Fire Alarm System At Rajkiya Ashram Paddhati Vidyalaya ( 480 Seated ) Dormitory Block At Dunara , Distt . Jhansi, Jhansi-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Fire Alarm System At Rajkiya Ashram Paddhati Vidyalaya ( 480 Seated ) Dormitory Block At Dunara , Distt . Jhansi. Submission Date for this Tender is 15-07-2020. Fire Alarm Systems Tenders in Jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24814752
Fire Alarm System At Rajkiya Ashram Paddhati Vidyalaya ( 480 Seated ) Dormitory Block At Dunara , Distt . Jhansi
Open Tender
Indian
Uttar Pradesh
Jhansi
15-07-2020

Tender Details

Fire Alarm System At Rajkiya Ashram Paddhati Vidyalaya ( 480 Seated ) Dormitory Block At Dunara , Distt . Jhansi

Key Value

Document Fees
INR 7080 /-
EMD
INR 81000.0 /-
Tender Value
INR 40.33 Lakhs /-

BOQ Items

Name of Work: Fire Fighting system of Rajkiya Ashram Paddhati Vidyalaya (480 Seated) at Dunara Distt. Jhansi
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supplying Installation testing & Commissioning UL listed Intelligent Addressable 2 loops fire alarm control panel is able to connect minimum 200 addressable points (Detector and devices ) per loop in any combination with full load, fully touch screen LED display, 96 Zonal LEDs on board, capacity to have upto 250 logic zones, 4 NAC circuits, 3 programmable relays, dedicated Alarm relay, Integral short circuit, Event history of 9,999 logs, capacity to communicate loop mount repeater panels, optional NAC power supply units that are loop mountable and 100% supervised from main panel, battery back-up of 24 hours at standby & 30 min in alarming condition, on board printer facility.Make :- Eaton / Heinrich (U.K.) / Potter (U.S.) (Main Building) BI01010001010000000000000515BI0100001113 1 Set
2 2 Supplying Installation testing & Commissioning UL listed Intelligent Addressable 1 loop fire alarm control panel is able to connect minimum 200 addressable points (Detector and devices ) per loop in any combination with full load, fully touch screen LED display, 96 Zonal LEDs on board, capacity to have upto 250 logic zones, 4 NAC circuits, 3 programmable relays, dedicated Alarm relay, Integral short circuit, Event history of 9,999 logs, capacity to communicate loop mount repeater panels, optional NAC power supply units that are loop mountable and 100% supervised from main panel, battery back-up of 24 hours at standby & 30 min in alarming condition, on board printer facility.Make :- Eaton / Heinrich (U.K.) / Potter (U.S.) (Dining hall) BI01010001010000000000000515BI0100001114 1 Set
3 3 Supplying Installation testing & Commissioning UL listed Intelligent Addressable 4 loop fire alarm control panel is able to connect minimum 200 addressable points (Detector and devices ) per loop in any combination with full load, fully touch screen LED display, 96 Zonal LEDs on board, capacity to have upto 250 logic zones, 4 NAC circuits, 3 programmable relays, dedicated Alarm relay, Integral short circuit, Event history of 9,999 logs, capacity to communicate loop mount repeater panels, optional NAC power supply units that are loop mountable and 100% supervised from main panel, battery back-up of 24 hours at standby & 30 min in alarming condition, on board printer facility.\nMake :- Eaton / Heinrich (U.K.) / Potter (U.S.) (Dormitory Block) BI01010001010000000000000515BI0100001115 1 Set
4 4 Supplying Installation testing & Commissioning of Addressable 2 wire optical smoke detector with built-in short circuit isolator, 100% soft addressing, single LED that covers 360Deg lightpipe technology, Drift compensation, Removable detector chamber, with operating temperature of 32ºF to 100ºF, Analogue level monitored on panel, Alarm current of 5mA (max), Standby current 220 µA (average), option to connect remote indicator. The detector shall be with inbuilt isolator. Make : Eaton / Heinrich (U.K.) / Potter (U.S.)(Main Building+Dining hall+Dormitory block) BI01010001010000000000000515BI0100001116 328 Nos.
5 5 Supplying Installation testing & Commissioning of Remote red LED alarm indicator on single gauge stainless steel plate of same make as fire alarm panel. Make :- Eaton / Heinrich (U.K.) / Potter (U.S.)(Main Building+Dining hall+Dormitory block) BI01010001010000000000000515BI0100001117 71 Nos.
6 6 Supplying Installation testing & Commissioning of Intelligent Addressable 2 wire Single Action Pull Station with built in short circuit isolator, 100% soft addressed from panel,Wall mounting, resettable key option, Corrosion resistant gold plated SPST contacts, option of Single action or Dual action, optional Whether proof back box. Make :- Eaton / Heinrich (U.K.) / Potter (U.S.) (Main Building+Dining hall+Dormitory block) BI01010001010000000000000515BI0100001118 20 Nos.
7 7 Supplying Installation testing & Commissioning of Intelligent Addressable Hooter cum strobe.Unit as per specifications and customization of intensity selection as 15, 30 ,75 or 110 cd of strobe unit is possible by panel.Sounder sum strobe will be driven by supervised 24 V DC input and will give 80 db output at 3 m strobe unite will be synchronized 1 Hz strobe flash rate for better evacuation in complete facility.Make :- Eaton / Heinrich (U.K.) / Potter (U.S.) (Main Building+Dining hall+Dormitory block) BI01010001010000000000000515BI0100001119 20 Nos.
8 8 Supplying Installation testing & Commissioning Intelligent Addressable 2 Wire Control module, 100% soft addressed, with built in short circuit isolator. Usage like shutting down AHU’s, and magnetic fire door holders, Elevator recall, fire damper, pressurization fan, speakers, strobes etc.Make :- Eaton / Heinrich (U.K.) / Potter (U.S.) (Main Building+Dining hall+Dormitory block) BI01010001010000000000000515BI0100001120 6 Nos.
9 9 Supplying Laying testing & Commissioning of FRLS 2 core x 1.5 sq.mm single standard copper conductor , PVX insulated armored cable.Make: Finolex/KEI/Bonton (Main Building+Dining hall+Dormitory block) BI01010001010000000000000515BI0100001121 2810 Mtr.
10 10 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS :15683) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. Make :- Rcube Fire Protection Services Pvt. Ltd. /R.K.Engineers Services. CE Certified, ISO 13485 : 2016 & OHSAS 18001 : 2007 Approved. (Main Building+Dining hall+Dormitory block) BI01010001010000000000000515BI0100001122 18 Nos.
11 11 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. Make :- Rcube Fire Protection Services Pvt. Ltd. /R.K.Engineers Services. CE Certified, ISO 13485 : 2016 & OHSAS 18001 : 2007 (Main Building+Dining hall+Dormitory block) BI01010001010000000000000515BI0100001123 26 Nos.
12 12 Fire man axe. Make :- Rcube Fire Protection Services Pvt. Ltd. /R.K.Engineers Services.CE Certified ISO 13485 : 2016 & OHSAS 18001 : 2007 Approved. (Dormitory block) BI01010001010000000000000515BI0100001124 6 Nos.
13 13 Supplying Installation testing & Commissioning of Intelligent Addressable type heat Detector along with base as per specification rate of rise temperature range is at 8.3 dgree c/ 11.1 dgree c per min and fixed temperature sensing is independent of rate of rise sensing to operate at 57.2 dgree c /68 dgree c support digital communication and magnetically operated functional test. The detector shall be with inbuilt isolator.Make :- Eaton / Heinrich (U.K.) / Potter (U.S.) Imported (Dining hall) BI01010001010000000000000515BI0100001125 3 Nos.
14 14 GST as per Applicable BI01010001010000000000000515BI0100001126