8mtr Top dia 70mm Bottom dia 155mm having sheet thickness 3mm base plate 250 x 250 x 16 mm with 4x24 mm Dia 750mm foundation bolts and with Single arm bracket 1.5 mtr long The Octagonal pole shall be hot dip galvanised in single section with Bakelite sheet with one 6A SP MCB and 16 sq mm stud type connector including Reiforced Cement concrete foundation of size not less than 500x500x2000mm etc. complete | BI01010001010000000000000515BI0100001113 | 20 | Nos |
2 | 2 | Supply, conveyance, installation, testing and commissioning of RoHS compliant 150w LED Street light fitting having light output of not less than 14000 lumen at 5700K (CRI 70) with IP 66 protection with all accessories with power factor >0.95 at full load, internal surge protection up to 5 KV AND EXTERNAL SURGE OF 10KV, and Aluminium pressure die-cast Powder coated housing . The entire light fitting should have a warranty of mimium 3 years. (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | BI01010001010000000000000515BI0100001114 | 20 | Nos |
3 | 3 | Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required. | BI01010001010000000000000515BI0100001115 | ||
4 | 3.01 | 32 mm dia medium gauge | BI01010001010000000000000515BI0100001116 | 10 | m |
5 | 4 | Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required | BI01010001010000000000000515BI0100001117 | ||
6 | 4.01 | 40 A four pole mini break isolator | BI01010001010000000000000515BI0100001118 | 1 | Nos |
7 | 4.02 | 40 A, 4 pole,30 mA RCCB | BI01010001010000000000000515BI0100001119 | 1 | Nos |
8 | 4.03 | 6 A to 25 A, 10 kA, TP MCB (C curve) | BI01010001010000000000000515BI0100001120 | 1 | Nos |
9 | 5 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. | BI01010001010000000000000515BI0100001121 | ||
10 | 5.01 | 3 core 2.5 sqmm | BI01010001010000000000000515BI0100001122 | 200 | m |
11 | 5.02 | 4 core 16sq mm | BI01010001010000000000000515BI0100001123 | 24 | m |
12 | 5.03 | 4 core 25 sq mm | BI01010001010000000000000515BI0100001124 | 440 | m |
13 | 6 | Supplying siemens / tropodur type nickel plated Double compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required. | BI01010001010000000000000515BI0100001125 | ||
14 | 6.01 | 16 sqmm | BI01010001010000000000000515BI0100001126 | 4 | Nos |
15 | 6.02 | 25 sq mm | BI01010001010000000000000515BI0100001127 | 60 | Nos |
16 | 7 | Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. | BI01010001010000000000000515BI0100001128 | ||
17 | 7.01 | 4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip | BI01010001010000000000000515BI0100001129 | 4 | Nos |
18 | 7.02 | 25 sq - 95sq mm with 20 mm wide x 1.20 mm thick clip | BI01010001010000000000000515BI0100001130 | 60 | Nos |
19 | 8 | Supply of superior quality aluminium reducer (banana) cable socket and making core termination of cables of the following sizes including crimping etc. as required. | BI01010001010000000000000515BI0100001131 | ||
20 | 8.01 | 16 sq mm | BI01010001010000000000000515BI0100001132 | 16 | Nos |
21 | 8.02 | 25 sq mm | BI01010001010000000000000515BI0100001133 | 240 | Nos |
22 | 9 | Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ordinary soil 0.75m below ground level | BI01010001010000000000000515BI0100001134 | ||
23 | 9.01 | 40 / 32 mm or nearest size | BI01010001010000000000000515BI0100001135 | 450 | m |
24 | 10 | Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil) | BI01010001010000000000000515BI0100001136 | 4 | Nos |
25 | 11 | Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strip sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. | BI01010001010000000000000515BI0100001137 | 10 | m |
26 | 12 | Supply and providing test joint for the earthing system using 2 x 25 x 3 mm GI strip sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. | BI01010001010000000000000515BI0100001138 | 1 | Met |
27 | 13 | Supply and laying strips of the following sizes along with wiring/ cables and giving connection as required. | BI01010001010000000000000515BI0100001139 | ||
28 | 13.01 | 25 x 3 mm GI strip | BI01010001010000000000000515BI0100001140 | 10 | m |
29 | 14 | Supply and drawing bare earthing conductors of No 10 mm GI conductor sizes along with wiring/ cables and giving connection as required. | BI01010001010000000000000515BI0100001141 | 450 | m |
30 | 15 | Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required | BI01010001010000000000000515BI0100001142 | ||
31 | 15.01 | 25 x 3mm brass bolt & nut | BI01010001010000000000000515BI0100001143 | 32 | Nos |
32 | 15.02 | 25 x 6 mm brass bolt & nut | BI01010001010000000000000515BI0100001144 | 32 | Nos |
33 | 16 | Supply and installation of sintex Box for 3 phase meter | BI01010001010000000000000515BI0100001145 | 1 | Nos |
34 | 17 | Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable trays made out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required. | BI01010001010000000000000515BI0100001146 | 30 | Kg |
35 | 18 | Supply and providing the following components in place as required. | BI01010001010000000000000515BI0100001147 | ||
36 | 18.01 | Single dial timer Unit | BI01010001010000000000000515BI0100001148 | 1 | Nos |
37 | 18.02 | 3 pole 40 A contactor with AC Coil | BI01010001010000000000000515BI0100001149 | 1 | Nos |
38 | 19 | Supply and fixing the following accessories in the existing meter board and giving connections etc. | BI01010001010000000000000515BI0100001150 | ||
39 | 19.01 | 32 A fuse holder for BS type blade fuses. | BI01010001010000000000000515BI0100001151 | 3 | Nos |
40 | 19.02 | 20-32 A, bolted offset tag type fuse link of size A1 | BI01010001010000000000000515BI0100001152 | 3 | Nos |
41 | 19.03 | 32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base. | BI01010001010000000000000515BI0100001153 | 1 | Nos |
42 | 20 | SITC of Name Board by using granite stone 60x45 CM | BI01010001010000000000000515BI0100001154 | 1 | Nos |
43 | 21 | KSEB charges for availing 3 Phase Connection as per actual Cash reciept | BI01010001010000000000000515BI0100001155 | 1 | Nos |